© 2012 DEHN + SÖHNE / protected by ISO 16016 Site visits to Botas Lightning and Surge Protection 1.

Slides:



Advertisements
Similar presentations
ITU-T SG 5 Technical Session Lightning protection 12 December 2005, ITU Headquarters, Geneva ITU-T Technical Session Lightning Protection Highlights &
Advertisements

International Telecommunication Union Technical Session on Home Networks Geneva, 29/04/2011 ITU-T Study Group 5 Protection against Lightning Phil Day Australia.
International Telecommunication Union ITU-T Study Group 5 The need for special requirements Tetsuya Tominaga Technical Session on Home Networks Geneva,
International Telecommunication Union ITU-T Workshop Lightning Protection Technical Session December 2005, Geneva, Switzerland Risk assessment for.
Standards for the protection of radio installations
Relevant ITU-T Recommendations for the Protection of Base Stations
Electrical & Instrument Construction Department
Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
for Pipelines & Casings
© 2012 DEHN + SÖHNE / protected by ISO Separation Distance 1.
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
Committed to connecting the world Ninth ITU Symposium on ICTs, the Environment and Climate Change Kochi, India, 15 December 2014 Damage prevention and.
CPR Lightning Damage Investigation and Mitigation Strategies Peter Brackett Canadian Pacific Railway
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
DEHN + SÖHNE Lightning and Surge Protection according to IEC 62305
Telecom Cabling Grounding and bonding.
© 2007 DEHN + SÖHNE / protected by ISO Ex isolating spark gaps Examples of use.
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
Amateur Radio and Lightning Protection By Dave Land KD5FX Apr
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Cellular telecom networks. Coaxial Antenna Line 2 Introduction Waterproofing kits HYPERCELL ® Products offer all passive components between BTS and antennas.
Committed to connecting the world Ninth ITU Symposium on ICTs, the Environment and Climate Change Kochi, India, 15 December 2014 Damage prevention and.
“Equipment bonding jumpers: are they always necessary?” Massimo Mitolo, Senior Member, IEEE.
Earthing / Grounding Issues
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
Overvoltage Protection, A. Zeddam, Dakar, Senegal, 25 March 2015 ITU Regional Standardization Forum For Africa Dakar, Senegal, March 2015 Overview.
HOUSTON, TEXAS1 Corrosion Control and Monitoring ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Protection Against Transient Overvoltages
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
PSerc Lightning Protection: A Stroke of Luck? Theory and Application: Customer Side Low Voltage Systems Ward Jewell Wichita State University APPA 2005.
All rights reserved Surge Arrester.
International Telecommunication Union ITU-T SG 5 Technical Session “Lightning protection” 12 December 2005, ITU Headquarters, Geneva Risk regarding safety.
Wiring and Grounding.
A PRACTICAL TRAINING SEMINAR ON PLCC
This project has been funded with support from the European Commission. This publication [communication] reflects the views only of the author, and the.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
POWER HOUSE.
Ag. Mechanics for Beginning Teachers
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
Testing of Low Voltage Installations
Safety Around Irrigation Systems
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
1 RF Lightning Arrestors & Grounding Mike Baker, W8CM.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
ESS Grounding System Concept Fundamentals and Requirements
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
CIMB ATM of PETRONAS Station at Bukit Subang Surge Protection Solution with Jan GROUND CO., LTD Perfection Guarantee Security the 3 rd Generation.
Committed to connecting the world Overview of ITU-T SG5 Work on Damage protection and safety Guy-Michel KOUAKOU Chairman of Study Group 5 Regional Group.
Electrical Power II Unit 4-Overvoltages Unit 5-HVDC Unit 6-FACTS.
Grounding the Electrical System
A SEMINAR ON LIGHTNING ARRESTER
XTO Energy Safety Training
Grounding the Electrical System
UNIT V–ELECTRICAL SAFETY, WIRING &INTRODUCTION TO POWER SYSTEM
9. Deleterious effects of lightning and protective techniques
PV System Quality and Performance
Lightning and Surge Protection according to EN standard
HOME ELECTRICAL SAFETY
Agricultural Systems Technology II
Grounding for Amateur Radio
BY Presenter Name: G.V,Reddy DESIGNATION: Sr. General Manager
TRENTON Casing Filler Presentation
Electrical components and systems
Grounding Myths.
Corrosion Control and Monitoring
Presentation transcript:

© 2012 DEHN + SÖHNE / protected by ISO Site visits to Botas Lightning and Surge Protection 1

© 2012 DEHN + SÖHNE / protected by ISO BOTAS LPG Terminal: Tekridag Crude Oil Terminal: Ceyhan Gas compressor station: Sungurlu Lightning and Surge Protection 2

© 2012 DEHN + SÖHNE / protected by ISO BOTAS What have we seen LPG Termial No damage caused by lightning during the last years A few damage in the public housing due to switching surges Earthing arrangement of the whole site in good conditions Almost no SPDs in use for protection of power supply and data / IT systems Some buildings do not have external protection system Some earthing conductor / connections are painted / corroded Pipeline insolated flange near to water pump may not be connected to equipotential bonding Only one down conductor from test clamp to ground at the truck filling station and high earth resistance Lightning and Surge Protection 3

© 2012 DEHN + SÖHNE / protected by ISO BOTAS What have we seen Crude oil terminal Damage due to lightning of the telecom tower, Antenna and SPDs are destroyed. SPDs did not fit to application and installation was not correct. Spark gaps for insulating flanges are missing in upcoming tender documents Radioactive ESE terminals are still in use No SPDs for data / IT, except telephone lines SPDs are in use (SOLA, Mexico) which are not according to IEC (TS) Lightning and Surge Protection 4

© 2012 DEHN + SÖHNE / protected by ISO BOTAS What have we seen Compressor station Good lightning protection and earthing system But no SPDs for power, data, IT Interference between earthing and cathodic protection cable length of spark gap for insulating flange is to big Lightning and Surge Protection 5

© 2012 DEHN + SÖHNE / protected by ISO BOTAS What we suggest LPG Terminal Use of SPDs, at least Type 2 in public houses Modify earthing connection / down conductor as mentioned before Replacement of painted / corroded clamps Crude oil terminal Equip Telecom tower with up to date SPDs, installation according to instruction, SPD shall have selectivity to main fuse of the telecom panel. Replace ESE terminal with latest models Lightning and Surge Protection 6

© 2012 DEHN + SÖHNE / protected by ISO BOTAS What we suggest Compressor station Spark Gaps at insulating flanges should be installed direct to the flange with a cable connection as short as possible Cathodic protection system -Pipe should be equipped with insulation flange before entering / laving the soil! In general SPDs for power / data / IT shall be considered as it is required by IEC / TS Electrical and Electronic Equipment is under threat of damage and hence loss of control of the sites is possible. Lightning and Surge Protection 7

© 2012 DEHN + SÖHNE / protected by ISO BOTAS What we suggest In gerneral SPDs for power / data / IT shall be considered in BOTAS specificatins. Spark Gaps should be considered for insulating flanges for upcoming tenders Lightning and Surge Protection 8