Ergonomic Housing improvements to Personal Smoke Monitoring Device Team: Evan Wozniak Sarah Kostuk Christina Smith Aaron Prahst Multidisciplinary Senior.

Slides:



Advertisements
Similar presentations
A small taste of inferential statistics
Advertisements

DT Coursework By D. Henwood.
Developing a tool to monitor and help prevent concussions Instrumented Football Helmet Development Team Joseph Jackson (ME) Adam McCauley (ECE) Shawn Kachnowski.
AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew.
Analysis of frequency counts with Chi square
FRIDAY, JANUARY 8, 2010 RYAN MILLER – ME, PROJECT MANAGER CHRIS OXLEY – EE, LEAD ENGINEER RYAN ENYEART – ME, SYSTEM ENGINEER ALEX MANLEY – EE, SYSTEM ENGINEER.
SYSTEM DESIGN REVIEW FRIDAY, JANUARY 15, 2010 RYAN MILLER – ME, PROJECT MANAGER CHRIS OXLEY – EE, LEAD ENGINEER RYAN ENYEART – ME, SYSTEM ENGINEER ALEX.
P10057: Delivery and Scale-Up of a Monitoring Device for Human Smoking Behavior Ryan Miller – Project Manager Chris Oxley – Lead Engineer Ryan Enyeart.
WEDNESDAY, JANUARY RYAN MILLER – ME, PROJECT MANAGER CHRIS OXLEY – EE, LEAD ENGINEER RYAN ENYEART – ME, SYSTEM ENGINEER ALEX MANLEY – EE, SYSTEM.
FRIDAY, DECEMBER 18, 2009 RYAN MILLER – ME, PROJECT MANAGER CHRIS OXLEY – EE, LEAD ENGINEER RYAN ENYEART – ME, SYSTEM ENGINEER ALEX MANLEY – EE, SYSTEM.
Development of Laser Fuser Test Bed Project Number: P07501 Justin McMillan.
Simultaneous Localization and Map Building System for Prototype Mars Rover CECS 398 Capstone Design I October 24, 2001.
SE 555 Software Requirements & Specification 1 SE 555 Software Requirements & Specification Prototyping.
SE-4000 Portable Eye Wash Spray Fixture The Speakman Company University of Delaware Team: Wes Doyle Nate Griffith Matt Jaskot Jason McKnight.
BPT2423 – STATISTICAL PROCESS CONTROL.  Estimation of Population σ from Sample Data  Control Limits versus Specification Limits  The 6σ Spread versus.
Measurement System Analysis Kevin B. Craner Boise State University October 6, 2003.
Common Uses & Lab Ideas: Tips, Tricks & Calibration Notes Measurements Sensor Exploration Challenge Materials EKG Sensor PS-2111 Identify fluctuations.
CMS:Children Monitoring System By: Naif Almadhayan | Steven Smith | Mohammad Safar.
Ergonomic Housing improvements to Personal Smoke Monitoring Device Team: Evan Wozniak Sarah Kostuk Christina Smith Aaron Prahst Multidisciplinary Senior.
PAT Validation Working Group Process and Analytical Validation Working Group Arthur H. Kibbe, Ph.D. Chair June 13, 2002.
Bicycle Harvesting Waste Energy: Bicycle Power Generation MSD-I RIT-Systems Design Review Winter/Spring P12414 January 13, 2012 Group # P12414.
1. 2  Team Members:  Dan Fenton (CE) – Team Lead  Ryan Muckel (ME)  Christopher Freeman (ME)  Derek Zielinski (EE)  Eric Welch (EE)  Kennedy Kong.
Psy B07 Chapter 1Slide 1 ANALYSIS OF VARIANCE. Psy B07 Chapter 1Slide 2 t-test refresher  In chapter 7 we talked about analyses that could be conducted.
DESIGN REVIEW DESIGN REVIEW  Mason Verbridge  Evan McNamara  Steve Fleischmann  Artem Sivak P11032 Detail.
By the end of this chapter, you should:  Understand the properties of an engineering requirement and know how to develop well-formed requirements that.
1 Validation & Verification Chapter VALIDATION & VERIFICATION Very Difficult Very Important Conceptually distinct, but performed simultaneously.
1 Rev: 02/12/2007 MSE-415: B. Hawrylo Chapter 8 Concept Testing MSE-415: Product Design Lecture #5.
Final Idea: Working Drawing
Implementing Basic Differences Tests
ME 322: Instrumentation Lecture 9 February 6, 2015 Professor Miles Greiner Lab 4 and 5, beam in bending, Elastic modulus calculation.
SDMAY11-01 Advisor: Dr. Ajjarapu Team Members: Luke Rupiper Shonda Butler Andrew Nigro Ryan Semler Chad Hand.
Generic Approaches to Model Validation Presented at Growth Model User’s Group August 10, 2005 David K. Walters.
1 Topic 7 - Hypothesis tests based on a single sample Sampling distribution of the sample mean Basics of hypothesis testing Hypothesis test for a population.
EEG Biofeedback Device Ashley Anderson, Michelle Lorenz, Shikha, Ryan Thome, Chris Wegener Client: Dr. Daniel MullerAdvisor: John Webster.
Problem Statement Automotive and heavy equipment applications use sensors on machines to report temperatures, pressures, speeds, etc. to a central embedded.
Chapter 3 Dr. Bahaa Al-Sheikh & Eng. Mohammed Al-Sumady Intoduction to Engineering Introduction to Engineering Design 1.
OBTAINING QUALITY MILL PERFORMANCE Dan Miller
Chapter Twelve Copyright © 2006 John Wiley & Sons, Inc. Data Processing, Fundamental Data Analysis, and Statistical Testing of Differences.
Chapter 10 Verification and Validation of Simulation Models
February 20, 2013 David Alvarado Ethan Kruder Kirk Santure Jessica Spoll.
METHODS IN BEHAVIORAL RESEARCH NINTH EDITION PAUL C. COZBY Copyright © 2007 The McGraw-Hill Companies, Inc.
1 Copyright © 2011 Pearson Education, Inc. publishing as Prentice Hall.
Tracheostomy Care Overlay System J. Biggs, D. Bond, N. Campagnola, E. Doll, N. Hott Advisor: Dr. Liyun P. Wang Special Thanks to: Amy Cowperthwait UD Healthcare.
Lecture & tutorial material prepared by: Dr. Shaffi Shaikh Tutorial presented by: Dr. Rufaidah Dabbagh Dr. Nurah Al-Amro.
P15080: Flow Culture System Multi-Disciplinary Senior Design Problem Definition Review September 11, 2014 Collin Burkhart – Lead Mechanical Engineer Katelyn.
Introduction Suppose that a pharmaceutical company is concerned that the mean potency  of an antibiotic meet the minimum government potency standards.
Path The purpose of this project is to design a universal data recording device to monitor the health of a Dresser-Rand compressor during operation. In.
P16221 – FSAE Shock Dynamometer Problem Definition Review.
Process Asad Ur Rehman Chief Technology Officer Feditec Enterprise.
Apr. 26 Statistic for the day: Chance that a college student expects to be a millionaire by the age of 40: 1 in 2 Assignment: Begin to review for final.
Electrophotographic Cascade Development Apparatus Zachary FoggettiBridget Kearney Dalton MeadRuishi Shen Michael WarrenThomas Wossner.
Design of Goods and Services Chapter 5. Designing Goods Form design: Appearance and other sensory aspects of a product Contributes to customer expectations.
CHAPTER 15: Tests of Significance The Basics ESSENTIAL STATISTICS Second Edition David S. Moore, William I. Notz, and Michael A. Fligner Lecture Presentation.
PDS. Contents  Introduction  Definitions  1) Performance 1.0 Function 2.0 Appearance 3.0 Reliability 4.0 Environment 5.0 Ergonomics 6.0 Quality 7.0.
Textiles Year 9: Shorts Assessment: Design Brief, Specification, Planning and Making.
P10203 LV1 MOTOR CONTROLLER FINAL REVIEW MAY 14, 2010 Electrical: Kory Williams, Adam Gillon, Oladipo Tokunboh Mechanical: Louis Shogry, Andrew Krall.
Computer Hardware What is a CPU.
Statistical Significance
Instrumented Walker Skyler Bullington Tommy Frankenberger Larson Stacy
Unit 5: Hypothesis Testing
GPS-Enabled Inhaler Final Design Cost of Materials Abstract
The Opening Bell Deviation Theory
The Opening Bell Deviation Theory
Instructor Resources.
Chapter 2 The Process of Design.
Design Sample: Build a Swing
Team P15441 Mini Air Sub-System Design Review
Psych 231: Research Methods in Psychology
Final Status Update P09006 – Upper Extremity Exerciser
Instructor Resources.
Presentation transcript:

Ergonomic Housing improvements to Personal Smoke Monitoring Device Team: Evan Wozniak Sarah Kostuk Christina Smith Aaron Prahst Multidisciplinary Senior Design Systems Level Design Review

Background Device measures: – Puff volume – Volume drawn into lungs

Purpose Current cigarette testing may not reflect actual smoker puff profiles. The personal monitoring device will be used as part of a clinical study to gather information on real smoker puff profiles.

History P10054 Produced Proof of concept P10057 Improved upon Proof of concept FSI Developed proof of concept further and produced a functional first generation Prototype P12056 Will take the First Generation Prototype and improve on the ergonomics of the device including moving the pressure sensor into the hand piece. A wire will be used to transmit data rather than the current tubes. This project will also allow room in this hand piece for wireless components. Generation Three Will integrate wireless components into system.

Customer Needs 1.Cigarette holder does not alter the smoking behavior or manner in which the smoker smokes the cigarette. 2.Cigarette holder is ergonomic. For example it is lightweight and feels like holding a cigarette. 3.Cigarette holder will support the cigarette independent of the user 4.Cigarette holder will not hinder the act of lighting the cigarette. 5.Cigarette holder includes a flow path with and orifice plate to measure flow rate. 6.Cigarette holder encompasses the pressure sensor for flow rate measurements. See Appendix A of Preread.

Customer Needs 7.Cigarette holder has room for all the wireless electronic components needed to record and transmit the signal to the base unit and support any additional desired indicator lights. 8.Cigarette holder transmits pressure signal by wire to the base unit or an external fixture for testing. 9.Cigarette holder can handle a wide range of cigarettes including electronic cigarettes. 10.Cigarette holder and base unit are easy to maintain by the user. For example there is an easy way to store the holder to avoid loss. There is a comfortable way to attach the base unit to the subject 11.Base unit housing size is minimal yet has room for all wireless components. Preferably the size is no bigger than a cellphone 12.The final design includes ergonomic considerations, and potentially an improved solution for the chest bands to enhance wearability. See Appendix A of Preread.

Risks 1.Lead time on Pressure sensor causes delays on analysis for decision 2.Requirements are too large for ergonomic hand hold 3.Might not have means to survey a "powerful" sample size 4.Smoker does not want to use the product See Appendix B of Preread.

Risks 5.Rapid prototyping does not allow for accurate tolerances on orifice plate 6.Design hinders smoker ability to cover/ not cover vent holes 7.Not all plastic is FDA approved 8.Smoker does not hold ergonomic hand hold the way it was intended 9.Handhold is too heavy and breaks the cigarette See Appendix B of Preread.

Overview Decomposition See Appendix C of Preread.

P12056 Decomposition See Appendix D of Preread.

Benchmarking Current Prototype

Existing Pressure Sensor Specifications Measurement Range – 0-2” H2O Differential Pressure Resolution – Typ. 0.1% of Full-Scale Benchmarking Current Prototype

Benchmarking Existing Smoke Monitoring Devices CReSS Pocket by Borgwaldt Mobile SPA/M by Sodim

FSI Software Flowchart Benchmarking Current Prototype See Appendix E of Preread.

Benchmarking Results: Previous project 9 people were surveyed Avg. Age: 23.11yrs (Std. Dev 3.58 years) 8 Males, 1 Female Answer questions on scale 1-5 (1= BEST, 5=Worst) Questions regarding comfort of; hand piece, chest belt, and belt pack Results were inconclusive

Survey Plan: – Usability of current plan Survey data Actual device data – Calibrate sensor – Calibrate chest band Survey can be seen in appendix F of Preread Benchmarking Current Prototype

Benchmarking Marking Sample Size One way to prove that the new design is an improvement of the current design is to do an hypothesis test to show a statistically significant difference The original hypothesis is that the mean (µ) of the survey response of original product is “=“ the mean of the survey response of the new product The alternative hypothesis (what we want to prove) is that the mean (µ) of the survey response of original product is “≠ “ the mean of the survey response of the new product H 0 : µ 0 = µ a H A : µ 0 ≠ µ a

Yield a standard deviation of 1.3 (from results of previous project’s survey) Calculate the sample size needed to prove a statistically significant difference of 1.0 or 0.5 With an alpha (α) = 0.5 And a Power (confidence level) of 90%, 95%, or 99% Benchmarking Sample Size Alpha = 0.05 Assumed std dev= 1.3 Factors: 1 Number of levels: 2 Maximum Sample Target Actual Difference Size Power Power

Rapid Prototyping Concerns Lead time on Prototyping Strength of Parts – Strength of multiple part connections FDA approval of plastic for oral use Tolerances

Professor Cormier’s Input RIT’s equipment is better for larger parts Fastline is a company that does FDA approved rapid prototying Rapid prototyping is feasible outside RIT – Definitely cheaper that injection molding – Cost is dependent on material height

Input from FSI Needed wireless components – Physical room needed to be allotted for wireless components Are our prototypes sizes appropriate or do they need to be modified Do we design and fabricate the belt pack and if so what are the internal dimensions that FSI needs – If we are not fabricating it is it a purchased part?

FSI’s Input Rechargeable battery would be smaller than supplied dimensions 2 week life cycle with battery recommended Belt pack can be made smaller – Half the size in the x and y direction – Use mockup from previous group Chest belt: – How to make more user friendly Rather than spend a lot of money on a orifice plate that is exact, each mouth piece can be calibrated in a lab setting before use

FSI Input Could split board in half if needed.

Hand Piece Concepts

Hand Piece Concepts

Hand Piece Concepts

Hand Piece Concepts

Hand Piece Selection Brainstorm hand piece concepts (15 to 20)Produce prototypes of conceptsConduct Survey using prototypesAnalyze Survey Create scoring matrix to narrow down concepts to final selections Create 5 prototypes with full scale space claimConduct Survey In Ergonomics ClassNarrow Down to Three results

Input from Professor Marshal Have no more than 5 options for final survey Rigid finger holds are frowned upon for ergonomics Don’t need smokers to narrow down hand pieces Look at similar productions like a hookah mouthpiece.

A survey will be conducted where smokers are asked to simulate smoking using the 24 prototypes. They will be asked three questions about each object. The survey questions can be found in appendix G of the preread. Hand Piece Survey Plans

Handpiece Survey Plan In order to score the handpieces the mean survey response must be proven the be the neutral response of 3 This can be proven statistically using an hypothesis test ( 1 sample Z test) The original hypothesis is that the mean (µ) of the survey response of the design concept is “=“ 3 The alternative hypothesis (what we want to prove) is that the mean (µ) of the survey response of the design concept is “>” or “<“3 (this will be 2 separate tests) H 0 : µ 0 = 3 H A : µ a > 3 or µ a < 3

Yield a standard deviation of 1.3 (from results of previous project’s survey) Calculate the sample size needed to prove a statistically significant difference of 1.0 or 0.5 ( -1.0 or -0.5; alternative hypothesis of < 3) With an alpha (α) = 0.5 And a Power (confidence level) of 90%, 95%, or 99% Testing mean = null (versus > null) Calculating power for mean = null + Δ Alpha = 0.05 Assumed std dev = 1.3 Sample Target Actual Difference Size Power Power Hand Piece Survey Plans

Pressure Sensor Selection Process See Appendix H of Preread. Please see next slide for graph with losses using discharge coefficient.

Pressure Sensor Selection Process

Criteria for picking a differential pressure sensor: – It should have an operating pressure of at least 0 to 2.0” H2O – It should be small enough to fit inside the hand piece – It should be able to run off of a future battery inside hand piece

Sources 01-r-datasheet.html 01-r-datasheet.html Incropera, Frank P., David P. Dewitt, Theodore L. Bergman, and Adrienne S. Lavine. Fundamentals of Heat and Mass Transfer. 6th ed. Wiley, Print. The team would also like to thank Dr. Robinson and FSI for their support in this project.

Thank you for your time Questions/Comments