Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.

Slides:



Advertisements
Similar presentations
1.1 Atomic Absorption Spectrometry (AAS) determination of elements not compounds needs radiation source high temperature for atomization Atomization a.
Advertisements

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
1 A TOMIC SPECTROMETRIC METHODS PART 9. 2 Interferences : Four classes of interferences: 1-Spectral interferences 2-Chemical interferences 3- Refractory.
Metal Analysis by Flame and Plasma Atomic Spectroscopy Flame A. Atomization 1. Types of Atomization Processes a.) Nebulizers b. Electrothermal atomization.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
Analytical Chemistry –Atomic absorption Spectroscopy
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
announcements and reminders
Lecture 2 M.Sc.. AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO.
Atomic Absorption Spectroscopy (AAS)
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Atomic Absorption Spectroscopy (AAS)
Spectroscopy Chapter 7.
Fluorescence. Topics Definition Instrumentation Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-induced Fluorescence.
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
Atomic Absorption Spectroscopy
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Atomic Absorption Spectroscopy
Atomic Absorption Spectroscopy
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
Fluorometric determination of riboflavin
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Beers Law for a Single Component Sample I0I0 A = Absorbance = - log 10 I I / I 0 b = Optical path length c = Solution Concentration (M/L) ε = Molar Absorptivity.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
Chapter 9 Atomic Absorption and Atomic Fluorescence Spectrometry
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Elemental Analysis using Atomic Absorption and Emission Spectroscopy Bodhisatwa Das.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
QUANTITATIVE ANALYSIS Determining amount of ions present in samples.
Fluorometric determination of riboflavin
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
1 Chapter 8 Atomic Absorption Spectroscopy ( AAS ) Yang Yi College of Science, BUCT.
Chapter 28 Atomic Spectroscopy.
Chem. 133 – 4/4 Lecture.
Satish Pradhan Dnyanasadhana College Department Of Chemistry
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Emission Spectrometry
Flame Photometer.
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
Spectroscopy Chapter 7.
Introduction to Atomic Spectroscopy
Elemental composition
Atomic Absorption and Atomic Fluorescence Spectrometry
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Пламена Спектроскопија
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time.

Block Diagram h + M → M* Sample is vaporized/atomized by: Flame Electrothermal Vaporizer (ETV) h + M → M* Sample is vaporized/atomized by: Flame Electrothermal Vaporizer (ETV)

AA Sources- HCL

Flame AAS: sample introduction Sample is dissolved into solution (usually acidic). Sample is pulled through straw into nebulizer. Most of samples goes to waste. Nebulizer sends droplets/aerosol to flame to be de-solvated, resulting in gaseous molecules/atoms. Sample is dissolved into solution (usually acidic). Sample is pulled through straw into nebulizer. Most of samples goes to waste. Nebulizer sends droplets/aerosol to flame to be de-solvated, resulting in gaseous molecules/atoms.

Flame processes To excited free atoms, flame must break any molecules apart into discrete atoms. Potential Problems: 1.Atoms recombine readily in flame, especially with O 2. 2.If flame is too energetic, ionization of atoms can occur - won’t be detected. To excited free atoms, flame must break any molecules apart into discrete atoms. Potential Problems: 1.Atoms recombine readily in flame, especially with O 2. 2.If flame is too energetic, ionization of atoms can occur - won’t be detected. MX (g) → M (g) + X (g) M + O → MO M → M + + e - MX (g) → M (g) + X (g) M + O → MO M → M + + e -

Burner Head want a long optical pathlength.

Temperature of Some Flames FuelOxidantTemperature (K) H2H2 Air (20% O 2, 80% N 2 ) C2H2C2H2 Air H2H2 O2O C2H2C2H2 N2ON2O

Electrothermal Vaporization First demonstrated in 1961 by L'vov (USSR) Use electrically heated carbon furnace Excellent LOD First demonstrated in 1961 by L'vov (USSR) Use electrically heated carbon furnace Excellent LOD More sensitive than flame: Entire sample atomized at once Residence time of vapor in optical path >1 s LOD for Mg Flame: 0.1 ppm ETV: ppm - 20 pptr Potential problem: poor precision due to sampling variability

Cold Vapor (CV) Atomization Mercury Reduced by SnCl 2 Mercury Reduced by SnCl 2

Physical Interferences Droplet size from nebulizer depends on surface tension of solution. Organic solvent (alcohol, ester, ketone) can lead to smaller droplets, more intense signal. Droplet size from nebulizer depends on surface tension of solution. Organic solvent (alcohol, ester, ketone) can lead to smaller droplets, more intense signal.

Chemical Interferences Formation of compounds of low volatility, ex. CaSO 4 Ionization M  M + + e - Add ionization suppressors - create electron-rich environments. Ex, alkali metals Formation of compounds of low volatility, ex. CaSO 4 Ionization M  M + + e - Add ionization suppressors - create electron-rich environments. Ex, alkali metals

Spectral Interferences Two or more lines within monochromator’s spectral bandpass - requires appropriate resolution from diffraction grating (line spacing) Mn nm K nm Ga nm

Double-Beam Instrument A reference beam is used as a “blank” signal. To get %T measurement, you have to know what the measurement for 100% T is. Because the flame is always fluctuating, we need the reference beam to give a point of reference at any time during experiment - compensates for “drift”. A reference beam is used as a “blank” signal. To get %T measurement, you have to know what the measurement for 100% T is. Because the flame is always fluctuating, we need the reference beam to give a point of reference at any time during experiment - compensates for “drift”.

Background Correction Flame creates a messy background - scattering, absorbance by molecular species (oxides, hydroxides) Another wavelength is passed through the flame, its %T measured. Any loss of T is due to scattering, losses unrelated to absorption by analyte. The analyte %T is corrected for these losses. Flame creates a messy background - scattering, absorbance by molecular species (oxides, hydroxides) Another wavelength is passed through the flame, its %T measured. Any loss of T is due to scattering, losses unrelated to absorption by analyte. The analyte %T is corrected for these losses.

Atomic Fluorescence Spectroscopy Fundamental Process h + M → M* → M + h ' Photon emitted is not the same energy as the photon absorbed – it has lower energy fluorescence signal is directly proportional to concentration Enhanced sensitivity over AAS Signal collected at 90° angle - avoid having to filter out source radiation Fluorescence

Quantitative Analysis - Calibration Curve Test a series of standards and plot Abs v. conc, find LDR Run your sample and determine conc with line equation. Test a series of standards and plot Abs v. conc, find LDR Run your sample and determine conc with line equation. ppm =  g/mLppb = ng/mL For aqueous solutions (~1 g/mL)

Quantitative Analysis - Standard Additions Method Spike your standards into your samples - it’s all the same matrix. c x = bc s /mV x S = standard X = unknown From graph : C x = -(x-int)*c s /V x Spike your standards into your samples - it’s all the same matrix. c x = bc s /mV x S = standard X = unknown From graph : C x = -(x-int)*c s /V x