OME Photo & Graphics Group Optical Qualities of the Boston Keratoprosthesis Rony R. Sayegh †1, Linda Avena Diaz 1, Fernando Vargas-Martín 2, Robert H.

Slides:



Advertisements
Similar presentations
Evaluation of Higher Order Aberrations in Eyes with Dohlman/Boston Keratoprosthesis and Comparison with Penetrating Keratoplasty and Normal Eyes K.Stasi.
Advertisements

Introduction to Eye Tracking
Lesson Objectives Explain how light travels Explain how we see objects Know how shadows are formed.
Lens  The lens is the most important part of the camera  Lens captures light and focuses the light on the part of the camera that receives the image.
LIGHT AND THE RETINAL IMAGE: KEY POINTS Light travels in (more or less) straight lines: the pinhole camera’s inverted image Enlarging the pinhole leads.
Earth in Yellow Flower Presenter Name By PresenterMedia.comPresenterMedia.com By Sumitra Marda Optometrist, Ocularist, Low vision specialist, Sportvision.
Glaucoma Presented by: Angela Garcia Denniqua Holloway Maria Pimentel
Visual outcome & subjective visual symptoms of the Tecnis ZM900 multifocal intraocular lens in Asian eyes Dr Colin S.H. Tan MBBS, MMed (Ophth), FRCSEd.
Web Address A New Option for Keratoconus How INTACS Treat Keratoconus Addition Technology, Inc.
Supplies: Print: 10 Demo:.
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
Vision Our most dominant sense
Presented by Jessica M. Borges Certified Ophthalmic Technician-JCAHPO HOW DO WE SEE?
Human Image Formation What is the quality of the optics of the human eye? How can we measure it and describe it empirically?
1 THE EYE Bushong Ch. 29 p Appendix #1 State Fluoro Syllabus pg 77 Reference: Ch. 14 Carltons.
Sensation Chapter 5 Myers AP Psychology. Transduction  Conversion of one form of energy into another.  In sensation, the transforming of stimulus energies,
Understanding Disparities Among Diagnostic Technologies in Glaucoma De Moraes C, Liebmann JM, Ritch R, Hood DC. Understanding disparities among diagnostic.
Wavefront Sensing of the Human Eye
Human Eye  A human eyeball is like a simple camera! Sclera: White part of the eye, outer walls, hard, like a light-tight box. Cornea and crystalline lens.
The Visual System: The Structure of the Visual System Module 9: Sensation.
Vision – our most dominant sense. Vision Purpose of the visual system –transform light energy into an electro-chemical neural response –represent characteristics.
Bausch & Lomb 217A Excimer Laser Overview Why It Is Unmatched!
Learn about users: Aging: Changes in visual function Gaël Vasseur Tokyo Institute of Technology Graduate school of Information Science and Engineering.
Human Vision. The pupil is the dark transparent region in the centre of the eye where light enters. The iris is the coloured circle of muscle surrounding.
(c) McGraw Hill Ryerson Human Vision The pupil is the dark transparent region in the centre of the eye where light enters. The iris is the coloured.
Optical Properties and Fundus Imaging Through a PMMA Keratoprosthesis
Purpose  To analyze, through theoretical and experimental methods, the relative luminescence of a series of images produced by multiple reflections in.
Anatomy of the Eye.
3.2 VISION 70% of your receptor cells are in your eyes taste and touch need direct contact where as sight and smell don’t Sight can be experienced from.
Unilateral multifocal lens implantation in patients with a contralateral monofocal or phakic eye is a viable presbyopic correction option Robert J. Cionni,
Austin Roorda, Ph.D. University of Houston College of Optometry
Normal Vision: Age is in the Eye of the Beholder.
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
Short Term Visual Outcomes Boston Keratoprosthesis Type I
AlphaCor TM : A Novel Approach to Minimize Late Post-operative Complications V. Ngakeng MD, M. Price PhD. MBA, F. Price MD.
(c) McGraw Hill Ryerson Human Vision The pupil is the dark transparent region in the centre of the eye where light enters. The iris is the coloured.
I. Trace evidence=  Physical evidence found at a crime scene in small but measurable amounts  Examples: hair, glass, fibers, paint, pollen, gunshot.
The Visual System: The Structure of the Visual System Module 9: Sensation.
AcrySof ® ReSTOR ® Aspheric IOL. Aspheric IOL AcrySof ® ReSTOR ® 2 AcrySof ® ReSTOR ® Aspheric IOL SN6AD3 Add Power: +4 D Spectacle Plane: 3.2 D Range:
On the Evaluation of Optical Performace of Observing Instruments Y. Suematsu (National Astronomical Observatory of Japan) ABSTRACT: It is useful to represent.
Ophthalmology & Vision Sciences
Dispersion.
Senses Lab: Sight How do our eyes work? Why do they work this way?
Coordination and Response in Plants and Animals
Construction of Human Eye –iris, pupil, cornea, aqueous humour, lens, ciliary muscle, vitreous humour, retina Focusing –seeing near object ( near point.
Structure of Human Eye: –Eye Muscles, Optic nerve, sclerotic coat –Cornea, iris, pupil,, lens, retina, blind spot –aqueous humour, vitreous humour, ciliary.
The Visual System: The Structure of the Visual System.
The authors have no conflicting interest in the subject matter of this poster. In Vivo Evaluation of DSAEK Interface with Scanning- Laser Confocal Microscopy.
Cost-Effectiveness of the Type II Boston Keratoprosthesis Jared D. Ament, MD, MPH, Tomasz P. Stryjewski, BS, Siddharth Pujari, PhD, George Papaliodus,
Date of download: 5/30/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Quantitative Performance of Bifocal and Multifocal.
Vision Our most dominant sense. Our Essential Questions What are the major parts of the eye? How does the eye translate light into neural impulses?
Mirrors and Lenses How do eyeglasses correct your vision? When you look in a mirror, where is the face you see? In which ways is a cell phone camera similar.
CATz for Highly Irregular Corneas after Keratorefractive Surgery Hamed M. Anwar, MD, FRCS Alaa El-Danasoury, MD, FRCS 1 Institutional affiliation: Magrabi.
The Visual System: The Structure of the Visual System Module 9: Sensation.
6.1 Human Vision.  Light enters the eye through the pupil  The iris (the coloured part of the eye) controls the amount of light entering the eye  In.
The iris is the coloured circle of muscle surrounding the pupil.
The Visual System: The Structure of the Visual System
Light and Optics 18.1 Mirrors form images by reflecting light. 18.2
THE EYE The eye is an amazing and important part of the body. Eyes allow us to see the shape, size, colour, and depth of the world around us. Of all the.
The iris is the coloured circle of muscle surrounding the pupil.
The iris is the coloured circle of muscle surrounding the pupil.
THE EYE.
The Eye as a Camera Michael A. Sandberg, Ph.D.
The iris is the coloured circle of muscle surrounding the pupil.
Human Eye Structure of Human Eye: Focusing Eye defects
Optics 14.1 Light tends to travel in straight lines. 14.2
Chapter 6.1 Human Vision.
Vocab Terms Section #2.
Presentation transcript:

OME Photo & Graphics Group Optical Qualities of the Boston Keratoprosthesis Rony R. Sayegh †1, Linda Avena Diaz 1, Fernando Vargas-Martín 2, Robert H. Webb 2, Claes H. Dohlman 1, Eli Peli 2 Optical Qualities of the Boston Keratoprosthesis Rony R. Sayegh †1, Linda Avena Diaz 1, Fernando Vargas-Martín 2, Robert H. Webb 2, Claes H. Dohlman 1, Eli Peli 2 Better understanding of the visual function with the Keratoprosthesis (KPro) may lead to design and practice modifications that could further improved outcomes. Here we addressed: (1) the effect, sources, and control of glare (2) the binocular vision benefits of implanting a KPro in a patient with a fellow healthy eye Optical Analysis Zemax (Focus Software Inc, San Diego, CA) was used to derive theoretical optical parameters of the KPro: Visual fields, point spread function (PSF), spot diagrams, and sources of glare. Artificial Eye An optical bench setup was used to assess of the optical quality and the effect of glare on the retinal image. To test for the role of the hazy cornea, the KPro was inserted into a finely sand-blasted Boston scleral lens. 1 Massachusetts Eye & Ear Infirmary, Boston, MA. 2 The Schepens Eye Research Institute, Boston, MA. † Correspondance: ♦Our experiments indicate that the hazy cornea surrounding the implant is a major source of glare in KPro implanted eyes. ♦Glare was virtually eliminated when the KPro was implanted into an opaque iris in the artificial eye. ♦The tinted soft lens did reduce glare but not to the same extent. This is attributed to the larger diameter of the CL pupil. ♦In patients, the use of the same CL resulted in an improvement in visual acuity of about 38%. Type II KPro patients, with lid tissue around the nub, were even less sensitive to increasing glare. ♦The beneficial effect of a painted CL could potentially be mimicked by keeping as much of the natural iris intact during the surgery. ♦Visual fields in KPros are dependent on the diameter and length of the optical cylinder. In the case of the Boston KPro, these were found to be around 95° and 90° wide for Types I and II respectively, providing patients good peripheral vision. However the binocular field is not significantly improved for patients with intact fellow eye ♦Little benefit to stereo vision seemed to be derived from implanting a KPro in the presence of an undiseased contralateral eye with conserved vision. ♦The latter 2 points may advice against KPro for patient with intact fellow eye In the artificial eye optical bench setup with Type 1 KPro installed in a metal iris an image of a distant point-source was consistent with the computed high quality optics. A soft Kontur CL with an opaque (1% transmissive) iris placed on top of the scleral lens-KPro construct decreased the size of the surrounding scatter halo; however, it was not completely eliminated. A halo of scattered light surrounding the central projection of the bright point source was observed in the artificial eye with the sand blasted simulated cornea, which could be eliminated by decreasing the aperture of the iris down to a 3-mm pupil. Stereoscopic Exam Stereo acuity and eye preference was evaluated for 3 patients with intact contralateral eye. In all, vision was better in the non-KPro-implanted eye (by 1 to 4 lines). The fellow eye was found do be dominant. Stereopsis at 16 inches ranged from seconds of arc, reflecting minimal stereoscopic ability. Additional tests Goldmann kinetic perimetry (V4e). Stereo acuity measured in patients with intact fellow eye (Wirt Stereo Fly Test, Stereo Optical Co., Chicago, IL). Suppression was evaluated using the suppression test provided in the Fly test. RESULTS Computed modulation transfer function (MTF) and point spread function (PSF) show that the system was close to diffraction-limited. Glare sensitivity Glare sensitivity was measured with a Mentor BAT (Mentor O&O, Inc, Norwell, MA). Measurements were obtained with: (1) a standard transparent contact lens (CL) in place (2) a dark iris CL, 4-mm pupil (Kontur Kontact Lens, Richmond, CA) INTRODUCTION: METHODS : RESULTS: Evaluation of glare effects Zemax computation of glare from reflections off the many surfaces was minimal, even when assuming all surfaces to be 100% reflecting limit field 60 deg The use of the opaque soft CL resulted in significant gain in measured visual acuity of approximately 3 lines under high glare setting (p = 0.01). Visual Fields The Zemax model shows a maximal visual field diameter of approximately 120 degrees for the type I KPro. Consistent results were obtained using Goldman perimetry. The fields for the Type I were about 90 degrees in diameter and for the type II about 80 □ Average change in acuity of 8 pts with type I KPro; ■ The same 8 pts while wearing the iris-painted CL; ∆ Change in acuity for2pts with type II KPro NB: The pt with no loss of acuity due to glare ( ▲ ) is African American. The other was Asian degrees. Type I (Lt) & Type II (Rt) superimposed on normal fields CONCLUSIONS: AFFILIATIONS: SUPPORT: EP and FVM were supported in part by NIH grants EY05957 and EY12890