1 Molecular Luminescence Spectroscopy Lecture 31.

Slides:



Advertisements
Similar presentations
An introduction to Ultraviolet/Visible Absorption Spectroscopy
Advertisements

Raman Spectroscopy A) Introduction IR Raman
Fluorescence Fluorescent corals.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
Non-Instrumental Methods
Atomic Absorption Spectroscopy Prof Dr Hisham E Abdellatef 2011.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
Molecular Luminescence Spectrometry
Chapter 15 Molecular Luminescence Spectrometry Molecular Fluorescence  Optical emission from molecules that have been excited to higher energy levels.
Atomic Absorption Spectroscopy
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Introduction to Instrumental Analysis - Spectrophotometry
Fluorescence, Phosphorescence, & Chemiluminescence
Atomic Emission Spectrometry By: Alexa Kunch
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
Molecular Luminescence Spectroscopy Chapter 15 Fluorescence, Phosphorescence and Chemiluminescence.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Molecular Luminescence Spectroscopy
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
UV-Vis Absorption Spectroscopy
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Fluorometric Analysis
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Fluorescence Spectroscopy
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
Spectrofuorometer lab. 1. Fluorescence spectroscopy or (spectrofluorometry) Is a type of electromagnetic spectroscopy which analyzes fluorescence from.
Molecular Luminescence Spectroscopy
Fluorescence, Phosphorescence, & Chemiluminescence
Asa Arjoon U6 Chemistry Presentation on Visible and Ultraviolet Spectroscopy Name : Form : Subject :
Introduction to Spectrochemical Methods
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
1 Introduction to Atomic Spectroscopy Lecture 10.
Colorimeters or photometers
MOLECULAR FLUORESCENCE SPECTROSCOPY. Fluorescence is a form of photoluminescence; and this later is a type of luminescence that occurs when certain molecules.
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
Molecular Luminescence Spectroscopy
UV SPECTROSCOPY Absorption spectra.
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Fluorometric determination of riboflavin
1 Molecular Luminescence Spectroscopy Lecture 29.
hn1 hn2 optical l selector source sample detector signal processor
PHCM561t WS Lecture 4 LUMINESCENCE Quinine Dr. Rasha Hanafi
Molecular Fluorescence Spectroscopy
Principles of instrumentation. Photometry - Photometry means “the measurement of light” If a substance can be converted to a soluble, colored material,
GammaX-rayUVVisIRMicroRadio Short wavelength High energy High frequency Long wavelength Low energy Low frequency Solvent effects: Neat: has fine structure.
Flame Emission Spectrometry
Chem. 133 – 3/14 Lecture.
Non-Instrumental Methods
Colorimeters or photometers
Spectrophotometer Dr . S. Jayakumar.
Practical Absorbance and Fluorescence Spectroscopy
Colorimeters OR photometers
Raman Spectroscopy A) Introduction IR Raman
Molecular Luminescence Spectroscopy
SPECTROPHOTOMETRY Applied Chemistry.
Molecular Luminescence Spectrometry
Molecular Luminescence Spectroscopy
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Molecular Luminescence Spectroscopy
Presentation transcript:

1 Molecular Luminescence Spectroscopy Lecture 31

2 The relation F = KP 0  bc implies the following a. The fluorescence signal can be increased if the radiant power of the incident beam is increased. Therefore, always use more intense sources. b. The fluorescence signal is directly related to the molar absorptivity and thus molecules of higher molar absorptivities are better fluorescers. c. Fluorescence signal is directly proportional to path length. d. Fluorescence signal is directly proportional to concentration. This is different from relation between absorbance and concentration which is logarithmic. e. The linear correlation between fluorescence and concentration is only true when the absorbance is less than 0.05.

3 Deviation from Linearity between Fluorescence and Concentration Negative deviations from the linear relation between fluorescence and concentration may be observed in the following cases: a. At absorbances higher than b. Self-quenching whereby excited molecules lose their energies by collision with other molecules or solvent c. Self-absorption which occurs when an emission band overlaps with an excitation (absorption) band. In this case, emitted photons excite other molecules in the ground state which results in no net emission.

4

5

6 Fluorescence Instruments Like any emission instrument, a fluorescence or phosphorescence instrument consists of a source, wavelength selectors, a sample cell, a detector, as well as a signal processor. Two wavelength selectors are used, the first is the excitation filter or monochromator which excites the sample while the other is the emission filter or monochromator that separates the fluorescence or phosphorescence wavelength.

7 Sources We have seen earlier that the fluorescence signal is proportional to the radiant power of the source. Therefore, it is very important to select a source of as high radiant power as possible. In most instruments, a xenon arc lamp is usually the source of choice. However, some instruments use lasers.

8 Xenon Arc Lamp A quartz envelope hosting two electrodes and xenon at high pressure (5-10 atm). The discharge which takes place between the two electrodes excites xenon and produces a continuum in the range from nm. The wavelength maximum occurs at about 500 nm. The radiant power produced by a xenon arc lamp is very high which makes the lamp suitable for luminescence analysis. Also, the coverage of the whole UV-Vis range adds to the assets of the lamp. However, a very good regulated power supply is essential since any fluctuations of the radiant power will be directly reflected on the fluorescence signal.

9

10 Lasers We have seen examples of lasers early in this course. However, it should be indicated that since lasers may have very high intensities, some molecules, which are otherwise non fluorescents, show good fluorescence and can thus be determined by fluorescence spectroscopy. This is called laser induced fluorescence (LIF) and is a common technique in fluorescence spectroscopy. In addition, one should remember that as the radiant power is increased, photodissociation may become a problem especially at shorter excitation wavelengths.

11 1. Fluorometers When the wavelength selectors are filters, the instrument is called a fluorometer. It is a simple instrument that is usually used for quantitative analysis. The use of fluorometers implies that the excitation and emission wavelengths are predetermined by other means or are known from literature. The detector is usually a sensitive photomultiplier tube. A schematic of a simple fluorometer is shown below:

12

13

14

15 Unlike the cell used in UV-Vis absorption studies, the cell used in luminescence studies has the two transparent faces perpendicular to each other, rather than parallel. This is important since luminescence is collected 90 o to the incident beam. This configuration decreases the noise and fully excludes interferences from the incident beam.

16 2. Spectrofluorometers In this case, the excitation and emission wavelengths are selected using dispersive elements like gratings or prisms. The same instrumental configuration as fluorometers is usually used. The following schematic represents a basic configuration of a spectrofluorometer:

17

18

19

20 Excitation and Emission Spectra The first step in a successful fluorescence measurement is to determine the emission wavelengths. The emission spectrum is determined by adjusting the excitation monochromator at an arbitrary, but well selected, wavelength which is shorter than the anticipated emission wavelength. Keeping the emission monochromator at the obtained emission wavelength, the excitation spectrum is recorded by scanning the excitation monochromator in a range less than the emission wavelength of the emission monochromator.

21 After obtaining the excitation spectrum, the ex (resulting in highest absorbance) is determined. em is the wavelength with highest fluorescence signal. At this point we are ready to perform a fluorometric determination using the defined excitation and emission wavelengths. One can also start by collecting an absorption spectrum on a UV-Vis instrument. This will give approximate ex to start with, followed by collecting the emission spectrum. Then, after finding em, one can collect the excitation spectrum to get ex.

22 The shape of the emission spectrum is expected to be a mirror image of the excitation spectrum since they originate from opposite processes However, instrumental artifacts result in excitation and emission spectra that are not exactly mirror images.