1 Greg Nolan Mark Pelton Mike Bannister Presented By.

Slides:



Advertisements
Similar presentations
1 Compliance & Credits: The Tools, The Rules and How They Affect Your HUD Multifamily Housing Project (Real Estate Assessment Center Inspections) Presented.
Advertisements

2/1/ TOP TEN REASONS FOR FAILING A MANAGEMENT AND OCCUPANCY REVIEW Presented by Robert Kriensky GH CAPITAL, LLC.
ONE STOP Real Estate Services G ill G roup
Presented by Larry D. Davis Terrence J. Kelley Michelle DeVastey
Facilities Management and Design Chapter 4 Safety and Security systems.
Tam Valley School Modernization - Phase 1 Summer 2011.
KBHome 60 Day Maintenance Visit KBHome. Faucet Aerator Cleaning or replacing the aerator. Cleaning or replacing the aerator. Twice a Year Twice a Year.
The Greenwood Apartments a partnership between Banc of America Community Development Corporation and Clearwater Neighborhood Housing Services, Inc.
Fire Safety Fires occur in more than 350,000 homes and kills more than 3000 people each year in the United States. Four leading causes of house fires:
Housing Quality Standards & Request for Tenancy Approval
What to look for, What to correct, How it should look,
“Let us lend a helping hand” County of Sacramento Building Inspection Document #CO-183/10/2011.
INSPECTIONS WORKSHOP July 18, 2014 CMHA HOUSING CHOICE VOUCHER PROGRAM.
Visitors Guide to Housing in Ithaca. What is a lease? A Lease is a legal document. It protects the owners investment and tenants rights. Without a lease.
A training module for house directors.  It is our hope that students will form a community that is supportive and that holds its members accountable.
Farmworker Housing Inspections Unit 3: Conducting the Inspection.
CODE ENFORCEMENT DIVISION.  PURPOSE OF NUISANCE ORDINANCE:  It is the purpose of the nuisance ordinance to establish means whereby the City may remove.
AN ANALYSIS OF THE RESIDENTIAL RENTAL DWELLING LICENSING PROGRAM CITY OF ELYRIA LORAIN COUNTY, OHIO Presented by, Kevin A. Brubaker Senior Manager—Building.
The Life Safety Surveyor Facility Tour
0 Physical Assessment System Overview. 1 PASS Overview The Physical Assessment Subsystem (PASS) measures the physical condition of HUD properties through.
Section 8 Voucher Program, Poverty Dispersion Analysis. Rene Rodriguez Lara Angel Ramirez.
Objectives : ANALYZE home maintenance techniques.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
DST H.O.M.E. Home Ownership Maintenance and Education Property Maintenance: Protect Your Property Value.
King James Construction Cost Estimating Rob Himler, Ken Coutain, David Reger, Ruoyu Huang, Bei Xiong, Hanbing Ye.
HFA Institute REAC Uniform Physical Condition Standards January 12, 2015.
Business Owners and Managers and the Fire Code
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Congrats!! You just signed the lease to your very FIRST apartment! Now you are in charge for paying rent, maintaining the apartment, and learning to live.
Construction Residential Houses Definition of a House: A structure serving as a dwelling for one or more persons, especially for a family.
To Do: 1.Egg Babies due – get stamped! 2.Apartment Search due Tuesday! 3.Buying a Home Power Point – take notes for quiz Tuesday! 4.Bring budget WS Tuesday.
CODE ENFORCEMENT. Code Enforcement Code Enforcement Officers work in twelve geographically defined code enforcement areas. In each area the inspectors.
Building Codes and Interior Design
U.S. Department of Housing and Urban Development 1-3 Objectives Describe the purpose of the Physical Inspection Program and its contribution to achieving.
Week 3. Electrical Code 1. all electrical outlets run off a pigtail from main line 2. Each Circuit is wired directly into circuit panel - no junction.
Fire Safety. In 2011 fire departments responded to 370,000 home structure fires.
/0103 Copyright © 2001 Business & Legal Reports, Inc. BLR’s Safety Training Presentations Good Housekeeping 29 CFR (a)
Housing Safety and Zoning Code Enforcement Initiative Department of Health and Social Services Environmental Inspections Division.
Performing Missions for America - Safely Monthly Safety Briefing January Northeast Region Mission-Oriented Safety.
Common Rental Property Code Compliance Issues Zoning – property usage Building Inspection – minimum standards for construction Housing Code – minimum standards.
PROCEDURES FOR PHYSICAL INSPECTIONS Compliance Audit Investigator (Inspector) will:  Provide random sample list of units to property upon arrival  Explain.
HM101 – Inspections in Depth Presented by Jay Flynn Building Safety Facilitator,AILG/MIT.
Tangible Property Regulations Presented by David W. Jennings, CPA.
Electrical Plans.
1 OF 22 INFO:This is an exterior entry door. The door cannot be locked. There are two deficiencies. DEF: Damaged Hardware/Locks (Doors) - L3 Damaged Surface.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Let’s learn to prevent disaster
1 AAHRA/HUD 2007 Spring Workshop (Preparing for a REAC Physical Inspection) May 8 - 9, 2007.
Southeast Financial Center
Slide 1 of 33 Home Inspection Class Redfin’s Montgomery Team September 5, Bethesa, MD Host: Michael Wells & Margaret Plumly Like:
1 Southwestern Affordable Housing Management Association (Special Training: REAC Inspections) February 21, 2008.
Transfer Station Safety OR WORKER AND PUBLIC RISK.
1 Oregon AHMA Bootcamp Friday “How to prepare your property for a REAC inspection!” February 29, 2008.
Day 1 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Identifying Information: Building Exterior - 1 You observe damage to the frame on this exterior entry door. The door cannot be locked. LEVEL 3.
Preparing For A REAC Inspection Presented by: Patrick Ortiz Lead Housing Programs Analyst New Mexico Mortgage Finance Authority (505)
PASS Training. Dine and Learn is a new initiative undertaken by the PASS Training division. Its purpose is to highlight and provide clarification on issues.
Routine Inspections 1 1.
DINE & LEARN.
Safety and Prevention of Typical Fire Plan
Inspectional Services
Objectives : ANALYZE home maintenance techniques
Renting your First Apartment
St. Louis County, Missouri
Understand Code Requirements
Understanding Common Code Issues
How & When to Get Permits for Work in Your Home
Physical Assessment System Overview
Home Management for First Time Homeowners Class 2: Home Maintenance
Building standards Mr. Da Silva.
Presentation transcript:

1 Greg Nolan Mark Pelton Mike Bannister Presented By

 29 years in Co-op property management  Over 300 REAC inspections performed  Regional Maintenance Supervisor  REAC Inspector training  Over 75 inspections in the 90’s  Registered Cooperative Manager  MAHC trainer for 10 years 2

 60 REAC inspections Performed  9 years as a Regional Property Manager  MAHC trainer for 9 years  Certified Apartment Property Supervisor  Registered Cooperative Manager 3

 12 years as a Property Maintenance Supervisor  Assisted in over 12 REAC inspection  Improved REAC scores from 60’s to 90’s  Awarded Maintenance Supervisor of the Year by Kirkpatrick Management Co.  Turned property around from non performing to performing and cash flowing 4

 How to schedule, prepare & conduct  Scoring  Deficiency Items  The report  How to appeal-instructions 5

6 WHAT IS REAC?

 Acronym for  R eal  E state  A ssessment  C enter 7 *HUD’s way of assessing Safe, Decent & affordable housing What is the purpose of a REAC? To give oversight on the physical condition of subsidized properties.

 Reverse auction-Mortgage Inspection  Agreed upon day of inspection-who can schedule-one person in the company  Period of Performance  Rescheduling Inspection/Delaying Inspection  Site is undergoing Rehab-any type  Natural Disaster-Tornado/flood/fire 8

9 PREPARING FOR REAC

When to Start  After last REAC  3 months before scheduled or  anticipated REAC date. 10

 Documents Needed  Measurement of walkway by square feet, parking lots & roadways by sq ft.  Property Map & Rent Roll  Notice of Inspection  Show Lead Based Paint Inspection Report & 5 member files showing LBP Disclosure form  Occupancy Rate 85% and above 11

12 # of Units: 87 # of Vacants: Step 1: Subtract Number of Vacants from the number of units. *74 is total number of OCCUPIED UNITS Step 2: Divide # Occupied units by Total # of Units 74 ÷ 87 = % - Occupation Calculation

 Know your property  Schedule unit inspections  Inspect, Repair, Highlight  Schedule exterior inspections  Assess scope of work  How many work orders  What work will be done by staff, contractors, or members.  Cost of performing work: (concrete patching, drywall repairs)  What was your last score?  Have you completed unit inspections since the last REAC inspection  Did you fix items noted in last REAC inspection report? 13

14 REAC SCORES

 years  years  year  59-31Failing, not necessarily referred to enforcement center  30 & belowComplete failure-automatically referred to enforcement 15

The DEC take action against owners that do not live up their responsibility of providing safe, clean and sanitary housing DEC Actions Include  Abatement of federal subsidies  Civil money penalties  Foreclosure on properties  Referral to U.S. Attorney’s Office 16

 Level 1 Deficiency – Lowest amount of points  Level 2 Deficiency – Higher amount of points  Level 3 Deficiency – Even higher amount  Exigent Health and Safety Deficiency - Highest 17

18 CONDUCTING THE INSPECTION

 Relationship with inspector  2 people to perform inspection with inspector  Understand REAC Protocol  Maintain good relationship with inspector  Talk about common interest  Diversion Tactics  Have a copy of the compilation bulletin with you  Ask inspector to show you the definition of the deficiency  Carry a maintenance package with you 19

 Maintenance package  Light bulb  9V batteries  Screwdriver and pliers  Switch plates and outlet covers  Breaker blanks  Paperclip 20

21 SITE DEFICIENCIES

 If it’s there, it must function as it is designed to function.  Fencing – Perimeter and building 3 to 4 Deficiencies  Retaining walls Damaged or leaning 22

 Grounds ◦ Overgrown/penetrating vegetation ◦ Erosion/Rutting ◦ Ponding Site Drainage  Parking lots ◦ Cracks ◦ Ponding ◦ Potholes/loose material ◦ Settlement heaving 23

5/17/2011  Play Areas  Damaged play area  Broken Equipment/Benches  Walkways /steps  Cracks/settlement/ heaving  Spalling  Broken or missing handrail  4 or more steps  Refuse disposal  Damaged enclosure  Inadequate storage 24

 Graffitti  Level 1 – 1 place  Level 2 – 2 to 5 places  Level 3 – 6 or more  Litter – Excess  Have a groundsman picking up trash always in sight of the insp.  Mailboxes/Project Signs.  Sign damaged and cannot be read  Mailbox damaged or cannot lock 25

26 EXTERIOR

 If it’s there, it must function as it is designed to function.  Fire Escapes – Missing components or blocked  Foundation  Cracks/gaps  Spalling/exposed rebar  Lighting  Bulb or fixture broken/missing 27

 Roofs  Shingles  Vents  gutters  soffitts  Walls  cracks/holes  peeling paint  Caulking  chimney 28  Windows ◦ Broken ◦ Sills ◦ Bars ◦ Paint & Screens  Doors ◦ Hardware & frame ◦ Surface & screen ◦ Caulk

29 SYSTEM HITS

If it’s there, it must function as it is designed to function  Water  Leaking spigots  Misaligned flu  Missing T&P valves  Fire Protection  Sprinkler head  Fire extinguisher  Disposable  Rechargeable  Pull stations  HVAC System  Fuel leaks  Misaligned flu 30

 Sanitary System  Broken pipes  Clean out covers  Elevators  Not operable 31  Emergency power ◦ Lights don’t work  Electrical system ◦ Missing breakers ◦ Blocked ◦ Frayed Wiring ◦ Cover missing

32 UNITS

If it’s there, it must function as it is designed to function.  Blocked Egress -doors & windows-Biggest Inside Hit  Bathroom- faucets, tubs, drains, exhaust fans, toilets  Doors  Surface & Frame  Hardware  Floors  Carpet or tile  % is bad  Kitchen  Plumbing & Cabinets  Refrig. & Exhaust fan 33

 Windows  Hardware & Sill  Seal, lockability, broken glass  Stairs  Treads & Railing  Patio/porch/balcony  Laundry area  Dryer vent  Washer pipes and drain 34

35  Lighting ◦ Must work – carry bulb  Electrical ◦ Outlets ◦ Covers ◦ Switches

36 COMMON AREAS

 Maintenance Garage  Office  Clubhouse or Community Room  Exercise Room  Pool & Playground  If an area has utilities it is inspectable 37

38 Exigent Health & Safety

 Electrical Hazards  Emergency/Fire Exits  Air Quality  Flammable Materials- Gas lines, propane, charcoal fluid  Garbage Debris 39

 Hazards-Tripping, Sharp Edges  Infestation  Misaligned Flu in hot water heater or furnace  Will not enter a unit present with bed bugs 40

Smoke detectors that are inoperable or missing will be noted on the REAC report as a EH&S violation that has to be mitigated within 24 hours of inspection, but, it is NOT a scoreable item. 41

 Cable trip hazards are non scoreable. 42

43 APPEALING A SCORE

Technical Review- A technical review may be requested if during the inspection an objectively material error occurred that if corrected would result in an improvement of the properties overall score.  Building data errors  Unit count errors  Non existent deficiency errors  Received within 30 days 44

Database Adjustment  A request for database adjustment initiates a review of the results of a physical inspection. A database adjustment may be requested for circumstances affecting the inspected property that are out of the ordinary, reflect an inconsistency with ownership or are allowed by city state code. Received with 45 days 45

46 REAC REFERENCES

  Technical Assistance Center  DCD 2.3a Public Version User Guide  Compilation Bulletin  REAC Class in Washington, DC  Questions/Comments 47

48

49

What Category does a leaking water spigot fall into? a. Unit b. Site c. Systems d. Exterior 50

Screens are one of the major things to fix before a REAC inspection.  True  False 51

Broken glass found on the property is an exterior Deficiency  True  False 52

Foundation cracks are a relatively small hit on an inspection  True  False 53

A Blocked egress is the largest hit you can take inside of a unit  True  False 54

You have 48 hours to fix all Exigent Health and safety violations  True  False 55

A broken splash block falls into what category a. Unit b. Exterior c. Systems d. Site 56

Which of these is not an exigent health and safety violation a. Open breaker port b. Misaligned Water heater flu c. Missing outlet cover d. Massive hole in Bedroom wall 57

The deficiency “erosion” is only found by large rutting areas or large areas of soil being washed away?  True  False 58

There are 3 areas you can be cited for a deficiency on a Unit window  True  False 59

Playground benches are not inspectable.  True  False 60

Playground mulch or associated material is not inspectable.  True  False 61

All Breaker boxes must have doors  True  False 62

What is the occupancy % value that HUD is looking for to keep from inspecting vacant units? a. 84% b. 92% c. 77% d. 85% 63

Project signage must be readable from at least 20 ft away or it is deficient  True  False 64

Graffiti, Level 3 must have at least 4 areas of occurrence.  True  False 65

If you remove a broken swing from the playground area, then you cannot be cited for it  True  False 66

All fire extinguisher must be tagged by a certified fire protection company  True  False 67

If a retaining wall is damaged but is not a safety risk then there is no deficiency  True  False 68

Trip Hazards only applies to concrete sidewalks  True  False 69

An exterior GFI is a large electrical deficiency  True  False 70

If a bed is blocking 1 of two windows in a bedroom, it is still a blocked egress  True  False 71

If you remove an A/C from a window and the window will not stay open by itself, it is considered a blocked egress.  True  False 72

It is not possible to receive a deficiency in a breaker box where all of the breakers and/or blanks are present  True  False 73

What is the distance according to HUD that a discharge tube on a water heater can be from the floor. a. 12 inches b. 24 inches c. 20 inches d. 18 inches 74

Fire pull stations can be inspected by the property  True  False 75

On an exterior wall, a crack or gap that is more than 3/8 inches wide, 1/8 inch deep or 6 inches long is still a relatively small hit in terms of points.  True  False 76

Garbage inside of a unit is not a deficiency  True  False 77

A lamp in front of a bedroom window constitutes a blocked egress  True  False 78

GFI’s that deliver voltage but do not test are still considered a deficiency  True  False 79