And a head sensor on a sun tracker What is PANDORA? Pandora is a small spectrometer system, which we have been developing since 2006. It consists of …

Slides:



Advertisements
Similar presentations
Digital Camera Essential Elements Part 1 Sept
Advertisements

Validation of SCIAMACHY using POLDER as a reference 25 April 2006.
And a head sensor on a sun tracker What is PANDORA? Pandora is a small spectrometer system, which we have been developing since We now have over.
Optical Astronomy Imaging Chain: Telescopes & CCDs.
SWD 2005, Taormina, Jun,19-26 An EUV Imaging Detector of Space Solar Telescope Qian Song, Binxun Ye, Zhaowang Zhao National Astronomical Observatories,
7. Beer’s Law and It’s Implications for Instrument Construction.
PASCO scientific: Solid State Spectroscopy with SPARK Tom Loschiavo Chemistry Education manager.
1 Estimate on SOT light level in flight with throughput measurements in SOT sun tests T. Shimizu 1, T. Tarbell 2, T. Berger 2, Y. Suematsu 3, M. Kubo 1,
1 Estimate on SOT light level in flight with throughput measurements in SOT sun tests T. Shimizu 1, T. Tarbell 2, Y. Suematsu 3, M. Kubo 1, K. Ichimoto.
Chapter 26 Properties of Light. Origin and Nature of Light Light originates with accelerated motion of electrons. It is an electromagnetic wave phenomenon.
OL 750 Measurement Systems
Spectrophotometer Jan 28, 2002 Deryck Hong Suryadi Gunawan.
1Yang LiuCISM All-hand meeting CISM All-hand Meeting Yang Liu – Stanford University
Modeling the imaging system Why? If a customer gives you specification of what they wish to see, in what environment the system should perform, you as.
Object Detection Procedure CAMERA SOFTWARE LABVIEW IMAGE PROCESSING ALGORITHMS MOTOR CONTROLLERS TCP/IP
Source lens Entrance slit Exit slit width,  (mm) grating Concave mirrors Focal Plane Focal Length, F (mm)
... M A K E S Y O U R N E T W O R K S M A R T E R Lenses & Filters.
Rachel Klima (on behalf of the MASCS team) JHU/APL MASCS/VIRS Data Users’ Workshop LPSC 2014, The Woodlands, TX March 17,2014 MASCS Instrument & VIRS Calibration.
Berkeley workshop summary Redundancy : dual detector Field of view : 3”x6” Spectrograph length goal: < 400 mm Isostatic mount on the base plate with control.
Agile: A Time-Series CCD Photometer to Study Variables Anjum Mukadam, Russell Owen, Ed Mannery University of Washington, Seattle.
CINDI Workshop, BIRA, Brussels, Pandora Direct Sun Data during CINDI Alexander Cede Nader Abuhassan Jay Herman.
BRITE-Constellation consists of six nano-satellites: UniBRITE and BRITE-AUSTRIA (TUGSAT-1) are funded by Austria, two more by.
SALT Technology Development Lisa Crause India-South Africa Astronomy Workshop – SAAO 6 August 2012.
New Improved Eyes Telescopes and “Invisible” Astronomy.
BRITE-Constellation currently consists of two satellites, UniBRITE and BRITE-AUSTRIA (TUGSAT-1) and two satellites to be funded by the Canadian Space Agency.
NASA Ames: P. Russell, J. Redemann, S. Dunagan, R. Johnson, J. Zavaleta PNNL: B. Schmid, C. Flynn, E. Kassianov NASA GSFC: AERONET Team A collaboration.
Photography in Education TECH2113 Dr. Alaa Sadik Department of Instructional & Learning Technologies
YunNan One Meter Infrared Solar Tower Jun Lin. Why is YNST? After Solar-B launch, what can we do by using of ground-based telescope ? Detailed chromosphere.
Near Infrared Spectro-polarimeter (NIRSP) Conceptual Design Don Mickey Jeff Kuhn Haosheng Lin.
October 29-30, 2001MEIDEX - Crew Tutorial - Calibration F - 1 MEIDEX – Crew Tutorial Calibration of IMC-201 Adam D. Devir, MEIDEX Payload Manager.
VI-5475(SamCalValNotes) 1 SAM (Sun and Aureole Measurement) Calibration Prepared for MODIS/VIIRS Science Team Meeting Dennis Villanucci, Andrew LePage.
Astronomical Spectroscopy Notes from Richard Gray, Appalachian State, and D. J. Schroeder 1974 in “Methods of Experimental Physics, Vol. 12-Part A Optical.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
1 An Observatory for Ocean, Climate and Environment SAC-D/Aquarius HSC - Radiometric Calibration H Raimondo M Marenchino 7th SAC-D Aquarius Science Meeting.
 Introduction  Surface Albedo  Albedo on different surfaces  Seasonal change in albedo  Aerosol radiative forcing  Spectrometer (measure the surface.
June 6-13, 2009 Sunrise Balloon Flight Studying the Sun with Milli-arcsecond Pointing.
LSST Studies Large Synoptic Survey Telescope DOE HEP Program Review April 18, 2006 Brookhaven National Laboratory Morgan May.
September 16, 2008LSST Camera F2F1 Camera Calibration Optical Configurations and Calculations Keith Bechtol Andy Scacco Allesandro Sonnenfeld.
Field Test Photos Nikon D80 and Krimesite Imager Establishing shot of shelf identified with Krimesite canvass as area of interest. f/3.3, 1/60 sec, 28mm,
Telescopes The instruments we use to study the universe.
MIRI Dither Patterns Christine H Chen. Dithering Goals 1.Mitigate the effect of bad pixels 2.Obtain sub-pixel sampling 3.Self-calibrate data if changing.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Audio and Video Productions Room 706. ISO Determines sensitivity of image sensor to light.
Unit 57 – Photography Lenses. Lenses of different focal lengths allow photographers to have more creative control 1.Standard lens 2.Wide-angle lens 3.Telephoto.
Science with Giant Telescopes - Jun 15-18, Instrument Concepts InstrumentFunction range (microns) ResolutionFOV GMACSOptical Multi-Object Spectrometer.
No Blur in the Image Sensor Consistent light. Motion Blur in the Image Sensor Inconsistent light.
Charts for TPF-C workshop SNR for Nulling Coronagraph and Post Coron WFS M. Shao 9/28/06.
There are four main functions of the lens…. The first and most obvious is…
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
INTEGRATION OF IFE BEAMLET ALIGNMENT, TARGET TRACKING AND BEAM STEERING Graham Flint March 3, 2005.
ISUAL Design Concept S. Mende. SDR 7 Jun NCKU UCB Tohoku ISUAL Design Concept S. Mende Sprite Example Sprite Image obtained by Berkeley/NCKU 1999.
F. Pepe Observatoire de Genève Optical astronomical spectroscopy at the VLT (Part 2)
아이알브이테크 1 IRV-TECH 아이알브이테크 May 12, 2015 IRV-65B Light Source.
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
ACD Airborne FTS Spectrometer History Acquired in 1974 for measurements of stratospheric composition Flown hours on NCAR Sabreliner.
Lens sizes Depth of Field
Ultra-Violet Imaging Telescope for ASTROSAT
Onboard Instruments of ASTROSAT
A.S. Ghalumyan, V.T. Nikoghosyan Yerevan Physics Institute, Armenia
An IFU slicer spectrometer for SNAP
Mini- and Micro-spectrometer Pixel/Wavelength Calibration
The Successor of the TOU
IMPALAS Fabry-Perot System
Overview Instrument Role Science Niches Consortium science
Depth Of Field (DOF).
Diurnal Variation of Nitrogen Dioxide
Shanghai Institute of Technical Physics , Chinese Academy of Science
Ozone Comparison between Pandora #34, the Dobson #061, OMI, and OMPS at Boulder Colorado for the period December 2013 – June J. Herman, R Evans,
Optics Alan Title, HMI-LMSAL Lead,
Hyperspectral Terminology
Presentation transcript:

and a head sensor on a sun tracker What is PANDORA? Pandora is a small spectrometer system, which we have been developing since It consists of … a “miniature” spectrometer Measures sun and sky radiance from 270 to 530 nm in 0.5 nm steps with a 1.6 o field of view. Products: NO 2, H 2 O, O 3, SO 2, HCHO, and aerosol properties with 1% accuracy and 0.1% precision.

PANDORA Specifications - Sun spectrometer, 75mm focal length symmetrical Czerny-Turner - Uses Hamamatsu image sensor (CCD 2048x16 array) - Wavelength range: 270nm to 530nm, resolution ~0.5nm - Field of view ~1.8° full angle - Two filterwheels with opaque for dark count, short-pass filters to reduce stray light. - S/N: ~400:1 for single shot at 400nm  >10,000 for 20sec average - Regular measurement mode: Every minute 20 seconds averaged measurement with each filter + dark counts - Open, UV-340, ND-1, ND-2, ND-3, Opaque Head Sensor

What Does Pandora Measure Open Hole UV340 BP300