RESIDENTIAL FIRE SPRINKLER SYSTEMS

Slides:



Advertisements
Similar presentations
Inspect Water Distribution EO Air Gaps, Vacuum Breaker, and Back Flow Preventers TP 8 50 min.
Advertisements

Plumbing.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Backflow Preventers. Cross Connection Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination.
Proposed Effective Date: January 1, 2009 Based on Plan Received Date OR Based on Installation Date Wisconsin Uniform Plumbing Code.
Water Based Sprinkler Systems 2 major different types of water sprinkler systems Wet pipe system Dry pipe system.
Chapter 20 Plumbing Plans.
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Plumbing Overview WEATHERIZATION INSTALLER/TECHNICIAN FUNDAMENTALS.
The New Low Lead Regulations 2014 AWWA Meeting February 26, 2014 LAURA A. TAYLOR (334)
Wet Pipe Sprinkler System Expansion Chamber Sales Presentation October 2004.
N.F.P.A. 13R Justin Bohlmann FIR-204.
13D Systems What, Why and How Oregon Fire Sprinkler Coalition.
London, 21 May 2014 Alan Brinson A European Residential Sprinkler System Design, Installation and Maintenance Standard.
Residential Fire Sprinklers in the 2010 CA Codes
Water and Fire Protection Issues
Backflow Preventor. (4) The Contractor V may install the cross-connection backflow prevention device as defined in this chapter on new installations.
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
Unit 205: Cold water systems
Piping Materials Plumbing Systems CNST 305 Environmental Systems 1 Dr. Berryman 1bIntroduction – MaterialsChapter 1, 3; Appendix D (Wentz) and
CHAPTER 24 PIPING DRAWING Instructor: M.Yaqub. Chapter 24 piping week# Steel and Wrought Iron Pipe Common use for water, steam, gas and oil. Up.
Skilled Trades 1201 Residential Plumbing.
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
AL/MS AWWA Effective Backflow Prevention August 26, 2013 Sam McElroy, PE Civil Services, LLC (256)
Residential Fire Sprinkler symposium Ontario Convention Center.
Residential Fire Sprinkler Systems. Goal Provide entry level firefighters with an understanding of residential fire sprinkler system Provide entry level.
Automatic Sprinkler Systems
Intermediate SFFMA Objectives: – Hrs received.
Oregon Fire Sprinkler Coalition
Integration of Hydronic Thermal Transport Systems with Fire Suppression Systems ASHRAE Winter Meeting 2001 WALTER M. JANUS, PE URS Corp., Washington, DC.
Hydronic Mechanical Controls
Keeping them Straight October 11,  Piping components come in two categories  Building Piping Components  Underground Piping Components.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Warm-up 4/6/15 What type of water do you have at your house? Objective:
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Domestic Water ®
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Plumbing Plastic Pipe Plumbing Systems 20091Plumbing.
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
1 HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
Residential Fire Sprinkler Concerns. Water Supplier Reliability Issues Water Supply Water Facilities Water Quality Cost.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Residential Construction Unit 5 Energy Efficiencies and Mechanicals Mr. Todzia.
Plumbing Prints Unit 15.
Architectural Graphics UNT in partnership with TEA. Copyright ©. All rights reserved.
HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
Copyright © Texas Education Agency, All rights reserved. Architectural Graphics.
1 CTC 450 Review Water Processes. 2 Objectives Understand the basics with respect to operation of waterworks.
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
CON 4003/CVE 4073/CVE 5073 Construction Estimating Prof R. V. Locurcio.
Plumbing Radiant Heating & Cooling Turf Conditioning Permafrost Ice and Snow Melt Ecoflex ® SupportSustainabilityEngineered PolymerCommercial SystemsIntroductions.
Retrofitting My Home with Fire Sprinklers Greg Kleinberg, Deputy Chief – Fire Marshal Medford Fire-Rescue.
TCEQ Occupational Licensing Licensing Backflow Prevention Assembly Tester (BPAT)Overview Jacquelyn Mills, Occupational Licensing Presentation by Jacque.
Overall overview of Plumbers London. Unlike popular belief, plumbing is an extremely intriguing and varied subject. The wide variety of work involved.
Coachella Valley Water District Water Service and Water Meter Sizing Criteria Workshop April 13th from 10:30-11:30am April 19th from 1:30-2:30pm 1 CVWD.
What is the difference between Annual and Five- year sprinkler test.
CROSS CONNECTION CONTROL PROGRAM
Plumbing system fundamental and design course
Workshop developed by RCAP/AWWA and funded by the USEPA
Cross Connection Survey Training
C&H Fire Suppression Systems Inc Presents
Backflow Prevention and Cross Connection Control Update
CTC 450 Review Water Processes.
Unit 13 Plumbing Prints. Unit 13 Plumbing Prints.
RESIDENTIAL PLUMBING SYSTEMS (WATER SUPPLY)
AUTOMATIC SPRINKLERS.
Electrical Gas Plumbing Heating & Cooling
PLUMBING PLANS CHAPTER 31
See for Yourself! What’s in Your Water?
NFIRS 3 Structure Fire Module
Backflow Devices 5 Types.
Presentation transcript:

RESIDENTIAL FIRE SPRINKLER SYSTEMS

CRC R313 Automatic Fire Sprinklers shall be installed in Townhouses and SFD & duplexes Exception: additions & alterations to existing without sprinklers Applies to “Stand-alone” and “Multipurpose” Only “wet” systems (13D-Dry system) No anti-freeze (13D-Anti-freeze-Propylene Glycol- problems; max 40%)

SPRINKLER SYSTEM TYPES-1 NFPA 13 Closed systems (check valve-alarm-FD Connection) Anti-freeze Dry systems Typically, backflow protection is required DC or RP (depending on the type of hazard) Detectors – DC or RP

TYPES OF HAZARD Contamination-High Hazard Pollution-Low Hazard

SPRINKLER SYSTEM TYPES-2 NFPA 13D Stand-Alone vs. Multi-purpose

Stand-Alone (Domestic bypass) “Tyco Valve” Garage Water Main Meter SOV To Spr. in attic Meter SOV Drain To Domestic Bathroom Bathroom Stand-Alone

Multi-Purpose KS, DW, CW WH HB BT, L, WC Each Bathroom Could be used As a drain HB BT, L, WC Each Bathroom Multi-Purpose

BACKFLOW PROTECTION Public Water System vs. potable water within the building UPC CPC NFPA 13 NFPA 13D Task Force

UPC

UPC

CPC

ISSUES OF CONCERN Pipe/tubing material Iron, Copper, CPVC, PEX Flushing requirements (Section 609.9 CPC for all) Flushing requirements CPVC (Section 604.1 CPC) Flushing requirements PEX (Section 604.1.2 CPC)

2006

IS-20-2006 1.2 Special Requirements for CPVC Installation within Residential Structures. [HCD 1] In addition to the other requirements in the California Plumbing Code and this Appendix for the installation of CPVC Solvent Cemented Hot and Cold Water Distributions Systems, all installations of CPVC pipe within residential structures shall meet the following: 1.2.1 Flushing Procedures. All installations of CPVC pipe within residential structures shall be flushed twice over a period of at least one (1) week. The pipe system shall be first flushed for at least 10 minutes and then filled and allowed to stand for no less than 1 week, after which all the branches of the pipe system must be flushed long enough to fully empty the contained volume. At the time of fill, each fixture shall have a removable tag applied stating: “This new plumbing system was first filled on (date) by (name). The California Department of Housing and Community Development requires that the system be flushed after standing at least one week after the fill date specified above. If the system is used earlier than one week after the fill date, the water must be allowed to run for at least two minutes prior to use for human consumption. This tag may not be removed prior to flushing, except by the homeowner.”

ISSUES OF CONCERN

ISSUES OF CONCERN Dead end? Connect to a frequently used fixture (WC) close to end of line