Ceiling Radiant Cooling Panels as a Viable Distributed Parallel Sensible Cooling Technology Christopher L. Conroy, E.I.T. L. D. Astorino Companies, Pittsburgh.

Slides:



Advertisements
Similar presentations
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Advertisements

DOUG BOSWELL MECHANICAL OPTION APRIL 16, 2008 Temple University Tyler School of Art.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Kevin Edstrom Mechanical Option 2011 Senior Thesis April 12 th, 2011 Georgetown University New Science Center Washington, DC.
Heat Recovery for Commercial Buildings
Technology in Architecture Lecture 10 Mechanical Systems Lecture 10 Mechanical Systems.
Innovative Air Distribution for Healthcare Facilities.
pae consulting engineers, inc. Nick Collins, P.E., LEED™ AP
Chilled Beam Presentation
STEM Center Delaware County Community College – Media, PA Thesis Final Presentation Dan Saxton Mechanical Option.
Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering PSU, Univ. Park, PA Web: Chilled Surfaces:
1 Condensation Control Experiences in an “historic” Building with Movable Sash ASHRAE Anaheim Seminar 53, 1/28/04 Stanley A. Mumma, Ph.D., P.E. Professor,
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
1 Decoupling the Building Latent and Sensible Loads Using 100% Outside Air Systems ASHRAE Chicago Seminar 39 January 24, 2006 Stanley A. Mumma, Ph.D.,
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
WESTINGHOUSE ELECTRIC NUCLEAR ENGINEERING HEADQUARTERS DANIEL AUGHENBAUGH - MECHANICAL OPTION Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh.
Field Experience Controlling a Dedicated Outdoor Air System (DOAS)
Web Based BACnet Compatible Controls Applied to Emerging HVAC Technologies Stanley A. Mumma, Ph.D., P.E. Prof. Architectural Engineering Penn State University.
Bowie State University Fine and Performing Arts Center Zachary Lippert Faculty Advisor: Dr. Stephen Treado.
PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Kurt M. Shank, M.S. & Stanley A. Mumma, Ph.D., P.E. College of Engineering Department.
Lecture Objectives: Final discussion about HW3 Introduce more final project topics Continue with HVAC Systems.
1 Stanley A. Mumma, Ph.D., P.E. Professor Emeritus Penn State Univ. Park, PA Web: Active and Passive.
Ductless Heat Pumps Sizing Example
North Pocono High School
HVAC for Educational Facilities
CENTRAL HIGH SCHOOL Central High School MID-ATLANTIC REGION ADAM BROWN MECHANICAL OPTION SPRING 2014 Introduction Existing Mechanical System Thesis Proposal.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
Lindab Solus - Simply the natural choice.... lindab | comfort Chilled beam revolution! + Save up to 45 % cooling energy!* + Installation and investment.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
N O R T H A M E R I C A C O M M E R C I A L TDP
Direct Digital DBT, %RH, and Condensate Control for a DOAS-CRCP system ASHRAE Winter Meeting Symp. 3, Orlando-Feb. 6, 2005 Stanley A. Mumma, Ph.D., P.E.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Spring 2007 Senior Thesis Justin D. Schultz Mechanical Option The Hauptman-Woodward Medical Research Institute Dedicated Outdoor Air Applications at the.
APPELL LIFE SCIENCES York College of Pennsylvania Joshua Martz | Dr. Srebric | April 11, 2011 Image Courtesy of RLPS, Ltd.
2003 ASHRAE Annual Meeting Kansas City Energy Conservation Benefits of a DOAS with Parallel Sensible Cooling by Ceiling Radiant Panels Jae-Weon Jeong Stanley.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA 2014 Conference Presentation.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Straumann USA 60 Minuteman Road Andover, MA Kevin Kaufman Mechanical Option The Pennsylvania State University Architectural Engineering.
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.
Radiant Cooling. For cooling applications, the building mass (floor, ceiling and walls if necessary) is cooled, which forms a sink to absorb energy from.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
The regional learning alliance At Cranberry Woods. CAITLIN HANZEL MECHANICAL OPTION THE PENNSYLVANIA STATE UNIVERSITY THE DEPARTMENT OF ARCHITECTURAL ENGINEERING.
Application of Ceiling Radiant Cooling in a University Environment ASHRAE Chicago Seminar 7, 1/26/03 Stanley A. Mumma, Ph.D., P.E. Professor, Architectural.
Alexander Radkoff Mechanical Option | Spring 2014 Advisor: Dr. Stephen Treado 123 Alpha Drive Pittsburgh, Pennsylvania
NOLAN JAMES AMOS Dr. William Bahnfleth, Faculty Consultant architectural engineering senior thesis mechanical option PHOENIXVILLE EARLY LEARNING CENTER.
Manoa Elementary School Amanda Cronauer Faculty Advisor: Dr. William Bahnfleth 14 April 2010.
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
Keith Beidel AE – Mechanical Option ’03 Penn State University Senior Thesis Centre Community Hospital – East Wing Addition Radiant Cooling In an Intensive.
Radiant 101 Casey Swanson & Him Ly. 29 June 2016©Uponor2 Terms and Definitions AUST- Average Uncontrolled Surface Temp. ― Area-weighted of all interior.
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Capital Projects Requests
BUILDING HEATING AND COOLING
David Anderson Mechanical Option
Redifer Commons Addition & Renovation Project
Grunenwald Science and Technology Building
Achieving Net Zero with a 649,848 Sq. Ft. Industrial Complex
Conduction Cooling Loads
Munters DOAS, Chilled Beams and VRV
Munters DOAS and Chilled Beams
Chapter 18A: ALL-WATER HEATING AND COOLING SYSTEMS
Biobehavioral Health Building, University Park, PA
The Ed Roberts Campus Berkeley, CA Introduction Existing Systems
INNOVATION lab MEP MECHANICAL/ELECTRICAL/PLUMBING :
FBE03: Building Construction & Science
Technology in Architecture
Professor of Architectural Engineering College of Engineering
Announcements Exam 1 Next Class (Thursday, March 14th):
Presentation transcript:

Ceiling Radiant Cooling Panels as a Viable Distributed Parallel Sensible Cooling Technology Christopher L. Conroy, E.I.T. L. D. Astorino Companies, Pittsburgh PA Stanley A. Mumma, Ph.D., P.E. Penn State University, Dept. of Architectural Engineering Christopher L. Conroy, E.I.T. L. D. Astorino Companies, Pittsburgh PA Stanley A. Mumma, Ph.D., P.E. Penn State University, Dept. of Architectural Engineering Integrated with Dedicated Outdoor Air Systems

Presentation Overview Introduction Radiant Cooling Theory HVAC Paradigm Advantages Example Integration of Fire Suppression Conclusions and Solutions Introduction Radiant Cooling Theory HVAC Paradigm Advantages Example Integration of Fire Suppression Conclusions and Solutions

Integrating Dedicated Outdoor Air Systems with Parallel Terminal Systems Radiant Cooling Panels Fan Coil Units Air Handling Units Unitary ACs Unit Ventilators

Radiant Cooling Theory Uses both Radiation and Convection Radiation (50-60%) »Stefan-Boltzmann Equation »q r = 0.15x10 -8 · [(t p +460) 4 – (t a +460) 4 ] Convection (40-50%) »ASHRAE S&E 1996 »q c = 0.31 · |t p - t a | 0.31 · (t p - t a ) Uses both Radiation and Convection Radiation (50-60%) »Stefan-Boltzmann Equation »q r = 0.15x10 -8 · [(t p +460) 4 – (t a +460) 4 ] Convection (40-50%) »ASHRAE S&E 1996 »q c = 0.31 · |t p - t a | 0.31 · (t p - t a )

Radiant Cooling Paradigm Expensive »High first cost »Difficult or improper installation »Unavailable Expensive »High first cost »Difficult or improper installation »Unavailable Condensation!!!

Radiant Cooling Panel Construction Copper Tubing (Serpentine or Parallel Arrangement) Copper Tubing (Serpentine or Parallel Arrangement) Aluminum or Copper Fins Thermally Bonded Blanketed with Insulation

Cost Advantages Long Term Savings »Smaller, More Efficient Chillers »Reduced Fan Energy »Reduced Maintenance Cost »Not paying for Over Ventilating Other Cost Savings »Piping is not insulated »Reduced Sprinkler Piping »Testing and Balancing Made Simpler Long Term Savings »Smaller, More Efficient Chillers »Reduced Fan Energy »Reduced Maintenance Cost »Not paying for Over Ventilating Other Cost Savings »Piping is not insulated »Reduced Sprinkler Piping »Testing and Balancing Made Simpler

Indoor Air Quality Advantages High comfort levels No condensate drains or drain pans Meets ANSI/ASHRAE Std Quick response time Individual room control at low cost High comfort levels No condensate drains or drain pans Meets ANSI/ASHRAE Std Quick response time Individual room control at low cost

Building Advantages Architecturally Integratable »Silk screening available »Perforated face (acoustics) Great for Retrofit or New Construction »Reduces Mechanical Space »Less Ductwork –Less vertical shaft space –Higher ceilings and/or reduced building heights Simpler Coordination Between Trades »Integration of fire suppression »Less interferences (crossover ductwork) Architecturally Integratable »Silk screening available »Perforated face (acoustics) Great for Retrofit or New Construction »Reduces Mechanical Space »Less Ductwork –Less vertical shaft space –Higher ceilings and/or reduced building heights Simpler Coordination Between Trades »Integration of fire suppression »Less interferences (crossover ductwork)

Example: Step 1 Defining Parameters Open Office Plan »1000 ft 2 Define Design Conditions »78ºF DBT / 40% RH »7 People (20 cfm/person) Space Loads »7 People (Office Work) »2 W/sq ft (Lighting) »1 W/sq ft (Equipment) »4,000 Btu/h (Skin Loss) Open Office Plan »1000 ft 2 Define Design Conditions »78ºF DBT / 40% RH »7 People (20 cfm/person) Space Loads »7 People (Office Work) »2 W/sq ft (Lighting) »1 W/sq ft (Equipment) »4,000 Btu/h (Skin Loss) »14,000 Btu/h (Total Sensible) »1,435 Btu/h (Total Latent) »14,000 Btu/h (Total Sensible) »1,435 Btu/h (Total Latent) 1000 ft 2 78°F / 40%

Step 2 Estimation of CRCP Capacity

Step 3 Calculation of CRCP Capacity Room DPT = 52°F »78°F / 40% RH DOAS DPT = 44°F »1,435 Btuh Latent Load »140 55°F »3,500 Btuh Sensible Load Room DPT = 52°F »78°F / 40% RH DOAS DPT = 44°F »1,435 Btuh Latent Load »140 55°F »3,500 Btuh Sensible Load Panel t fi = 55°F Panel Temp = 60°F Q s = 29.7 Btuh/ft 2 »10,500 Btuh »354 ft 2 of panel Panel t fi = 55°F Panel Temp = 60°F Q s = 29.7 Btuh/ft 2 »10,500 Btuh »354 ft 2 of panel

Step 4 Selection and Layout of CRCP 126 4x2 Ceiling Panels »~ 1000 ft 2 24 Light Fixtures »~ 20% of Ceiling 49 Ceiling Radiant Cooling Panels »392 ft 2 (40%) 400 sq. ft. Leftover »Diffusers »Sprinklers Q s = 26.7 Btuh/ft2 »Room RH = 43% »Increase DOAS DPT 126 4x2 Ceiling Panels »~ 1000 ft 2 24 Light Fixtures »~ 20% of Ceiling 49 Ceiling Radiant Cooling Panels »392 ft 2 (40%) 400 sq. ft. Leftover »Diffusers »Sprinklers Q s = 26.7 Btuh/ft2 »Room RH = 43% »Increase DOAS DPT

Step 5 Compare Acoustical Performance of CRCP Acoustical Ceiling Vs CRCP Frequency (Hz) Reverberation Time (sec)

Chilled Water Loop TZONEVALVESZONEVALVESCRCP’sCRCP’s SECONDARYPUMP(VFD)SECONDARYPUMP(VFD) COMPRESSIONTANKCOMPRESSIONTANK MAKE-UPPUMPMAKE-UPPUMP

Integrated Fire Suppression System CHECKVALVECHECKVALVE ALARMVALVEALARMVALVE FIREFLOWSWITCHFIREFLOWSWITCH FIREPUMPASSEMBLYFIREPUMPASSEMBLY

Conclusions and Solutions Seen the Advantages Concluded that CRCP’s can be Used Safely with No Condensation Problems Defined a Simple Selection Process Examined the Opportunity for Fire Suppression Integration Seen the Advantages Concluded that CRCP’s can be Used Safely with No Condensation Problems Defined a Simple Selection Process Examined the Opportunity for Fire Suppression Integration Break the HVAC Paradigm »More Successful Applications »Spreading the Word Explore the Possibilities of Lowering Cost »Increase Availability »Research a way to produce custom lengths on site Development Through the Solar Industry Break the HVAC Paradigm »More Successful Applications »Spreading the Word Explore the Possibilities of Lowering Cost »Increase Availability »Research a way to produce custom lengths on site Development Through the Solar Industry

Questions