Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest 10.03.2008 Wolfgang Garche Saxony-Anhalt.

Slides:



Advertisements
Similar presentations
PART I Reference Material Requirements for Laboratories and the Role of Accreditation Bodies Alan Squirrell- ILAC Maree Stuart - NATA Laurie Besley - AGAL/NARL.
Advertisements

Dispelling Myths Surrounding ISO/IEC 17020
Ensuring Better Services and Fair Value “Introduction and roadmap to implementation of ISO in Zambia’s water utilities” Kasenga Hara March 2015.
Environmental Management System (EMS)
GReening business through the Enterprise Europe Network EN Giovanni FRANCO European Commission Enterprise and Industry EN
ISO Culture SHOQ Quiz 1. This program must be run in MS PowerPoint and requires sound. 2. Click “View” and then “Slide Show”. 3. Click “Continue”
EMODNet Chemistry Steering Committee January 2014 Rome Giordano Giorgi
World Health Organization
Corrective & Preventive Action Programme l Corrective and preventive action managed by one programme l Closely linked to the internal audit programme l.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Quality System in Air Quality Monitoring
OPTIMISING CHEMICAL ANALYSIS FOR THE WFD BY QUALITY ASSURANCE PROCEDURES & ACCREDITATION An Overview OPTIMISING CHEMICAL ANALYSIS FOR THE WFD BY QUALITY.
Transmille Training Quality System.
Quality Assurance/Quality Control Policy
Technical requirements  Sampling  Analysis  Reporting of the results.
ISO 9000 Certification ISO 9001 and ISO
Technical requirements:
5.2 Personnel Use competent staff Supervise as necessary
4. Quality Management System (QMS)
Webinar IIT & CII-FACE Certified Food Professional Course
4. Quality Management System (QMS)
LABORATORY MANAGEMENT SYSTEM
NVLAP Overview and Accreditation Process March 2006.
Bodil Mose Pedersen, DHI Status for implementering af ”Quality Manual”
BRC Food Safety Quality Management System Training Guide
World Health Organization
Ensuring of Traceability
ISO/IEC A review of the new standard for laboratory accreditation
What is Accreditation ? (According to ISO/IEC 17025)
Introduction to ISO New and modified requirements.
ISO 9001:2000 QUALITY MANAGEMENT SYSTEM REQUIREMENTS
| Folie | Folie 2 ISO approach to GHG-inventory QA/QC UNFCCC Workshop on National Systems April 2005, Bonn Doris.
Overview of existing assessment schemes Rolf Bienert, John Lin.
Lecture #9 Project Quality Management Quality Processes- Quality Assurance and Quality Control Ghazala Amin.
1 Saxony-Anhalt State Environmental Protection Agency Wolfgang Garche Bukarest EU-Twinning Project RO 2006 IB EN 09 Wolfgang Garche Saxony-Anhalt.
FSC402H FORENSIC SCIENCE AND THE EXPERT December 2, 2003.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
ISO / IEC : 2012 Conformity assessment – Requirements for the operation of various types of bodies performing inspection.
4.3 Document control 4.4 Review of requests, tenders and contracts
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheBukarest National Reference Laboratory for Air.
Requirements for the Competence of Providers of Proficiency Testing Schemes ILAC Guide 13:2000 – supplementing ISO Guides 43-1 and 43-2.
SAAMF Roadshow Durban CSIR NML Eddie Tarnow Metrologist: Torque & Automotive 14 June 2006 ISO/TS 16949:2002 certification – Meeting the requirements of.
ISO MONITORING AND MEASUREMENT. ISO Environmental Management Systems2 Lesson Learning Goals At the end of this lesson you should be.
Traceability: What is traceability? Competent transfer of traceability from a Standard to the device under test. CALIBRATION CERTIFICATES : ISO/IEC 17025:2005.
Development of Agreement Concerning the Adoption of Uniform Conditions for Periodical Technical Inspections of Wheeled Vehicles and the Reciprocal Recognition.
International Atomic Energy Agency Quality Management System ASSESSMENT OF OCCUPATIONAL EXPOSURE DUE TO EXTERNAL RADIATION SOURCES AND INTAKES OF RADIONUCLIDES.
Checking and Corrective Action EPA Regions 9 & 10 and The Federal Network for Sustainability 2005.
WORKSHOP ON ACCREDITATION OF BODIES CERTIFYING MEDICAL DEVICES INT MARKET TOPIC 9 CH 8 ISO MEASUREMENT, ANALYSIS AND IMPROVEMENT INTERNAL AUDITS.
1 SMA/November 2007 ISO/IEC 17025: International Organization for Standardization.
NCSLI 2007 Training Records from an Auditors Viewpoint Shawn Mason Boston Scientific.
Visit us at E mail: Tele:
KENYA ACCREDITATION SERVICE Doris Mueni - Msc. Med. Microbiology
QUALITY REQUIREMENTS FOR OFFICIAL FOOD LABORATORIES WITHIN EURL AND NRL (LABORATORY NETWORKS IN EUROPE) dr. Tina Pirš, dr. vet. med. Quality Manager, Veterinary.
DOCUMENTATION ISO/IEC 17025:2005 Documentation.
Laboratory equipment Dr. W. Huisman Cairo, November 21th 2012.
Quality Control significance in pharmaceutical industry
Dec. 6, 2010 Gum-Ho Choe Accreditation of Software Testing Working Group, APLAC Technical Committee.
Table 1. The Five Medical Laboratory Case Studies Jan Martin et al. Transnational Evaluation of a New Continuing Professional Development Activity for.
IAEA International Atomic Energy Agency Lecture 8 – Quality management system Postgraduate Educational Course in radiation protection and the Safety of.
Module 02 Essential Requirements for ATCOs. Training Objectives  Appreciate the content of the essential requirements for ATCOs as described within EASA.
A LOOK AT AMENDMENTS TO ISO/IEC (1999) Presented at NCSLI Conference Washington DC August 11, 2005 by Roxanne Robinson.
ISO/IEC FDIS : 2017 โดย นางสาวรัชฎาธร กังวาลไกล ผู้เชี่ยวชาญเฉพาะด้านการรับรองระบบงาน สำนักงานคณะกรรมการการมาตรฐานแห่งชาติ
ISO/IEC
Testing and Certification according to ISO and ISO 17065
Achieving ISO Compliance
An Introduction to Quality Assurance in Analytical Science
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Technical requirements:
International Organization
Emulsion Task Force Meeting
Presentation transcript:

Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Wolfgang Garche Saxony-Anhalt Environmental Protection Agency Department Air Quality Monitoring, Information, Assessment EN ISO/IEC Technical Requirements

Twinning Project RO2006/IB/EN/09 2 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest What means accreditation in accordance to EN ISO/IEC Confirmation of competence of a testing or calibration laboratory by an independent third party, the accreditation body, to carry out specific tests and/or calibrations. Annex I C. Quality assurance for ambient air quality assessment, data validation To ensure accuracy of measurements and compliance with the data quality objectives …, the appropriate competent authorities and bodies designated pursuant to Article 3 shall ensure: that the national laboratories, … are accredited according to EN/ISO by 2010 for the reference methods referred to in Annex VI Directive on ambient air quality and cleaner air for Europe

Twinning Project RO2006/IB/EN/09 3 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest personnel 2. accommodation and environmental conditions 3. test and calibration methods and method validation 4. equipment 5. measurement traceability 6. reference standards and reference materials 7. handling of test and calibration items 8. assuring the quality of test and calibration items Technical requirements

Twinning Project RO2006/IB/EN/09 4 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Personnel  appropriate staff (quantity and qualification)  personnel training and education procedures for identifying training needs effectiveness of training actions shall be evaluated  own personnel (employed by or under contract to the laboratory)  authorization of specific personnel to perform specific types of sampling, tests or calibrations to issue test reports and calibration certificates to operate particular types of equipment

Twinning Project RO2006/IB/EN/09 5 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Accommodations and environmental conditions  Laboratory facilities  Monitoring the environmental conditions Tests and calibrations shall be stopped when the environmental conditions jeopardize the results of the tests and/or calibrations.  Preventing cross-contamination  Access to the laboratory  Good housekeeping

Twinning Project RO2006/IB/EN/09 6 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Test and calibration methods and method validation Reference methods mentioned in Annex VI: EN 14212:2005 "Ambient air quality – Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence“ EN 14211:2005 "Ambient air quality – Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence“ EN 14902:2005 "Standard method for measurement of Pb/Cd/As/Ni in the PM10 fraction of suspended particulate matter" EN 12341:1999 "Air Quality – Determination of the PM10 fraction of suspended particulate matter – Reference method and field test procedure to demonstrate reference equivalence of measurement methods" EN 14907:2005 "Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter" EN 14662:2005, parts 1, 2 and 3 "Ambient air quality – Standard method for measurement of benzene concentrations" EN 14626:2005 "Ambient air quality – Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy" EN 14625:2005 "Ambient air quality – Standard method for the measurement of the concentration of ozone by ultraviolet photometry"

Twinning Project RO2006/IB/EN/09 7 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest  the calibration of analysers and other test and measurement devices  the certification of test gases (from cylinders or generators)  the production of test gas mixtures (permeation, dilution, etc) (e.g. ISO Permeation method) Validation of applied methods and procedures A Member State may use any other method if it can be demonstrated that the results are equivalent to the reference method.  Non-standard methods  Laboratory designed/developed methods  Standard methods used outside their intended scope  Amplifications and modifications of standard methods Other needed methods and procedures for:

Twinning Project RO2006/IB/EN/09 8 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Estimation of uncertainty of measurements A calibration laboratory shall have and apply a procedure to estimate the uncertainty of measurements for all calibrations and types of calibration. (EN ISO Air quality – Guidelines for estimating measurement uncertainty ENV Guide to the Expression of Uncertainty in Measurement (GUM) )

Twinning Project RO2006/IB/EN/09 9 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Equipment  Laboratory shall be furnished with all items of sampling, measurement and test equipment for the correct performance of the tests and/or calibrations (5.5.1).  Equipment used for testing, calibration and sampling shall be capable of achieving the required accuracy and shall comply with the specifications relevant for the tests and/or calibrations concerned (5.5.2).  All new equipment purchased for implementation of this Directive must comply with the reference method or equivalent by two years after the date of entry into force of this Directive.  All equipment used in fixed measurements must comply with the reference method or equivalent by five years after the date of entry into force of this Directive Directive on ambient air quality and cleaner air for Europe

Twinning Project RO2006/IB/EN/09 10 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Measurement traceability The appropriate competent authorities and bodies designated pursuant to Article 3 shall ensure: that all measurements undertaken in relation to the assessment of ambient air quality pursuant to Articles 6 and 9 are traceable in accordance with the requirements set out in Section of the ISO/IEC 17025:2005  If calibration is a dominant factor of the uncertainty budget the requirements of should be strictly followed ( )  The programme for calibration of equipment shall be designed and operate so as to ensure that calibrations and measurements are traceable to the International System of Units (SI) Directive on ambient air quality and cleaner air for Europe

Twinning Project RO2006/IB/EN/09 11 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest  Traceability can be established by means of an unbroken chain of calibrations or comparisons. The link to SI units may be achieved by reference to national standards.  When using external calibration services, traceability shall be assured by the use of services from laboratories that can demonstrate competence, measurement capability and traceability.  Calibration certificates shall contain the measurement results, including the measurement uncertainty and/or a statement of compliance with a identified meteorological specification.

Twinning Project RO2006/IB/EN/09 12 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Reference standards and reference materials  Laboratory shall have a programme and procedure for the calibration of its reference standards (RS).  RS shall be calibrated by a body that can provide traceability  RS shall be used for calibrations only  Reference materials shall be traceable to SI units or to certified reference materials (CRM)  Internal reference materials shall be checked (if practicable)  Intermediate checks are needed to maintain confidence in the calibration status of reference, primary, transfer or working standards and reference materials.  Checks shall be carried out to defined procedures and schedules. (5.6.3)

Twinning Project RO2006/IB/EN/09 13 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Handling of test and calibration items Laboratory shall have  procedures for the transportation, receipt, handling, protection, storage, retention and/or disposal of test and /or calibration items, including all provisions necessary to protect the integrity of the test or calibration item  a system for identifying test and/or calibration items  procedures and appropriate facilities for avoiding deterioration, loss or damage to the test or calibration items

Twinning Project RO2006/IB/EN/09 14 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Assuring the quality of test and calibration items Laboratory shall have quality control procedures for monitoring the validity of tests and calibrations. Resulting data shall be recorded in such a way that trends are detectable. Where practicable statistical methods shall be applied to the reviewing of the results. This monitoring shall be planned. The monitoring may include:  regular use of certified reference material  participation in interlaboratory comparisons or proficiency-testing programmes  replicate tests or calibrations using the same or different methods Quality control data shall be analysed and, where they are found to be outside pre-defined criteria, planned actions shall be taken to correct the problem.

Twinning Project RO2006/IB/EN/09 15 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Scope of accreditation:  reference methods specified in Annex VI  calibration procedures for  analysers,  measurement and control facilities for volume flows,  temperature and pressure sensors  procedures for the preparation of test gas mixtures

Twinning Project RO2006/IB/EN/09 16 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Many Thanks for your Attention!