Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia.

Slides:



Advertisements
Similar presentations
Pulse Oximetry Karim Rafaat, MD.
Advertisements

Pulse oximetry Pulse oximeter measures
Transport of gases. Mechanism of gas transport Primary function is to obtain oxygen for use by body's cells & eliminate carbon dioxide that cells produce.
Oxygen and Carbon Dioxide transport in the blood
OXYHEMOGLOBIN DISSOCIATION CURVE Chemeketa Community College.
Blood Gas Transport Dr Taha Sadig Ahmed Physiology Dept College of Medicine King Saud University Riyadh.
GAS TRANSPORT OXYGEN(O2) & CARBONDIOXIDE(CO2)
Dr Archna Ghildiyal Associate Professor Department of Physiology KGMU Respiratory System.
Vital Signs Pulse Oximetry. Bellringer Think back to the last time you or a family member went to see a doctor. What vital signs ( temperature, oxygen.
Review Objective 104. What are the distinctions between systemic and pulmonary circulatory patterns?
Pulse Oximetry Theodore Maniatis MD Director of Critical Care.
Pulse Oximetry Optional, AEMT.
Blood Gases: Pathophysiology and Interpretation
South Taiwan University Institute of Mechanical Engineering How to Read SpO 2 and yoga breath’s Reference Prof. :Yi-Chu Hsu Name :Ruei-Cheng Liu Student.
1 Respiratory system L4 Faisal I. Mohammed, MD, PhD University of Jordan.
14-May-15Najwa subuh- MSN in Pediatric1. 14-May-15Najwa subuh- MSN in Pediatric2 A pulse-oximeter is a device that measures the amount of saturated hemoglobin.
Respiratory System Gas Transport.
Physiology Blood Buffer System Behrouz Mahmoudi.
Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia.
Transport of O 2 in blood: 1. Some dissolved  1.5% at normal atmospheric pressure 2. Most combined with hemoglobin  98.5%
1 Using PPG Morphology to Detect Blood Sequestration Stephen Linder Suzanne Wendelken Susan McGrath.
External and Internal Respiration. Learning Outcomes: C10 – Analyse internal and external respiration –State location –Describe conditions (ph, temperature)
Week 5 Oxygenation and Tissue Perfusion. Learning Objectives 1.Describe and list factors that affect oxygenation and tissue perfusion. 2. Explain common.
Respiratory System Physiology
Gas exchange.. Key terms: Gas exchange refers to the exchange of gases, namely oxygen and carbon dioxide and relies on a process called diffusion. Diffusion.
Respiratory Regulation During Exercise
Pulse oximetry is the noninvasive measurement of arterial blood oxygen saturation and heart rate. The Pulse Ox use a spectrophotometric probe. The pulse.
ONTARIO BASE HOSPITAL GROUP ADVANCED ASSESSMENT Principles Of Oximetry QUIT 2007 Ontario Base Hospital Group.
Chapter 11 Noninvasive Monitoring in Neonatal and Pediatric Care.
Jonathan Meyer Bogdan Dzyubak Matt Parlato Joe Helfenberger.
Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia.
1 Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: , Transcutaneous measuring principles – tc and saturation.
Transport of Oxygen and carbon dioxide
Arterial blood pressure is a measure of the pressure exerted by the blood as it flows through the arteries. The systolic pressure is the pressure of the.
Non-Invasive Oxygen Monitoring Pulse Oximetry & Conjunctival Oxygen Monitoring.
Patient Monitoring Stuart Nurre, MS, R.R.T.. Oxygenation Goal of respiratory therapy is return the patient to a normal oxygenation status, while minimizing.
18.5 TRANSPORT Blood and Circulation. Mammalian Transport system  The transport system in humans is typical of all mammals. Materials are transported.
EE 4BD4 Lecture 19 Pulse Oximeter 1. Utility Replace direct observation of blood oxygenation (pallor, cyanosis) or frequent arterial blood analysis Based.
Copyright © 2009 Pearson Education, Inc., publishing as Benjamin Cummings Simple Review.
PULSE OXIMETRY. Introduction Pulse oximetry was developed in 1972 Pulse Oximetry is utilized as a quick, easy and non invasive way of assessing a patients.
Transport of oxygen and carbon dioxide. Session format At the end of this lecture the student will be able to: understand how O 2 and CO 2 are transported.
South Taiwan University Institute of Mechanical Engineering
Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia.
Resp.2 Oxygen dissociation curve Resp.2 Oxygen dissociation curve.
Copyright © 2005 Pearson Education, Inc. publishing as Benjamin Cummings Concept 42.7: Respiratory pigments bind and transport gases The metabolic demands.
Pulse Oximetry Key Terms. Capillaries Tiny blood vessels that allow for exchange of nutrients and gases between the blood and the body cells.
Respiratory Physiology Division of Critical Care Medicine University of Alberta.
The Respiratory System Group Members: Abby Ridley-Kerr Lia Kato Sasha Yovanovich Shelby LaRosa.
Pulse Oximetry. What is a Pulse Oximeter? A device that provides a non-invasive (does not break the patient ’ s skin or body openings) method of allowing.
Oxygen Transport by Blood LECTURE 20 By Dr. Khaled Khalil Assistant Professor of Human Physiology.
Pulse Oximetry Optional, AEMT.
Biochemical role of Hemoglobin
Lung Volumes and Lung Function Testing 
O2 and CO2 levels in blood.
RESPIRATORY SYSTEM LECTURE-6 (GAS TRANSPORT)
Oxygen and Carbon dioxide Transport
Human respiratory system
The transport of oxygen
D.6: Transport of respiratory gases
Physiologic signals Lecture 5.
Faisal I. Mohammed, MD, PhD
Transport of Respiratory Gases
OXYGEN(O2) & CARBONDIOXIDE(CO2)
Cardiac Output O2 Saturation Capillary Refill
External and Internal Respiration
Describe the differences between mRNA and tRNA
Cyanosis is the bluish or purplish discolouration of the skin or mucous membranes due to the tissues near the skin surface having low oxygen saturation.
Monitoring in anesthesia
Oxygen and Carbon dioxide Transport
TRANSPORT OF OXYGEN AND
Presentation transcript:

Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia

 The pulse oximeter produces both a red light at 660 nm ( which we can see) and infrared light at 910 nm (which we cant see).  These shine through a thin piece of tissue and the pulse oximeter measures the relative absorption of the two wavelengths. From this it calculates the oxygen saturation, i.e. the ratio of oxyhaemoglobin to deoxyhaemoglobin, from absorption curves programmed into the device.

 What makes the pulse oximeter so useful is that it only looks at the pulsatile component of the light absorption, not the background level. The pulsatile change in tissue absorption is due to blood entering the arterioles and therefore the pulse oximeter measures arterial oxygen saturation (Sa02%).

 Oxygenated hemoglobin absorbs more infrared light and allows more red light to pass through. Deoxygenated (or reduced) hemoglobin absorbs more red light and allows more infrared light to pass through.  Red light is in the nm wavelength light band. Infrared light is in the nm wavelength light band.

 Pulse oximetry uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow.  Typical adult/pediatric sites are the finger, toe, pinna (top) or lobe of the ear.  Opposite the emitter is a photodetector that receives the light that passes through the measuring site.

 The pulse oximeter measures the adequacy of arterial oxygenation. Pulse oximeters are very useful monitors in anesthesia for two reasons.  Firstly, arterial hypoxaemia is the final "common pathway" for many problems that occur in anesthesia such as hypoventilation, airway obstruction and equipment-related problems. A pulse oximeter can therefore pick up problems of different etiologies.  Secondly, hypoxia is a common and serious problem so noticing it early will prevent disasters. A pulse oximeter will detect hypoxemia long before the patient becomes cyanosed ( turns blue).

 The normal values for healthy individuals are %  Please never forget that a reading of 90% correlates with an arterial oxygen saturation of 60%. This value is what we call the edge of the cliff. From 90% on down the patient’s oxygen saturation will drop rapidly.  Also remember that values under 70% ( 40% arterial saturation) are not reliably correlated with arterial oxygen saturation.

Or an increase in Temperature

 When the pH is decreased (increased acidity), the affinity of hemoglobin to oxygen is decreased and thus unloading is easier. This is called the Bohr effect. Thus at the tissue level where the pH is low (high level of carbon dioxide), cellular oxygenation is facilitated. As for the oxyhemoglobin dissociation curve, this is shifted towards the right.  The same effect can be seen by an increase in temperature. Again this temperature effect helps in the unloading of oxygen at the tissue level.  red blood cells lack mitochondria, energy is obtained through the anaerobic metabolism of glucose. One metabolite of this reaction is 2,3-diphosphoglyceric acid (2,3- DPG). 2,3-DPG production is increased by an increase in deoxyhemoglobin production. 2,3-DPG, in turn, increases the stability of deoxyhemoglobin and thus shifts the dissociation curve to the right.

 If the curve is shifted to the right then we can accept lower oxygen saturations as these correlate with higher arterial oxygen saturation.  This issue should not be relevant to the sedationist except in an emergency let us say a resuscitation following cardiac arrest where the patient may have some acidosis or in a case of malignant hyperthermia where you have increased body temperature.

 You must put the probe on in the correct orientation.  That is the part with the shining red light sits over the nail bed not the dorsal aspect of the finger.  Pulse Oximeters measure pulsatile blood flow. Therefore if blood flow is restricted [i.e. The patient is cold or for some other reason there is not good perfusion to the fingers] you will not get an accurate reading.