PipeGuard by MAGAL The Pipelines Security Solution for BOTAS MAGAL proprietary and commercially secret information. Not to be copied to third parties without.

Slides:



Advertisements
Similar presentations
Remote Automation and Monitoring: PLC or RTU. Key Points PLCs and RTUs are similar devices with somewhat differing functionality.
Advertisements

Lecture 20 Dimitar Stefanov. Microprocessor control of Powered Wheelchairs Flexible control; speed synchronization of both driving wheels, flexible control.
Modelling and Simulation 7. September 2014 / Dr. –Ing Naveed Ramzan 1 Instrumentation and control Department of Chemical Engineering, U.E.T. Lahore Pakistan.
Public Safety Related Applications Summary July, DRAFT -
SensMax People Counting Solutions Visitors counting makes the most efficient use of resources - people, time and money, which leads to higher profits in.
Ultra-Wideband Technology
Joe Killins & Associates, LLC Pipelines & Risk Based Management How Safe is Safe?
VSE Corporation Proprietary Information
1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property.
You Can Measure the Benefits… Solid Applied Technologies Sewer Level Monitoring.
A Mobile Ad hoc Biosensor Network Muzammil KP S7,ECE Govt. Engg. College, Wayanad.
Presented by: Team NightStriker Course: EDSGN Section: 006.
Introduction to Wireless Sensor Networks
Smart Sensor Technology for Gas Pipeline Monitoring
Airmux-500 HPMP – 2011 Slide 1 Solution Note: Railway Crossing Accident Prevention Customer Type: Intercity train Strategic Sales Development.
1 Vertically Integrated Seismic Analysis Stuart Russell Computer Science Division, UC Berkeley Nimar Arora, Erik Sudderth, Nick Hay.
Monitoring Vibration on Tunnel Fans Safety First The worlds developing infrastructure creates many technical challenges for engineering and construction.
1 6/11/ :41 Chapter 10Wireless LANs1 Rivier College CS575: Advanced LANs Chapter 10: Wireless LANs.
OTHER RECOMMEDATIONS. Increasing Spatial Resolution (Low bandwidth) Increasing Spatial Coverage (High bandwidth) Collective and Local Processing per-node,
Company Profile.
References. Moscow SafeCity Over 175,000 CCTV cameras in Moscow, controlling over doorways and mass circulation areas in ten districts. Vandal-resistant.
TIMKEN Bearing Diagnostics and Prognostics Using PI Reducing Unplanned Downtime Rich Browner - Program Manager Reliability Solutions The Timken Company,
Network Topology. Physical Topology The term physical topology refers to the way in which a network is laid out physically. Two or more devices connect.
Network Topologies.
Defence and Communications Systems EADS Secure Networks The role of TETRA in Homeland Security.PPT /HVi The Role of TETRA in a Holistic Homeland.
Trends in seismic instrumentation Based on the book Instrumentation in Earthquake Seismology Jens Havskov, Institute of Solid Earth Physics University.
Year 2006 Report “Better” Managed and Controlled Transmission Grids using Advanced Technological Concepts Aty Edris EPRI Power Delivery & Markets
Integrated Vehicle Tracking and Communication System.
Development of a Technique for HFCV Safey Assessment
1 Chapter 2: LAN Standards, Physical Connectivity, and Media Access.
Global Design Effort - CFS for Asian Single Tunnel Configuration Design Progress Masanobu Miyahara KEK.
DC Superconductor Cables for Long Distance Transmission 2009 Mid-America Regulatory Conference Traverse City, MI June 14-17, 2009.
SMUCSE 8394 BTS – Devices II Sensors Detection, Surveillance, Protection.
PRESENTED BY: SAURAV SINGH.  INTRODUCTION  WINS SYSTEM ARCHITECTURE  WINS NODE ARCHITECTURE  WINS MICRO SENSORS  DISTRIBUTED SENSOR AT BORDER  WINS.
Ruslan Masinjila Aida Militaru.  Nature of the Problem  Our Solution: The Roaming Security Robot  Functionalities  General System View  System Design.
Sluzek 142/MAPLD Development of a Reconfigurable Sensor Network for Intrusion Detection Andrzej Sluzek & Palaniappan Annamalai Intelligent Systems.
Radar Video Surveillance
The Oregon Road User Fee Concept and Pilot Program Presented to National Surface Transportation Infrastructure Financing Commission Washington DC September.
IN PARTNERSHIP WITH EVRIKA. IN PARTNERSHIP WITH EVRIKA.
Power Plant Construction and QA/QC Section 5.4 – Key Systems and Components Engineering Technology Division.
EMZA Making Sense Of your Asset protection. Emza Visual Sense WiseEye™ New Outdoor Intrusion Detection System 2009.
A-Gas II- Video Detection for Damage Prevention Kickoff Meeting Kickoff Meeting July 27, 2009 New York, NY P&L E-Communications, LLC.
Topics of presentation
E VERY L IFE H AS A P URPOSE… FlameGard 5 MSIR Flame Detector.
UNIT -1. DATA COMMUNICATIONS The term telecommunication means communication at a distance. The word data refers to information presented in whatever form.
© 2006 Cisco Systems, Inc. All rights reserved. Implementing Secure Converged Wide Area Networks (ISCW) Module 6: Cisco IOS Threat Defense Features.
Geo-localisation in CERN’s underground facilities CERN has recently deployed a digital radio network, based on TETRA technology, to be used by the Fire.
WIRELESS INTEGRATED NETWORK SENSORS
Name Of The College & Dept
I & C.
Wireless Sensor Networks
Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
Sicherheitsaspekte beim Betrieb von IT-Systemen Christian Leichtfried, BDE Smart Energy IBM Austria December 2011.
BORDER SECURITY USING WIRELESS INTEGRATED NETWORK SENSORS (WINS) By B.S.Indrani (07841A0406) Aurora’s Technological and Research Institute.
ARM and GPS Based Transformer monitoring system with area Identification Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
Flame & Smoke Detection System Flame & Smoke Vision Detection is an intelligent vision-based analytics system which can timely detect suspicious fire or.
Wireless Sensor Network: A Promising Approach for Distributed Sensing Tasks.
HCNA-UC HCNA-UC certification validates the knowledge and skills required for basic configuration and maintenance of small to medium-sized enterprise unified.
SCADA Supervisory Control And Data Acquisition Pantech Solutions Here is the key to learn more.
Signal and Image Processing Lab
Intelligent Video Surveillance – The End of CCTV
Huawei Digital Pipeline Solution
Introduction to Wireless Sensor Networks
Network for connecting robots, sensors, drones, unmanned surface
Student’s Name with USN No.
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
169 South Main Street, New City, NY 10956
NFMT Quick Fire Presentation: Solving Your Peace of Mind Problem Presenter: Cam Rogers Director of International & Western US Sales June 12, 2019.
MicroToken Exchange Data Security Solutions
Wireless LAN.
Presentation transcript:

PipeGuard by MAGAL The Pipelines Security Solution for BOTAS MAGAL proprietary and commercially secret information. Not to be copied to third parties without MAGAL’s prior written permission

PipeGuard’s Background Securing the pipes has been an unanswered challenge till nowAlthough being recognized as a strong need by the oil & Gas industry for years - Securing the pipes has been an unanswered challenge till now. identification Technion (Israel institute of technology).Magal has identified that need, and has implemented a unique identification technology developed in the Technion (Israel institute of technology). in-house command & control systemTogether with unique short range communication technology - and in-house command & control system – the PipeGuard patent based comprehensive solution.

Regional Theatre during Digging Event 3 – 20 Km PipeGuard sensing unit Pipeline existing regional station Pipeline control center Pipeline Patrol vehicle Pipeline Patrol vehicle Wireless LAN, Video, GPS, data

PipeGuard is good for: The PipeGuard was find suitable to the following applications: Oil & Gas industry: –Theft –Terror –3 rd party Underground Data transfer highways (buried fiber optics). Tunnels digging detection (prisons)

PipeGuard main Characteristics Non-exposed components.Non-exposed components. preventionDamage prevention by alarming at preparation phase. recognition capabilityInherent recognition capability – of more then 95%. locationAccurate location. all soil typesAll weather all soil types operation. System redundancySystem redundancy. AdaptiveAdaptive to typical local signals and noise. Fits all pipesFits all pipes – from existing and operational to new under construction ones.

Basic logic flow of a “sensing unit” Seismic signature bank Signal analysis = = ALARM message Discard NO YES Output

PipeGuard Uniqueness Geo-Phones) identification capabilityCombination of seismic sensors (Geo-Phones) with an advanced identification capability. autonomousThe Discrete buried sensing units are autonomous. Signal analysis is fully conducted in every unit, thus “Alert message” is forwarded to the control room only when the signal is recognized as “real”. Wireless Communication is based on short range transmission to both neighboring units, and on to the nearest pumping station to avail duplex communication chain. The principal of continuously signal-monitoring enables adaptive performance and time enhancement..

Conceptual Comparison: critical parameters Detecting wireFiber-optic wirePipeGuardCharacter# NoneMedium - LowVery good (Pd>95%)Intrusion identification1 NoneLowVery goodMultiple event2 Very lowMediumVery lowFAR3 MediumHigh Location accuracy4 NoneMediumgoodDamage prevention5 Low. Failure of the wire will fail the whole system Low. Failure of the Fiber- Optic wire will fail the whole system High. System is constructed on independent detectors Robustness6

√ X Schematic Summary

System installation

System Installation & Components Signal analyzer Transceiver cm Ground level “sensing unit” Power source

Principal of Phased Array Coverage (Top view) Shape of coverage zone Geo-phones array (Example only) Geo-phones array (Example only) 150 meter m Shape of coverage zone 100 m

System Installation Concept 1 Km meters Ground level Sensing units Discrete Sensing units

Wireless Configuration Concept Scheme Ground level

Wire Configuration Concept Scheme 60 – 80 cm Ground level 1 – 5 m cm

Control Center Information during Alert 1.Alert from sensor # 347: Digging with Pd of 98%. 2.Position is 5364/7764 (UTM). 3. Time of event: 12: Closest patrol call-sign “Charlie 21” 5. Optional courses or response (based on pre-planned checklist).