U PDATES ON D ESIGN AND A NALYSES OF THE P LATE -T YPE D IVERTOR X.R. Wang 1, S. Malang 2, M. S. Tillack 1 1 University of California, San Diego, CA 2.

Slides:



Advertisements
Similar presentations
Further Modifications to the ARIES T-tube Divertor Concept Jeremy Burke ARIES-Pathways Project Meeting Jan 26,
Advertisements

P OSSIBILITY OF THE H E -C OOLED S I C-C OMPOSITE D IVERTOR X.R. Wang 1, S. Malang 2, M. S. Tillack 1 1 University of California, San Diego, CA 2 Fusion.
CFD and Thermal Stress Analysis of Helium-Cooled Divertor Concepts Presented by: X.R. Wang Contributors: R. Raffray and S. Malang University of California,
High Performance Divertor Target Plate, a Combination of Plate and Finger Concepts S. Malang, X.R. Wang ARIES-Pathway Meeting Georgia Institute of Technology,
Page 1 of 15 Tungsten Structures for High Heat Flux Components: Opportunities & Challenges M. S. Tillack and the ARIES Team Japan-US Workshop on Fusion.
September 24-25, 2003 HAPL meeting, UW, Madison 1 Armor Configuration & Thermal Analysis 1.Parametric analysis in support of system studies 2.Preliminary.
D ESIGN I MPROVEMENTS OF THE W-B ASED D IVERTOR C ONCEPTS X.R. Wang 1, S. Malang 2, M. S. Tillack 1, J. Burke 1 University of California, San Diego, CA.
Thermo Fluid Design Analysis of TBM cooling schemes M. Narula with A. Ying, R. Hunt, S. Park ITER-TBM Meeting UCLA Feb 14-15, 2007.
Page 1 of 14 External Transition Joints for Tungsten Divertors D. Navaei, X. R. Wang, M. S. Tillack and the ARIES Team Japan-US Workshop on Fusion Power.
Japan-US Workshop held at San Diego on April 6-7, 2002 How can we keep structural integrity of the first wall having micro cracks? R. Kurihara JAERI-Naka.
P ROGRESS ON THE O VERALL P OWER C ORE C ONFIGURATION OF THE ARIES-ACT X.R. Wang 1, M. S. Tillack 1, S. Malang 2 1 University of California, San Diego,
September 24-25, 2003 HAPL Program Meeting, UW, Madison 1 Report on Target Action Items A.R. Raffray and B. Christensen University of California, San Diego.
First Wall Thermal Hydraulics Analysis El-Sayed Mogahed Fusion Technology Institute The University of Wisconsin With input from S. Malang, M. Sawan, I.
Thermo-fluid Analysis of Helium cooling solutions for the HCCB TBM Presented By: Manmeet Narula Alice Ying, Manmeet Narula, Ryan Hunt and M. Abdou ITER.
June 14-15, 2006/ARR 1 ARIES-CS Power Core Engineering: Updating Power Flow, Blanket and Divertor Parameters for New Reference Case (R = 7.75 m, P fusion.
June 14-15, 2007/ARR 1 Trade-Off Studies and Engineering Input to System Code Presented by A. René Raffray University of California, San Diego With contribution.
Thermal Analysis of Helium- Cooled T-tube Divertor S. Shin, S. I. Abdel-Khalik, and M. Yoda ARIES Meeting, Madison (June 14-15, 2005) G. W. Woodruff School.
Preliminary Assessment of Porous Gas-Cooled and Thin- Liquid-Protected Divertors S. I. Abdel-Khalik, S. Shin, and M. Yoda ARIES Meeting, UCSD (March 2004)
Experimental Verification of Gas- Cooled T-Tube Divertor Performance L. Crosatti, D. Sadowski, S. Abdel-Khalik, and M. Yoda ARIES Meeting, UCSD (June 14-15,
April 27-28, 2006/ARR 1 Support and Possible In-Situ Alignment of ARIES-CS Divertor Target Plates Presented by A. René Raffray University of California,
February 24-25, 2005/ARR 1 ARIES-CS Power Core Engineering: Status and Next Steps A. René Raffray University of California, San Diego ARIES Meeting GA.
Ceramic Breeder Blanket Conceptual Design for ARIES-CS Contributors: S. Malang, A.R. Raffray, and L. El-Guebaly ARIES Meeting University of Wisconsin,
Experimental Validation of Thermal Performance of Gas-Cooled Divertors By S. Abdel-Khalik, M. Yoda, L. Crosatti, E. Gayton, and D. Sadowski International.
October 24, Remaining Action Items on Dry Chamber Wall 2. “Overlap” Design Regions 3. Scoping Analysis of Sacrificial Wall A. R. Raffray, J.
Scoping Study of He-cooled Porous Media for ARIES-CS Divertor Presented by John Pulsifer Major contributor: René Raffray University of California, San.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski, B. H. Mills, and J. D. Rader G. W. Woodruff School of Mechanical Engineering Parametric Design Curves for.
June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)
Forschungszentrum Karlsruhe in der Helmholtz-Gemeinschaft 02/24/2005 T. Ihli PL FUSION FZK - EURATOM ASSOCIATION 1 He-cooled Divertor Development in the.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski and M. D. Hageman Woodruff School of Mechanical Engineering Extrapolating Experimental Results for Model Divertor.
March 20-21, 2000ARIES-AT Blanket and Divertor Design, ARIES Project Meeting/ARR Status ARIES-AT Blanket and Divertor Design The ARIES Team Presented.
Fracture and Creep in the All-Tungsten ARIES Divertor
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski and M. D. Hageman Woodruff School of Mechanical Engineering Update on Thermal Performance of the Gas- Cooled.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski, B. H. Mills, and J. D. Rader G. W. Woodruff School of Mechanical Engineering Updated Thermal Performance of.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski, M. D. Hageman, B. H. Mills, and J. D. Rader G. W. Woodruff School of Mechanical Engineering Extrapolating.
Engineering Overview of ARIES-ACT1 M. S. Tillack, X. R. Wang and the ARIES Team Japan/US Workshop on Power Plant Studies and Advanced Technologies
CS Thermal Analysis Status Heating and Cooling of CS During Normal Operation - SN & DN Operation –Overall Heat Balance –Heating of Center Stack First Cut.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski, B. H. Mills, and J. D. Rader G. W. Woodruff School of Mechanical Engineering Correlations for the Plate Divertor.
ITER test plan for the solid breeder TBM Presented by P. Calderoni March 3, 2004 UCLA.
U PDATED ARIES-ACT P OWER C ORE D EFINITION AND S I C B LANKET X.R. Wang, M. S. Tillack, S. Malang F. Najmabadi and L.A. El-Guebaly ARIES-Pathways Project.
E LASTO -P LASTIC -C REEP M ODELING FOR THE F IRST W ALL WITH W A RMOR X.R. Wang 1, S. Malang 2, M. S. Tillack 1 1 University of California, San Diego,
1 Parametric Thermal-Hydraulic Analysis of TBM Primary Helium Loop Greg Sviatoslavsky Fusion Technology Institute, University of Wisconsin, Madison, WI.
Page 1 of 15 Robust High-Performance First Wall Design and Analysis X. R. Wang, S. Malang, M. S. Tillack and the ARIES Team Japan-US Workshop on Fusion.
Forschungszentrum Karlsruhe FZK - EURATOM ASSOCIATION 05/14/2005 Thomas Ihli 1 Status of He-cooled Divertor Design Contributors: A.R. Raffray, and The.
R EFINEMENT OF THE P OWER C ORE C ONFIGURATION OF THE ARIES-ACT SA X.R. Wang 1, M. S. Tillack 1, S. Malang 2 and F. Najmabadi 1 1 University of California,
P LATE -T YPE D IVERTOR 3D P RINTING X.R. Wang D. Navaei ARIES-Pathways Project Meeting Gaithersburg, MD May 31-June 1, 2012.
Helium-Cooled Divertor Options and Analysis
Page 1 of 17 Evaluation of high heat flux components under normal and off-normal conditions M. S. Tillack with contributions from X. Wang, A. R. Raffray,
56 MHz SRF Cavity and Helium vessel Design
DCLL ½ port Test Blanket Module thermal-hydraulic analysis Presented by P. Calderoni March 3, 2004 UCLA.
U PDATES ON H IGH P ERFORMANCE H E - COOLED W D IVERTOR C ONCEPTS X.R. Wang 1, S. Malang 2, M. S. Tillack 1, J. Burke 1 and D. Navaei 1, 1 University of.
Page 1 of 8 Concept development of pin-fin cooled divertors M. S. Tillack ARIES Project Meeting July 2010.
DESIGN AND ANALYSIS OF AN INNOVATIVE FIRST WALL CONCEPT X.R. Wang 1, S. Malang 2, and M. Tillack 1 1 University of California, San Diego, USA 2 Fusion.
Mitglied der Helmholtz-Gemeinschaft Jörg Wolters, Michael Butzek Focused Cross Flow LBE Target for ESS 4th HPTW, Malmö, 3 May 2011.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski, B. H. Mills and M. D. Hageman G. W. Woodruff School of Mechanical Engineering Correlations for Divertor Thermal-Hydraulic.
1 A Self-Cooled Lithium Blanket Concept for HAPL I. N. Sviatoslavsky Fusion Technology Institute, University of Wisconsin, Madison, WI With contributions.
Page 1 of 19 Design Improvements and Analysis to Push the Heat Flux Limits of Divertors M. S. Tillack, X. R. Wang, J A. Burke and the ARIES Team Japan-US.
ARIES ACT1 Power Core Engineering M. S. Tillack, X. R. Wang, F. Najmabadi, S. Malang and the ARIES Team ANS 20 th Topical Meeting on the Technology of.
ISIS TS1 Project: Target Design and Analysis
DCLL TBM Reference Design
X.R. Wang, M. S. Tillack, S. Malang, F. Najmabadi and the ARIES Team
Improvements to power flow modeling in the ARIES system code
Integrated Design: APEX-Solid Wall FW-Blanket
DCLL Blanket Analysis and Power Core Layout for ARIES-DB
He-cooled Divertor Design Approach
Trade-Off Studies and Engineering Input to System Code
Modified Design of Aries T-Tube Divertor Concept
University of California, San Diego
Status of the ARIES Program
Thermal behavior of the LHCb PS VFE Board
Update on Fracture Analyses
Presentation transcript:

U PDATES ON D ESIGN AND A NALYSES OF THE P LATE -T YPE D IVERTOR X.R. Wang 1, S. Malang 2, M. S. Tillack 1 1 University of California, San Diego, CA 2 Fusion Nuclear Technology Consulting, Germany ARIES-Pathways Project Meeting UCSD, CA Jan , 2011

C URRENT S TATUS OF ARIES F INGER AND T-T UBE D IVERTOR C ONCEPTS 1. HCPF(He-cooled Combined Plate and Finger)* q”=15 MW/m 2 P p /P th <10% 700 ᵒ C < T <1300 ᵒ C for W structure Allowing yielding, within elastic regime after stress relaxation of plasticity 2. HCTT(He-Cooled T-Tube)*** Tapered ODS-steel cartridge q”=13 MW/m 2 P p /P th <10% 700 ᵒ C < T <1300 ᵒ C for W structure Within Elastic regime *X.R. Wang, S. Malang and M. S. Tillack, 19 th TOFE, to be published in Fusion Science and Technology. **M. Yoda, S.I. Abdel-Khalik et. all, 19 th TOFE, to be published in Fusion Science and Technology. ***J. Burke and et. all, 19 th TOFE, to be published in Fusion Science and Technology. **With pin-fin array, accommodating ~22 MW/m 2 (without stress verification)

STATUS OF THE ARIES PLATE- TYPE DIVERTOR CONCEPT Jet-to-wall distance h=1.2 mm Jet width D=0.5 mm Front plate, t f =2 mm Side wall, t s =3 mm Back plate, t b =8 mm Jet-to-wall distance h=1.2 mm Jet width D=0.5 mm Front plate, t f =2 mm Side wall, t s =3 mm Back plate, t b =8 mm q”=10 MW/m 2 q v =17.5 MW/m 3 P=10 MPa Tin/Tout=600/677 °C HTC=~4.822x10 4 W/m 2 K T thimble =1295 °C P P =9.7% P th σ (p+s) =359 MPa(within elastic regime) q”=10 MW/m 2 q v =17.5 MW/m 3 P=10 MPa Tin/Tout=600/677 °C HTC=~4.822x10 4 W/m 2 K T thimble =1295 °C P P =9.7% P th σ (p+s) =359 MPa(within elastic regime) 2 mm He insulator gap used to makes the cooling duct operating in range of °C to reduce thermal stresses 677 º C Outlet 600 º C Inlet X.R. Wang, S. Malang and R. Raffray, Fusion Science and Technology, 56, 1023(2009). One Channel One plate(front view) 3. HCFP(Helium-cooled Flat Plate) divertor One plate(Bird view) ~20 cm Half of 1 m

CAN THE HCFP CONCEPT BE SIMPLIFIED FOR PUSHING TO HIGHER HEAT FLUX? Getting rid off the U-shape wall for simplifying the design More space for increasing cross- sections for manifolds and reducing ∆P Increasing temperature design window Getting rid off the U-shape wall for simplifying the design More space for increasing cross- sections for manifolds and reducing ∆P Increasing temperature design window Verifications needed: CFD analyses Elasto-plastic analysis Cyclic thermo-mechanics 677 º C Outlet 677 º C Outlet 600 º C Inlet 600 º C Inlet Simplified to 7.2 cm 6 cm 2.2 cm Design Method: Allowing local yield and considering plasticity.

PARAMETER STUDIES AND OPTIMIZATIONS OF THERMAL PERFORMANCE BY USING CFX  CFX was used in the parameter studies and optimizations.  The plate without pin fins are used.  Different cooling conditions were analyzed ∆T1= ᵒ C (Original design) ∆T2= ᵒ C ∆T3= ᵒ C  Jet sizes are varying from 0.15 to 0.5 mm  The plate-type divertor can accommodate the surface heat flux up to 11 MW/m 2 while staying within temperature and pumping power constraints. T s <~1300 ᵒ C (Re-crystallization temperature) P p < ~10% P removed thermal power  The plate-type divertor with pin fins can enhance the heat transfer coefficient ( it is not included in this plot)** q’’<9 MW/m 2, ∆T3 is better option q’’>9 MW/m 2, ∆T1 is better option **M. Yoda, S.I. Abdel-Khalik et. all, ARIES meeting, May 2010

COMPARISON OF THERMAL PERFORMANCE FOR THREE CONCEPTS  W structure temperature limit 700 ᵒ C< T s <1300 ᵒ C  All thermal-hydraulic analyses were performed by CFX  Finger concept has better thermal performance.  The finger (HEMJ) with pin fins can handle the heat flux up to 22 MW/m 2.** (it is not shown) **M. Yoda, S.I. Abdel-Khalik et. all, 19 th TOFE Meeting,

E XAMPLE OF CFX T HERMAL -F LUID R ESULTS FOR HCFP q”=11 MW/m 2 q’’’=17.5 MW/m 3 P=10 MPa T in /T out =600/677 ᵒ C D jet =0.4 mm V jet =307 m/s Local H.T.C=7.64x10 4 W/m 2 -K P p =9.8%P removed thermal power Max. T armor = 1985 ᵒ C Max. T structure =1298 ᵒ C Min. T structure =716 ᵒ C q”=11 MW/m 2 q’’’=17.5 MW/m 3 P=10 MPa T in /T out =600/677 ᵒ C D jet =0.4 mm V jet =307 m/s Local H.T.C=7.64x10 4 W/m 2 -K P p =9.8%P removed thermal power Max. T armor = 1985 ᵒ C Max. T structure =1298 ᵒ C Min. T structure =716 ᵒ C Velocity distribution Temperature distribution (W-armor not shown)

T HERMO -M ECHANICAL A NALYSIS FOR THE H EAT F LUX UP TO 11 MW/ M 2  Only half of cooling channel is considered in the thermo- mechanical simulation.  ODS insert manifold is excluded from thermo-mechanical model.  Thermal boundary conditions and structural supports: the interface temperature of the He/W is imported from the CFX thermal results Thermal expansion and bending are free. Temperature distribution at interface of the He/W (CFX results) One coolant channel (without manifold)

E XAMPLE R ESULTS OF THE E LASTIC S TRUCTURAL A NALYSIS 11 MW/m 2 15 MW/m 2 Stress distributions  The plate-type divertor can accommodate the heat flux up to 9 MW/m 2 for maintaining the structure in the elastic regime (3S m =373 MPa at T s =1300 ᵒ C). Elastic regime

E XAMPLE OF E LSTO -P LASTIC A NALYSES FOR A H EAT F LUX OF 11MW/ M 2 Design Criteria: Allowable plastic strain has to be less than 50% of the uniform elongation of the material: Ɛ allow = ~0.8% for W at 270 ᵒ C Ɛ allow = ~1.0% for W at 1200 ºC Design Criteria: Allowable plastic strain has to be less than 50% of the uniform elongation of the material: Ɛ allow = ~0.8% for W at 270 ᵒ C Ɛ allow = ~1.0% for W at 1200 ºC  The maximum plastic strains calculated by ANSYS: Ɛ pl =~0.026% in the channel Ɛ pl =~0.03% in the armor  Total deformation is ~3.1 mm (increase of the plate length)  Plastic design criteria are met for the maximum surface up to 11 MW/m 2. Plastic strain of the cooling channel Plastic strain of the tiles (on the top of the channel) Plastic strain of the tiles (on the top of the channel) 0.026% 0.03%

EXAMPLE SHOWING STRESS RELAXATION FOR THE HEAT FLUX OF 11MW/M 2 Elastic Analysis Elastic-Plastic Analysis σ max =513 MPa, SF min =0.73 ASME code is not met. σ max =513 MPa, SF min =0.73 ASME code is not met. SF(safety factor)=3 S m /Combined primary and secondary stresses SF must be >1 σ max =368 MPa, SF min =1.01 ASME code is met. σ max =368 MPa, SF min =1.01 ASME code is met.

E LASTO -P LASTIC A NALYSES FOR THE H EAT F LUX UP TO 15MW/ M 2  The maximum plastic strains at the channel structure and the armor ~0.04% and 0.05%, respectively (allowable plastic strain Ɛ allow =~1%).  The structural behavior stays in the elastic regime after stress relaxation of the plasticity (3 S m =~410 MPa at T s =1265 ᵒ C). However, the pumping power for the heat flux of 15 MW/m 2 is too high and the minimum temperature < 700 ᵒ C. Max. Ɛ=~0.04% Max. Ɛ=~0.05% σ p+s =424 MPa ( 3 S m =~565 MPa at T s =1000 ᵒ C ) σ p+s =424 MPa ( 3 S m =~565 MPa at T s =1000 ᵒ C ) SF=1.03 SF=1.33 SF=1.08

S UMMARY AND C ONCLUSIONS  The HCFP divertor has been re-investigated and simplified by considering “yielding”, stress-relaxation and plasticity, and the U-tube for stagnant helium insulator gap inside of channel can be eliminated.  Parametric studies have been performed by 3D CFX, and thermal-hydraulic results indicate that: ∆T3=T exit -T inlet = ᵒ C is better option for the q”<9 MW/m 2 ∆T1=T exit -T inlet = ᵒ C is better option for the q”>9 MW/m 2  The simplified HCFP divertor can accommodate the surface heat flux up to 11 MW/m 2 while staying into the temperature and pumping power limits.  Stress is not very important limit constraint any more comparing to the temperature and pumping power when the local yielding is allowed.  However, it remains to be seen if cyclic loading leads to ratcheting with Ɛ Pl >Ɛ allow.  Modifications for all the divertor concepts are required to increase minimum W temperature from ~720 ᵒ C to >800 ᵒ C.