II. Dimensioning of a Branched Distribution System Main Procedures 1. Determination of the design water flowrates 2. Determination of the pipe diameters.

Slides:



Advertisements
Similar presentations
Design of W.W. Collection System
Advertisements

CHAPTER FOUR Stream flow measurement
Fluid Mechanics 07.
Experiment 8 : Minor Losses
Heating and Air Conditioning I
HYDRAULIC 1 CVE 303.
Topic I.8. Water Supply Networks: Kinds, Structures and Design
CHAPTER 6: Water Flow in Open Channels
Biet Qad Village Climate Relative Humidity Evaporation.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering AguaRed.
HEC-RAS.
1 Topic I. 9. Water Supply Networks Dimensioning Determination of Design Water Flowrates (Water Quantities) Design Flows Division §Take off (distributed)
Hydraulic Modeling of Water Distribution Systems
Notes on Hydraulics of Sedimentation Tanks. A Step by Step Procedure.
Micro Design. System Capacity D = gross application for what ever time period ( hrs, day or days) T= hours in time period used to decide “D” (max.
“Design of Water Supply and Sewer Systems” IV. Water Tank (Service Reservoir). Dimensioning and Constructing (Drawing 4) Main Procedures 1. Determination.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Pipeline systems.
Hydraulic Engineering
UNIFORM FLOW AND DESIGN OF CHANNELS
Water piping design.
“Design of Water Supply and Sewer Systems” Teaching language: English Main TopicsMain Topics A.Design of Water Supply Systems I.Water Demand and Plan of.
Lecture 1 Water Distribution Systems
CHAPTER 2: Flow through single &combined Pipelines
Hydraulic Engineering
o To facilitate the process of providing consumers with clean water. o Provide quantity that suit their needs and control the quality of this water because.
Water network in Meithalun Prepared by:-- -Khalid Nairat -Ghaith Daraghmeh -Mohammed Daraghmeh Supervisor:-- Dr. Amal Al Hudhud An – Najah National University.
Unit: V-Flow Through Pipes. Flow Through Pipes  Major Energy Losses - Darcy-Weisbach Formula - Chezy’s Formula  Minor Energy Losses -Sudden expansion.
Prepared By Abeer Mohammed Ala' Snober Suhad Dwaikat Wajeha Ma'ani Submitted to Dr. Amal Al-hudhud.
An-Najah National University Civil Engineering Department Analysis of the Water Distribution Network of howara- Nablus Submitted by: Rami Ahmad Mohammed.
© Irrigation Association Effect of Irrigation. © Irrigation Association Calculate Hydraulic Requirements Chapter 4:
For calculating energy loss to friction the special case of the flow of water (Newtonian fluid) in pipeline systems. Limited to the flow of water in pipe.
Introduction Before going ahead into our project I want first talk in a brief about the importance of water, water is essential to sustain a life and.
Importance Of Water Water is life. Living on the earth may be impossible without adequate water quality and quantity. Water makes up more than half of.
Prepared by: Ayah Yasin SUPERVISOR Dr. HAFEZ SHAHEEN PROJECT 2 : FALL Wastewater Collection system for Anin 1.
Lesson 23 HEAD LOSS DEFINE the terms head loss, frictional loss, and minor losses. DETERMINE friction factors for various flow situations using the Moody.
Outline Introduction. Population Analysis Study Area Objectives
An-Najah National University Civil Engineering Department
Background 1. Energy conservation equation If there is no friction.
Basic Hydraulics: Culverts – I
Water Resources System Modeling
Basic Hydraulics: Hydraulic continuity concepts
Topic II. 8. Hydraulic Dimensioning of Sewers
1 Topic I.10. Service Reservoirs: Kinds, Structures and Volume Main Functions of the Service Reservoirs: §To insure the necessary head at the water distribution.
Sanitary Engineering Lecture 7
Lecture (11): Water Distribution Systems
CE 3372 Water Systems Design
CE 3372 Water Systems Design
Plumbing system fundamental and design course
DZ11 Qweisma.
DZ01 – Marka D B E C B G A B C.
EXERCISES Two water reservoirs are connected by a pipe 610m of 0.3m diameter, f’=0.038 and the flow produced by the difference in water surface elevations.
UNIFORM FLOW AND DESIGN OF CHANNELS
Design of Cold Water Networks
Analysis and Design of the Water Distribution Network for Teeba area,Nablus By Ranin Abu Gharbieh Under supervision of Dr. Mohammad Almasri.
Tamer Sultan Mousa Ziadeh
Coursework guidelines
ME444 ENGINEERING PIPING SYSTEM DESIGN
Prepared By : Osama amr Qutayba mElhim
An-Najah National University Faculty of Engineering
Selat al-daher water distribution network
Topic II. 6. Determination of Design Runoff Quantity: Rational Method
Chapter 5. Pipe System Learning Outcomes:
CHAPTER FOUR Stream flow measurement
Design of A Sewer Network For Siries Village
CHAPTER FOUR Stream flow measurement
50 m EML3015C Thermal-Fluid I Fall 2000 Homework 4
CHAPTER FOUR Stream flow measurement
Analysis of the Water Distribution Network of
An-Najah National University Civil Engineering Department Graduation project  Hydraulic analysis & Redesign of Al-Masaken & Old Askar Camp Water Supply.
Prepared By Waleed Osama Alkilani Anas Ahmad Khalid
Presentation transcript:

II. Dimensioning of a Branched Distribution System Main Procedures 1. Determination of the design water flowrates 2. Determination of the pipe diameters 3. Determination of the tank elevation and the water head (pressure) at the crossroads “Design of Water Supply and Sewer Systems”

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates General information 1. The distribution system is designed for the most unfavorable conditions: a fire could possibly burst out unfavorable conditions: a fire could possibly burst out during the hour of maximal consumption. during the hour of maximal consumption. 2. Only the main branches are dimensioned. The distribution branches are accepted to have a diameter of distribution branches are accepted to have a diameter of 80 mm for settlements with a number of population 80 mm for settlements with a number of population under under The distribution system is dimensioned section by section. A section is a part of a branch, between two section. A section is a part of a branch, between two crossroads, conveying a constant water quantity. crossroads, conveying a constant water quantity.

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates Design water flowrates is the design water flowrate of a section, l/s is the maximal hourly flowrate, passing through the dimensioned section of the distribution system during normal operation, l/s is the design fire flowrate in the section, l/s for all sections of the main branches

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates is the take off flowrate consumed within the limits of the designed section, l/s is the crossover flowrate of the section (equal to the sum of the take off flowrates of the sections, fed by the designed one), l/s is the crossover flowrate of the section (equal to the sum of the take off flowrates of the sections, fed by the designed one), l/s is the concentrated flowrate, consumed in the limits of the section and afterwards, l/s

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates is the coefficient of equivalent distribution flowrate; =1 for branched distribution system dimensioning is the specific water quantity of the distribution system l/sm is the reduced length of the designed section, m is the maximal hourly demand of the settlement, l/s is the sum of the maximal hourly concentrated consumptions of the settlement (hospital, restaurant and factory), l/s is the reduced length of the whole distribution system, m

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates is the real length of the section, m is reducing coefficient, =1 for bilateral take off along the length of the section, =0.5 for unilateral take off, =0 for no take off (transit flows) is the total take off flowrate of the designed section, l/s is the total reduced length of the section (it includes the proper reduced length and the reduced lengths of the sections fed by the designed one), m

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates Water Flowrate Plan of the Distribution System (Drawing 2)

II. Dimensioning of a Branched Distribution System Topic II.1 Determination of the Design Water Flowrates Contents of the Water Flowrate Plan   Numeration of the quarters   Numeration of the crossroads   Numeration of the branches   Real, reduced and total reduced lengths of the sections, m   Total take off flowrate of the sections, l/s   Concentrated flowrate of the sections, l/s   Fire flowrate of the sections, l/s

II. Dimensioning of a Branched Distribution System Topic II.2 Determination of the Section Diameters Pressure flow Hydraulic parameters (6)   Flowrate – Q   Velocity – v   Diameter – D   Hydraulic gradient – I   Head loss – h   Roughness factor - n Available equations (3) Continuity equation Head loss equation Chezy - Maning equation Accepted parameters: Q, v, n = for steel pipes Calculated parameters: D, I, h

II. Dimensioning of a Branched Distribution System Topic II.2 Determination of the Section Diameters Velocity – accepted range of variation   Mean economical velocities (for metal pipes, normal operation) v = 0.90 – 1.40 m/s   Lower limit for velocities in the pipes v min = 0.3 m/s   Upper limit for velocities in the pipes v max = 2.00 m/s – for the network v max = 3.00 m/s – for the feeder

II. Dimensioning of a Branched Distribution System Topic II.2 Determination of the Section Diameters Additional conditions  Critical dynamic head H min H min = 14 m for normal operation conditions (average two-floor building construction of the settlement) H min = 14 m in case of fire H min = 14 m in case of fire  Minimal diameter of a main branch section D min = 100 mm  Equation of head loss balance (looping the system) is the sum of the head loss in the clockwise-water-movement is the sum of the head loss in the clockwise-water-movement sections of a system loop, m sections of a system loop, m is the sum of the head loss in the counter-clockwise-water- is the sum of the head loss in the counter-clockwise-water- movement sections of the same loop, m movement sections of the same loop, m misbalance of a loop, m misbalance of a loop, m Acceptable misbalance of a loop: for normal operation (maximal hourly demand) in case of fire (maximal hourly demand + fire quantity) The balance must be achieved for both loops at the same time. by changing diameters of some sections of the branches.

II. Dimensioning of a Branched Distribution System Topic II.2 Determination of the Section Diameters Dimensioning Table Note: Diameters are to be found for Q no, accepting the velocity in the range of the mean economical limits. Then v f and I f are found with the obtained diameter and Q d.

II. Dimensioning of a Branched Distribution System Topic II.3 Determination of the Water Tank Elevation and the Head (Pressure) at the Crossroads

II. Dimensioning of a Branched Distribution System Topic II.3 Determination of the Water Tank Elevation and the Head (Pressure) at the Crossroads - ground elevation of the water tank, m (coincides with the maximal water level elevation – sunken with the maximal water level elevation – sunken type service reservoir) type service reservoir) - ground elevation of the critical point, m - critical (minimal allowable) pressure, = 14 m - sum of the head loss from the critical point to - sum of the head loss from the critical point to the beginning of the distribution system, m the beginning of the distribution system, m - head loss in the feeder, m - usable depth of the tank, m = 4.5 – 5 m

II. Dimensioning of a Branched Distribution System Topic II.3 Determination of the Water Tank Elevation And the Head (Pressure) at the Crossroads Defining the Position of the Critical Point When the slope of the terrain is uniform, usually the critical point (crossroads) is the one of the highest elevation (case 1), or the most remote one from the Tank (case 2). Compare: Z i +Σh i-1 with Z 1 The maximal value defines the position of the critical point.

II. Dimensioning of a Branched Distribution System Topic II.3 Determination of the Water Tank Elevation And the Head (Pressure) at the Crossroads Defining the Feeder Head loss The head loss in the feeder is calculated by the following iterative procedure: procedure: 1.Assume the value of the head loss in the feeder h’ 1-T = m 2.Calculate the tank level as a first approximation Z 1,T and find the position of the tank on the map horizontals. 3.Trace the feeder from the tank to the settlement as a straight line (the shortest way). Measure the length of the feeder from the map L 1. 4.Calculate the head loss in the feeder as a second approximation h” 1-T. If it is lower than the accepted one (h’ 1-T ) the elevation of the tank is well defined. Otherwise, repeat the procedures from 2 to 4, increasing the tank elevation by the difference between the calculated and assumed values of the feeder head loss. Finally, find the elevations of the head line and the pressure at the crossroads:

II. Dimensioning of a Branched Distribution System Vocabulary of the Terms

II. Dimensioning of a Branched Distribution System Vocabulary of the Terms