S8610U3009 Universal Electronic Ignition Modules Training Module (plus Universal Retrofit Kits Y8610U4001 and Y8610U6006)

Slides:



Advertisements
Similar presentations
Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Advertisements

VR8345 Universal Electronic Ignition Gas Valve Training Module
Isolation Verification Control Mining - Marine - Transit – Solutions LIVE Distributed By Locksafe Industrial Safety Equipment.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Enhanced Easy-Stop TM Trailer ABS Training. Enhanced Easy-Stop Trailer ABS System configurations to meet any air-braked trailer application 2S / 1M, 2S.
FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Condensate Trap Heater KGAHT0201KIT 2013 Fall Zone Meeting Gary Georgette/Jerry Shipman UTC Climate, Controls & Security Confidential and Proprietary Information.
Motorcycle product sheets
Heating Control Devices
R7284U1004 Universal Digital Electronic Oil Primary Training Module
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Futera III Wiring Diagram Presentation G.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
HVAC121 – Gas Heat Flame Rectification.
Furnace Troubleshooting
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
Gas Furnace Controls Part 4.
S8910U1000 Universal Electronic Ignition Modules Training Module
 Available with Inputs from 40 to 200 MBH and System Lengths of 10 to 80 Feet  All Units are Field Assembled and Utilize Sterling’s Integral Tube/Reflector.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Product Introduction.
ST9120U1003 Universal Electronic Fan Timer Training Module
S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module
Gas Furnace Controls Part 2.
Table of Contents Safety Circuits Induced Draft Motors Gas Valves
TR20 Series Wireless Training Slides New Product Introduction March 2009.
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
Variable Speed Indoor Blower Motor Robert Helt Technical Conference - Panama City Beach, Fl
Service/Review... Rule # 1: Use the KISS Principle!
Gas Furnace Planned Maintenance
Troubleshooting Electric Control Devices
7.4.1 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Operating Characteristics of Circuit Control Devices, Electromagnetic.
HYDRONIC HEATING AQUASTATS
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
Robertshaw Millivolt Troubleshooting Guide Gas Products
MICE Hydrogen Control System MICE Collaboration Meeting CM33 27 th July 2012 PJ Warburton – STFC Daresbury Lab.
BOILERS WATER HEATERS POOL HEATERS. RBI Futera III Modulation.
7.4.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Systematic Troubleshooting Techniques and Guidelines for Gas Operated.
CONTROL BOX RMG
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
RL BLU BUrners TRAining CEntre. RL BLU BUrners TRAining CEntre CONTROL BOX LOA B27 FEATURES: #Electrical protection IP 40 #Electrical.
Product Introduction January 2009
Student Handout Packet – Page A7
Simplicity Series The 1st Fuel-Convertible Concentric Vent
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
BUrners TRAining CEntre GAS BURNERS N 120, 200, 400 N 120, 200, 400 series.
Page A5 Schematic Analysis for Sequence of Operation (AUTOMATIC Spark Ignition System)
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
E3 HVACR Controls and Devices
Unit 7 Gas Heat: Natural and LP
Introducing the Bradford White ICON System™ and Accessory Packages
OBJECTIVES Explain the ABS diagnostic procedure and the brake warning lamp operation. Explain how to retrieve ABS diagnostic trouble codes. Explain how.
E3 HVACR Controls and Devices
Gas Furnace Controls Part 1.
Personal Protective Equipment
CONTROL BOX RMG
Flotection: Building Main Shutoff System
S8910U1000 Universal Electronic Ignition Modules Training Module
ST9120U1003 Universal Electronic Fan Timer Training Module
VR8345 Universal Electronic Ignition Gas Valve Training Module
Universal Interrupted Electronic Oil Primary R7184U Training Module
TR20 Series Wireless Training Slides
Presentation transcript:

S8610U3009 Universal Electronic Ignition Modules Training Module (plus Universal Retrofit Kits Y8610U4001 and Y8610U6006)

What you will learn Ignition Types S8610U3009 Features and Benefits Installation and Set Up Troubleshooting S8610U Advantage Y8610U Retrofit Ignition Kit Overview Product Cross Reference Information

Ignition Sources There are 3 different ways a burner can be ignited: 1) Standing Pilot Ignition 2) Intermittent Pilot Ignition Intermittent Pilot - S8610U 3) Direct Burner Ignition Hot Surface Ignition – S8910U Direct Spark Ignition – S87

S8610U3009

Universal Intermittent Pilot Module What is the S8610U3009? Provides electronic control of intermittent pilot ignition systems used on gas fired furnaces, boilers, and other heating appliances It’s the brain of the ignition system Receives call for heat signal from the thermostat Starts the spark ignition Opens the pilot valve Senses to see if the pilot is lit Opens the main burner Shuts things down at the end of the call for heat Monitors damper as opened or closed, if damper is attached One Part Number: S8610U3009

Normal Operation of an Intermittent Ignition Module Call for Heat On Off Valve On Pilot Lights Prove Pilot Burner Lights Valve On End Call for Heat Main Burner Pilot Ignition On a call for heat, both the Pilot valve and the Ignition come on together. Once the pilot is proved, the Ignition shuts off and the Main burner opens and remains open throughout the call for heat. When the call for heat ends, both the Main burner and Pilot shut off together.

S8610U Features Universal Compatibility Application Flexibility Replaces more than 400 Honeywell and competitive models Application Flexibility Works in single-rod and dual-rod applications Works with both natural and LP gas Quality Honeywell Control Provides electronic control for nearly any intermittent pilot ignition systems used on gas-fired furnaces, boilers and more Suitable for use with vent dampers Provides the ignition sequence, flame monitoring and 100% safety shutoff Enhanced Features Single LED indicates flame strength and gives diagnostic information Direct flame signal readout form the board Simplified error codes on label

The Benefits Benefit Feature Allows for more options in the field: 0 or 30 second prepurge and 15 or 90 second trial for ignition Assures selected sequence is retained permanently Green LED indicates status, error codes and pilot flame strength If senses use with a vent damper it locks the control, so damper must be used Provides 100% shutoff for both Natural and LP applications Feature Field selectable operating sequence can be customized Control locks to selected sequence on 20th “call for heat” LED communicates system status Integral damper connector Continuous retry ignition sequence

Additional benefits Feature Benefit Single-rod or dual-rod flame sensor Terminal-to-terminal wiring instructions Flame sense terminal 3/16” male QC (virtually all 2-rod systems sold have the sense terminal as 3/16” QC) Spark cable adapter 2.0 A main valve load rating Benefit Works in more applications Reduces wiring errors Prevents possible mis-wire of spark sense and potential for abnormal appliance light-off Includes adapter for rajah and nail type cable on existing systems; Simplified use Broader application; Fits more jobs

Ignition Sequences when a pilot fails to light Call for Heat Lockout Continuous Retry Non- Lockout Valve & Ignition On Valve & Ignition Off or... 5 Min Off 90 Sec Trial Trial Period Shuts off and does not retry Does not shut off, could be a safety issue S8610U - Continuous retry with 100% safety shutoff between trials

S8610U Control Layout SPARK MV TH-W (OPT.) REMOTE SENSE MV/PV 24V (OPT.) PV SENSE JUMPER WIRE 24 GND BRN/GND CUSTOMIZE OPERATING SEQUENCE P1 VENT DAMPER CONNECTOR FLAME CURRENT MEASUREMENT PORTS STATUS LED

Installation

Installation of the S8610U Mount new ignition module Wire the module Do not mount with terminals facing up protect the module from exposure to water, moisture, corrosive chemicals and excessive dust and grease. Wire the module Wire the module per the installation instructions Verify the thermostat anticipator setting

Wiring continued For systems with a vent damper connect the damper to P1 Once the vent damper connection is made, the control must be used with a vent damper.

Use With 1-Electrode Pilot S8610U CONTINUOUS RE-TRY 24V, 60 Hz; PV = 1A Max.; MV = 2A Max. ! WARNING MV MV/PV PV GND 24V TH-W If module has been used with vent damper, it will only work with damper connected. Honeywell STATUS S1 1 2 ON SPARK SENSE DAMPER 90 Sec. Trial for Ignition 0 Sec. Prepurge To wire this up, one wire runs from the Igniter to the module SPARK terminal. The black jumper connected to the SENSE terminal remains connected Jumper remains on SENSE

OR Use With 2-Electrode Pilot On a two rod application, there will be two wires running from the pilot to the module. The high voltage wire to SPARK and the flame sensor wire to SENSE MV MV/PV PV GND 24V TH-W ! WARNING Honeywell DAMPER S8610U CONTINUOUS RE-TRY 24V, 60 Hz; PV = 1A Max.; MV = 2A Max. If module has been used with vent damper, it will only work with damper connected. 90 Sec. Trial for Ignition 0 Sec. Prepurge STATUS Unplug jumper and cut off wire ON 1 2 S1 SPARK SENSE Spark Wire Sense Wire

Set Up

Set Up the S8610U Review the module installation and set up for use Visually inspect, safety check, and review operating sequence per installation instructions Customize the operating sequence based on the specifications of the originally installed control

Customize Operating Sequence Set the dip switches per the application. Prepurge Trials for Ignition Sw 1 Sw 2 None 90 Seconds OFF OFF 30 Seconds 90 Seconds ON OFF None 15 Seconds Off ON 30 Seconds 15 Seconds ON ON

Troubleshooting

Troubleshooting of the S8610U Flame signal is not getting back to the module This is a common problem Probable causes Bad wiring in the flame detection circuit Pilot not burning properly Flame sensor damaged/corroded Cracked/contaminated ceramic

LED status and flame strength Green LED status codes Indicates status, error codes and flame strength

Status LED Green Status LED Codes OFF No “call for heat” Flash fast Power up – internal check Heartbeat Normal startup – ignition started 2 5 min. retry delay 3 Recycle 4 Flame out of sequence 5 Damper error 6 Control internal error 7 Flame rod shorted to ground 8 Low voltage 4-second solid on followed by “x” 1-second flashes indicates flame current

Flame current measurement Pilot flame current can be measured using a standard micro-ammeter

Universal IP Retrofit Ignition System Kits Y8610U

Universal IP Retrofit Ignition System Kit What is the Y8610U? Complete kit converting conventional standing pilot systems to intermittent pilot systems. Use with 24 Vac gas-fired atmospheric furnaces, boilers and heating appliances Natural or LP gas (includes LP conversion kit) Reintroduced in 2007 to include the new S8610U3009

Y8610U6006 Features The Y8610U6006 (replaced Y8610U3003) Ignition System Kit includes: S8610U3009 Intermittent Pilot Ignition Module VR8304M3558 Gas Valve - ¾” x ¾” Harness Assembly, Ignition Cable Assembly, Mounting Kit, Ignitor, L.P. Conversion Kit, Pipe Bushing or Fitting and ¾” Straight Flange Y8610U6006 FEATURES : Continuous Retry Ignition Sequence LP or Natural Gas Valve Capacity – 270K BTUH ¾” to ½” Bushings LP Kit

Y8610U4001 Features Y8610U4001 (replaced Y8610F5003) includes: S8610U3009 Intermittent Pilot Gas Burner Control VR8204A2142 Gas Valve – ½” X ½” Harness Assembly, Ignition Cable Assembly, Mounting Kit, Igniter Kit, L.P. Conversion Kit, and ¾” Straight Flange Y8610U4001 FEATURES : Continuous Retry Ignition Sequence LP or Natural Gas Valve Capacity – 150K BTUH LP Kit

Product Cross Reference

Product Cross Reference Where do I find Honeywell electronic ignition cross reference and selection information? www.customer.honeywell.com Honeywell Application Selection and Cross Reference Guide – Form 63-9575 Honeywell Laminated Truck Visor – Form 63-9581G S8610U Technicians Quick Reference Guide – Form Honeywell Residential Technical Support: 1-800-468-1502 63-9581G 63-9575

Product Cross Reference Guide Forms 63-9575 and 63-9581G – information also found in product installation sheets.

www.customer.honeywell.com See Cross Reference Search box in right column.

The S8610U Advantage When promoting the S8610U keep these advantages in mind: The S8610U replaces over 400 Honeywell and competitor’s ignition modules, reducing inventory and callbacks. Easy Installation saves the contractor valuable time and resources. Field-selectable pre-purge and ignition timings make the S8610U a Universal replacement The S8610 is application flexible and can be used with single rod or dual rod systems, and natural or LP gas. The diagnostic LED and flame signal indicator make troubleshooting simple, solving the problem quickly and satisfying the customer.

S8610U Universal Electronic Ignition Knowledge Test

Universal Electronic Ignition Knowledge Test Now that you completed this training module, take the short quiz to test your knowledge.

Test The S8610U3009 is an intermittent pilot ignition module? T or F The S8610U is application flexible and work with single or dual rod systems? T or F On the S8610U once the controls senses a vent damper, the control can be used without a vent damper? T or F The operating sequence on the S8610U is customized by setting dip switches on the device? T or F A new feature on the S8610U includes a separate LED flame signal indicator? T or F

Test The S8610U has continuous retry and 100% safety shut off between cycles? T or F The S8610U works with only natural gas? T or F Flame strength readings can be taken directly from the board with a standard micro-ammeter? T or F The Y8610U kits convert applications from standing pilot to hot surface ignition? T or F The Honeywell S8610U replaces over four hundred Honeywell and competitive ignition modules? T or F

Answer Key T F