Bullard PA20 Powered Air Purifying Respirator (PAPR) Training Material

Slides:



Advertisements
Similar presentations
Standard 29 CFR Part Respiratory Protection.
Advertisements

Personal Protective Equipment (PPE)
SKA-Pak Plus Mobile Air Cart Con-Space Link
CBR Suit Training Disaster Preparedness and Management Unit.
Personal Protective Equipment (PPE)
RESPIRATORY PROTECTION …examination of the appropriate role of personal protection against inhalation hazards.
GPHL Respirator Training
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Respiratory Protection Program (RPP) San Joaquin Delta College Revised: 10/05/2011.
Powered Air Purifying Respirator (PAPR) Infection Control Unit.
PPE Use in Healthcare Settings: How to Safely Don, Use, and Remove PPE
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
Respiratory Protection
Use and Limitation of N-95 Filtering Facepiece Environment, Health and Safety Occupational Health and Hygiene 2009.
2 Fire Fighter Qualifications and Safety Skill Drills.
SFFMA Training Objectives: –
Radiation Protection Technology Respiratory Protection Air Sampling Radiological Safety and Response RPT-243-PE-6.
New SCBA Brackets Coming to a fire engine near you.
3M Occupational Health and Environmental Safety Division © 3M M Air-Mate™ High Efficiency Powered Air Purifying Respirator (PAPR)
Usage and Care Updated August Thank You for Choosing EVA.
Two-mode Safety and Battery System Service
Doffing PPE (with PAPR) 12/23/ Requires that the trained observer be donned in level 1 PPE *This associate will read aloud each step of the doffing.
Personal Protective Equipment Respirator Usage and Safety.
Providing services that help make The University of Memphis a safe and healthful place to learn and work Environmental Health and Safety.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
Clean Air Box Usage & Care CABs RAMs CO Monitors.
EVAHL The EVA PAPR for Hazardous Locations Updated February 12, 2013.
Copyright  Progressive Business Publications Blue Ridge Safety Association Safety Training Presentations Respirator Safety.
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
Respirator Fit Testing and Training. Definitions l High efficiency particulate air (HEPA) filter l Immediately dangerous to life of health (IDLH) l Negative.
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
General Industry Standards Personal Protective Equipment.
Rowan University. Definitions High efficiency particulate air (HEPA) filter Immediately dangerous to life of health (IDLH) Negative pressure respirator.
Respiratory Protection Program 29 CFR Respiratory Protection Program When respiratory protection is necessary When respiratory protection is.
Personal Protective Equipment
Presented By MassArt Environmental Health & Safety.
3M Occupational Health and Environmental Safety Division © 3M Air-Mate™ High Efficiency Powered Air Purifying Respirator (PAPR)
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
Respiratory Protection
1. 2 EVA Powered Air Purifying Respirator EVA is NIOSH Approved An EVA PAPR System consists of four components: ▪ Hood or Mask ▪ Breathing Tube ▪ Blower.
The Headphones1 Trainer Training The Headphones. 2 There are three sets of headphones There are three transmitters Transmitters also act as battery chargers.
Respiratory Safety Public Safety Murray State University.
Eye Health & Safety: Chemical Exposure in the Workplace.
ResponderTM CBRN PAPR.
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
NIEHS – HMTRI Katrina Response Initiative 10/17/20052 U45 ES Safety Awareness for responders to Hurricane Katrina Operations: Respiratory Protection.
Issue #1 - N95 respirator shortcomings Fitting testing takes time and is expensive Scheduling fit testing for an entire hospital staff is time consuming,
Pharmacia & Upjohn Inc.1 Respirator Fit Testing and Training.
1 Hazard Statement Domain Domain specialization of element.
Respirator Fit Testing and Training
PUBLIC SAFETY INSTRUCTIONS
National Fit Testing Services OSHA CFR Respiratory Protection Program Presented by National Fit Testing Services Linda Lane, RRT/President.
RESPIRATORY SAFETY. Respirators Will Protect You + Hazardous particles in the air can cause serious injuries or death + Use a respirator whenever you.
3M FR-57 Gas Filter Cartridge. Fr-57 Filter Cartridge One piece of the PAPR (powered air purifying respirator) system Only compatible with 3M Breathe.
RESPIRATORY TRAINING. Objectives + Why are respirators are necessary + Capabilities & Limitations + Inspecting & Maintaining + Medical Clearance & Fit.
Procedure for Operating Leaf Blowers (Revision 1 – 17th November 2010) Toolbox Talk.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
EVAHL The EVA PAPR for Hazardous Locations Updated February 12, 2013.
Copyright © 2016 by The S.E.A. Group
Respiratory Protection Program
CTE Respiratory Protection Training
Respirator Terminology
Ensures compliance with OSHA 29 CFR
Part 2 – Supplied-air Respirators
Respiratory injuries can seriously affect your health
Disaster Site Worker Safety
Disaster Site Worker Safety
Presentation transcript:

Bullard PA20 Powered Air Purifying Respirator (PAPR) Training Material

PA20 Principle of Operation 1 A PA20 Powered Air Purifying Respirator System consists of four components (Figure 1): Hood (1) Breathing Tube (2) Blower Unit (3) High Efficiency Particulate (HEPA) Filter (Internal, Not Shown) 2 3 Figure 1

Proper Use & Warnings Know the work environment and the potential hazards that could exist. Leave area immediately if: - Breathing becomes difficult - Dizziness or other distress occurs - Unit becomes damaged - Battery alarm sounds This apparatus must not be worn with the blower unit switched off. If the blower is switched off, a rapid build-up of carbon dioxide and depletion of oxygen may occur, which could result in death or serious injury. Never alter or modify this respirator. Use only NIOSH approved PA20 components and replacement parts for this respirator.

Assembly Attach Breathing Tube to Blower Unit, ensuring gray seal is in place (Figure 2). Ensure that filter assembly is installed into blower unit housing. Hoods have a sewn-in breathing tube connector on the back. The breathing tube has a special connector on the hood end with bayonet type pins. Insert the bayonet connector of the breathing tube into the hood connector and turn clockwise until it locks into place (Figure 3). Remove tissue from hood lens. Figure 2 Figure 3

Donning / Doffing Donning / doffing should take place in a clean and hazard-free environment. To Don: Place the blower unit with the breathing tube facing up against the back and buckle belt around the user’s waist. Adjust the belt for a proper fit prior to buckling. Turn on the blower unit Place the hood on the head and adjust the suspension for a comfortable and secure fit. To Doff: Remove hood from head. Turn off the blower unit. Unbuckle belt and place on flat surface. Remove used hood and dispose. When finished, leave PAPR in dirty utility room to be picked up by Distribution.

Low Voltage Audible Alarm The alarm may indicate: Low Battery Voltage Clogged or Damaged Filter Blower Malfunction Breathing Tube or Hood Malfunction If the alarm sounds, exit the work area immediately and return PAPR to dirty utility to be picked up by Distribution.

If you have any questions, please contact the Environmental Health and Safety office at 617-667-3088. (If after hours, page the on-call Safety Officer pager # 33137)