ECOFLOOR TRAINING
HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION: ASL1P MPSV PSV PV ADSV ADPSP MADPSP * 2 x cold connection leads** Only 1 x cold connection lead
HEATING CABLE TYPES ADSV: 1 - DOUBLE-CORD CABLE 2 – FULL SCREEN PROTECTION ( 14 tinned copper wires 0,3 mm + AlPET foil) 3 - FEP INSULATION 4 - PVC JACKET EL.CONNECTION: 1 x 3m COLD CONNECTION LEAD
ADSV USING - RECOMMENDATION DIRECT HEATING (UNDER TILES): WET/NOT WET AREAS (BATHROOMS, KITCHENS, HALLS, ETC..): JUST INDOOR APPLICATION NEW BUILDING RECONSTRUCTION
ADSV STANDARD PRODUCTS 1.HEATING CABLES ADSV / ADSV-T ON DRUMS (SEMI-FINISHED PRODUCTS) 2.HEATING CABLE CIRCUITS (heating cable ADSV with 1connection lead)
ADSV STANDARD PRODUCTS 3.HEATING MATS Double-sided adhesive tape LDTS
ADSV (ADSV-T) STANDARD PRODUCTS HEATING MATS LDTS Packing Mat in carton box
ADSV (ADSV-T) STANDARD PRODUCTS SELF-ADHESIVE MATS LSDTSPacking Mat in carton box
ADSV STANDARD PRODUCTS 4.INSTALLATION SETS ECOFLOOR Cable Kit
ADSV (ADSV-T) STANDARD PRODUCTS INSTALLATION SETS ECOFLOOR Comfort Mat
DIA (mm): 3,6-4,6 MIN. CABLE LOOPS SPACING (mm): 40 MAX.LINEAR POWER (W/m): 18 IN CASE OF SURFACE POWER HIGHER THAN 160W/m2 IS NECESSARY TO SET FOLLOWING MAX.FLOOR PROBE TEMP.(°C): 35 MAX.CABLE JACKET TEMP.(°C): 80 MAX. FIRST CABLE INSULATION TEMP.(°C): 120 ADSV TECHNICAL DATA ADSV
ADSV PRODUCT RANGES ADSV (ADSV-T*) PRODUCTSMARKINGSTANDARD OFFER STANDARD APPLICATION Linear Power W/m Surface Power W/m2 Direct Heating Storage Heating Cable circuitADSV10x ADSV15x ADSV18x X MatLDTS8x-105* LDTS12x-165* X Installation Set E.CableKit E.ComfortMat* , 100 XXXX
Heating cable circuits ADSV INSTALLATION FOR DIRECT FLOOR HEATING ECOFLOOR Packing Variant EHC Box
DIRECT FLOOR HEATING NEW BUILDING RECONSTRUCTION
Prevents heat losses to the sub-floor – recommendation during floor reconstruction! F-BOARD
ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“ 1. Control measuring 2. Grooving for thermostat floor probe 3. Floor base cleaning and penetration 4. Floor probe installation 5. Fixing of el. junction 6. Installation of Heating cable circuit 7. Control measuring8. Thin layer flexible cementing (glueing) 9. New tiling
Heating cable fixing accessories: A. Cable fixing on concrete base floor GRUFAST Fixing strip ADHESIVE TAPE B. Cable fixing on previous tiles floor (Reconstruction)
Measure total area to be heated, then order kit Remember Always keep cable at least 50mm away from wall Use the spacing template provided in the kit to mark out the floor 0.5 m² 4 m².25 m² Bathroom area to be heated is 4.75 m², heated at 160 watts /m² Kit 10 – 750 required (covers 4.7 m²) Total area is: 4.75 m² ECOFLOOR Cable Kit installation
Cut the groove for the floor probe and install the flexible pipe Begin laying the cable taping it to the floor as you go Test the cable for resistance and then cover with tile adhesive Test the cable for resistance once tiling is complete Tile and grout ECOFLOOR Cable Kit installation
Heating mat LDTS INSTALLATION FOR DIRECT FLOOR HEATING ECOFLOOR
LDTS Heating mat (double conductor with 1 connection lead „cold tail“ 1. Control measuring 2. Grooving for thermostat floor probe 3. Floor base cleaning and penetration 4. Floor probe installation 5. Heating mat laying 6. Mat sticking to the floor base by its self- adhesive tape 7. Control measuring 8. Thin layer flexible cementing (glueing) 9. New tiling6. Heating mat installation
ECOFLOOR Comfort Mat
LDTS mat handling
INSTALLATION NOTICE minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm. the heating cable may never be shortened or cutted !!! (only the cold connection lead)
INSTALLATION NOTICE Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm the connector (junction) between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!) the heating cable may never pass over an expansion joint
For floor heating are suitable following thermostats: TH 132-AF Eberle FR-E Eberle Instat 8 TEMPERATURE CONTROLS Fenix Therm 100
16 Amps thermostat connection (thermostat with floor probe) L – phase (el.supply) N – neutral (el.supply) L’ –phase (Ecofloor) N’ – neutral (Ecofloor)
Electrical installation directly throught the thermostat
Electrical installation throught the el.box and contactor (1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)
HEATING CABLE TYPES ADPSP: 1 - DOUBLE-CORD CABLE 2 - FEP INSULATION 4 - FULL SCREEN PROTECTION (PET/AL foil + copper wires) 3 - XLPE INSULATION EL.CONNECTION: 1 x 5m COLD CONNECTION LEAD 5 – PVC jacket (UV protection)
ADPSP USING - RECOMMENDATION REMOVING ICE AND SNOW FROM ROOFS AND GUTTERS AS A PROTECTION OF PIPES AGAINST FREEZING JUST OUTDOOR APPLICATION
ADPSP STANDARD PRODUCTS 1.HEATING CABLES ADPSP (HALF-FINISHED PRODUCTS) 2.HEATING CABLE CIRCUITS (heating cable ADPSP with 1connection lead) ADPSP ECOFLOOR Heating Cable
DIA (mm): 5,0-5,9 MIN. CABLE LOOPS SPACING (mm): 40 MAX.LINEAR POWER (W/m): For roofs and gutters For pipes Technologic heating MAX.CABLE JACKET TEMP.(°C): 80 MAX. FIRST CABLE INSULATION TEMP.(°C): 120 ADPSP TECHNICAL DATA ADPSP
ADPSP PRODUCT OFFER ADPSP PRODUCTSMARKINGSTANDARD OFFER STANDARD APPLICATION Linear Power W/m Surface Power W/m2 Roofs and gutters Protection of pipes Cable circuitADPSP 10x ADPSP 20x X X Mat Installation Set
TEMPERATURE CONTROLS Eberle EM Snow and ice sensor ESD Heat sensor ESD Heating of eaves troughs and gutters Heating of pipes and tubes Eberle ITR-3 UTR/60 sensors
ANOTHER ECOFLOOR APPLICATIONS
INDOOR APPLICATION SEMI-STORAGE AND STORAGE HEATING: WET AREAS (BATHROOMS, LAUNDRIES, ETC..): NOT WET AREAS (KITCHENS, HALLS, LIVING ROOMS, ETC..): PSV PV MPSV MADPSP
OUTDOOR APPLICATION OUTDOOR SURFACE WARMING MPSV MADPSP
SPECIAL APPLICATION GRASS WARMING ON FOOTBALL STADIUM MADPSP
Contact us : FENIX Trading s.r.o. Slezska Jesenik, Czech Rep. Tel/Fax: /303 Web: