Flame photometry.

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Flame Tests for Ions Flame Tests Using an Improvised Alcohol Burner.
Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
1 A TOMIC SPECTROMETRIC METHODS PART 9. 2 Interferences : Four classes of interferences: 1-Spectral interferences 2-Chemical interferences 3- Refractory.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
Atomic Absorption Spectroscopy Yash Purohit Block 4.
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Atomic Absorption Spectroscopy (AAS) The Visible Spectra.
Molecular Fluorescence Spectroscopy
427 PHC. Introduction  Spectrometric methods are a large group of analytical methods that are based on atomic and molecular spectroscopy.  Spectroscopy.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Atomic Emission Spectroscopy (AES)
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic Absorption Spectroscopy (AAS)
Spectroscopy Chapter 7.
Instrumental Chemistry
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Biochemical instrumental analysis-2
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Flame Photometry Flame atomic emission spectrometry
Atomic Absorption Spectroscopy
Atomic Absorption Spectrophotometer
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
Flame Photometry The principles.
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
INTRODUCTION TO ANALYTICAL CHEMISTRY ERT 207 ANALYTICAL CHEMISTRY SEMESTER 1, ACADEMIC SESSION 2015/16.
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
QUANTITATIVE ANALYSIS Determining amount of ions present in samples.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Chapter 1: The Nature of Analytical Chemistry
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Atomic Emission Spectra
Satish Pradhan Dnyanasadhana College, Thane Department of Chemistry T
Flame Emission Spectrometry
Flame Photometer.
Spectroscopy Chapter 7.
Elemental composition
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
SPECTROPHOTOMETRY Applied Chemistry.
Atomic absorption spectroscopy
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Flame photometry

Introduction Principle : 1-flame photometry, a branch of atomic spectroscopy is used for determining the concentration of certain metal ions such as sodium, potassium, lithium, calcium, Cesium, etc. 2-The basis of flame photometric working is that, the types of metals are dissociated due to the thermal energy provided by the flame source. Due to this thermal excitation, some of the atoms are excited to a higher energy level where they are not stable.

3-The subsequent loss of energy will result in the movement of excited atoms to the low energy ground state with emission of some radiations as a wavelengths .The emitted wavelengths are specific for specific elements.

1. The solution containing metal to be measure is first aspirated into the burner. 2. The solvent then evaporated leaving fine divided solid particles. 3. This solid particles move towards the flame, where the gaseous atoms and ions are produced.

4. The ions absorb the energy from the flame and excited to high energy levels. 5. When the atoms return to the ground state radiation of the characteristic element is emitted. 6. The intensity of emitted light is related to the concentration of the element.

FP Components 1- Flame : A burner that provides flame and can be maintained in a constant form and at a constant temperature.  2- Nebuliser and mixing chamber: Helps to transport the homogeneous solution of the substance into the flame at a steady rate.  3- Monochromator : helps in isolating the wavelength to be measured from that of any other extraneous emissions.

4. Photo detector: Detect the emitted light and measure the intensity of radiation emitted by the flame. That is, the emitted radiation is converted to an electrical signal with the help of photo detector. The produced electrical signals are directly proportional to the intensity of light.

Flame (burner) Burner used in FP should have the following properties: The flame should have ability to evaporate the solvent to give a residue(deposit) - It should convert this residue to gases state atom and finally into individual atoms

The effect of flame depend on the temperature of flame and this temperature can be monitored by following method: Fuel to air ratio Type of solvent for preparing sample solution Amount of solvent which is entering to flame Type of burner used in FP

Flame (burner) Flame photometry employs a variety of fuels mainly air, oxygen or nitrous oxide (N2O) as oxidant. Burners are of two types: Total Consumption Burner and Premix or Laminar flow Burner.

The various processes in the flame are discussed below: Desolvation: The liquid solvent is evaporated, and the metal particles are dehydrated by the flame Vapourisation: The sample vaporises to a gas . Atomization: Reduction of metal ions in the solvent to metal atoms by the flame heat.

Excitation: The electrostatic force of attraction between the electrons and nucleus of the atom helps them to absorb a particular amount of energy. The atoms then jump to the exited energy state. Emission process: Since the higher energy state is unstable the atoms jump back to the stable low energy state with the emission of energy in the form of radiation of characteristic wavelength, which is measured by the photo detector.

Types of FP 1- Direct type: Standard solution of Na & K are atomised or aspirated into flame to provide a series of meter readings in which our unknown is going to compared with.

Direct type disadvantages 1- Any minor fluctuations in air, gas pressure might change response of instrument and then cause errors. 2- Separate analyses and sometimes separate solutions must be made for Na and K.

2- Internal standard method: Another element (Li) is added to all standards, blanks and unknowns in equal concentration. This element has a criteria of : * high emission intensity. * Is absent from biological fluid.

Applications 1- Determine the availability of alkali and alkaline earth metals which are critical for soil cultivation. 2- In agriculture, the fertilizer requirement of the soil is analyzed by flame test analysis of the soil.

3- In clinical field, Na+ and K+ ions in body fluids, muscles and heart can be determined by diluting the blood serum and aspiration into the flame. 4- Analysis of soft drinks, fruit juices and alcoholic beverages can also be analyzed by using flame photometry.

Advantages: 1.Simple quantitative analytical test based on the flame analysis. 2.Inexpensive. 3.The determination of elements such as alkali and alkaline earth metals is performed easily with most reliable and convenient methods. 4.Quite quick, convenient, and selective and sensitive to even parts per million (ppm) to parts per billion (ppb) range.

FP suffer the same level of interferences as AAS from: 1- Anion due to complexation (chemical interference). 2- Matrix interference. 3- Burner interference. 4- Ionisation interference. 5- emission interference.

limitations Alteration of light emission because of altered flame temp. It needs perfect control of flame temperature. Interference by other elements is not easy to be eliminated Heavy and transition metals , the number of absorption and emission lines is enormous and the spectra are complex Inadequate selectivity of WL. Differences in viscosity between standards and sample.

Advantages of AAS over FP 1- Sensitivity. 2- Applicability. 3- Smaller flame effect. 4- Less interference from other cations.

AAS Vs PF