PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Future directions and current challenges of.

Slides:



Advertisements
Similar presentations
Dept of Radiation Oncology MGH
Advertisements

Harvard Medical School Massachusetts General Hospital.
HST.187: Physics of Radiation Oncology #9. Radiation therapy: optimization in the presence of uncertainty Alexei Trofimov, PhD Jan.
Managing uncertainty using robust optimization Timothy Chan University of Toronto BIRS radiation therapy workshop March 12, 2011.
The Tomotherapy Experience at Advocate Good Samaritan Hospital
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Experience, Expertise and a Commitment to Excellence™
Anatomy-based MLC Field Optimization for the Treatment of Gynecologic Malignancies Myriam Bouchard M.D. Nadeau S, Germain I, Raymond P.E., Harel F, Beaulieu.
Algorithms used in heterogeneous dose calculations show systematic error as measured with the Radiological Physics Center’s anthropomorphic thorax phantom.
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
Conformal Radiotherapy for Head and Neck Cancer Conformal Radiotherapy in Head and Neck Cancer B. Schicker, U. Götz, I. C. Kiricuta ISRO-Limburg - Germany.
Para-spinal Tumors Encircling the Spinal Cord IMRT Comparison of Several Target Definitions.
Targeting Issues For Proton Treatments Of The Prostate SJ Rosenthal Ph.D., JA Wolfgang Ph.D., Sashi Kollipara Department of Radiation Oncology Massachusetts.
Real-time tumor tracking with preprogrammed dynamic MLC motion and adaptive dose-rate regulation B.Y Yi, S. Han-Oh, F. Lerma, B. Berman, C. Yu.
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
Interactions of charged particles with the patient I.The depth-dose distribution - How the Bragg Peak comes about - (Thomas Bortfeld) II.The lateral dose.
tomos = slice, graphein = to write
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
Radiotherapy Planning for Esophageal Cancers Parag Sanghvi, MD, MSPH 9/12/07 Esophageal Cancer Tumor Board Part 1.
Radiotherapy for Kidney cancer
بسم الله الرحمن الرحيم و قل رب زدنى علماً ﴿و قل رب زدنى علماً﴾ صدق الله العظيم.
به نام خداوند بخشایندۀ بخشایشگر
Conformal Therapy for Lung Cancer B. Schicker, F.J. Schwab*, U. Götz Institute of Radiotherapy and Radiation Oncology St. Vincenz-Krankenhaus Limburg *Clinic.
The Skandion clinic, plans for the use of particle beams for radiation therapy in Sweden presented by Erik Grusell, medical radiation physicist Dept of.
The external beam radiotherapy and Image-guided radiotherapy (2)
Comparison of Rectal Dose Volume Histograms for Definitive Prostate Radiotherapy Among Stereotactic Radiotherapy, IMRT, and 3D-CRT Techniques Author(s):
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
Clinical aspects of carbon ion RT Daniela Schulz-Ertner.
Medical requirements for FFAG as proton beam sources Jacques BALOSSO, MD, PhD Radiation oncologiste UJF / INSERM / ETOILE FFAG 2007, April 12-17, 2007.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Region of Interest Analysis as a Tool for Exploring Adaptive IMRT Strategy for Cervix Cancer Patients Young-Bin Cho 1,2, Valerie Kelly 1, Karen Lim 1,2,
Clinical decisions in the optimization process I. Emphasis on tumor control issues Avi Eisbruch University of Michigan.
RESULTS 4D-Computed Tomography Guided Treatment Planning for Intrahepatic Tumors Yen-Lin Chen, M.D. 1,2, Eike Rietzel, Ph.D. 1,2, Judith Adams 1,2, John.
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
Physics of carbon ions and principles of beam scanning G. Kraft Biophysik, GSI, Darmstadt, Germany PTCOG43 Educational Satellite Meeting: Principles of.
Assessment of radiotherapy set-up error for limb sarcoma using electronic portal imaging (EPI) Wendy Ella, Eleanor Gill, Anna Cassoni, Beatrice Seddon.
Interaction of x-ray photons (and gamma ray photons) with matter.
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
Saad El Din I, M.D *, Abd El AAl H, M.D *, Makaar W, M.D *, El Beih D, M.Sc †, Hashem W, M.Sc * *Department of Clinical Oncology and Radiotherapy, Kasr.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
第三讲: Basic treatment planning - Dengsong Zhu, MS, DABR Medical Physicist Radiation Safety Officer.
Varian Medical Systems
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
beam delivery with SC magnets
Clinical benefits: fixed beam line vs gantry? PD Dr. Alexandra Jensen, MSc mingham-Why-send-tourists-there.html.
Beam specific PTV incorporating 4DCT for PBS proton therapy of thoracic tumors Minglei Kang, PhD Authors: Liyong Lin1*, Minglei Kang1*, Sheng Huang1,
Martin J Murphy PhD Department of Radiation Oncology
Progress in the Application
EURADOS Working Group 9: Radiation Dosimetry in Radiotherapy
The use of 4DCT images to optimize the Internal Target Volume in Radiotherapy  Nikos Giakoumakis, Brian Winey, Joseph Killoran, Tania Lingos, Laurence.
Press release Release of ISOgray Proton Treatment Planning System
Image–Guided Radiation Therapy for Non–small Cell Lung Cancer
Leksell Gamma Knife® Icon™
A Design of a Gantry with Superconducting Magnets for 350 MeV Protons
M. D. Anderson Cancer Center Houston, TX
Karla Leach, BS, CMD Texas Center for Proton Therapy-Irving, TX
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Fig. 4. Percentage of passing rate between clinical and 544 plans.
Reducing Treatment Time and MUs by using Dynamic Conformal Arc Therapy for SBRT Breath-Hold Patients Timothy Miller, Sebastian Nunez Albermann, Besil Raju,
Insert tables Insert figure
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Insert tables Insert graphs Insert figure
Radiation Oncology Department, Bank of Cyprus Oncology Center.
L. A. den Otter. , R. M. Anakotta. , M. Dieters. , C. T. Muijs. , S
A Multi-Institutional Dosimetric Evaluation of Proton Versus Photon Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma F. Khan, B. Nguyen,
Image–Guided Radiation Therapy for Non–small Cell Lung Cancer
Technical Advances of Radiation Therapy for Thymic Malignancies
Angjelina Protik, Marcel van Herk, Marnix Witte, Jan-Jakob Sonke 
Planning techniques of proton boost
Presentation transcript:

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Future directions and current challenges of proton therapy Tony Lomax, Centre for Proton Radiotherapy, Paul Scherrer Institute, Switzerland CT after 5 weeks Planning CT

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Overview of presentation 1.State-of-the-art proton delivery 2.Current challenges 3.New directions in proton therapy 4.Summary

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 State-of-the-art proton delivery Passive scattering Range-shifter wheel Collimator Compensator Target Patient Scatterer

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Spot scanning Pedroni et al, Med Phys. 22:37-53, 1995 Target Magnetic scanner ‘Range shifter’ plate Patient Proton pencil beam State-of-the-art proton delivery

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 The present and future of proton therapy? Passive scattering (patched fields) Collimators and compensators required for each field Intensity Modulated Proton Therapy (IMPT) Fully automated delivery (scanning) State-of-the-art proton delivery

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Sarcoma – 12 year old boy Delivered single field plan 9 field IMRT plan Factor 6 lower integral dose for protons State-of-the-art proton delivery

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Integral dose and secondary cancer risk State-of-the-art proton delivery K Haeller, PSI N Tarbell, ASTRO, 2008 Study comparing 503 proton patients to 1591 photon patients (treated ) showed a 50% reduction in secondary tumours in proton patients

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Overview of presentation 1.State-of-the-art proton delivery 2.Current challenges 3.New directions in proton therapy 4.Summary

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 The advantage of protons is that they stop. Range uncertainty The disadvantage of protons is that we don’t always know where… 10% range error Current challenges: range uncertainty

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 S. Mori, G. Chen, MGH, Boston Current challenges: range uncertainty Tumour shrinkage Initial Planning CT GTV 115 cc 5 weeks later GTV 39 cc

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Planning CT CT after 5 weeks Beam stops at distal edge Beam overshoot S. Mori, G. Chen, MGH, Boston Tumour shrinkage Current challenges: range uncertainty

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Patient weight changes 3 field IMPT plan to an 8 year old boy Note, sparing of spinal cord in middle of PTV Planning CT New CT During treatment, 1.5kg weight gain was observed Max range differences: SC 0.8cm CTV 1.5cm Francesca Albertini and Alessandra Bolsi (PSI) Current challenges: range uncertainty

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Current challenges: range uncertainty CT artefacts Many patients referred for RT post-operatively and with metal (titanium) stabilisation How accurately can we calculate proton ranges in such CT data sets?

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Months Without implant (n = 13) Implants (n =13) 3-yr, 5-yr 100% 3-yr 69% 5-yr 46% Chordomas and chondrosarcomas of the spinal axis Rutz et al 2007, IJROBP, 67, Current challenges: range uncertainty

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Martin von Siebenthal, Phillipe Cattin, Gabor Szekely, Tony Lomax, ETH, Zurich and PSI, Villigen What is the effect of organ motion on proton therapy? 4D-CT derived from 4D-MRI Current challenges: organ motion Organ motion

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Organ motion and passive scattering Current challenges: organ motion Images courtesy of Thomas Bortfeld, MGH, Boston Parallel opposed photons Single field photons Single field protons

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Organ motion and passive scattering Current challenges: organ motion Images courtesy of Thomas Bortfeld, MGH, Boston Parallel opposed photons Single field photons Single field protons

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Martin von Siebenthal, Phillipe Cattin, Gabor Szekely, Tony Lomax, ETH, Zurich and PSI, Villigen A scanned beam in a moving patient. 4D-CT derived from 4D-MRI Current challenges: organ motion Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Nominal (static) dose Calculated with ‘real’ motion from 4D-MRI of volunteer Organ motion and the ‘interplay’ effect Current challenges: organ motion

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Dose (%) Volume (%) Dose (%) Volume (%) Motion patient 1 Amplitude ~ 11mm Motion patient 2 Amplitude ~ 8mm Organ motion and the ‘interplay’ effect Current challenges: organ motion Scanning is particularly sensitive to organ motion

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Adenoid cystic carcinoma with node involvement Current challenges: treatment gantries Tricky to do without a gantry…

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Current challenges: treatment gantries Avoiding density heterogeneities Heterogeneity index Each point is a different field calculated for the same skull base case A comparison of MC and analytical dose calculations as a function of density heterogeneities

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Field Applied plan‘Standard’ plan Gantry angle Table angle Density heterogeneit y index Gantry angle Table angle Density heterogeneit y index Avoiding density heterogeneities Current challenges: treatment gantries

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Current challenges: treatment gantries 3.5m diameter PSI gantry 1 7m diameter PSI gantry 2 12m diameter Loma Linda 15m diameter Heidelberg Could this be the main limit to the spread of particle therapy?

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Overview of presentation 1.State-of-the-art proton delivery 2.Current challenges 3.New directions in proton therapy 4.Summary

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 New directions in proton therapy 1.Possible improvements to passive scattering 2.Dealing with range uncertainties 3.Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 New directions in proton therapy 1.Dealing with range uncertainties 2.Organ motion and scanning 3.Gantry design

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Imaging for range Ospedale San Rafaele, Milan Francesca Albertini, PSI kV-CT MV-CT (Hi-Art) MV-CT Proton radiograph Proton DRR Proton radiography Uwe Schneider, Zurich Alexander Tourovsky, PSI Measured PET activation Calculated PET activation Activation PET Katia Parodi, Thomas Bortfeld MGH, Boston Dealing with range uncertainties

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Robust planning techniques Tumour Spinal cord Lomax et al.:Med. Phys. 28(3): , 2001 Example paraspinal case Nominal plan 10% overshoot Dealing with range uncertainties

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, patched, intensity modulated fields give a homogenous dose without the use of fields that abut distally against the spinal cord Robust planning techniques Lomax et al.:Med. Phys. 28(3): , 2001 Dealing with range uncertainties

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, % overshoot plans IMPT Single field IMPT Nominal plans Single field IMPT plan Nominal Overshoot Nominal Overshoot Relative dose Relative volume D tol DVH analysis Spinal cord Robust planning techniques Dealing with range uncertainties

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Range adapted proton therapy Dealing with range uncertainties Alessandra Bolsi, PSI

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Work of Alessandra Bolsi. Dealing with range uncertainties Alessandra Bolsi, PSI Range adapted proton therapy

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Alessandra Bolsi, PSI Dealing with range uncertainties Range adapted proton therapy

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Dealing with range uncertainties Alessandra Bolsi, PSI Range adapted proton therapy

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 New directions in proton therapy 1.Dealing with range uncertainties 2.Organ motion and scanning 3.Gantry design

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Repaint scanned beam many times such that statistics dictate coverage and homogeneity of dose in target (c.f. fractionation) Organ motion and scanning Rescanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Rescanning 4s period Re-scanning in presence of Cos 4 motion with 1cm amplitude Cylindrical target volume Re-scanned different times to same total dose Scan times calculated for realistic beam intensities and dead times between spots Analysis carried out for different periods of motion Marco Schwarz, Silvan Zenklusen ATREP and PSI Not always improving homogeneity with number of re-scans! Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Rescanning The ‘synchronicity’ effect Very preliminary results A ‘real’ effect for perfectly regular breathing? Could well be less of an issue when breathing is more irregular For regular breathing, could be avoided by selecting the re- scanning period to avoid effect or varying period scan-to-scan Probably not a big issue in reality See presentation from Silvan Zenklusen, Saturday Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Track motion of tumour using scanning system based on some anatomical/physiological signal Tracking Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Steven van de Water, PSI/TUDelft Tumour Tracking Plot of dose homogeneity as function of RMS position error due to motion and ‘imperfect’ tracking Cos 4 motion with varying detection delays and tracking accuracies ~ 150ms delay Vedam et al 2004 Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Steven van de Water, PSI/TUDelft Tumour Tracking Re-tracking – tracking the tumour repeatedly within one fraction E.g. 4 times ~ 150ms delay Vedam et al 2004 Organ motion and scanning

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 New directions in proton therapy 1.Dealing with range uncertainties 2.Organ motion and scanning 3.Gantry design

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Still rivers systems single room proton facility Gantry design DWA based proton tomotherapy Probably the biggest step forward for particle therapy would come from a significant reduction in gantry size To stay competitive with other therapies for the next 25 years, treatment gantries will almost certainly be necessary

PAUL SCHERRER INSTITUT Future directions and current challenges of proton therapy Tony Lomax, Oxford, 2008 Summary Although passive scattering is still the preferred choice for proton therapy, scanning and IMPT will become more widespread in the next years (c.f. MD Anderson) To what extent can scattering be improved through the use of automated field hardware (MLC’s etc)? Range uncertainty and organ motion (particularly for scanning) remain the main challenges to proton therapy and much interesting and exciting work is still to be done in organ management, range imaging and adaptive proton therapy The field is ripe for new input, ideas and innovations…