TECHNOLOGICAL COMPARISON: INTENSIFIERS © 2012 CMS SPA - All rights reserved. This document is strictly confidential; CMS SPA reserves according to the.

Slides:



Advertisements
Similar presentations
HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.
Advertisements

840 MW of Green Electric generated per Day in 10 Acres of land
Mate Grinder MATE European Dealer Meeting Advantages of Automatic Controlled Punch and Die Grinding More regrinds, accurate material removal Protect.
Welcome to Malaga WeBex Common Rail Fuel System
MFET  1. Basic Principles  2. Hardware  3. Abrasives  4. Parameters  5. Capabilities  6. Advantages  7. Disadvantages.
Joy Mist Drilling System Presented By: Dave Paich Joy Mining Machinery
Hydraulics.
Introduction “…but we weary the unlearned, who need not know so much, and trouble the learned, who know it already.” From the preface, “To the Reader”
The 30M2 Continuous Miner. Customer Name 30M2 Overview %Heavy duty high power miner for mid-height seams %High productivity from efficient cutting and.
Geothermal Energy 2000 Geothermal Education Office.
Hydraulic Drives and Actuators. Description A hydraulic drive consists of three major parts: The generator (such as a hydraulic pump) driven by an electric.
Multiple-Pump Operation
MICRO HYDROELECTRIC POWER PLANT WITH CHAIN TURBINE
S.C. KOYO ROMANIA S.A. ALEXANDRIA TELEORMAN
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
Hydraulics For The Long Term
EPANET FOR PRESSURIZED PIPE SYSTEMS
Understanding Principles of Fluid Power Transmission
Directional Control Valve CV691. Present system New Proposed System with CV691 valve Directional Control Valve CV691 with integrated Flow Control Valve.
So… How does Smartcool achieve savings??.  Compressors use 70% of the energy in refrigeration and air conditioning systems.  The cooling cycle is dynamic.
Metso - Slurry Pumping.
RADIAL PISTON PUMPS AND MOTORS
Montabert The Alternative Drifters replacement THE ALTERNATIVE
HYDRAULIC MOTORS.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydraulic Systems The Basics.
Technical presentation ECF50-90
C.KotnigFCC Design Meeting FCC Beam Screen cooling Claudio Kotnig.
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
PVG PUMPS. PVG Pumps Currently 5 Displacements – 048 ml/rev (2.93 in ³) – 065 ml/rev (3.94 in³) – 075 ml/rev (4.60 in ³ ) – 100 ml/rev (6.00 in ³ ) –
Energy Consumption Energy consumption is measured in kilowatt. hours. A kilowatt hour is the amount of energy being consumed per hour. –Energy (kwh) =
Fluid Power Control.
Tips For Improvement IT ALL STARTS WITH YOU 1 Turn it off at lunch and breaks 2 Avoid idling more than 5 minutes 3 Limit cool down periods to 3 minutes.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Submitted by Pradeep pataskar Roll no.11031M02034.
TSM363 Fluid Power Systems Pumps and Motors Tony Grift
RECIPROCATING COMPRESSORS
COMPRESSED AIR ENGINE (An engine which runs on Air only)
Documento riservato – A solo uso interno / Confidential document – Internal use only LUNA DUO-TEC MP.
FLUID POWER CONTROL ME604C. FLUID POWER MODULE:02 ~ HYDRAULIC SYSTEM COMPONENTS.
Hydraulic Press in New Age --Drive your press with servo.
Miscellaneous Hydraulic Machine
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
CNC FEED DRIVES.
HIGH TEMPERATURE WATER HEAT PUMP (NH3)
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
The New C55* CPVSd 10-20hp People. Passion. Performance.
EXERCISES Two water reservoirs are connected by a pipe 610m of 0.3m diameter, f’=0.038 and the flow produced by the difference in water surface elevations.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
ABE 223 ABE Principles – Machine systems Pumps and Motors Tony Grift
INDUSTRIAL HYDRAULICS
Troubleshooting Hydraulic Pumps
RECIPROCATING COMPRESSORS BY DEEPA M S VARUNA TANDON
Basic principles of hydraulic symbols
Parul Institute of Technology
HYDRAULIC HOSES.
OH3 or OH5 Direct Drive API 610 Centrifugal Pumps
Welcome to Malaga WeBex سیستم سوخت رسانی ریل مشترک کاتر پیلار
HYDRAULIC HOSES.
ME444 ENGINEERING PIPING SYSTEM DESIGN
VED and VEDI VED and VEDI.
Electrical Engineering Fifth Semester
HOW TO SAVE MAXIMUM ENERGY IN YOUR COMPRESSORS INSTALLATION
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

TECHNOLOGICAL COMPARISON: INTENSIFIERS © 2012 CMS SPA - All rights reserved. This document is strictly confidential; CMS SPA reserves according to the law the ownership of this document with prohibition to reproduce it and to communicate it to bystanders without CMS SPA's written authorization

Parallel intensifiersOpposed twin Intensifiers TECHNOLOGY Power drive PumpElectric Servo Pump

Advantages parallel intensifiers: -Constant pressure signal = high quality cut - Redundancy (can run with only 2 intensifiers and do the any maintenance when you decide not when the machine breaks down) - No attenuator to be replaced. - Low Cycle time: 30 cycle/minute = Long time between replacement (all things equal there is less wear per hour with 3 intensifiers = longer time between seal replacement) - Air/oil heat exchanger (integrated) PARALLEL INTENSIFIER

Disadvantages opposed twin intensifiers - Pressure drops = less quality - No redundancy (production at the mercy of breakdowns) - Attenuator needed (reservoir) that has to be replaced (€ 5.000/10.000) - High Cycle time: 60 cycle/minute = High maintenance costs - Water/oil heat exchanger OPPOSED TWIN INTENSIFIER

POWER DRIVE PUMP Disadvantages pd intensifiers - Ultre High Cycle time: 300 cycle/minute = Ultra High maintenance costs due to the high speed and temperature - Working pressure: maximum pressure of 3800 bar = less cutting speed/quality - No redundancy (production at the mercy of breakdowns) - Pump flowrate fixed = high water consumption (water is consumed also when the head is closed) - Intensifier normally used for hydro cleaning applications = low cost, low pressure, low speed

Disadvantages electric servo pump -High Cycle time: 60 cycle/minute = High maintenance costs due to the high speed and temperature - Working pressure: maximum pressure of 3800 bar = less cutting speed/quality - No redundancy (production at the mercy of breakdowns) - Attenuator needed (reservoir) that has to be replaced (€ 5.000/10.000) - New technology: how many pump Techni already installed? ELECTRIC SERVO PUMP

SINGLE EFFECT MULTIPLIERS DOUBLE EFFECT MULTIPLIERS SINGLE EFFECT MULTIPLIERS WITH ENGINE DIRECT DRIVE ELECTRIC SERVO PUMP WORKING PRESSURE psi (4.100 Bar) psi (3.800 Bar) REDUNDANCY Yes: possibility to work also when there it is necessary to make maintenance to one cylinder No: machine downtime WATER FLOWRATE ==>= OPERATING COSTS > electric power - < water > electric power - > water < electric power - < water PISTONS CYCLES Low (30 cycle/minute) Middle (60 cycle/minute)High (300 cycle/minute) Middle (60 cycle/minute) MAINTENANCE COSTS Low Middle High Middle PUMP FLOWRATE Varying Fixed Varying NOISE HighMiddle Low COMPARISON

KMT SL-V 60 PLUSOMAX P4055VTECHNI ESP 55 POWER 45 kW (60 Hp) 30 kW (40 Hp) INTENSIFIER HYDRAULIC WITH THREE INTENSIFIERS HYDRAULIC WITH TWO INTENSIFIERS ELECTRIC WITH THREE PISTONS ELECTRIC WITH TWO INTENSIFIERS MAX PRESSURE 4150 bar 3800 bar WATER FLOW RATE 5 l/min4,5l/min4 l/min3,8l/min MAX ORIFICE SIZE 0,40mm0,38mm 0,35mm COMPARISON

9 TECNOCUT INTENSIFIERS RANGE

BAR INTENSIFIERS

BAR INTENSIFIERS

THANK YOU © 2011 CMS SPA - All rights reserved. This document is strictly confidential; CMS SPA reserves according to the law the ownership of this document with prohibition to reproduce it and to communicate it to bystanders without CMS SPA's written authorization