PI – Monitoring Energy in the Data Center Peter Vieites Technology Architect Microsoft Technology Center - New York.

Slides:



Advertisements
Similar presentations
Empowering Business in Real Time. © Copyright 2009, OSIsoft, LLC. All rights Reserved. Critical Facilities Update Regional Seminar Series Orlando Robert.
Advertisements

Empowering Business in Real Time. © Copyright 2009, OSIsoft, LLC All rights Reserved. PI for Energy Monitoring and Facilities Management in World Class.
Empowering Excellence in Real-Time Business Performance Tyler Bryson | General Manager | Microsoft.
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
Envision – Architect – Prove Scott Mauvais Technical Director Microsoft Technology Center.
Achieving Data Center Availability along with Efficiency by Management Systems Shimon Katz, Data Center Project Manager ELECTRICITY 2012 – Eilat, Israel.
Empowering Business in Real Time. © Copyright 2009, OSIsoft Inc. All rights Reserved. Virtualization and HA PI Systems: Three strategies to keep your PI.
IBM Energy & Environment © 2008 IBM Corporation Energy Efficiency in the Data Centre … and beyond Peter Richardson UK Green Marketing Leader.
Empowering Business in Real Time. © Copyright 2009, OSIsoft Inc. All rights Reserved. Introduction - PI for Facilities Regional Seminar Series Madrid Jesús.
© 2010 OSIsoft, LLC. – Company Confidential 1 Empowering Business in Real Time Regional Seminar Series Presents: Enrique Herrera Industry Market.
Virtual techdays INDIA │ 9-11 February 2011 Insight into Global Trends – A Peek into Financial Services Industry Santosh Khanolkar │ Director, Platform.
NetApp and Microsoft Alliance. Content  Technology and the Today World  Who are these players?, Alliance Overview  Motive & Fit and Mutual Benefit.
Schneider Electric IT Business North America Advancing Date Centers around Life Cycle Management. May 2011.
Empowering Business in Real Time. © Copyright 2009, OSIsoft, LLC. All rights Reserved. Using PI for Energy Monitoring and Facilities Management in World.
11 Establishing the Framework for Datacenter of the Future Richard Curran Director Product Marketing, Intel EMEA.
Microsoft Private Cloud Fast Track: The Next Generation of Private Cloud Reference Architecture Mike Truitt Sr. Product Planner Bryon Surace Sr. Program.
Darren Strange Head of Environmental Sustainability Microsoft Ltd.
© 2008 IBM Corporation Sales Training Power and Cooling Trends and Data Center Best Practices Ken Schneebeli STG Lab Services
Introduction to the Microsoft Private Cloud WSV207 Symon Perriman Technical Evangelist Microsoft WSV207.
CredoGov VDI Introduction James Gunn
1© Copyright 2014 EMC Corporation. All rights reserved. Results Lower CAPEX and OPEX Expected Savings of $800K over three years Improved visibility of.
“Clouds: a construction zone” (and Why PaaS is the future…) Matt Thompson General Manager, Developer & Platform Evangelism Microsoft.
Mobile data. Introduction Wireless (cellular) communications has experienced a tremendous growth in this decade. Most of the wireless users also access.
APC InfraStruxure TM Central Smart Plug-In for HP Operations Manager Manage Power, Cooling, Security, Environment, Rack Access and Physical Layer Infrastructure.
Copyright 2009 Fujitsu America, Inc. 0 Fujitsu PRIMERGY Servers “Next Generation HPC and Cloud Architecture” PRIMERGY CX1000 Tom Donnelly April
1 © 2008 OSIsoft, Inc. | Company Confidential Edison Mission Energy: PI for the Next Generation (of Generation) OSI Regional User Conference 10/09/08 Jerry.
© 2009 IBM Corporation Let’s Build a Smarter Planet Thongchai Watanasoponwong – Country Manager Power Systems, STG September 15 th, 2009 Green IT เทคโนโลยีสีเขียวเพื่อสิ่งแวดล้อม.
Connecting Vehicles and Transport to the Cloud GSMA Connected Living - mAutomotive Johan Gentzell. Industry Market Development Manager, Microsoft Corporation.
Significantly reduce energy costs with VMware virtualization solutions Virtualization Forum th of November 2008, Aegli Zappiou Significantly reduce.
1 GE Fanuc ©2008 GE Fanuc Intelligent Platforms All Rights Reserved Proficy* DataMart v1.0 Barry Lynch Product Manager GE Fanuc Software Puts the “E” in.
1 Dell World 2014 Reducing IT complexity and improving utilization though convergence infrastructure solutions Dell World 2014 Ravi Pendekanti, Vice President,
May l Washington, DC l Omni Shoreham Green Design and O&M Practices for Technology and Hosting Facilities Ben Pasley Manager, Lee Technologies, Inc.
HPC Business update HP Confidential – CDA Required
Mike Truitt Sr. Product Planner Bryon Surace Sr. Program Manager
Seminário Regional da OSIsoft do Brasil Curt Hertler OSIsoft, Cleveland, Ohio USA Seminário Regional da OSIsoft do Brasil 2008.
Project GreenLight Overview Thomas DeFanti Full Research Scientist and Distinguished Professor Emeritus California Institute for Telecommunications and.
© 2008 OSIsoft, Inc. | Company Confidential Enterprise Innovation using the PI Infrastructure Curt Hertler.
Energy-Efficient Infrastructure Management in the IoT era Presented by: George Dritsanos, IT BU VP for Greece, Cyprus & Malta.
Datacenter Energy Efficiency Research: An Update Lawrence Berkeley National Laboratory Bill Tschudi July 29, 2004.
SQL Server 2008 Analysis Services. END USER TOOLS & PERFORMANCE MANAGEMENT APPS Excel PerformancePoint Server BI PLATFORM SQL Server Reporting Services.
Power and Cooling at Texas Advanced Computing Center Tommy Minyard, Ph.D. Director of Advanced Computing Systems 42 nd HPC User Forum September 8, 2011.
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
Ulrich (Uli) Homann Chief Architect, WW Enterprise Services Microsoft Corporation SESSION CODE: ARC305.
Patrick Ortiz Global SQL Solution Architect Dell Inc. BIN209.
The VERSO Product Returns Portal Incorporates Office 365 Outlook and Excel Add-Ins to Create Seamless Workflow for All Participating Users OFFICE 365 APP.
© 2015 TriZetto Corporation Managed Services Overview Presenter Names 2.
Restricted © Siemens AG 2016 Page 1 Tower to Rack: Driving the Next Generation of Cooling Optimization Technology Jay Hendrix, Siemens Industry Inc. Aaron.
Monitoreo y Administración de Infraestructura Fisica (DCIM). StruxureWare for Data Centers 2.0 Arturo Maqueo Business Development Data Centers LAM.
Data Center Energy: Going Forward John Tuccillo, APC by Schneider Electric Founding Board of Director Member.
Breaking free from conventional thinking about CRM Presented by: Microsoft Dynamics CRM and HP platforms Plaza Dynamics Conventional Thinking: Integrated.
1 F5 and NetApp Partnership Applications and Users NAS and File Servers Transparent Data Migration F5 is a NetApp Advantage Alliace Partner with continuous.
© 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HP ProCurve 2910 Series Switches.
Rob Byrd Chief Enterprise Architect Enterprise Architecture – A Citywide Service Delivery Strategy Aligning Information Technology Services to the Citizen.
Extreme Scale Infrastructure
READ ME FIRST Use this template to create your Partner datasheet for Azure Stack Foundation. The intent is that this document can be saved to PDF and provided.
Scales Technology FZCO
Service Assurance in the Age of Virtualization
Healthy planet = higher profits HP’s approach to sustainability
Azure Infrastructure for SAP®
Greening Your Information Systems
Industrial IoT Derive business value from the Internet of Things, People and Services Ronald Binkofski General Manager Microsoft MC CIS.
The Future Is Current.
Dell Data Protection | Rapid Recovery: Simple, Quick, Configurable, and Affordable Cloud-Based Backup, Retention, and Archiving Powered by Microsoft Azure.
TrinityIoT Premises Monitoring.
2/25/2019.
DATS International Portfolio.
Presentation transcript:

PI – Monitoring Energy in the Data Center Peter Vieites Technology Architect Microsoft Technology Center - New York

Complexities in our Data Centers HVAC MECH BACKUP POWER Servers & Network Infrastructure UtilitiesPower Generation

Microsoft as an OSIsoft Customer: Data Center Innovation Greater energy-efficiency gains may be realized by optimizing the operation and efficiency of the data center as a holistic system. Microsoft Data Centers

Microsoft Technology Centers Offerings The MTCs marshal their premier resources into three unique offerings— Strategy Briefings, Architecture Design Sessions, and Proof-of-Concept workshops. Envision STRATEGY BRIEFING Create the right sales opportunity. Architect ARCHITECTURE DESIGN SESSION Deliver the details. Prove PROOF-OF-CONCEPT WORKSHOP Drive the deal home. 17 locations across the globe. Locally managed datacenters to build solutions in response to customer needs. OSIsoft enables all MTC sites to know their efficiency ratings and measure cost savings.

PI in the U.S. Microsoft Technology Centers Silicon Valley Boston New York Reston (D.C.) Atlanta Dallas Irvine Chicago Philadelphia (2010) Detroit (2010) Minneapolis (2010)

MTC Datacenters APC driven 80 KVA UPS power and 100 KW Network Air cooling. Over 120 Dell and HP servers providing over 500 total cores 250 Tb of storage capacity across NetApp, EMC, HP and Dell storage systems Brocade directors for fibrechannel. Gigabit network over Procurve switches.

PI System for MTC Data Centers Solution… Corporate Dashboard on SharePoint PUE, Energy Costs, Carbon Footprint, Month-To-Date Totals Site-to-Site Visualization and Analysis U.S. aggregation of KPIs Converged data aggregation on a single platform Power, HVAC, Servers and Applications, Environmental Sensors, Weather, and more… Vendor Agnostic using Standards Based Protocols Ad-Hoc Trending and Troubleshooting Automated Reporting – DataLink for Excel Excel 2007 Ribbon Integration Excel Services on MOSS 2007

NorthAmerica Dashboard

New York Datacenter Dashboard

PDU Summary Dashboard

UPS Summary Dashboard

Power Usage

Rack Detail Power Temperature Humidity Capacity

DataLink: Chiller Report

Mobility Integration “PI in your hand” Transpara Visual KPI software. Use Windows Mobile 6.5 as a platform to integrate data center PI metric data. Can use platform to build event driven alerts.

OSIsoft PI System to monitor all the critical points within our data centershigh-availability, global Live infrastructure “We are using the OSIsoft PI System to monitor all the critical points within our data centers, and in turn are laying the foundation for a high-availability, global Live infrastructure.” “The return on investment is tremendous. We are enabling innovation through increased collaboration, social networking and commerce—leading to breakthroughs in software plus services. We are setting industry standards with increased utilization of facility resources, real time business continuity, and green computing technologies. As we continue to expand our Live services, the combination of OSIsoft and Microsoft technologies are bringing new levels of performance and reliability to our world-class data centers.” Microsoft on PI in the Data Center