High gradient test results from X-BOX1 Ben Woolley XBOX Team CERN, Switzerland February 2014.

Slides:



Advertisements
Similar presentations
Andrew Moss ASTeC MICE Project Board 28 th June 2011 MICE RF System.
Advertisements

Henrik Loos LCLS FAC Meeting 27 October RF Gun Status LCLS Facility Advisory Committee Meeting October 26, 2005 Mechanical.
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
Structure testing and RF tests stands Jan Kovermann CERN On behalf of the CLIC structure test team.
Progress of the sub-harmonic bunching system (i.e. upgrading progress of BEPCII present bunching system) Pei Shilun for the SHBS team Accelerator center,
Test of LLRF at SPARC Marco Bellaveglia INFN – LNF Reporting for:
1 X-band Single Cell and T18_SLAC_2 Test Results at NLCTA Faya Wang Chris Adolphsen Jul
RF Synchronisation Issues
Ron Akre, Dayle Kotturi LCLS LLRF April 16, 2007 Linac.
R. Corsini, CLIC Project Meeting - 24 th May 2013 CTF3 1 CTF3: Highlights of the 1 st run R. Corsini for the CTF3 Team 1.
Alessandro Cappelletti for CTF3 collaboration 5 th May 2010 RESULTS OF BEAM BASED RF POWER PRODUCTION IN CTF3.
Walter Wuensch CLIC project meeting, 31 March 2015 Accelerating structure program: design and testing.
Linac Front-End R&D --- Systems Integration and Meson Lab Setup
X-Band and High-Gradient à la Carte
HIGH RF POWER TESTING FOR THE CLIC PETS International Workshop on Linear Colliders 20 th October 2010 Alessandro Cappelletti for the CLIC team with.
30 GHz waveguide line modification towards 12 GHz.
Test Facilities and Component Developments Sami Tantawi SLAC May 15, 2008.
Xbox-3 LLRF Ben Woolley Stephane Rey & Heiko Damerau.
TTF-II Status & Prospectives Nick Walker DESY 5 th ITRP Meeting – CALTECH.
ASTA roadmap to EPICS and other upgrades Remote monitoring and control DAQ Machine protection Dark current energy spectrometer.
XFEL SRF Accelerating Module Prototypes Tests at DESY Fermilab Seminar, July 21st Denis Kostin, MHF-SL, DESY.
An RF & High-Speed Acquisition Systems for High-Gradient Tests at CLIC Test Facility Raquel Fandos.
 High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.
Anders Sunesson RF Group ESS Accelerator Division
L-band (1.3 GHz) 5-Cell SW Cavity High Power Test Results Faya Wang, Chris Adolphsen SLAC National Accelerator Laboratory
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
EUCARD WP12 DESY 2015 Slide 1 EuCARD-2 is co-funded by the partners and the European Commission under Capacities 7th Framework Programme, Grant Agreement.
14 th ESLS RF Meeting – Trieste, September 2010 ALBA RF Status 1/28 ALBA RF Status Francis Perez.
J.L. Navarro (CERN), for the CLIC/CTF3 collaboration.
Summary of progress towards CLIC goals and next steps for structure testing 6 th X-band collaboration workshop, April 18 th- 20 th 2012 Steffen Döbert,
Jose Alberto Rodriguez.  Describe how we currently characterize structures at CTF3  Describe how we want to improve the characterization  Learn from.
EnEfficient RF Sources Workshop. June 2014 I. Syratchev X-band high RF power testing activity at CERN I.Syratchev.
CLIC Spain collaboration CIEMAT: AC structures and Dipoles magnetsCIEMAT: AC structures and Dipoles magnets CELLS - ALBA: Stripline kickers, Impedance.
PETS TESTING ANALYSIS 4 th X-band Structure Collaboration Meeting 3 rd May 2010 Alessandro Cappelletti for CLIC collaboration.
RF break-down studies in the CTF3 TBTS Accurate measurements on TBTS RF Break-Down Studies in the CTF3 TBTS 29 Jan Wilfrid Farabolini 1.
Status of high gradient experiments at Nextef Kazue Yokoyama, Toshiyasu Higo, Yasuo Higashi, Shuji Matsumoto, Shigeki Fukuda Accelerator Laboratory, KEK.
Some Results and Analysis from CTF3 1HG2012-April-18 Some Results and Analysis from CTF3 W. Farabolini - A. Palaia.
Comparison of breakdown behavior between klystron and beam driven structure W. Farabolini With the support of J. Kovermann, B. Woolley, J. Tagg 1HG2013.
XBOX-2 Signals Ben Woolley. Signals minus Vacuum.
1 CTF3 CLEX day July 2006 CLEX day 2006 Introduction G.Geschonke CERN.
High Power RF Measurements Ben Woolley, Amos Dexter, Igor Syratchev. Jan Kovermann, Joseph Tagg HG2013, Trieste June 2013.
CLIC developments Xband FEL linac introduction W. Wuensch Xband technology.
Calorimetric Power Measurements in Xbox-1 Xiaowei Wu.
High gradient test results from X-BOX1 Ben Woolley XBOX Team CERN, Switzerland December 2013.
Xbox and Structure testing news N. Catalan Lasheras, R. DeGiovanni, J. Giner-Navarro, G. Mcmonagle, I. Syratchev, B. Wooley, X. Wu
Superconducting Accelerating Cryo-Module Tests at DESY TESLA Technology Collaboration (TTC) Meeting, February 28 - March , Milano, Italy Denis Kostin,
Nextef status and expansion plans Shuji Matsumoto for KEK Nextef Group /5/51 4th X-band Structure Collaboration Meeting, CERN.
30GHz system improvements Jan Kovermann RF meeting
High-efficiency L-band klystron development for the CLIC Drive Beam High-efficiency L-band klystron development for the CLIC Drive Beam CLIC workshop,
X-Band Test Stands: Conditioning and Operational Algorithms Joseph Tagg National Instruments Switzerland.
High Power Crab Cavity Testing Ben Woolley HG2016 Argonne National Lab. 8 th June 2016.
2010 TESTING PROGRAM AND RESULTS FOR THE CLIC PETS X-BAND WORKSHOP ON RF STRUCTURES, BEAM DYNAMICS AND SOURCES 2 nd December 2010 Alessandro Cappelletti.
Areal RF Station A. Vardanyan
Breakdown position analysis
CLIC RF Structure Development Mtg, Alexey Dubrovskiy and CTF team
An X-band system for phase space linearisation on CLARA
N. Catalan Lasheras on behalf of a very large team
Application of moderate (5 MW) X-band power sources for the CLIC accelerating structures testing program and other projects I. Syratchev, CERN.
Ben Woolley CLIC Workshop 2016 (LCWS16) CERN, Switzerland 18/01/2016
RF Synchronisation Issues
Application of the moderate peak power (6 MW) X-band klystron’s cluster for the CLIC accelerating structures testing program. I. Syratchev.
12 GHz High Power RF components requirements for CEA activities
Experience with X band klystrons and solid state modulators at CERN
CLIC Klystron based. Updates 2017.
Recent high-gradient testing results from the CLIC XBoxes
RF Pulse Shaping.
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
CLIC Feasibility Demonstration at CTF3
3 GHz and 30 GHz Conditioning Programs
Operational Experience with LCLS RF systems
Presentation transcript:

High gradient test results from X-BOX1 Ben Woolley XBOX Team CERN, Switzerland February 2014

Overview System Layout Diagnostics BD detection and response Structure conditioning progress 100MV/m results for 26 cell accelerating structure Klystron vacuum/arcing issues Future developments 2

Gallery Bunker Clockwise from top-left: Modulator/klystron (50MW, 1.5us pulse) Pulse compressor (250ns, ratio 2.8) DUT + connections Acc. structure (TD26CC) Xbox-1 Layout

System Layout and diagnostics Pulse forming network Interlock systems Trig. And Clock HLRF D.U.T PC tuning piston control

Accelerating Structure Diagnostics CLIC Accelerating Structure 3 dB Hybrid RF Load Asymmetric Reflection Incident power Reflected Power Transmitted Power Ion gauge readout 50 dB directional coupler Upstream Faraday cup signal Downstream Faraday cup signal RF Power From Pulse Compressor WR90 Waveguide Input coupler Output coupler Beam-pipe

Accelerating Structure Diagnostics Faraday Cup Directional coupler Ion Gauge Structure output couplers RF Load Structure input couplers Temperature probe RF hybrid splitter (behind metal support) Ion Pump Vacuum valve Ion Gauge

Cavity Conditioning Algorithm Automatically controls incident power to structure. Short term: +10kW steps every 6 min and -10kW per BD event. Long Term: Measures BDR (1MPulse moving avg.) and will stop power increase if BDR too high.

BD Detection: Breakdown Transmitted pulse drops as the arc is established. Reflected power increases to the same order as the incident pulse. Faraday cup voltages are saturated: x increase in charge emitted. We can use the difference in time between the transmitted power falling and the reflected power increasing to find the BD cell location. The phase of the reflected signal is used to pinpoint cell location. Wilfrid Farabolini

Breakdown: Steps taken We stop the next pulse from occurring and wait 2 seconds to let the vacuum level recover. All the signals are logged to file for later analysis. Over seconds we ramp the power from zero back to the power set-point.

100 MV/m Full-fledged CLIC accelerating structure TD26R05CC build by CERN is successfully processed in XBOX1 up to 107 MW/m unloaded accelerating gradient at 250 ns pulses. We have started now study of breakdown rate evolution at the fixed (100 MV/m) gradient. CLIC XBOX ~7x10 -5 BrD/pulse ~2x10 -5 BrD/pulse Pulse: 50ns 100ns 150ns 200ns250ns

#1500 ~200 ns #668Total:11168 ~250 ns

BD cell location: TD26CC

BD cell location: TD24R05

Phase measurements Reflected phase are grouped and separated by 2  /3 About 25% of BDs see a drift in position: REF pulse is split in 2 parts that shows 2 different phases The overall phase change is always negative  BD arc is moving towards the input.

Wilfrid Farabolini New Developments Dark current signal has been split and sampled at 1.25GSPS. Also we’ve added incident RF signal diode. Used to collect data for stress model analysis of the 100 pulses leading up to a BD event. (Collaboration with Uni. Jerusalem) We have successfully demonstrated that we can produce a CLIC pulse shape using the pulse compressor and the phase programmer.

Recent 100MV/m run Large BD triggers period of lower BDR but increases dark current. Also after this period there are less cluster events 45% vs. 25%.

The big picture □ - Measured Values ○ - Rescaled by pulse width × - Rescaled to 100MV/m

Results: TD26CC UP-TIME Uptime~75% Re-Calibration of signal paths >1week Klystron debugging Uptime <50%

Klystron Vacuum + Gun Arcs Klystron gun arcs cause high vacuum for 20-50hrs

Klystron Vacuum + Gun Arcs

Xbox-1: Future Developments We will remove the XL5 from XBOX-1 to look at the gun ion pump. Regardless of the conclusion it will be moved to XBOX- 2 for system testing and conditioning at low powers <20MW. The new CPI XL5 tube (arrival in 2-3 weeks) will be put into the XBOX-1 test stand. The new tube will be tested up to full power and pulse width using the new load tree (pictured, vacuum leak checked and LLRF tested OK, now prepping for bake-out). The load tree will be moved to CTF-2 to condition the rest of the WG network. Connect klystron to dog-leg WG in order to start dog-leg waveguide commissioning in preparation for the beam loading experiment. See Alberto Degiovanni’s talk later today for: Continue to develop phase measurement analysis. Utilise other methods for BD cell location: dark current signals and X-rays emitted during BD. Soon to have installation of dark current energy spectrometer  Should give better indication of the energies involved in accelerating electrons and ions during a BD. As yet unclear if this will run on XBOX-1 or 2. Quicker/better method of calibration to be devised (less downtime). Continue conditioning of the TD26CC structure? 22

Thank You

Extra Slides

Future Developments: XBOX-2 LLRF Board Fully Tested PXI hardware purchased and Software partially completed Functional plan completed CPI-XL5 tube fully conditioned at SLAC

RF components & RF network integration

Future Developments: XBOX-3 4 turn-key 6 MW, GHz, 400Hz power stations (klystron/modulator) have been ordered from industry. The first unit is scheduled to arrive at CERN in October The full delivery will be completed before July 2015.

Online automatic adjustment of the compressed pulse (arbitrary) shape.

Summary TD26CC structure is conditioned up to 103MV/m for required CLIC pulse shape and BDR. Gun arcs in the klystron have slowed progress. Work and planning to greatly expand our testing capability is well underway.

Thank you for your attention!

Future LLRF Generation and Acquisition for X-band test stands IF 2.4 GHz Oscillator 9.6 GHz BPF Amp Vector Modulator RF out LO in LO out 12GHz vector modulated signal to DUT 2.9 GHz Oscillator X4 freq. RF LO IF RF 12 GHz BPF 12GHz CW reference signal 2.4GHz vector modulated signal 2.4GHz CW reference signal 11.6 GHz BPF X4 freq. LO IF RF Input MHz LPFs LO IF RF Input 2 LO IF RF Input 3 LO IF RF_Referance 12GHz CW reference signal 3dB hybrid Amp IF Amps Oscillators should be phase locked 1.6 GSPS 12-bit ADCs Digital IQ demodulation