1 Powering Tests and Safety Electrical Safety Hugues Thiesen Power Converter Group.

Slides:



Advertisements
Similar presentations
Basic safety rules and procedures for controlling hazardous energy
Advertisements

Introduction Most accidents are caused by the uncontrolled release of hazardous energy. Many of these accidents can be prevented by proper lock-out/tag-out.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
New HV test specification for the LHC N. Catalan for the EI section.
TE-MPE –TM, 16/05/2013, Mateusz Bednarek, TE/MPE-EE ELQA testing during and beyond LS1.
LHC HARDWARE COMMISSIONING SAFETY TRAINING DAY S. Claudet (AT-ACR-OP) With great help from G. Lindell (Safety commission) CRYOGENICS.
Standard 29 CFR Part Lockout / Tagout. Lockout/tagout agenda In today’s presentation, we will discuss the following: Terminology Energy sources.
Establishing an Electrically Safe Work Condition May is Electrical Safety Month Training A product of the EFCOG Electrical Safety Task Group.
Acknowledgments: O.Aberle – F.Bertinelli – J.C.Billy - O.Capatina - J.Casas - L.Ceccone - S.Claudet J.Coupard - K.Dahlerup - R.Denz - K.Foraz - J.J.Gras.
1 Copper Stabilizer Continuity Measurement Project CSCM Mini Review Powering Implementation H. Thiesen 30 November 2011.
Session th January 2010 R.Schmidt TE/MPE Hardware Commissioning 2010 and beyond R.Schmidt.
LARP Collaboration April 26 th 2006 The Commissioning of the Technical Systems of LHC 1.The final validation that all the collider components/systems.
Workshop Chamonix XIV Shortcuts during installation and commissioning: risk and benefit H. Gruehagen, G. Riddone on behalf of the AT/ACR group 18 January.
Chamonix Risks due to UPS malfunctioning Impact on the Superconducting Circuit Protection System Hugues Thiesen Acknowledgments:K. Dahlerup-Petersen,
1 Second LHC Splice Review Copper Stabilizer Continuity Measurement possible QC tool for consolidated splices H. Thiesen 28 November 2011 K. Brodzinski,
LHC Hardware Commissioning Review May 2005, CERN, 1211 Geneva 23 1 LHC Hardware Commissioning Review Contribution ID: 20 – Quality assurance and.
HC Review, May 2005 Hardware Commissioning Review Hardware Commissioning Review Quality Assurance and Documentation of Results Félix Rodríguez Mateos,
1 Copper Stabilizer Continuity Measurement Project Copper Stabilizer Continuity Measurement Status & Plans – May 2011 MPE-TM – 12 May 2011 M. Koratzinos,
V.Montabonnet - Safety during Hardware Commissioning 18 October Contents  Electrical circuits in the LHC context  Electrical Hazards  Preventions.
7/23/ J.Coupard. 1) Cryogenic risks 2) Cryogenic phases from RT/floating to nominal and additional safety rules A. Sectors warmed-up to RT or considered.
AT-MEL-PM, R. Denz, CERN, CH-1211 Geneva 23 1 QPS system and its risks  Principal risks  General remarks  Quench heater circuits  Quench detection.
ESRF PSG safety for equipment and personal related to power converters 2 nd POCPA 15th of June 2010 Jean-François Bouteille.
For more info:
Procedures to protect employees and co-workers Basic Lockout Guidelines Procedures to protect employees and co-workers.
M. POJER, ON BEHALF OF THE USUAL BUNCH OF SUSPECTS… S UPERCONDUCTING CIRCUITS RE - COMMISSIONING AFTER THE 2011 C HRISTMAS BREAK.
Hardware Commissioning  Preparation Documentation MTF Programme  Status The Review The commissioning activity in Resources  Outlook The new.
Review of Sector th of February Electrical Safety for the interventions during Hardware Commissioning of LHC Anne Funken, TS-ICC.
Power Converters and DC cablesSlide 1/.. LHC - HC review Hugues THIESEN – AB/PO Thursday, 12 May 2005 Water cooled cables warm bus bars power converter.
BCWG - 16/11/20102 Content WHY do we need a HW Commissioning campaign? WHAT are we going to do? HOW are we going to do it? ElQA QPS Powering Tests Planning.
SAFETY DURING HARDWARE COMMISSIONING, 18 October 2007, D. Bozzini, AT/MEL-EM 1 Safety during Hardware Commissioning Davide Bozzini on behalf of the ELQA.
Electrical Safety, Subpart K
[R. Alemany] [CERN AB/OP] [Engineer In Charge of LHC] HWC Workshop ( ) Consolidation and major changes that have impact on the powering circuits.
1 J. Mourao (TE/MPE/CP) Enhanced DQHDS functionality  Status for 2011  Increase Magnet diagnostic capabilities  Our proposals.
MPE Workshop for LS1 / 22 & 23 Nov. 2012, G. D’Angelo TE/MPE-EE ELQA during LS1 train, Special measurements and NCs Magnet replacement: AIV Splices consolidations:
Review of Sector th of February Tunnel Access During Powering Tests Hugues Thiesen, AB-PO.
AT-MEL Group Meeting, CERN, 1211 Geneva 23 1 ElQA activities during hardware commissioning N. Catalan Lasheras.
Machine Protection Review, R. Denz, 11-APR Introduction to Magnet Powering and Protection R. Denz, AT-MEL-PM.
CERN Jan 2006 Specific safety Issues for 2006 compared to 2004 P. Cennini AB Safety Requirement in case the Installation activities are going on.
The definition of the Earth system or grounding: the electric connection between the work of intentionally electrical device or network devices on the.
Training LHC Powering - Markus Zerlauth Powering Interlocks Markus Zerlauth AB/CO/MI.
MPP Meeting 07/03/2007 MPP Main Ring Magnet Performance Panel Meeting Wednesday 7th March 2007 Agenda: 1)Matters arising 2)Recommendations for the case.
Closing session Issues and questions from the audience and some from me Rüdiger Schmidt.
CSCM (Thermal Amplifier) Sequence and detailed planning 07/10/2011 M.Solfaroli Thanks to: K.Brodzinski, G.D’Angelo, M.Koratzinos, M.Pojer, R.Schmidt, J.Steckert,
Mitsubishi I-MiEV Isolation Procedure.
Logo area HL LHC IT STRING M. Bajko CERN TE-TM and QXF Review.
Training LHC Powering – Blanca Perea Solano From Individual System Tests to Powering to Nominal Blanca Perea on behalf of Hardware Commissioning Coordination.
EDMS N° V.1 TE-EPC Activities during LS1 V. Montabonnet [TE-EPC]
Hardware Commissioning Review, R. Denz, 12-May Superconducting circuits: what remains to be done during hardware commissioning R. Denz AT-MEL-PM.
Mikhail Ovsienko TE-MPE-EE
Considerations from machine protection and the ELQA teams
PSB Lock Out Test, Follow-Up AP. Bernardes-/EN-STI, K
TE-MSC-SCD EYETS th September, 2017.
Powering LHC magnets version 30/3/2007.
Minimum Hardware Commissioning – Disclaimer
LHC Hardware Commissionning
RELIABILITY OF 600 A ENERGY EXTRACTION SYSTEMS
Keeping LHC cold during LS periods Preliminary proposal
Powering the LHC Magnets
MPE main activities planned for LS2
Powering from short circuit tests up to nominal
Re-Commissioning (IST) of Electrical Systems: QPS, EE & PIC
Agenda Contents Different types of documents
+ many slides from various colleagues (KH, Rudiger, Paul, …)
PSS0 Design & Concept of Operations
Hardware Commissioning
Circuit Disconnector Boxes Implementation of our safety first policy
Powering and Safety day Underground access during powering tests
Review of hardware commissioning
Presentation transcript:

1 Powering Tests and Safety Electrical Safety Hugues Thiesen Power Converter Group

2 Content Powering Tests & Safety, H. Thiesen, 23 July Electrical Safety 2.LHC Specificities 3.Electrical Safety Subsectors (ESSS) 4.Intervention Guideline 5.Remarks

3 Electrical safety Powering Tests & Safety, H. Thiesen, 23 July The Electrical Safety is put in place for YOUR SAFETY The electrical safety rules are not administrative rules When you do not respect the electrical safety you play with your safety 2.At CERN, the Electrical Safety is based on the UTE-C publication The UTE-C defines general rules to assure the electrical safety of the workers. The UTE-C must be adapted at the electrical installation Code C1 Hardware Commissioning Electrical Safety Procedures The UTE-C defines that the electrical workers MUST be “Habilité” (Trained). B0/H0 for the no electrical workers B1/H1 for the electrical workers B2/H2 for the persons in charge of the Electrical Safety.

4 Powering Tests & Safety, H. Thiesen, 23 July Electrical Safety Before to work on electrical installation, all electrical risks MUST be eliminated The elimination of the electrical risks is realized by the “consignation” of the installation Separate the installation from its electrical sources Lock in open position the separation devices Identify the installation Check that the voltage is zero and earth and short circuit the installation (“MALT-CC”). In the case of LHC: The two first steps are realized by the “chargé de consignation” (BC). The BC is a member of the equipment group For an installation, we can have several BCs The two last steps are realized by the “chargé de travaux” (B2) The B2 is a member of the team which realizes the intervention for the electrical interventions. The B2 is a member of the HCC team for the no electrical interventions. Electrical safety

5 Powering Tests & Safety, H. Thiesen, 23 July High energy stored in the superconducting magnets The “consignation” as defined in the UTE publication is not enough to assure the elimination the electrical risks. Before to work on an electrical superconducting circuit (see EDMS ) It is mandatory to verify the absence of current. The absence of current is realized before the “MALT-CC”. The absence of current is realized by the power converters group under the responsibility of the B2. The EE switch must be locked in open position. LHC Specificities (at cold)

6 Powering Tests & Safety, H. Thiesen, 23 July High energy stored in the QPHS The high current superconducting magnets are protected by QH supplied by QHPS (capacitor banks changed at 900V). The QHPS can generate an electrical risk if the insulation between the HQ and the magnet is broken. LHC Specificities (at cold)

7 Powering Tests & Safety, H. Thiesen, 23 July High energy stored in the QPHS Before the intervention: For the IPD, IPQ and IT magnets, the QHPS must be switched off and discharged. For the MB and MQ magnets, It is mandatory to ground the current leads if the intervention is done at the level of the DFBA It is mandatory to switch off and to discharge the concerned QPHS if the intervention is done at the level of the IFS boxes. LHC Specificities (at cold)

8 Powering Tests & Safety, H. Thiesen, 23 July Vicinity between superconducting circuits In the same cryostat, the superconducting circuits are close to each other To assure the electrical safety, Electrical Safety Subsectors (ESSS) have been defined (EDMS ): An Electrical Safety Subsector is a cryogenic section electrically isolated from the rest of the machine In some cases, two or three Electrical Safety Sub Sectors belong to the same Powering Subsector. LHC Specificities (at cold) PSS ESSS

9 Powering Tests & Safety, H. Thiesen, 23 July Vicinity between superconducting circuits The list of the ESSS is accessible from the HCC web site LHC Specificities (at cold)

10 Powering Tests & Safety, H. Thiesen, 23 July Intervention on an ESSS (except the ARC). All the superconducting circuits must be “consignés” PCs must be separated from the electrical network and their feeders must be locked in open position. Absence of current must be verified Absence of voltage must be verified Current Leads must be grounded DC cables must be grounded if necessary All the EE systems must be locked in open position. QHPSs must be separated from the electrical network and must be discharged. Their feeders must be locked in open position. LHC Specificities (at cold)

11 Powering Tests & Safety, H. Thiesen, 23 July Intervention on an ARC At the DFB module level (Low Current Module or High Current Module) All the superconducting circuits of the DFB module must be “consignés” All the EE systems of the DFB module must be locked in open position. All the QHPS of the DFB module and located in the UA and the RR must be separated from the electrical network and discharged. Their feeders must be locked in open position. At the level of the IFS boxes All concerned superconducting circuits must be “consignés” All concerned EE systems must be locked in open position All concerned QPHS must be separated from the electrical network and discharged. Their feeders must be locked in open position No powering tests on the ARC during the intervention LHC Specificities (at cold)

12 Powering Tests & Safety, H. Thiesen, 23 July Before the intervention The intervention must be planned with HCC (Point Owner and EIC) What, when, where, etc… ADI The risks must be correctly identified Electrical risks and the others (cryo, mechanical, etc…) VIC Equipment specialists, Point Owner, safety experts, etc… The “consignation” must be realized Electrical, cryo and others “consignation” The HCC “chargé de travaux” (Gérard Pastor) must be contacted for no electrical intervention on or close superconducting circuits. The “chargé de travaux” gives an “Autorisation de travail” The “chargé de consignation” must be contacted for electrical intervention on or close superconducting circuits. Intervention Guideline

13 Powering Tests & Safety, H. Thiesen, 23 July During the intervention Inform the CCC that the intervention is started. The electrical safety rules must be respected. Respect the fencing and the panels Do not realize an other intervention 3.After the intervention Inform the CCC that the intervention is finished. Realized the “déconsignations” and give to the HCC “chargé de travaux” the “Autorisation de travail” Intervention Guideline

14 Powering Tests & Safety, H. Thiesen, 23 July The UTE publication and the HCC electrical safety procedures give only general rules. We can not write a procedure for each intervention. The intervention must be realized by trained technicians 2.The main actor of your safety is you Follow the procedures Respect the fencing and the panels 3.Do not believe, be sure. Have always the “yellow paper” before to start the intervention. 4.The safety is a dynamic process 5.In the tunnel, there are less and less fencing and panel Remarks