1 LIFECARE PLV-100 by Bryce Younger. 2 Classification ► Electrically powered  microprocessor controlled ► Volume-control, time cycled ► Rotary drive.

Slides:



Advertisements
Similar presentations
72V - Recoil, Recoil IS, & Instinct New Vehicle Delivery Tips
Advertisements

Trouble Shooting (Mechanical Ventilation)
Power Module – Setup Before using the Power Module (PM) to power the HeartMate II or XVE LVAS and optional Display Module or System Monitor, prepare the.
Model 754 Portable Ventilator
In this presentation you will:
Mechanical Ventilation in the Neonate RC 290 CPAP Indications: Refractory Hypoxemia –PaO2 –Many hospitals use 50% as the upper limit before changing.
Introduction to Mechanical Ventilation
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Trigger/Limit/Cycle/Baseline
Register Digital Multimeter Usage Click Register to begin the course.
Startup Training – TPS3 15. Siemens TPS3 Startup Training 2 Topics Covered  Visual Inspections  Verify environmental requirements are met  TPS3 15.
Monitoring with the Vision
Initiating Positive Pressure CMV A generic approach!
EMS Management of the SynCardia Temporary Total Artificial Heart (TAH-t) Patient Clinical-xxx Rev001.
3100B Theory of Operation and Controls. VIASYS Healthcare, Inc. 3100B Theory of Operation and Controls Approved for sale outside the US in 1998 for patients.
pNeuton Transport Ventilator
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Troubleshooting and Problem Solving
Bmd Crossvent 3.
Nesreen El-Sayed Morsy Aly Thoracic Medicine Department
RSPT 2414 Mechanical ventilation Review Unit 3 classifications By Elizabeth Kelley Buzbee AAS, RRT- NPS.
Principles of Mechanical Ventilation
Ventilator.
CMV Mode Workshop.
AHP300 VENTILATOR Prepared by Caesar Rondina, EMTP, SCT, EMTP, CES
How Ventilators Work Chapter 3. To care for a ventilator patient, you need to know: The various functions of the ventilator used How the ventilator interacts.
Newport HT50 Ventilator Orientation & Training
1 Batteries & Battery Clips – Setup for Operation Follow these steps to prepare for battery-powered operation: 1.Place two battery clips, two charged batteries.
Modes and Settings  Tidal Volume ◦ Volume Control ◦ PRVC.
How a Breath is Delivered
Home Care Ventilators. 2 Home Mechanical Ventilators  LP - 6, LP 6+  LP 10 (peds)  PLV-100, 102, 104  Bear 33  LVT-1000  Achieva.
1 Life Products LP-6, LP 6 Plus and LP 10 Home Ventilator By Bryce Younger.
Selecting the Ventilator and the Mode
1 Omni Vent MRI by Bryce Younger by Bryce Younger.
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Ventilators All you need to know is….
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
SureVent 2 - SV2® Gas Powered Automatic Ventilation Resuscitator
Highlights of Unit 3: Classification of mechanical ventilation
ASSISTED VENTILATION By: Dr.Saif Assistant Professor Of Paediatrics Allied Hospital Faisalabad.
Register Digital Multimeter Usage Click Register to begin the course.
Critical Care Ventilation Technology Perspective Fran Hegarty.
3100B Theory of Operation and Controls. SensorMedics 3100B u Electrically powered, electronically controlled piston-diaphragm oscillator u Paw of 5 -
1 Respironics BiPAP-Vision. 2Classification Electrically powered – internal battery powers Vent Inoperative & audible alarms if AC power lost. Error code.
Advanced Modes of CMV RC 270. Pressure Support = mode that supports spontaneous breathing A preset pressure is applied to the airway with each spontaneous.
Basic Concepts in Adult Mechanical Ventilation
Detecting Instruments (For Contest Work Only) MSA Passport Personal Alarm.
BASICS OF WAVEFORM INTERPRETATION Michael Haines, MPH, RRT-NPS, AE-C
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
Mechanical Ventilation Graphical Assessment
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
 Understand the dual control concept  Understand the pressure regulation mechanism in PRVC  Demonstration of PRVC  Settings and adjustment with Servo.
Ventilatory Modes. Volume Controlled Mandatory Breath Gas is delivered at a constant flow until the set tidal volume is reached. Pressure rises to a.
Mechanical Ventilator
NEW 3.0 SOFTWARE FOR SERVO-i AND SERVO-s Servo-i Ventilator
The Crossvent 2i+ option The Crossvent 2i+ is available in 2 different configurations: Model 2200JC Built-in model for retrofitting incubators that currently.
Mechanical Ventilation
PEEP Residual Volume Forced Vital Capacity EPAP Tidal Volume A-a gradient IPAP PaCO2 RR ARDS BIPAP BiPAP NIV PaO2 IBW Plateau Pressure FiO2 A/C SIMV.
Mechanical Ventilation - Introduction
Mechanical Ventilator 2
Mechanical Ventilation
M.C.U..
Advanced Modes of Mechanical Ventilation
Basic Concepts in Adult Mechanical Ventilation
Lamp Error reset Method to solve “Lamp Error” problem
ACOE347 – Data Acquisition and Automation Systems
Transport Ventilator and Beyond!
The peak flows (60 L/min) and flow patterns are the same for all the breaths. The peak flows (60 L/min) and flow patterns are the same for all the breaths.
Presentation transcript:

1 LIFECARE PLV-100 by Bryce Younger

2 Classification ► Electrically powered  microprocessor controlled ► Volume-control, time cycled ► Rotary drive piston ► Modes  Control  A/C  SIMV

3 Modes ► Control ► Assist/Control ► SIMV - machine "looks" for a patient inspiratory effort 6 seconds before the next scheduled mandatory breath. ► Tidal Volume - LED display volume setting ml.

4 Controls ► Rate - LED display set rate BPM. ► I:E Ratio display  Flashes if inverse Ratio is set. ► Flowrate - LED display of flowrate LPM.  Flashes when insufficient. ► Sensitivity  Less or more

5 Controls (cont.) ► Airway Pressure Limit ( cm/H2O)  Vents excess pressure and sounds audible alarm simultaneously. Inspiration ends. ► Flow Rate LED window. ► Power Switch (ON/OFF/RECHARGE)  Internal and external battery will be charged as long as line cord is plugged into wall outlet, regardless of switch position.

6 Alarms ► Low Pressure ( cm/H2O)  Delayed audible alarm activated when proximal airway pressure falls below low pressure alarm setting. ► Green LED lamp lights immediately when proximal airway pressure falls below alarm setting (audible delayed 15 seconds in A/C and SIMV modes. ► In SIMV mode, if proximal airway pressure does not exceed Low Pressure setting during a machine breath, audible alarm activated immediately at the end of the machine breath. Serves as disconnect alarm). ► Apnea Alarm  same as Low Pressure in SIMV during machine breath. ► Power Failure  Audible alarm when "ON" and no power applied.

7 Alarms (cont.) ► Microprocessor Failure  Machine monitored internally and locks motor out if failure conditions sensed. Patient able to breathe through machine.  During ventilator malfunctions (Pressure transducer failure and piston system failure), an audible "fast beep" alarm will sound.

8 ► Low Internal Battery  If voltage of internal battery falls below 9.5 volts, audible alarm sounds and "Internal Battery" lamp will flash on and off. ► Low External Battery  same as for internal battery. "External Battery" lamp will flash on and off. ► Reverse External Battery Connection  If battery leads reversed on external battery connection, an audible alarm will sound (even in OFF position) until the external battery is disconnected. No damage will occur to the unit or external battery. ► Switch to Battery  When power source switches automatically to internal or external battery, a 3 second audible alarm will sound to alert the operator that limited operation time remains. Alarms (cont.)

9 Front Panel ► Increase Inspiratory Flow  Red indicator lamp flashes when set inspiratory flow is insufficient to meet other set parameters. Machine will increase flow over set value and flash red light. ► AC Power Source  Green indicator light ► Internal DC Power Source  Amber indicator light ► External DC Power Source  White indicator light

10 Assist/Spontaneous LEDAssist/Spontaneous LED Green indicator light indicates an assisted breath in A/C mode and indicates spontaneous breaths in SIMV mode. Assisted and Spontaneous breaths will register on the BPM Display.

11 Front Panel (cont.) ► Patient BPM Digital Display –  In Control mode, indicates BPM set.  In Assist/Control mode displays total number of breaths.  In SIMV mode displays total number of machine and spontaneous breaths.  Updated every 4 breaths or whenever rate knob changed. ► I:E Ratio Digital Display - blinks during inverse ratio or readings over 1: 9.99 (Off during SIMV). ► Inspiratory Flow Rate Digital Display - displays peak flows.

12 Tidal Volume Digital Display - displays tidal volume set.Tidal Volume Digital Display - displays tidal volume set. Pressure Gauge - displays pressure at proximal airway.Pressure Gauge - displays pressure at proximal airway.

13 On Start-Up ► Diagnostic Check On Start-Up  When PLV turned on, performs 5 second self check. ► During check ► Digital read 88's ► Vt displays 0.0 (in case of pressure transducer failure, Vt displays 1.0). ► If test detects error, 2.0 will be displayed in Vt display and audible alarm sounds - Do Not Use.