ATC Calculation Process

Slides:



Advertisements
Similar presentations
2 Draft of proposed metrics for the WEQ BPS to conduct analysis and evaluation of the Parallel Flow Visualization pilot project. (PFV Pilot)
Advertisements

Parallel Flow Visualization Data Requirements Parallel Flow Visualization Data Requirements NERC ORS Meeting Toronto, Ontario September 23-24, 2009 Jim.
NAESB Coordinate Interchange Version 1 Standard Revision 1, Draft 5 August, 2005.
Interchange Distribution Calculator Working Group (IDCWG) Update IDCWG October 12 th, 2011.
NAESB Coordinate Interchange
Interchange Distribution Calculator Working Group (IDCWG) Update NAESB BPS Yasser Bahbaz – IDCWG Chair September 13 th, 2012.
Definition of Firm Energy and Interruptible Transmission Two Issues Causing Problems for Business in the Western Interconnection.
NERC TPL Standard Issues TSS Meeting #146 Seattle, WA August 15-17, 2007 Chifong Thomas.
Operating Reserves --- Again A Discussion Primer
BAL-002-WECC-1 Contingency Reserves
Cleco Transmission Planning Summit Attachment K November 15, 2007 Terry Whitmore.
FERC Order minute Scheduling.
Al McBride MANAGER, AREA TRANSMISSION PLANNING Existing Import Interfaces: Transmission Transfer Capabilities and The Calculation of Tie Benefits DECEMBER.
Reliability Software1 Reliability Software Minimum requirements & Best practices Frank Macedo - FERC Technical Conference July 14, 2004.
Oasis Overview. 2 OASIS Overview What is OASIS? S –Open Access Same Time Information System –Electronic site for transmitting utility information to customers.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Thursday, November 5, :00 to 3:00 p.m. EST.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Thursday, August 26, :00 to 3:00 p.m. EDT.
Duke Energy Carolinas Stakeholder Meeting Independent Entity Services September 12, 2008.
Pseudo-Tie Reservations
System Voltage Planning Brian Moss PD / Transmission Planning Transmission Planning Overview October 30, 2007.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Thursday, January 19, :00 to 4:00 p.m. EST 4 th Quarter
SPP.org 1. 2 Aggregate Transmission Service Study (ATSS)
111 TAG Meeting June 8, 2015 Teleconference / Webinar FINAL.
NERC Congestion Management Congestion Management Option 3 Vendor Meeting Julie Pierce – NERC IDCWG Chair.
2-Tier Firm Curtailment: First-to-Curtail & Last-to-Curtail Examples NAESB BPS: August 9-10,
Business Practices Subcommittee
2006 Reliability Study Scope Name Date. DRAFT 2 Purpose of Study Assess the PEC and Duke transmission systems’ reliability Develop a single reliability.
2013 Calendar Year Customer Survey Results
OASIS Overview Transmission Customer Forum May 8-9, 2008 Jim Viikinsalo May 8-9, 2008 Jim Viikinsalo.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Thursday, December 2, :00 to 3:00 p.m. EDT.
Peak RCCo Performance Metrics Draft –November 2013.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Thursday, May 13th, :00 to 3:00 p.m. EDT.
OASIS Insights & Observations Transmission Customer Forum September 21-22, 2006 Jim Viikinsalo September 21-22, 2006 Jim Viikinsalo.
2014 Calendar Year Customer Survey Results. Background Open for comment February 12, 2015 through March 31, 2015 for evaluation of prior year – 21 close.
Business Practices Subcommittee Update Executive Committee Meeting February 18, 2014.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Thursday, May 19, :00 to 4:00 p.m. EDT 2 nd Quarter 2011.
ATC/TTC Basics Transmission Customer Forum Doug McLaughlin 9/22/06 Transmission Customer Forum Doug McLaughlin 9/22/06.
Duke Energy Carolinas Quarterly Stakeholder Meeting Independent Entity Services Tuesday, April 21, :00 to 3:00 p.m. EDT.
Overview of Southern Company Transmission
Flowgate Allocation Option Parallel Flow Visualization Business Practices Subcommittee Meeting June , 2010.
Parallel Flow Visualization Project NERC ORS Meeting May 4, 2011.
AFC METHODOLOGY EMS USER GROUP SEP 12, 2004 AFC – New Developments EMS USER GROUP Sep
Entergy AFC Stakeholder Meeting February 16, 2005 Houston, TX.
October 6, 2006 Public Stakeholder Review Portland, Oregon Conditional Firm.
NAESB WHOLESALE ELECTRIC QUADRANT BUSINESS PRACTICES SUBCOMMITTEE ACTIVITIES UPDATE TO JOINT ELECTRIC SCHEDULING SUBCOMMITTEE JANUARY 5, 2012 BY ED SKIBA.
1 Model Data Collection Meeting Announcement Entergy Transmission Planning Summit New Orleans, LA July 8, 2004.
2013 Wind Conference. Transmission Service Study Process Steve Purdy.
Generator Prioritization Option Parallel Flow Visualization Business Practices Subcommittee Meeting June , 2010.
Target Reserve Margin (TRM) and Effective Load Carrying Capability (ELCC) of Wind Plants Evaluation - Input and Methodology ERCOT Planning 03/25/2010.
1. Non-Dispatchable Resources and EIS Market Carrie Simpson May 30,
Duke Energy Carolinas Transition to AFC Methodology Stakeholder Meeting Independent Entity Services Thursday, March 17, :00 to 3:00 p.m. EDT.
NAESB BPS Yasser Bahbaz– IDCWG Chair January 5 th, 2016.
Entergy AFC Stakeholder Meeting March 9, 2005 Houston, TX.
RAWG Agenda Item LAR Data WECC Staff. Data Elements Generator information – Existing – Changes Monthly Peak Demand and Energy (actual year and.
Coordinated Planning Concept (For Discussion Only) revised 11/30/04 07/01/04.
PJM©2014www.pjm.com A System Operator’s Resilience Wish List Tom Bowe Executive Director Reliability and Compliance PJM Interconnection
2006 Reliability Study James Manning Bryan Guy May 12, 2006.
NAESB BPS UPDATE TO EXECUTIVE COMMITTEE AUGUST 21, 2012 BY NARINDER K SAINI ED SKIBA BPS-CO-CHAIRS PARALLEL FLOW VISUALIZATION PROJECT 1.
Compare and Contrast Reliability Assumptions Bob Pierce May 12, 2006.
Transmission Team Lead
Duke Energy Carolinas Quarterly Stakeholder Meeting
Pseudo-tie business procedure
DEC System Voltage Planning - June 2018
Review of After-the-Fact (ATF) Tagging Criteria Scheduler’s Meeting May 24, 2016 Raymond will ask the audience what their expectations are in regard to.
Duke Energy Carolinas Quarterly Stakeholder Meeting
DEC/DEP ATC Methodology Consolidation
Review of After-the-Fact (ATF) Tagging Criteria Scheduler’s Meeting May 24, 2016 Raymond will ask the audience what their expectations are in regard to.
Two-Tier Firm Curtailment Overview
NERC Congestion Management
Pseudo-tie business procedure
Presentation transcript:

ATC Calculation Process ATC Training Duke Energy Carolinas ATC Calculation Process December 15th, 2011

Agenda Objectives Introduction Flowgate methodology basics Data Inputs AFC Calculation Posted ATC

ATC Training Objectives

Objectives High-level understanding of new Available Transfer Capability (ATC) Process Inputs to the ATC process How inputs affect the ATC process Transfer Distribution Factors (TDFs) How ATC is calculated

ATC Training Introduction

How Did We Get Here? Legislative Timeline Change Order signed with OATi Mar Discussion on switching to AFC begins Dec OATi delivered AFC system to test Sep 2011 Aug Tested AFC process Decision made to switch to AFC Jan Implemented AFC process Evaluation of FERC order 729/676-E impacts 2007 2008 2009 2010 Legislative Timeline Feb Nov Apr 2007 2008 2009 2010 2011 FERC order 890 FERC orders 729/676-E Effective date of FERC orders 729/676-E Effective date of NERC MOD Standards

Duke Energy Carolinas ATC Process Implemented the Flowgate Methodology NERC MOD-030 Reliability Standard Two (2) main components to process Model Builder (PowerGEM TARA AMB) ATC Calculator (OATi webTrans) Automated Process Increased the level of required coordination with other TSPs TSRs Flowgates Tags Generation Dispatch Files Outages Load Forecasts AFC Values

Flowgate Methodology Basics ATC Training Flowgate Methodology Basics

What is a Flowgate? NERC defines a Flowgate as: More simply put: A mathematical construct, comprised of one or more monitored transmission Facilities and optionally one or more contingency Facilities, used to analyze the impact of power flows upon the Bulk Electric System. More simply put: A Flowgate is a transmission line or transformer that is being monitored for overloads incurred by normal operating conditions or for loss of another transmission line or transformer

Flowgate Identification Flowgate identification is performed at least annually Identifies list of Flowgates internal to Duke Energy Carolinas Screens external Flowgates and includes those that meet/exceed criteria An external TSP can request Duke Energy Carolinas to incorporate their Flowgates into the Duke Energy Carolinas process Duke ATC process currently contains 670 Flowgates 379 internal DUK Flowgates & 291 External Flowgates Breakout of Flowgates in Duke Process by TSP DUK CPL PJM SC SCEG SOCO TVA Total 379 56 82 62 50 29 12 670

What is AFC? Available Flowgate Capability NERC defines AFC as: A measure of the flow capability remaining on a Flowgate for further commercial activity over and above already committed uses. More simply put: AFC is the commercial capability remaining on the Flowgate.

ATC Training Data Inputs

ATC Process Overview Model Builder (PowerGem) ATC Calculator External TSP AFC Overrides Adjacent TSP Reservations Duke TSP flowgates FG Definition File External TSP flowgates Shift Factors Model Builder (PowerGem) ATC Calculator (webTrans) Seed Case Outages Base Flow Load Forecast Tags TFC Gen Dispatch Files Duke Reservations Adjacent TSP Gen Dispatch Files Duke webOASIS ATC

Adjacent TSP TSRs Process includes TSRs from adjacent TSPs Old process only contained DUK TSRs Filtered to remove duplicate TSRs Must have TDF greater than 5% Adjacent TSRs provided by adjacent TSP Availability/accuracy based on adjacent TSP ATC Calculator downloads/applies Adjacent TSP TSRs OATi webTrans Applies Adjacent TSP TSRs at horizon initialization Coordinating TSPs CPL, PJM, SC, SCEG, SOCO, SEHA, SETH, TAP, TVA, YAD

External TSP Flowgates Duke Energy Carolinas includes Flowgates outside of its system in the ATC process Called “External Flowgates” Owned by another Transmission Service Provider (TSP) Flowgates that are not owned by Duke Energy Carolinas Includes any Flowgate in the VACAR Reliability Coordinator Area that had a TLR called in past 12 months At the time the list of Flowgates was created Any TSP can request Duke Energy Carolinas to honor their Flowgates Must be included in requesting TSP’s ATC process Must already be modeled Must pass Flowgate screening test

External TSP AFC Overrides Duke Process Includes AFC Overrides from adjacent TSPs Applied to External Flowgates Replaces (overrides) the AFC value calculated by DUK Provided by coordinating TSP Availability/accuracy based on adjacent TSP If provided, DUK is REQUIRED to use the AFC value. If not provided, DUK utilizes value calculated by DUK process ATC Calculator downloads/applies External AFC Overrides OATi webTrans applies AFC Overrides at horizon initialization Horizon definitions are included in the ATCID (link)

Seed Case Starting point powerflow model Inputs of the AFC process (Outages, Load, etc) modify the Seed Case to create a model representative of the calculation period Based on SERC Near-Term Study Group OASIS Studies Model is modified to account for mapping concerns (alignment with NERC IDC, SDX, etc) and handling of base case transfers ensure that outages, load forecasts, etc can be mapped correctly avoid double counting of TSR or tag impacts in the calculation of AFCs. Developed quarterly for next 5 seasons

Outages Download Outages from NERC SDX Outages built into Seed Case Industry standard database Transmission & generation outages Utilize outages from: Duke Energy Carolinas All adjacent TSPs Outages built into Seed Case Refer to the outage criteria in the ATCID (link) Transmission Outages are viewable on OASIS Requires certificate Only Duke Energy Carolinas

Load Forecasts Download load data from NERC SDX Industry standard database Utilize data from: Duke Energy Carolinas All adjacent TSPs, except PJM Download load data from PJM PJM provides a file that breaks out their load into each legacy BA (increases model accuracy) Forecasted/Actual Load Data are viewable on OASIS Requires certificate Only Duke Energy Carolinas System load Native load

Tags Download tag data from NERC Tag Dump Modeling of Tags Industry standard database Utilize data from: Duke Energy Carolinas All adjacent TSPs Modeling of Tags Capacity modeled is the Transmission Profile MWs Utilize the GCA/LCA to model receipt & delivery points Adjusts net area interchange of GCA/LCA Tag impacts will be due to physics, not market path IPPs internal to DUK utilize the Source & LCA Adjusts the output of the specific generator and the net area interchange of GCA/LCA

Tags Continued… Tags affect the amount of generation dispatched in the Duke Energy Carolina TSP area Generation is dispatched to meet load + net area interchange + losses Tags sinking in Duke will decrease the generation dispatched Tags sourcing from Duke will increase the generation dispatched Tags will impact the amount of generation dispatched which impacts baseflows of impacted Flowgates Based on physics not the market path Some Flowgates are more sensitive to generation than others

Generation Dispatch Files Duke Energy Carolinas generation dispatch Block Dispatch File Groups units into blocks based on dispatch order (typically economics) Direct Dispatch Files Pumped Storage (based on Duke unit commitment 7-day outlook forecast) IPPs – Based on tags in hourly operating horizon Adjacent TSP generation dispatch Block Dispatch File (provided by adjacent TSP) Direct Dispatch Files (if provided)

ATC Training AFC Calculation

ATC Process Overview Model Builder (PowerGem) ATC Calculator External TSP AFC Overrides Adjacent TSP Reservations Duke TSP flowgates FG Definition File External TSP flowgates Shift Factors Model Builder (PowerGem) ATC Calculator (webTrans) Seed Case Outages Base Flow Load Forecast Tags TFC Gen Dispatch Files Duke Reservations Adjacent TSP Gen Dispatch Files Duke webOASIS ATC

Baseflows Calculated by the Model Builder (PowerGEM TARA AMB) MW flow on each flowgate Imported to ATC Calculator (OATi webTrans) Baseflow values are adjusted to prevent double impacts Performed in the ATC Calculator (OATi webTrans)

Shift Factors (GSFs) Generation Shift Factors (GSFs) measures the sensitivity of a flowgate due to an incremental change in generation dispatch from a subsystem Subsystem created for each Control Area (CA) in Eastern Interconnect Each company represented by an import & export subsystem Duke process contains roughly 106 subsystems Each subsystem has a factor relating to each Flowgate 106 subsystems X 670 Flowgates = 71,020 sensitivity factors for each powerflow snapshot Hourly48 file contains 71,020 X 48 hours = 3,408,960 sensitivity factors

Transfer Distribution Factors (TDFs) Portion of a transaction that flows across a Flowgate Expressed as a percentage (%) Based on Generation Shift Factors (GSFs) TDF = GSFPOR – GSFPOD Means TDF is dependent on the Source (POR) & Sink (POD) Control Areas (CAs) change in generation dispatch to facilitate the transfer Used to determine/calculate: How much each TSR impacts a Flowgate Which Flowgates impact a Path The ATC of a Path

How much will my TSR impact a particular Flowgate? Depends on the TDF TSR Flowgate Impact = Granted MW Capacity X TDF Will need to calculate TSR impact on each impacted Flowgate Example: TSR = 100 MW TDF on Flowgate “A” = -2.32% TSR Flowgate Impact (Flowgate A) = 100 X -2.32% = -2.32 MWs TDF on Flowgate “B” = 5.01% TSR Flowgate Impact (Flowgate B) = 100 X 5.01% = 5.01 MWs

Which Flowgates impact Path “XYZ”? Depends on the TDF of each Flowgate If Flowgate TDF >= to Flowgate threshold, Flowgate is impacted 3% for Duke Flowgates 5% for all other Flowgates Example: Using the threshold above, what Flowgates impact DUK-PJM? TDF on Flowgate “A” = -.0232 (-2.32%) owned by DUK Does not impact DUK-PJM, Flowgate TDF < Flowgate threshold (3%) TDF on Flowgate “B” = .0501 (5.01%) owned by TVA Impacts DUK-PJM, Flowgate TDF (5.01%) > Flowgate threshold (5%) Remember TDFs are based on Shift Factors (GSFs) Means TDF is dependent on how the Source (POR) & Sink (POD) CAs respond to a Flowgate

Example - Why is there ATC on CPLE-PJM but not DUK-PJM? Completely different and independent Paths Because the two Paths are different, Flowgates impact the Paths differently TDFs are based on Shift Factors (GSFs) Means TDF for each Flowgate is dependent POR & POD Path DUK-PJM has POR = DUK & POD = PJM Path CPLE-PJM has a POR = CPLE & POD = PJM Paths are not the same Because POR & POD are not the same

Example - Why is there ATC on CPLE-PJM but not DUK-PJM? PJM generation is scaled down for import PJM generation is scaled down for import PJM Gen scaled down PJM Gen scaled down DUK No changes The Difference Is DUK generation does not change DUK Gen scaled up Flowgates can be more sensitive to gen dispatch in one area vs another area CPLE Gen scaled up DUK generation is scaled up for export CPL generation is scaled up for export

Process Timing &Calculation of Posted ATC ATC Training Process Timing &Calculation of Posted ATC

ATC Process Overview Model Builder (PowerGem) ATC Calculator External TSP AFC Overrides Adjacent TSP Reservations Duke TSP flowgates FG Definition File External TSP flowgates Shift Factors Model Builder (PowerGem) ATC Calculator (webTrans) Seed Case Outages Base Flow Load Forecast Tags TFC Gen Dispatch Files Duke Reservations Adjacent TSP Gen Dispatch Files Duke webOASIS ATC

ATC Process Timing Schedule Calculation of ATC values ATC adjusted automatically as TSRs change status Uses existing model output (baseflows, sensitivity factors, etc.) ATC recalculated automatically as Model Builder data imported ATC recalculated at horizon initialization ATC Calculator Inputs OATi monitors coordinating TSPs for data downloads TSRs AFCs Model Builder data OATi monitors FTP site every 15 mins for data

ATC Process Timing Schedule Continued… Model Builder Data Script runs hourly to download the following inputs: Load forecasts, Outages, Tags Model creation schedule: Model Builder data sent to FTP site for ATC Calculator Model Series Frequency Hourly Non-Firm (near-term) Every hour (5 mins after hour) Hourly Firm (5 mins before hour) Hourly (long-term) 7:30, 12:30, 15:30, 23:30 Daily 7:15, 14:30, 22:30 Monthly 9:30, 13:30, 21:30 Only required to be updated once/day Only required to be updated once/month

Posted ATC How is ATC calculated? ATC calculated by “ATC Calculator” It is the minimum of the equivalent ATC from the AFC methodology and the Remaining Contract Path Capability (RCPC) Ensures Flowgates are respected as well as the contract path interface limits ATC calculated by “ATC Calculator” OATi webTrans software used as “ATC Calculator” Exports ATCs to OASIS System Data & Offerings

Posted ATC Continued… Converting AFCs to an ATC equivalent Driven by AFC value and TDF of each flowgate relative to path Calculated by following the two steps below: Divide every “impacted” Flowgate AFC by it’s associated path TDF “Impacted” Flowgates are those who’s TDFs are >= to the threshold (3% for internal Flowgates or 5% for external Flowgates) The equivalent ATC is the minimum value from the above calculations Remaining Contract Path Capability (RCPC) Similar to old Area Interchange Methodology (aka Contract Path)

Wrap up Change to AFC Methodology driven by new NERC MOD Standards NERC significantly changed the standard related to our old Area Interchange Methodology (aka Contract Path Methodology) Process frequency significantly increased Automated process to run more frequently than our previous Area Interchange Methodology. To meet/excede requirements. This process is much more dependent on data Most inputs are dynamic and can change throughout the day Utilizes significantly more data from other companies The points mentioned above cause a dynamic calculation ATC values will change as data inputs change Values should be better aligned with actual system conditions

For More Information… ATCID – Posted on OASIS (link) Attachment C of the OATT – posted on OASIS (link) ATC Methodology Contact dukencieatc@misoenergy.org (651) 632-8708 Is there a need for additional ATC/AFC training? Was this presentation helpful?

Questions? E-mail: dukencieatc@misoenergy.org Phone: (651) 632‐8708

ATC Training Appendix

ATC Process Overview Model Builder (PowerGem) ATC Calculator External TSP AFC Overrides Adjacent TSP Reservations Duke TSP flowgates FG Definition File External TSP flowgates Shift Factors Model Builder (PowerGem) ATC Calculator (webTrans) Seed Case Outages Base Flow Load Forecast Tags TFC Gen Dispatch Files Duke Reservations Adjacent TSP Gen Dispatch Files Duke webOASIS ATC

Transfer Distribution Factors (TDFs) Continued… How do you calculate a TDF for a particular Flowgate? Example: What is the TDF of Flowgate A with respect to the DUK-CPLE Path TDF = GSFPOR – GSFPOD From table below: GSFPOR = DUK_R = -.0036 GSFPOD = CPLE_D = .01696 TDF = -.0036 - .0196 = -.0232 = -2.32%

Converting AFCs to an ATC equivalent ATCAFC = min(P) P ={PATC1, PATC2,…PATCn} PATCn = AFCn / DFnp Where: ATCAFC = ATC of a Path p based on AFCs P = set of partial ATCs for all “impacted” Flowgates of Path p PATCn = partial ATCs for a Path relative to a Flowgate n AFCn = AFC of Flowgate n DFnp = Distribution Factor of Flowgate n relative to the Path p

Remaining Contract Path Calculation Remaining Contract Path Capability (RCPC) Represents the remaining capacity of Contract Path Similar to old Area Interchange Methodology (aka Contract Path) Firm Equation – All Horizons RCPC = CP Limit – TRM – CBM - Conf Firm TSRs Non-Firm Equation – Prior to 08:00 day prior RCPC = CP Limit – TRM – CBM – Conf Firm TSRs – Conf Non-Firm TSRs Non-Firm Equation – After 08:00 day prior RCPC = CP Limit – TRM – CBM – Sch Firm – Conf Non-Firm TSRs