Metal Analysis by Flame and Plasma Atomic Spectroscopy Flame A. Atomization 1. Types of Atomization Processes a.) Nebulizers b. Electrothermal atomization.

Slides:



Advertisements
Similar presentations
Atomic Absorption.
Advertisements

Optical Atomic Spectroscopy
Lecture 6 ATOMIC SPECTROSCOPY
Atomic Absorption & Emission Spectroscopy
1.1 Atomic Absorption Spectrometry (AAS) determination of elements not compounds needs radiation source high temperature for atomization Atomization a.
Elemental Analysis - Atomic Spectroscopy
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chapter 8 & 9 Atomic Absorption Spectroscopy
427 PHC. Direct-Current Plasma  A direct-current plasma (DCP) is created by an electrical discharge between two electrodes. A plasma support gas is necessary,
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Chapter 10 ATOMIC EMISSION SPECTROMETRY
1 A TOMIC SPECTROMETRIC METHODS PART 9. 2 Interferences : Four classes of interferences: 1-Spectral interferences 2-Chemical interferences 3- Refractory.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Atomic Absorption Spectroscopy (AAS) The Visible Spectra.
Molecular Fluorescence Spectroscopy
Emission Spectroscopy Based upon Plasma, Arc, and Spark Atomization Arc Arc Higher Temperature Higher Temperature Lower interelement interference Lower.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Chapter 14 Applications of Ultraviolet-Visible Molecular Absorption Spectrometry.
announcements and reminders
Lecture 2 M.Sc.. AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO.
Atomic spectra are a result of energy level diagrams - quantum theory.
Atomic Absorption Spectroscopy (AAS)
OPTICAL ATOMIC SPECTROMETRY Chap 8 Three major types Optical spectrometry Optical spectrometry Mass spectrometry Mass spectrometry (X-ray spectrometry)
Instrumental Chemistry
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY Chap 9 Source Modulation Interferences in Atomic Absorption Interferences in Atomic Absorption Spectral.
Atomic Absorption Spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Biochemical instrumental analysis-2
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Atomic Absorption Spectroscopy
Atomic Absorption Spectrophotometer
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
to Optical Atomic Spectroscopy
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Chapter 9 Atomic Absorption and Atomic Fluorescence Spectrometry
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
What is Atomic Spectroscopy? – Sec Atomic Absorption Spectroscopy (AAS) versus Atomic Emission Spectroscopy (AES)
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Atomic Spectroscopy Flame emission spectroscopy (FES)
1 Chapter 8 Atomic Absorption Spectroscopy ( AAS ) Yang Yi College of Science, BUCT.
Chapter 28 Atomic Spectroscopy.
By Maryum Atique M.Phill chemistry University of Agriculture.
Chem. 133 – 4/4 Lecture.
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Emission Spectrometry
Flame Photometer.
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
Elemental composition
Atomic Absorption Spectroscopy
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Inductively Coupled Plasma
Presentation transcript:

Metal Analysis by Flame and Plasma Atomic Spectroscopy Flame A. Atomization 1. Types of Atomization Processes a.) Nebulizers b. Electrothermal atomization 2. Line Width 3. Effect of Temperature B. Interferences C. Sample Preparation Plasma Emission Spectroscopy

Continuous Atomizers Used in AA and DCP (direct current plasma)

Discrete Atomizers Sample is atomized all at once, allowing for better detection limits

Line Width Which is wider, atoms or molecules spectra? Factors contributing to line width: 1.) Uncertainty Principle Lifetimes of excited states are only a finite amount of time. There are uncertainties in transition time. Called natural line width. Overall A

Doppler Broadening Detector longer  shorter

Pressure Broadening Arises from collisions between analyte and other atoms or ions in heated media, result in small changes in g.s. energy and hence a spread in wavelength In high pressure Hg and Xe lamps pressure broadening is so extensive that continuous radiation is produced.

Temperature Extremely important to have it consistent in order to get consistent amount of atomization

Spray Solution of Analyte Solid/ gas aerosol Gaseous molecules Atoms Atomic ions Excited molecules Excited atoms Excited ions Nebulization Desolvation Volatilization Dissociation Ionization h molecular h atomic

Why does a reproducible temperature matter so much? 1.Temperature effects population size of ground and excited states 2.10K change in temperature for Na results in a 4% change in excited state population 3.Emission spectroscopy more sensitive to small temperature changes in flame than are absorption and fluorescence because they are based on excited state populations

Flames and Atomization Flame temperature and position are critical for achieving reproducible atomization 1 o combustion region: Not at thermal equilibrium, blue due to C2CH, & other radicals, not used for analytical spectroscopy Outer zone: Atoms from inner core are converted to stable molecular oxides, cooler Interconal region: Pretty narrow in stoichiometric flames, rich in free atoms, widely used for analytical spectroscopy

Gases used Common FuelsCommon oxidants Natural gasAir H2H2 O2O2 AcetyleneNitrous Oxide

Why is the burner the shape that it is? Sensitivity of metal with burner height varies by metal, see transparency

Electrothermal atomizers a.k.a. graphite furnaces Sample is introduced into graphite tube, solvent evaporated, & then heated rapidly to K w/high current Sample residence time up to 1 second Detection limit – g/Sample

Disadvantages of Graphite Furnaces 5-10% precision vs. 1% for flame or plasma Slow/sample Linear range <2 orders of magnitude

Interferences Spectral Interferences: Arises when absorption or emission of other species in solution lies very close to the same wavelength 1. Can result from combustion products of flame fuel or oxidant 2. Molecular oxides from sample itself

Ways to correct for matrix interferences 1.Two line correction method: Pick line very close to analyte spectral line but that analyte does not absorb at, subtract 2 lines 2.Background correction: Subtract continuous source (such as D2) from sample 3.Zeeman correction: Magnetic field applied produces plane polarized light, light goes through polarizer only when sample is introduced

Chemical Interferences Result from chemical processes occurring during atomization that alter the absorption characteristics of the analyte: Easier to correct for then spectral interferences!

1. Anion Interference Most common: Anions will react w/analyte to produce a species of low volatility ex. PO43- or SO42-. This will significantly reduce Ca (or other metal’s) absorption by making Ca3(PO4)2 and CaSO4 Cation interference also possible Can be minimized w/ releasing agents or protective agents which react preferentially with interfering species, for ex. Sr will react preferentially w/PO43- making it possible to determine Ca

Protective Agents Form stable but volatile complexes w/ analyte

2. Ions in Flames Can be minimized w/ ionization supressor which produces an excess of ions so L’Chatlier’s principle is employed M === M+ + e-

3. Formation of Stable Compounds Some analytes are atomized with difficulty, i.e. Hg or Pb For these you must use a hotter flame or a fuel rich flame Cool flame Hot flame

Sample Preparation for Metal Analysis Dissolved metals: What passes through a 0.45um membrane filter of an unacidified sample Suspended metals: What is retained on a 0.45um membrane filter of an unacidified sample Total metals: Sum of dissolved and suspended metals Acid extractable metals: [ ] of metals in solution after treatment of unfiltered sample with hot acid

Sample Handling for Metal Analysis 1.Filter immediately 2.Preserve with acid to pH = Can store up to 6 months 4.Containers: teflon > polypropylene > linear polyethylene > glass { Avoid glass for trace levels} Detergent wash, tap water rinse, soak in acid, rinse with metal free water Avoid paints, rubber, paper, and metal objects

Sample Extraction Sample is digested in concentrated HCl, HNO3, H2SO4, etc. by boiling to lowest volume before precipitation, cover w/ watch glass to avoid spattering Purpose of acid digestion is to oxidize the organic materials in sample and dissolve all the metals Continuous atomizers require samples to be in solution but discrete atomizers do not Organic solutions will affect outcome, increase sensitivity b/c less surface tension resulting in finer drop size