MTE´s Portable Product Portfolio

Slides:



Advertisements
Similar presentations
PV String Monitoring Solution
Advertisements

High Voltage Supply. High voltage Supplies Generators should provide a smooth constant high voltage to the X-ray tube.

Multi Functional Digital Fault Recorder
By- EMBUILT TECHNOLOGIES (THD MEASUREMENT WITH EXAMPLES AND FIGURES) Date-03/09/2014.
TRANSFORMERS. TRANSFORMER PARAMETERS Turns Ratio (n) It is defined as the ratio of the number of turns in the secondary winding (N sec ) to the number.
Problem #2-8 A 480 – 120 V, 60 Hz transformer has its high voltage winding connected to a 460 V system, and its low voltage winding connected to a 24/32.8°Ω.
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
SUBJECT : DC Machine & Transformer
Introduction to Op Amps
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
POWER SUPPILES LECTURE 20.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
A Company Selling Technology and not just a Product.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
Transformer with open secondary.
CALPORT 300 Three-Phase Portable Reference Standard
Metra Mess- und Frequenztechnik Radebeul / Germany Piezoelectric Accelerometers Theory & Application.
/1 Testing Harmonics and Flicker /1 Harmonics & Flicker Two different test standards: EN & EN EN controls.
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
PPS 3.3 C Portable Power Source Page 1 January 2011.
Portable Working Standard and Power Quality Analyzer
SFT 2841 IN CONNECTED MODE Prepare setting files.
AUTOMATIC VOLTAGE REGULATOR(AVR)
Radian Research, Inc. Radian Research, Inc. an employee owned company Power and Energy Measurement Specialists 3852 Fortune Drive.
CPT2000 Platinum Resistance CED7000 & others Signal calibrators CPT9000 Thermocouple CPT1000 Platinum Resistance Features & Benefits Reference Thermometers.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
POWER CIRCUIT & ELECTROMAGNETICS
Power Probe The PSP Power Probe is a three phase data logger, quality of supply monitor, and remote terminal unit for demand-side- management. Historical.
8114A Overview. 8114A Overview 10-Feb-04 Page A Overview 1) Specifications and Applications 2) Operational Overview 3) Block Diagram.
PTS 2.3 C Portable Test System Page 1 March 2009.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Measurements & instrumentation. Aim: To provide adequate knowledge in electrical instruments and measurements techniques. Objectives: To make the student.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Regulated Power Supplies
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh 1, In Ho Ryu 2 and Jeong-Chay Jeon 3 * 1 Department.
Electrical Engineering
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
©2012 QuEST Global Services Pte Ltd. The information in this document is the property of QuEST Global Services Pte Ltd. and may not be copied or communicated.
1 Eeng 224 Chapter 13 Transformer Applications Huseyin Bilgekul Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern Mediterranean.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Measurement and Instrumentation
D.C. Machine & Transformer Topic: Instrument Transformer Electrical:-1 presented by: Jill Chauhan ( ) Chirag Agarawal ( )
EEK260 -Electrical Machines By Dr. Mohamad Kamarol Mohd Jamil Room: 2.32 Ext: 6064.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
DIGITAL MULTIMETER DMG
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Sensor presentation.
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
Portable Working Standard
25-year Experience in Power Industry
ProtoDUNE SP – Slow control temperature readout setup test
PTS 3.3 C Portable Test System.
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
HD POWER TRANSDUCER SERIES
Sensor presentation.
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh1, In Ho Ryu2 and Jeong-Chay Jeon3* 1Department.
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Lesson 11: Transformer Name Plate Data and Connections
HD SIGNAL CONDITIONER SERIES
PowerLogic™ offer for the basic metering market
Presentation transcript:

MTE´s Portable Product Portfolio Page 1 April 2011

MTE Portables

K 2006 3-phase Comparator 30 V … 500 V 1 mA … 160 A Accuracy  0.01% 15 Hz - 70 Hz Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement and harmonic analysis DC reference voltage input Options: CAMCAL® Software CALSOFT Software

PRS 400.3 3-phase portable Reference Standard 0 V … 520 V (phase-neutral) 1 mA … 120 A direct connections Clamp-on CTs: 100A  1.000A  FLEX 3000 up to 3.000A / Hot sticks for measurement on high voltage potential Vector diagram, harmonics spectrum, wave form and rotary field display Burden measurement and ratio tests of CT’s and PT’s Transducer test Accuracy  0.02 %

CALPORT 300 3-phase Meter and Instrument Transformer Test System 40 mV … 480 V 1 mA … 120 A Accuracy  0.05 % 6 current inputs parallel for primary / secondary current measurement Measurements of all electrical parameters (incl. vector diagram) CT / PT testing (burden, ratio) Options: CALSOFT Software Clamp-on CTs for 100A  1000A  FLEX 3000 up to 3000A  LiteWire Sensors up to 2000 A and 40 kV

PWS 3.3 3-phase Portable Working Standard and PQ Analyzer Working Standard Functions 20 mV … 600 V (phase-neutral) 1 mA … 12 A direct connection Measurements of all electrical parameters (incl. vector diagram) CT / PT testing (burden, ratio) Accuracy  0.1 %,  0.05 % PQ Analysis Functions Harmonics  Interharmonics  Signal voltages  Dips  Swells  Interruptions  Voltage unbalance Options: Clamp-on CTs for 100A  1000A  FLEX 3000 up to 3000A  LiteWire Sensors up to 2000 A and 40 kV

PWS 2.3 PLUS 3-phase Working Standard 20 mV … 300 V (phase-neutral) 1 mA … 12 A direct connection 10 mA … 100 A via clamp-on CTs Measurements of all electrical parameters (incl. vector diagram) CT / PT testing (burden, ratio) Accuracy  0.1 %,  0.2 % Options: CALSOFT I Software Clamp-on CTs for 1000A  FLEX 3000 up to 3000A  LiteWire Sensors up to 2000 A and 40 kV

CheckMeter 2.3 3-phase Working Standard 10 V … 300 V Auxiliary supply from the auxiliary supply or the measuring circuit 10 mA ... 100 A via clamp-on CTs Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement, vector diagram Accuracy  0.2 % Options: CALSOFT I Software Clamp-on CTs up to 120 A (Measuring range 100 mA … 120 A, Cable : max 52 mm)

CheckMeter 2.1 3-phase Working Standard 10 V ... 300 V Auxiliary supply from the auxiliary supply or the measuring circuit 10 mA ... 100 A via clamp-on CT Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement Accuracy  0.2 % Options: CALSOFT I Software Clamp-on CTs up to 120 A (Measuring range 100 mA …120 A, Cable : max 52 mm)

MTE Portables

PPS 400.3-12 A 3-phase portable Voltage and Current Source 0 V ... 300 V / 50 VA / Phase 1 mA ... 12 A / 30 VA / Phase Phase shifter -180° ... 0 ... +180° 45 ... 400 Hz Stability  0.005 %/h ( = 150 s) Generation of harmonics up to 31st Ripple control signals Options: CALSOFT II CAMCAL for Windows

PPS 400.3-120 A 3-phase portable Voltage and Current Source 0 V ... 300 V / 50 VA / Phase 1 mA ... 120 A / 80 VA / Phase Phase shifter -180° ... 0 ... +180° 45 ... 400 Hz Stability  0.005 %/h ( = 150 s) Generation of harmonics up to 31st Ripple control signals Options: CALSOFT II CAMCAL for Windows

PPS 3.3 C 3-phase portable Voltage and Current Source 0 V ... 480 V / 30 VA / Phase 1 mA ... 120 A / 60 VA / Phase Phase shifter -180° ... 0 ... +180° 45 ... 400 Hz Stability  0.03 %/h ( = 150 s) Generation of harmonics up to 31st Ripple control signals Options: CALSOFT II CAMCAL for Windows

CheckSource 2.3 3-phase electronic Current Source 1 mA ... 6 A / 8 VA / Phase Phase shifter -180° ... +180° Stability better than 0.03 % (30 min) 0.1 % (1 h) Single phase supply  50 VA (typical)  65 VA (maximum) Options: CALSOFT Software

MTE Portables

PTS 400.3 3-phase portable Test system with Voltage and Current Source Voltage source 0 ... 300 V Current source 1 mA ... 12 A / 120 A Reference standard accuracy class 0.02 % Measurement of all electrical values Vector diagram, harmonic test, Data storage, Ratio test, Burden test Automatic test runs without external PC Options: High current cables up to 120 A Several Clamp-on CT´s CALSOFT II Software CAMCAL for Windows

PTS 3.3 C 3-phase portable Test system with Voltage and Current Source Voltage source 30 ... 480 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.05 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage, Burden test Automatic test runs without external PC Options: High current cables up to 120 A Clamp-on CT´s 10 mA ... 100 A CALSOFT II Software

Checksystem 2.1 S 1-phase portable Test system with Current Source Measurement range 10 mV ... 480 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.05 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage Automatic test runs without external PC Options: Clamp-on CT 10 mA ... 100 A CALSOFT Software

PTS 3.1 C 1-phase portable Test system with Voltage and Current Source Voltage source 30 ... 480 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.1 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage, Burden test Automatic test runs without external PC Options: High current cables up to 120 A Clamp-on CT 10 mA ... 100 A CALSOFT II Software

PTS 2.3 C 3-phase portable Test system with Current Source Measurement range 20 mV ... 500 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.1 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage, Burden test, C.T. ratio test Automatic test runs without external PC Options: Clamp-on CTs for 100A  1000A  FLEX 3000 up to 3000A CALSOFT II Software

Checksystem 2.3 3-phase portable Test system with Current Source Measurement range 10 mV ... 300 V Current source 1 mA ... 16 A Integrated working standard accuracy class 0.2 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage Automatic test runs without external PC Options: Clamp-on CTs 10 mA ... 100 A CALSOFT Software

Checksystem 2.1 1-phase portable Test system with Current Source Measurement range 10 mV ... 300 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.2 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage Automatic test runs without external PC Options: Clamp-on CT 10 mA ... 100 A CALSOFT Software

CALSOFT Software tool to portable devices Automatic single position measurement Easy to understand presentation of all stored measured values Vector diagram Presentation of measured values Presentation of harmonics Print and data export functions Works together with following portables:  K2006  PRS 400.3 / CALPORT 300 / PWS 3.3 PWS 2.3 PLUS / CheckMeter 2.x  PTS 400.3 / PTS 3.3 C / PTS 3.1 C PTS 2.3 C / CheckSystem 2.x  PPS 400.3 / PPS 3.3 C / CheckSource 2.3