Influence of different representations of the oscillometric index on automatic determination of the systolic and diastolic blood pressures Vojko Jazbinšek,

Slides:



Advertisements
Similar presentations
Institute of Mathematics, Physics and Mechanics University of Ljubljana, Slovenia World Congress Medical Physics and Biomedical Engineering1.
Advertisements

Measurement of CV variables. In vitro Total control of confounding variables –Vasomotion, temperature changes, autoregulation, mean BP Most accurate because.
Monitoring The Emergency Patient ABDULRAHMAN SINDI ( Emergency Medicine Resident)
Blood pressure & Pulse. Blood Pressure The pressure of the blood against the walls of the arteries. Blood pressure results from two forces. ▫One is created.
Blood Pressure Determination
Ακριβής και αξιόπιστη μέτρηση ΑΠ
The association between blood pressure, body composition and birth weight of rural South African children: Ellisras longitudinal study Makinta MJ 1, Monyeki.
Removing the deflation from the recorded NIBP data Fig. 2: a) Filtered pulses (right scale) obtained by band pass ( Hz) filtering and b) Oscillometric.
OSCILLOMETRIC NONINVASIVE BLOOD PRESSURE MEASUREMENTS: THE INFLUENCE OF EXTERNAL ARTIFACTS V. Jazbinsek, J. Luznik, S. Mieke* and Z. Trontelj Institute.
Blood Pressure And BMI. How To Measure Blood Pressure (as given by Oxford Clinical Guide) WIPERS Take name & DOB Ask arm preferences, make sure no tight.
Chapter 5 Part Two Blood Pressure and flow by Ibrhim AlMohimeed BMTS /3/2013.
Section III: Concept 07 Cardiovascular Fitness
Presentation Package for Concepts of Fitness and Wellness 6e Section III: Concept 08 Cardiovascular Fitness All rights reserved.
Blood pressure measurement PHCL 326 (1+1) Clinical skills for pharmacists.
Presentation Package for Concepts of Physical Fitness 12e
Blood Pressure vs. Heart Rate FITNESS AND NUTRITION.
Blood Pressure And BMI. Blood Pressure 3 Questions BEFORE taking BP 1.Caffeine – in last hour 2.Exercise – In last hour 3.Cigarette – in last 30 mins.
Blood pressure. Blood pressure Preparation for measurement.
HEART BEATS, BLOOD PRESSURE, HEART RATE SB1 3C: DECEMBER 2012.
Calibration & Curve Fitting
1. An Overview of the Data Analysis and Probability Standard for School Mathematics? 2.
Chapter 13 Blood Pressure Monitoring. Originates from the heart Value depends on 3 factors: cardiac output diameter of arteries the quantity of blood.
Nieman DC. Exercise Testing and Prescription: A Health-Related Approach. 6/e. Copyright ©2007 McGraw-Hill Higher Education. All rights reserved. Chapter.
Arterial Blood Pressure Taking a person’s Blood Pressure with a sphygmomanometer.
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 63, NO
Time Series Data Analysis - I Yaji Sripada. Dept. of Computing Science, University of Aberdeen2 In this lecture you learn What are Time Series? How to.
Bio212 Laboratory 4 Blood Pressure Heart Sounds Exercise Physiology
2. What is the name of this device used to take blood pressure? 4. What is the name of this device used to listen to blood flow when taking blood pressure?
 Blood pressure means the pressure exerted by blood on the wall of the arteries.  Unit of Measurement-----mmHg  Normal BP  Systolic (100—14ommHg)
RET 1024L Introduction to Respiratory Therapy Lab Module 4.1 Bedside Assessment of the Patient —Vital Signs: Pulse, Respiratory Rate, Blood Pressure, Pulse.
VITAL SIGNS BLOOD PRESSURE PULSE TEMPERATURE RESPIRATIONS.
Electromyography (EMG)
How to Take a Blood Pressure Module 1. Objectives By the end of Module 1, students will be able to: 1.Complete a 1-step method of taking a blood pressure;
2015 Canadian Hypertension Education Program Recommendations
Authors: Noor Mohammed Dr. M.Z. Hossain Dr. Sumon Saha
Introduction (Background) Obesity epidemic in childhood has led to increased emphasis on hypertension and early cardiovascular disease. Ambulatory blood.
Forces acting on blood during circulation
BLOOD PRESSURE MEASUREMENT Sharon Jones Chapter 17.
Blood pressure measurement Presented by -Deepika Jain -Divya Jain
Measuring Blood Pressure. Diagnostic Criteria for HTN Two or more separate occasions – BP > 140/90 –Average of Seated Standing for > 2 min Seated with.
Please get your assigned computer. Do not turn on until instructed.
Measuring Blood Pressure. Diagnostic Criteria for HTN Two or more separate occasions – BP > 140/90 –Average of Seated Standing for > 2 min Seated with.
U.S ARMY HEALTH CARE B/P LAB. 2 SGT Chase Johnson Army Health Care Recruiter U.S Army Medic ( 68W) Emergency Medical Technician (NREMT) Advance Cardiac.
PRESENTED BY : HATIM DINI.  INTRODUCTION  INDIRECT METHOD  GENERAL FACTS  PULPATORY METHOD  AUSCULATORY METHOD  ULTRASOUND METHOD  OSCILLOMETRIC.
Blood Pressure. Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels, and is one of the principal vital signs.
WRITING YOUR MATERIALS AND METHODS! Physiology Lab.
Date of download: 6/27/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Reference Values for Self-recorded Blood Pressure:
Measuring Blood Pressure Blood pressure is indicates your heart health Blood pressure is indicates your heart health It is determined by the contractions.
Noninvasive Blood Pressure Measurement © D. J. McMahon 2014 rev
 Pulse.  Respiratory rate.  Blood pressure.  Temperature.  Pulse oximetry.
Date of download: 9/20/2016 Copyright © The American College of Cardiology. All rights reserved. From: Use of radial artery applanation tonometry and a.
Carditech, California, USA University Of West Bohemia, Czech Republic
Blood Pressure Hypertension Orthostatics
BIOELECTRONICS 1 Lec10: ch4 Blood Measurements By
Noninvasive measurement of blood pressure
Copyright © 2002 American Medical Association. All rights reserved.
REVISED ABSTRACT METHODS CONCLUSIONS
Blood Pressure and Sound (1)
Blood Pressure.
Blood Pressure August 2015 Blood Pressure.
End point Net change with soy supplements vs control (95% CI) p
Blood pressure monitoring during arrhythmia: agreement between automated brachial cuff and intra-arterial measurements  K. Lakhal, S. Ehrmann, M. Martin,
MEDICAL INSTRUMENTATION II BLOOD PRESSURE AND SOUND
Accuracy of feedback-controlled oxygen delivery into a closed anaesthesia circuit for measurement of oxygen consumption†  A.W. Schindler, T.W.L. Scheeren,
Correlation & Regression
Portable Digital Blood Pressure Monitor
Bland–Altman plots; sheath versus cuff.
Blood Pressure Determination
Bureau of Standards, Metrology and Inspection
Presentation transcript:

Influence of different representations of the oscillometric index on automatic determination of the systolic and diastolic blood pressures Vojko Jazbinšek, Janko Lužnik, Zvonko Trontelj Institute of Mathematics, Physics and Mechanics Jadranska 19, 1000 Ljubljana, Slovenia

Introduction Most of automated non-invasive blood pressure – (NIBP) devices use oscillometric technique based on some empirically derived criteria applied to the so-called oscillometric index [1], which is defined as a certain characteristic physical property of the measured arterial pressure pulses. The recorded data in a typical NIBP device contain the arterial pressure pulses in the cuff, superimposed on the cuff deflation. Some NIBP devices have also implanted microphone inside the cuff, which enables measurements of Korotkoff sounds [2], which are otherwise listened by a stethoscope in a conventional BP measurement in the office. In this study we use different physical properties of recorded data to form different representations of oscillometric index. The aim of this study is to find out how these different representations influence on systolic (SP) and diastolic (DP) pressures determined by known algorithms, such as height (HB) and slope based (SB) methods.  1  K-G. Ng, CF.Small. Survey of automated non-invasive blood pressure monitors, Journal of Clinical Engineering; 19: ,  2  N.C. Korotkoff. On the subject of methods of determining blood pressure. Bull. Imperial Mil. Med. Acad. (St. Petersburg), 11: , 1905.

Measurements EU-project “Simulator for NIBP” LODE (Groningen, NL) Compressor for the cuff inflation and a pressure sensor built in a personal computer Upper arm cuff (Accoson, UK) with implanted microphone Simultaneous measurements with commercial automated NIBP device OSZ4 (Welch Alyn)

Measured data – microphone Audible part (Korotkoff) [10-40] Hz Low frequency part [0.3-10] Hz Measured data – pressure Pressure pulses - filter[0.3-40] Hz Time derivative of pressure data Overview of data obtained with NIBP device

Filtered pulses [0.3-40] Hz Time derivative of pressure data Audible part of microphone data NIBP dataOscillometric index Filtered pulses [0.3-40] Hz Time derivative of pressure data Audible part of pressure data

Filtered pulses [0.3-40] Hz Time derivative of pressure data Audible part of pressure data Characterization of oscillometric index Exy

Algorithms for SP and DP Height based (HB) method uses characteristic height ratios (SP , DP – 0.7) Slope based (BS) method uses maximum slope of the curve Non-monotonic curve – constraints in SB method

Evaluation of NIBP devices Two standard protocols for evaluation of NIBP devices: 1.British Hypertension Society (BHS) – at least grade B 2.American Association for the Advancement of Medical Instrumentation (AAMI): Average absolute difference:I∆p| ≤ 5 mm Hg Standard deviation:SD ≤ 8 mm Hg Absolute difference between standard and test device Grade≤ 5 mm Hg≤ 10 mm Hg≤ 15 mm Hg A60 %85 %95 % B50 %75 %90 % C40 %65 %85 % Dotherwise

Evaluation protocol Modified version of AAMI and BHS protocols Similar to BHS protocol, results were classified into grades (6) For every SP and DP, we found classification values V SP and V DP, and calculated combined value V SP+DP (biased to the worse of the V SP and V DP ) Like in AAMI protocol, we calculated I∆p|±SD (average absolute difference). In addition, we have also calculated ∆p ±SD (average difference), linear regression correlation coefficient r, and maximum difference ∆p m

Height based method (HB) - Average height ratios HS xy in HD xy for 92 recordings Filtered pulses [0.3-40] Hz Time derivative of pressure data Audible part of pressure data

Results for height based method (HB) Type of data: a)p – pressure pulses (92 recordings) b) d – derivatives (92 recordings) c) k - Korotkoff (32 recordings) Type of envelope: min-max (p) min-cog (c) cog-max (d)

Tip of data: a) p – pressure pulses SB with constraints (92 recordings) b) p – pressure pulses SB without constraints (92 recordings) c) d - derivative SB with constraints (92 recordings) c) k - Korotkoff SB with constraints (32 meritev) Type of envelope: min-max (p) min-cog (c) cog-max (d)

Summary of evaluation results for SB method Filtered pulses [0.3-40] Hz Filtered pulses without constraints Audible part of pressure data

Summary of evaluation results for HB method Filtered pulses [0.3-40] Hz Time derivative of pressure data Audible part of pressure data

Comparison of HB and SB evaluation results for E pp (peak-to-peak pressure pulses) envelopes HB SB Linear regression Bland-Altman plot

Study of 92 recordings performed on 23 healthy volunteers. Evaluation of two known algorithms, height based (HB) and slope based (SB) methods, applied to different representations of oscillometric index E xy. We used modified combination of standard AAMI in BHS evaluation protocols. We found that HB method can be applied to envelopes that exhibit a rapid change of amplitude near DP and SP. Same behaviour is needed also for SB method, but additional constraints should be applied due to non-monotonic shape of envelopes (especially for SP). For both methods we got best results for oscillometric index formed from peak-to-peak values of pressure pulses. Conclusions