Elliot Mylott, Ryan Klepetka, Justin C. Dunlap and Ralf Widenhorn

Slides:



Advertisements
Similar presentations
Computed Tomography Principles
Advertisements

Image Reconstruction.
Teaching Laboratories featuring Medical Physics Suzanne Amador Kane, Associate Professor of Physics Justin Cantley, Depts. Physics & Astronomy Haverford.
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Computed Tomography II
P 251 Laboratory Activity III Graphical Analysis II Nonlinear Graphs.
CT Physics V.G.Wimalasena Principal School of radiography.
Computed Tomography III
Measurement of Light: Applications ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
Intelligent Systems Lab. Extrinsic Self Calibration of a Camera and a 3D Laser Range Finder from Natural Scenes Davide Scaramuzza, Ahad Harati, and Roland.
Imaging Systems X-Rays. Imaging Systems: Shared Elements 1.Where did the energy come from? 2.What happens when the energy interacts with matter? 3.How.
Computed Tomography RAD309
An algorithm for metal streaking artifact reduction in cone beam CT M. Bazalova 1,2, G. Landry 1, L. Beaulieu 3, F. Verhaegen 1,4 1-McGill University,
tomos = slice, graphein = to write
Applications of SPCE to Pharmaceutical Research Kathleen Hamilton, Tom Laue, and James Harper Presentation at the 2007 BITC Meeting University of New Hampshire.
Chapter 2 Stewart C. Bushong
CSC 461: Lecture 2 1 CSC461 Lecture 2: Image Formation Objectives Fundamental imaging notions Fundamental imaging notions Physical basis for image formation.
Computed Tomography
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Conventional and Computed Tomography
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
COMPUTED TOMOGRAPHY (I) RAD 365 CT - Scan
Basic principles Geometry and historical development
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Alhanouf Alshedi CT Physics and Instrumentation RAD
Interfacing Physics Sensors Using National Instruments Educational Laboratory Virtual Instrumentation Suite & LabVIEW by Eric Ethridge Left to right: motion.
Technology and digital images. Objectives Describe how the characteristics and behaviors of white light allow us to see colored objects. Describe the.
Computed Tomography Physics, Instrumentation, and Imaging
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Evaluation of the Performance of the Fast Scanning Platform of an OCT System Malcolm Heard 1, Miguel Herrera 1, Geoffrey Ibbott 1 1 Department of Radiation.
Light Chapter 16.
Ch23 Geometric Optics Reflection & Refraction of Light.
An experiment in computed tomography
Integral University EC-024 Digital Image Processing.
Filtered Backprojection. Radon Transformation Radon transform in 2-D. Named after the Austrian mathematician Johann Radon RT is the integral transform.
Medical Image Analysis Image Reconstruction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
LOGO ภาควิชาอิเล็กทรอนิกส์ คณะวิศวกรรมศาสตร์ สถาบันเทคโนโลยีพระจอมเกล้าเจ้าคุณทหารลาดกระบัง.
Interaction ionizing radiation with biological tissue. Basic dosimetry.
Technical development of a high resolution CCD-based scanner for 3-D gel dosimetry: (I) Scanner construction S J Doran, K K Koerkamp*, M A Bero, P Jenneson,
: Chapter 11: Three Dimensional Image Processing 1 Montri Karnjanadecha ac.th/~montri Image.
Principles and Practice of Radiation Therapy
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
CT IMAGE RECONSTRUCTION  Hounsfield envisioned dividing a slice into a matrix of 3-dimensional rectangular boxes (voxels) of material (tissue). Conventionally,
THE PRINT-SCAN Machine 3-D Spatial Mapping Device Nia Cook Stephen Tan Anil Rohatgi Senior Design Final Report Presentation ECE4006 Spring2005.
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
Single-Slice Rebinning Method for Helical Cone-Beam CT
CT Chapter 4: Principles of Computed Tomography. Radiography vs. CT Both based on differential attenuation of x-rays passing through body Radiography.
Observing Transfer Functions For Multimode Spectrometers.
To move or not to move: A Medical Imaging Perspective Debasis Mitra & Daniel Eiland Thomas Welsh Antall Fernanades Mahmoud Abdalah Department.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Physical Optics 1 st year physics laboratories University of Ottawa Winter
Colours – Learning Outcomes  Associate the wavelength of light with its colour.  Describe the electromagnetic spectrum in terms of frequency and wavelength.
Computed Tomography The images in the following presentation follow the “fair use” rules of the U.S. Copyright law.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Single Slice Spiral - Helical CT
-42 Impact of signal non-repeatability on spectral CT images
CT Multi-Slice CT.
Computed Tomography Data Acquisition
Learning Objectives By the end of this lesson you should…
Modern imaging techniques in biology
Vysakh Vasudevan*, N. Sujatha
5.2 Properties of Light Our goals for learning What is light?
Computed Tomography (C.T)
Presentation transcript:

Medical imaging with a photogate: an activity for high school and college students Elliot Mylott, Ryan Klepetka, Justin C. Dunlap and Ralf Widenhorn Physics Department, Portland State University, Portland, OR Operation Abstract Artifacts and Windowing When the photogate becomes blocked, the program… calculates the equation of the line between the source and detector of the photogate enters the projection data along that original line The inputs of the program are the distance between the rotational axis and the origin, also called the focus-center distance (FCD) the angle between the FCD line and the negative x-axis q the angle between the FCD line and the scanning line f Image artifacts: Caused by either the reconstruction algorithm or the scanning technique Can be incorporated into the laboratory session as they are important considerations in medical scanners as well The most common artifacts are… Unwanted data that does not correlate to either the cylinders or the enclosure “Blurring” (amplitude on reconstruction proportional to 1/r) “Afterglow” (misplaced data caused by short scan times) We present a laboratory activity in computed tomography (CT) primarily composed of a photogate and a rotary motion sensor that can be assembled quickly and partially automates data collection and analysis. We use an enclosure made with a light filter that is largely opaque in the visible spectrum but mostly transparent to the near IR light of the photogate (880nm) to scan objects hidden from the human eye. This experiment effectively conveys how an image is formed during a CT scan and highlights the important physical and imaging concepts behind CT such as electromagnetic radiation, the interaction of light and matter, image artifacts and windowing. CT and Back Projection Reconstruction Program Windowing Emphasizes differences in attenuation characteristics Done by adjusting the relative values of the gray scale Figure 8 shows the same data as figure 6 after applying a window. Note that the lower boundary of the grey scale is higher than that in figure 6, which obscures the unwanted data. Figure 3. CT geometry X-rays from the source are attenuated by objects in the scanned area, which is recorded as projection data That data is spread back onto a reconstruction of the scanned area This process is completed multiple times as the source/detector assembly rotates about the scanned area After multiple back projections an image of the original object(s) forms. Complete Scan Figure 8. The same data from figure 6 after applying a window. Figure 5. Positions of three cylinders in the enclosure (0.6 cm in diameter) References Figure 1. Basic reconstruction technique of CT [1] Buzug T M 2008 Computed Tomography: From Photon Statistics to Modern Cone-Beam CT (Berlin: Springer) pp 2, 201, 207, 485, 85,437 [2] Delaney C and Rodriguez J 2002 A simple medical physics experiment based on a laser pointer Am.J. Phys. 70 1068-70 [3] Murphy, S 2010 Basic Apparatus for CT Analogy, 2010 March 5, http://web.phys.ksu.edu/mmmm/instructor/. [4] Wolbarst, AB 2005 Physics of Radiology (Madison, WI: Medical Physics Publishing) p 409 [5] Kane SA 2003 Introduction to Physics in Modern Medicine (Abingdon, UK: Taylor & Francis) pp 189-195 Apparatus Principal components were Vernier photogate and rotary motion sensor Instead of X-rays, we used a near IR light source to simulate a CT scanner The enclosure is a Congo Blue light filter, which is largely opaque in the visible spectrum but mostly transparent to the near IR photogate light. Figure 4. LabVIEW user interfaces (manual and simulated) Figure 6. Final image of cylinders in figure 4 (36 scans, 20 min scan time) Figure 7. Scans of the cylinders as shown in figure 5 taken in 10o increments over q =150o Conclusion The LabVIEW program… Collects and displays data in real time Forms image step by step (figure 7). Comes with a simulated CT scanner that uses the same algorithm Quick scans of multiple combinations of object sizes and positions. Explores the effects of the three parameters (FCD, f and q) on the final image An effective graphical demonstration of how back projection forms an image. The images in figure 6 and 7 are of three identical cylinders, each with a diameter of 0.6 cm, placed in the enclosure as shown in figure 5. The large ring around the cylinders in the images is the opaque enclosure which reflects the light from the photogate at shallow angles effectively “blocking” it. The time needed to complete a full scan is dependent on… The number of passes (each having a unique q) The rotational speed of the photogate The resolution of the reconstruction. We have constructed a simple, safe apparatus that effectively demonstrates the basic mechanism and concepts behind CT scans. It is comprised of a photogate, rotary motion sensor, and other equipment commonly found in most physics teaching labs. The setup can be completed in minutes and scan times are short enough that multiple objects can be imaged in a single session. The activity is appropriate for high school and college level physics or biology courses. This activity gives students a chance to learn about trigonometry, electromagnetic radiation, radiographic imaging, image analysis and windowing. Figure 2. CT apparatus and light filter