1 Distributed Generation and Power Quality. 2 Distributed Generation Distributed generation (DG) or distributed generation resources (DR) –Backup generation.

Slides:



Advertisements
Similar presentations
Methane Capture and Use: Current Practices vs. Future Possibilities.
Advertisements

New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Wind Turbine Session 4.
Wind Turbine Generators
1 Distributed Generation and Power Quality. 2 Relaying considerations DG infeed may reduce the reach of overcurrent relays –DG feeds fault, so utility.
AES Buffalo Gap Wind Farm Buffalo Gap MW 155 – GE 1.5 sle Presented August 22, 2008 By Robert Sims AES Wind Generation.
Campus da FEUP Rua Dr. Roberto Frias, Porto Portugal T F © 2009 Decentralised Energy Systems.
1 Smart Distribution Systems: Sustainability Issues S. S. (Mani) Venkata Alstom Grid and University of Washington (UW)
Interconnection of Distributed Generation
PARMENANT MAGNET SYNCHRONOUS GENERATOR BY JA’FAR R.A. AZIM Assem M.A. Al ighrair.
Three-Phase ac Voltage Generation
LECTURE 9 INTRO TO POWER ELECTRONICS
Hybrid Power Systems. INTRODUCTION In the last lecture, we studied –Principles of generation of electricity –Faraday’s law –Single phase and 3 phase generators.
Importance of advanced simulations of electrical system in wind turbines April 2010.
Tennesse Technological University
AC MOTOR INDUCTION MOTOR.
Interconnect Protection of Dispersed Generators
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
PRESENTATION ON INDUCTION MOTOR
HomeNextPrevious I. INTRODUCTION II. WIND TURBINE GENERATOR MODEL III. STATCOM MODEL IV. SIMULATION RESULT CONTENTS OF TOPIC V. CONCLUSION Previous HomeNextHomePreviousNextHome.
Overcurrent Protection and Voltage Sag Coordination in Systems with Distributed Generation J. Carlos Gomez 1 M. M. Morcos 2 1 Rio Cuarto National University,
1 HARMONIC ANALYSIS OF SELECTED DG DEVICES Pradipta Kumar Tripathy, Durgesh P. Manjure, Dr. Elham B. Makram CLEMSON UNIVERSITY ELECTRIC POWER RESEARCH.
Synchronous Induction
Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Controllability of DG helps managing Distribution Grids J. A. Peças Lopes
Introduction to Electricity PART 1
AC Generators (Alternators)
ECE 576 – Power System Dynamics and Stability Prof. Tom Overbye University of Illinois at Urbana-Champaign 1 Lecture 23: Renewable.
1 TRANSMISSION SYSTEM OVERVIEW NETWORK OPERATING COMMITTEE April 17, 2007 New Mexico Transmission System Overview.
CLEMSON UNIVERSITY DG CONFERENCE UPDATE ON THE CURRENT STATUS OF DG INTERCONNECTION PROTECTION WHAT IEEE 1547 DOESN’T TELL YOU ABOUT INTERCONNECTION PROTECTION.
Power Generation from Renewable Energy Sources Fall 2012 Instructor: Xiaodong Chu : Office Tel.:
Power System Fundamentals EE 317 Lecture 9 27 October 2010.
AES Buffalo Gap Wind Farm Buffalo Gap MW 155 – GE 1.5 sle Presented August 22, 2008 By Robert Sims AES Wind Generation.
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
MODELING AND SIMULATION OF WIND TURBINE –DOUBLY FED INDUCTION GENERATOR (WT-DFIG) IN WIND FARM USE MATLAB/SIMPOWERSYSTEM Student : TRUONG XUAN LOC.
Chapter 5. Synchronous Machines.
Power Quality Impacts of Distributed Generation Roger C. Dugan Sr. Consultant Electrotek Concepts, Inc. Tennessee Tech. February 9, 2004.
Electric Machine Introduction
Wind Energy. How does wind energy work? The wind blows on the blades and makes them turn. The blades turns a shaft inside the nacelle (the box at the.
Introduction to Power Supplies
Grid connection of distributed generation
1 Distributed Generation and Power Quality-Continued.
Steady State Analysis Of A Microgrid Connected To A Power System
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
ELECTRIC DRIVES INTRODUCTION TO ELECTRIC DRIVES. Electrical Drives Drives are systems employed for motion control Require prime movers Drives that employ.
By Kasey Poirier, Eean Albro, Chase Lee
Lecture 32Electro Mechanical System1 Assignment 10 Page 396 Problems 17-9, 17-14, and Due Date: Thursday 28 th April, 2011 Quiz No.5 Next Week Quiz.
POWER ELECTRONICS IN SHIP PROPULSION ELECTRIC MOTORS.
BLDC Motor Speed Control with RPM Display. Introduction BLDC Motor Speed Control with RPM Display  The main objective of this.
Overview OF MULTI Mega Watt WIND TURBINES and wind parks
 Definition  Centralized System  Fuel cells  Photovoltaic  Wind Turbines  Islanding  Advantages  Disadvantages.
Synchronous Motors Introduction An alternator may operate as a motor by connecting its armature winding to a 3-phase supply. It is then called a synchronous.
INDUCTION GENERATOR FOR WIND POWER GENERATION
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
Components Motors and Generators.
Components Motors and Generators.
Power Electronics and Control in Wind Energy Conversion Systems
Electric Motors and Generators
Distributed Generation
Speed control of three phase induction motor
Induction Motor as a Induction Genrator
IG BASED WINDFARMS USING STATCOM
Control Schemes for Distribution Grids with Mass Distributed Generation AUTHOR: UMAIR SHAHZAD.
Lesson 16: Asynchronous Generators/Induction Generators
Electric Machine Introduction
Wind turbine technology
ECE 333 Green Electric Energy
Electrical Machines-II
Principle of Operation
Presentation transcript:

1 Distributed Generation and Power Quality

2 Distributed Generation Distributed generation (DG) or distributed generation resources (DR) –Backup generation to improve reliability –Economics and/or diversity of fuel sources –Perhaps can relieve T&D system overloads in short term, especially if load growth is uncertain - Effect the power quality

3 Interconnection Large units 10 MW and up –set up as a small power plant connected to transmission network –may be steam cycle or combined cycle –may include co-generation Medium units 1-10 MW –may connect to distribution or subtransmission line –may be combustion turbine

4 Interconnection (cont’d) Small units (below 1 MW) –connect to distribution –may be reciprocating engine (diesel or natural gas) or microturbine Unconventional generation includes fuel cells, solar photovoltaic, wind turbines –need to be considered separately

5 Fuel Cells Electrochemical cells (not a heat engine) –Net reaction: 2H 2 + O 2  2H 2 O –PEM (proton exchange membrane) cell: A K A = anode (negative) K = cathode (positive) PEM = proton exchange membrane H2H2 O2O2 2H 2 O 4e -

6 Fuel Cells –Net reaction: 2H 2 + O 2  2H 2 O –PEM (proton exchange membrane) cell –Anode: 2H 2  4H + +4e - –Cathode: O 2 + 4H + + 4e -  2H 2 O A K H2H2 O2O2 2H 2 O 4e - 4H + Catalyst 4e - I 0.7 V

7 Fuel cells –Diagrams are oversimplified to illustrate the basic idea –In practice, stacks of cells must be used for power level generation –Stacks produce DC which is fed to a power electronic inverter V dc a b c

8 a b c IGBT or power transistor, e.g. Flyback or free-wheel diode Passive filter

9 Photovoltaic –Stacks of solar photovoltaic cells produce DC which is fed to a power electronic inverter, just as with fuel cells. V dc a b c –Issue is high installed cost, but breakthrough may be possible

10 Wind turbines Each turbine may be ~ 1 MW with multiple turbines in a “wind farm” Small farm ~ 5 MW connected to distribution or subtransmission Large farm ~100 MW connected to transmission Issues are voltage regulation and power fluctuations

Basic Components of Wind Energy Systems 1)Turbine blades 2) Turbine hub 3) Shaft 4) Gear box 5) Generator 6) Nacelle 7) Transformer 8) Control 9) Tower 10) Foundation # Drive train, usually includes a gearbox and a generator

Major Turbine Components Figure. Major turbine components.

Relationship of Wind Speed to Power Production # Power production from a wind turbine is a function of wind speed. # In general, most wind turbines begin to produce power at wind speeds of about 4 m/s (9 mph), achieve rated power at approximately 15 m/s (29 mph), and stop power production at 25 m/s (56mph). # Cut-in wind speed: The speed at which the turbine starts power production. # Cut-out wind speed: The speed at which the turbine stops power production.

Pitch Control Method  1+T d S PI controller ω r + - ω IGref 1 TiSTiS K p (1+ ) K p =252 T i =  /S Rate limiter Figure. Pitch control system model. # Usually the main purpose of using a pitch controller with wind turbine is to maintain a constant output power at the terminal of the generator when the wind speed is over the rated speed.

15 Machine Type Synchronous machine can easily sustain an “inadvertent island” wherein it attempts to supply nearby loads Induction generator can also, but is somewhat less likely (unless capacitors in the island temporily supply reactive power, the voltage will tend to collapse)

16 Mechanically driven generators Synchronous generator directly connected to power system (similar to central station generation) Induction or asynchronous generator directly connected to power system –Induction machine driven faster than synchronous speed will generate real power but still absorb reactive power from electrical system –Doubly-fed induction generator:

17 Wind generators Conventional generators are almost all synchronous machines with a wound field Wind generators may be induction generators –conventional: fed only from stator so always draws reactive power from electrical system –doubly fed: feed rotor winding from a power electronic converter to achieve some var control

Figure. Fixed speed wind turbine generator (squirrel cage induction generator).

19 Wind generator interface Power electronic converter can be used as an interface between either induction or synchronous generator Converter controls may provide significant help with managing voltage fluctuations

Figure. Variable-speed wind turbine with doubly fed induction generator (DFIG). Figure. Variable-speed wind turbine with squirrel cage induction generator.

21 –On a weak system, voltage fluctuations are difficult to manage –Power fluctuations will “drag” nearby generators on regulation and tie lines (forcing other generators to make up for the fluctuations WF Tie Steam Hydro Loads

22 –The steam turbines may be base loaded, so the hydro and the tie line will make up for both load fluctuations and the wind-farm generation fluctuations –Net effect is that wind is good energy source but not as good for firm power production WF Tie Steam Hydro Loads

23 Trip DG Fault Neighboring loads Inadvertent Island: DG attempts to energize the island, feeding fault, complicating protective relay coordination

24 PQ issues affected by DG Sustained interruptions –DG can provide backup power for critical loads by operating stand-alone during outage and (perhaps) in parallel during normal conditions –Voltage regulation limits how much DG a distribution feeder can handle –Harmonics are a concern with synch generators and inverters (less so with modern inverters) –Voltage sags: DG helps some but not all cases

kV kV TRANSMISSION DISTRIBUTION Radial Line DG DG on radial distribution line needs to disconnect early in reclosing interval

26 Relaying considerations Reclosing on a synchronous machine (motor or generator) directly connected to power system can mechanically damage the unit (e.g., shaft is stressed -> cracks) DG infeed may reduce the reach of overcurrent relays –DG feeds fault, so utility current is fault current minus DG contribution

I ut X ut X1X1 X dg X2X2 3  SC I dg =0 IfIf VxVx No DG:

I ut X ut X1X1 X dg X2X2 3  SC I dg IFIF VxVx With DG, utility sees less current:

kV kV Put recloser here DISTRIBUTION Radial Line DG Only one DG: obvious solution to several problems

kV kV DG “Sympathetic” tripping of this circuit breaker (not desired) due to backfeed from DG Fault Solution is to use directional overcurrent relays at substation (need voltage polarization for phase angle reference, which is extra expense)