Battery Watering Technologies

Slides:



Advertisements
Similar presentations
Getting Started with the EELD601 After you remove your EELD601 from the box, check to make sure you have all accessories shown below. Click here for next.
Advertisements

Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
ADX 150 – Engine Repair ADX 170 – Climate Controls
Unit 206: Domestic hot water systems
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
CV2000LS – Post Compensated Valve CV2000LS Post Pressure Compensated Flow Sharing Valve.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Installation. Indoor Unit Installation Typical Installation.
Introducing The Blokker
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
KOREA KIYON COMPANY PROFILE. COMPANY PROFILE Korea Kiyon Company, established in 1985, with the highest quality and most technology advanced inert atmosphere.
Inventory Kanbans Automating the Replenishment Cycle
Expect More. World’s leader in pressure technology NA Sales Training Rev B – 10/10/13.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
MSE507 Lean Manufacturing
2.5.6 Student Book © 2004 Propane Education & Research CouncilPage Operating a Propane Dispenser to Fill Vehicle-Mounted ASME Tanks To safely and.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
Automotive Batteries.
STEAM HEATING.
Hydronic Mechanical Controls
A/C testing and service. Before testing and service, technician must be certified by ASE, MACS, or IMACA.
Water Supply.
Lockout Tagout Tryout (LOTO). The purpose of the Lockout Tagout Program is to protect you. Rain for Rent incidents include employees being sprayed with.
D-M-E Hot Runner Solutions D-M-E Hot Runner Capabilities.
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
Optimizing your handpiece life! By The Dentist’s Choice.
In this module you will learn to:
Quality Steel Products :: ADVANTAGES  Plastic Models of the forging based on CAD Data if helpful  Solid Debt Free Company for long term worry free supply.
12600, Cardinal Meadow #405, Sugar Land, TX , Cardinal Meadow #405, Sugar Land, TX
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Balancer Operation Intelift Operation Installation Troubleshooting Preventive Maintenance Preventive Maintenance OVERVIEW.
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
EPA Compliant Fuel Systems IBEX Sep 28, 2010 George Bellwoar.
CBS-7000 Series Coffee/Tea Brewers and Dispensers High Volume Brewing.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Connecting to industry. Purpose of Presentation A Avoid, or at least reduce liability through education & communication. D Dealing with maximum working.
What tests are necessary to make sure your kegs are being cleaned, sanitized and filled correctly By Andrew J. Brewer
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
1 1 Staying in Compliance: Spill and Overfill Presented by: Brent Roth OPW Retail Fueling IPECA UST Seminar 2015.
Maytronics – Exceptional pool experience 111 Maytronics 2010 New Models.
Automotive Heating and Air Conditioning, Fifth Edition By Tom Birch © 2010 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ.
Automotive Engines: Theory and Servicing, 7/e By James D. Halderman Copyright © 2011, 2009, 2005, 2001, 1997 Pearson Education, Inc., Upper Saddle River,
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
 Engineered Ball Valves that provide performance, longevity, and value that is superior to all other brands.  Available in Grade 1, Type1 Geon ® PVC,
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
Flammable Liquids Directorate of Training and Education
It’s…….
Edward S. Kubinsky Jr. CROMPCO, LLC
Fuel-Injection Systems
14 Refrigerant Recovery, Recycling, and Recharging.
Infrastructure & Safety
The Fuel Delivery System
Provides a continuous supply of ready to use product on demand
FIGURE 33-1 A typical fuel tank installation.
Company MIAB - Mölnbacka Industri AB of Deje, Sweden was established in MIAB provides equipment protecting the environment by removing solvent vapours.
Fuel Supply System Service
Overfill Prevention Technology and Maintenance
Introduction of fuel feed system
NEW COMPLIANCE REGULATIONS
FIGURE 18–1 A visual inspection on this battery shows the electrolyte level was below the plates in all cells.
Fuel-Injection Systems
T-6B On-Board Oxygen Generation System (OBOGS)
Risk Management Student Powerpoint
Presentation transcript:

Battery Watering Technologies

And now introducing… The Centurion Valves!

Centurion Valve Low profile design. Reinforced barbs eliminate the need for clamps. Push in style valve for easy installation and removal. All working parts are above the cell.

Centurion Valve Indicator eye visible from top and side. Angled barbs to help navigate around connectors. Solid polypropylene float. No more flip top lid. Ample spacing between the float and encapsulation.

Widest Pressure Range in the Business. Centurion Valve Widest Pressure Range in the Business.

Solid Polypropylene float Technology Solid Polypropylene float Won’t allow Electrolyte to leach Into the float

Part #: DF72G (Direct Fill Gun)

Part # NT2000G (5 gallon gravity tank) Part #: NT2212GF (2.5 gallon gravity tank)

Part #: NC5080P (8 gallon aqua sub) Part #: NC5250P (25 gallon push cart)

Part #: PW-1800 Deionizer

Superior Warranty We offer a full five year warranty that covers all aspects of a failure. If the cell fails due to a defect in our product, we pay for the repair!

Manufactured in the USA Manufacturing MADE IN THE USA! Manufactured in the USA

We Control the Process. Better Products. Superior Manufacturing. Highest Quality Standards.

State of the art ISO 9000 certified Manufacturing Facility ISO/TS 16949 Approved 2010 ISO14001 Approved 2010

Diversified 170 Employees 24 Hour Operation 85 To 1000 Ton Injection Molding Machines Ford Tier 1 Supplier Chrysler Tier 1 Supplier GM Tier 1 Supplier Mercedes Approved Source

Product Update Filling pressure: When using a BWT Direct Fill Gun/Link: 20-100 PSI Recommended fill pressures (into quick connect) 2-25 PSI. Up to 35 PSI can be used if recommendations below are followed.   Recommendations: Avoid pulsating water supply (pump rapidly cycling on and off) Always remove air from the line before filling

Product Update Filling outside of recommended pressure: If below 2 PSI: Valves will continue to perform but filling time increases. If above 25 PSI: Filling time will be reduced. It is possible that the final valve/cell to complete filling may close prematurely.

Single valve filling flow rate vs. fill pressure Filling Flow Rate Chart:  

Filling Flow Rate Valve String flow rate:   Valve String flow rate: Total flow rate depends on number of valves in string, Filling pressure and connection method. Typically 2-3 gallons/Minute at 20 PSI. Many different delivery options can be utilized.

Manufacturing is ISO-9001, ISO/TS-16949 certified. Quality Control Manufacturing is ISO-9001, ISO/TS-16949 certified. Each component part has a specific molding specification and testing procedure used during manufacture. Each valve tested for shutoff, flow and mechanical freedom during the assembly process. Sampling and water testing performed on each box of valves at manufacturing.   Incoming sampling and testing done on each box at BWT. Inventory is in quarantine until released by QC. Valves visually inspected during kit assembly.

Spark Propagation/Spark Arresting All valves have built in water trap (P Trap) to avoid cell-to-cell vapor transfer/Spark propagation. Valves for electric vehicles have spark arrestor to avoid external spark from involving cell.

Technology

Technology

Technology

Technology

Technology

Indemnification BWT carries a five million dollar product liability policy. Other Required Documents?

Great Customers, Great Partners Thank You Great Customers, Great Partners The Highest Quality Products Exceptional, personal customer service Unmatched Support Five Year Cell Replacement Warranty Private Label Options