HVAC 7ab CNST 305 Environmental Systems 1 Dr. Berryman

Slides:



Advertisements
Similar presentations
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2J: Building.
Advertisements

Heating and Air Conditioning I
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
eQuest Quick Energy Simulation Tool
Five star hotel in Nablus
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
“Do not take anyone’s advice as to how this building should be assembled.”
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
The Three Tiered Philosophy
Infiltration/Ventilation HVAC 7a CNST 305 Environmental Systems 1 Dr. Berryman.
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Environmental Controls I/IG Lecture 12 Cooling Loads Cooling Degree Hours Energy Performance Ratings Annual Fuel Consumption Lecture 12 Cooling Loads Cooling.
Conduction Cooling Loads
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Heat Loss HVAC CNST 305 Environmental Systems 1 Dr. Berryman.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Energy Conserving Alternatives HVAC 15a CNST 305 Environmental Systems 1 Dr. Berryman.
Smart energy in Europe. Heat losses and gains Termografhy of a building.
Passive Solar House A passive solar house is heated by the sun’s energy.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Windows Do not open or close all windows and doors at the same time. Optimise the ventilation by experimenting with opening different windows instead.
Why we need to calculate heating load ?
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
ENERGY CONSERVATION BUILDING CODE – 2006 PRESENTATION BY VP GUPTA PRINCIPAL CHIEF ENGINEER (ELECTRICAL), BSNL CHENNAI.
MAIN ENTRANCE SOUTH EAST VIEW NORTH EAST VIEW.
Objectives Review heating and cooling load calculation Practice the calculation of cooling load Learn about heating systems.
Ductless Heat Pumps Sizing Example
Building Simulation. BMEABMEA uilding odeling nergy nalysis.
HVACR416 - Design Heat Loss / Heat Gain Part 2. External Loads The greatest external load is the sun. The suns heat can get into a building in one of.
1)Does ECJ have a larger heating or cooling load? A.Heating B.Cooling.
Objectives Lean about energy transport by air Calculate Cooling and Heating loads Solve 1-D conduction Design whether condition Use knowledge of heat transfer.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
0 Load Calculation Manual Output : 1. Screen Outputs (Results, Pareto Chart, Hourly Estimation) 2. Optional Outputs (*CLTD.txt, *TETD.txt) 3.
Cooling And Heating Load Calculations
EXAMPLE EXERCISE CALCULATING HEAT LOSS & HEAT GAIN  Several exhibits in the class packet are necessary to understand the entries into the Heat Loss /
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
Heat Gains into a Building
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Development of a new Building Energy Model in TEB Bruno Bueno Supervisor: Grégoire Pigeon.
Design What is the first step in designing a high-performance building? Would it be: Identify synergies Select the correct HVAC system Design around human.
Chapter 8: The Cooling Load Cooling load is the rate at which energy must be removed from a space to maintain the temperature and humidity at the design.
Technical Seminar on Application and Technical Specification June 2016
Heat Loss and Gain Civil Engineering and Architecture
The Heat Balance Method
Technology in Architecture
HEAT GAIN CALCULATIONS
Maria’s Restaurant Chapter 1 Section 3
Heat gain in buildings: Other factors
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Heat Loss and Gain.
Conduction Cooling Loads
Introduction – Who am I? Environmental Project Manager – Trident Technical College Mechanical Engineer Licensed Builder South Carolina Accredited Commercial.
Technology in Architecture
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Technology in Architecture
Why we need to calculate heating load ?
Technology in Architecture
Lecture Objectives Finish the cooling load example
Technology in Architecture
Objectives Review heating and cooling load calculation
Quiz First 10 minutes of the class.
Announcements Exam 1 Next Class (Thursday, March 14th):
PROJECT NAME: HVAC AND MECHANICAL SYSTEMS DESIGN
Lecture Objectives Learn about Cooling Load Calculation
Maria’s Restaurant Chapter 1 Section 3
Presentation transcript:

HVAC 7ab CNST 305 Environmental Systems 1 Dr. Berryman Heat Gains HVAC 7ab CNST 305 Environmental Systems 1 Dr. Berryman

Cooling Load Components roof lights partition wall people infiltration glass solar equipment glass conduction exterior wall floor

Sensible and Latent Gains load latent load cooling load components conduction through roof, walls, windows, and skylights solar radiation through windows, skylights conduction through ceiling, interior partition walls, and floor people These load components contribute sensible and/or latent heat to the space. Conduction through the roof, exterior walls, windows, skylights, ceiling, interior walls, and floor, as well as the solar radiation through the windows and skylights, all contribute only sensible heat to the space. The people inside the space contribute both sensible and latent heat. Lighting contributes only sensible heat to the space, while equipment in the space may contribute only sensible heat (as is the case for a computer) or both sensible and latent heat (as is the case for a coffee maker). Infiltration generally contributes both sensible and latent heat to the space. The cooling coil has to handle the additional components of ventilation and system heat gains. Ventilation contributes both sensible and latent heat to the coil load. Other heat gains that occur in the HVAC system (from the fan, for example) generally contribute only sensible heat. lights equipment/appliances infiltration ventilation system heat gains

Time of Peak Cooling Load east-facing window roof heat gain One of the more difficult aspects of estimating the maximum cooling load for a space is determining the time at which this maximum load will occur. This is because the individual components that make up the space cooling load often peak at different times of the day, or even different months of the year. For example, the heat gain through the roof will be highest in the late afternoon, when it is warm outside and the sun has been shining on it all day. Conversely, the heat gain due to the sun shining through an east-facing window will be highest in the early morning when the sun is rising in the east and shining directly into the window. Determining the time that the maximum total space cooling load occurs will be discussed later in this clinic. 12 6 12 6 12 mid a.m. noon p.m. mid

Sunlit Surfaces sun solar angle changes throughout the day rays Most exterior surfaces of a building, however, are exposed to direct sunlight during some portion of the day. Solar heat energy is generated by the sun and radiated to earth. Radiant heat is similar to light, in that it travels in a straight line and can be reflected from a bright surface. Both light and radiant heat can pass through a transparent surface (such as glass), yet neither can pass directly through an opaque or non-transparent surface (such as a brick wall). When the sun’s rays strike an opaque surface, however, a certain amount of radiant heat energy is transferred to that surface, resulting in an increase in the surface temperature. The amount of heat transferred depends primarily on the color and smoothness of the surface, and the angle at which the sun’s rays strike the surface. When the sun’s rays strike the surface at a 90º angle, the maximum amount of radiant heat energy is transferred to that surface. When the same rays strike that same surface at a lesser angle, less radiant heat energy is transferred to the surface. The angle at which the sun’s rays strike a surface depends upon the latitude, the time of day, and the month of the year. Due to the rotation of the earth throughout the day, and the earth orbiting the sun throughout the year, the angle at which the sun’s rays strike a surface of a building is constantly changing. This varies the intensity of the solar radiation on an exterior surface of a building, resulting in a varying amount of solar heat transferred to the surface throughout the day and throughout the year. As mentioned previously, the assumption that the surface is completely shaded does not account for the additional heat gain that occurs when the sun shines on a surface. Solar heat, therefore, must be considered, as it constitutes an important part of the total cooling load of most buildings.

Time Lag solar effect 12 6 12 6 12 time lag B A mid a.m. noon p.m. mid The walls and roof that make up a building’s envelope have the capacity to store heat energy. This property delays the heat transfer from outdoors to the space. The time required for heat to be transferred through a structure into the space is called the time lag. For example, the heat that is transferred through a sunlit wall into a space is the result of sunlight that fell on the outer surface of the wall earlier in the day. Curve A shows the magnitude of the solar effect on the exterior wall. Curve B shows the resulting heat that is transferred through the wall into the space. This delay in the heat gain to the space is the time lag. The magnitude of this time lag depends on the materials used to construct the particular wall or roof, and on their capacity to store heat. 12 6 12 6 12 mid a.m. noon p.m. mid

Storage Effect (thermal lag)

Conduction – Sunlit Surfaces A factor called the cooling load temperature difference (CLTD) is used to account for the added heat transfer due to the sun shining on exterior walls, roofs, and windows, and the capacity of the wall and roof to store heat. The CLTD is substituted for T in the equation to estimate heat transfer by conduction. CLTD BH = U  A  T

Roofs Based on: Solar radiation at 40o lat on July 21 Dark surface OA 95oF Outdoor mean of 85oF Daily Range of 21oF No Ventilation

CLTD Correction - Roof CLTDcorr = [(CLTD + LM)k + (78 – tR) + (tO – 85)]f to = OA – (DR/2)

Latitude Month Adjustment

Roof Types Select closest construction Compare U values Weight Construction Compare U values Additional insulation Use a CLTD whose roof weight and heat capacity are approximately the same Find peak gain during the day For each R-7 above selected roof type Move value 2 hours later 29oF is the lowest adjustment value you can use

Sunlit Walls Based on: Solar radiation at 40o lat on July 21 Dark surface OA 95oF Outdoor mean of 85oF Daily Range of 21oF

Wall Groups Select closest wall group Compare U-values Move up one wall group for each R-7 G F E D C B A Each R-7

Correcting CLTD - Walls CLTDcorr = (CLTD + LM)k + (78 – tR) + (tO – 85) to = OA – (DR/2)

EXAMPLE Roof Calculation Find peak cooling load: Given: New Orleans, LA OA DB=93oF WB=77oF IA 77oF 40% RH 30o N. Latitude – June 22 Daily Range of 16oF 5000 SF light colored steel sheet roof w/ drop ceiling – rural area No attic ventilation Rtotal = 21 Closest roof type: 1 Peak: 1500 hrs CLTDuncorr: 78oF EXAMPLE Correct for insulation: R=7.5 vs 21 (+4 hrs) CLTDuncorr: 42oF Correct CLTD: next slide

CLTD Correction - Roof CLTDcorr = [(CLTD + LM)k + (78 – tR) + (tO – 85)]f 42oF 2oF 0.5 77oF 85oF 1.0 CLTDcorr = 23oF tO = (OA – (DR/2) Average outside temperature 93oF 16oF tO = 85oF Heat gain through roof: BH = U  A  CLTD (1/21)(5000)(23oF) = 5476 BH

EXAMPLE Wall Calculation Determine Wall Group: Given: New Orleans, LA OA DB=93oF WB=77oF IA 77oF 40% RH 30o N. Latitude – June 22 Daily Range of 16oF 12x100’ light colored metal curtain wall – rural area – West facing Rtotal = 19 Type G Metal Curtain Wall EXAMPLE Correct for insulation: R values 5.6 - 12.3 vs 19 (up 1 wall group) Use Type F Wall Group Correct CLTD: next slide

CLTD Correction - Walls CLTDcorr = (CLTD + LM)k + (78 – tR) + (tO – 85) 28oF 0oF 0.65 77oF 85oF CLTDcorr = 19.2oF Heat gain through wall: BH = U  A  CLTD (1/19)(12’ x 100’)(19.2oF) = 1213 BTUH

Sunlit Glass BH = solar gain + conduction sun rays reflected energy transmitted glass window conduction solar gain (radiation) BH = solar gain + conduction

Glass - Conduction BHconduction = U  A  CLTD Based on: IA = 78oF OA = 95oF Daily Avg – 85oF DR = 20oF CLTDcorr = CLTD + (78 – tR) + (tO – 85) Calculate CLTDcorr like roof/walls

Solar Heat Gain Factors Direction that the window faces Time of day Month Latitude Construction of interior partition walls Type of floor covering Existence of internal shading devices The solar heat gain factors are used to estimate the rate at which solar heat energy radiates directly into the space, heats up the surfaces and furnishings, and is later released to the space as a sensible heat gain. Similar to CLTD, the SCL factor is used to account for the capacity of the space to absorb and store heat. The value of SCL is based on several variables, including the direction that the window is facing, time of day, month, and latitude. These four variables define the angle at which the sun’s rays strike the surface of the window. The next two variables, the construction of the interior partition walls and the type of floor covering, help define the capacity of the space to store heat. This affects the time lag between the time that the solar radiation warms up the space furnishings and the time that the heat is released into the space. The last variable, whether or not internal shading devices are installed, affects the amount of solar heat energy passing through the glass. The 1997 ASHRAE Handbook—Fundamentals contains tables of SCL values for common space types, based on combinations of these variables. Table 7 [Table 8] * is an excerpt from the handbook and includes SCL factors for a space type similar to the one in our example. The space in our example is classified as Space Type A. The data in this table is based on the 21st day of July and 40º north latitude. At Hour 17, the SCL for the west-facing windows in our example space is 192 Btu/hr•ft2 [605 W/m2]. * These tables can be found in the “Notes Page” view of Slide 96.

Types of Shading Devices interior blinds exterior fins

Glass – Solar Gain BHglass = SHGF x A x SC x CLF where, The equation used to predict the solar heat gain (radiation) through glass is: BHglass = SHGF x A x SC x CLF where, BH = heat gain by solar radiation through glass, Btu/hr SHGF = solar heat gain factor, Btu/hr•ft2 A = total surface area of the glass, ft2 SC = shading coefficient of the window, dimensionless CLF = cooling load factor, dimensionless Installing internal shading devices, such as venetian blinds, curtains, or drapes, can reduce the amount of solar heat energy passing through a window. The effectiveness of these shading devices depends on their ability to reflect the incoming solar radiation back through the window, before it is converted into heat inside the space. Light-colored blinds or drapes lined with light-colored materials, therefore, are more effective than dark-colored shading devices. The type of internal shading device used affects the shading coefficient of the window-and-shading-device combination.

SHGF Solar energy through fenestration for Sunlit Glass* *use N(shade) for non-sunlit glass

SC 82% Solar Reduction Blinds or drapes absorb the solar energy before it can strike the floor causing a rapid response in the cooling load

CLF Without interior shading When shading is absent: Energy is absorbed by the more massive elements of the space Heavier construction = larger heat gain delay

CLF with interior shading Reduction in the amplitude of the solar heat gain due to the constructions

EXAMPLE Window Calculation GIVEN: New Orleans, LA OA DB=93oF WB=77oF IA 77oF 40% RH 30o N. Latitude – June 22 Daily Range of 16oF Light venetian blinds 30 40 DH Clear Glass R = 2 West facing at 1400 HRS Conduction BH = U  A  CLTD EXAMPLE CLTDcorr= 14oF+(78oF–77oFF) + (85oF–85oF) (½)(3 x 4)(15oF) = 90 BH Solar Gain BH = SHGF x A x SC x CLF (214 BH)(12)(0.58)(.53) = 790 BH BHtotal = 880

Lighting BHlight = watts  3.41  ballast factor  CLF 1 watt = 3.4 BTUH BHlight = watts  3.41  ballast factor  CLF BH = sensible heat gain from lighting, Btu/hr [W] Watts = total energy input to lights, W 3.41 = conversion factor from W to Btu/hr Ballast factor = 1.2 for fluorescent lights, 1.0 for incandescent lighting CLF = cooling load factor, dimensionless Heat generated by lights in the space is a significant contribution to the cooling load. For example, a 120-watt light fixture generates 410 Btu/hr [120 W] of heat–approximately the same amount of heat gain from an average office worker. Additionally, when estimating the heat gain generated by fluorescent lights, approximately 20% is added to the lighting heat gain to account for the additional heat generated by the ballast. The equation used to estimate the heat gain from lighting is: Q = watts x 3.41 x ballast factor x CLF [Q = watts x ballast factor x CLF] where, Q = sensible heat gain from lighting, Btu/hr [W] Watts = total energy input to lights, W 3.41 = conversion factor from W to Btu/hr (when using I–P units) Ballast factor = 1.2 for fluorescent lights, 1.0 for incandescent lights CLF = cooling load factor, dimensionless Similar to the sensible heat gain from people, a cooling load factor (CLF) can be used to account for the capacity of the space to absorb and store the heat generated by the lights. If the lights are left on 24 hours a day, or if the air-conditioning system is shut off or set back at night, the CLF is assumed to be equal to 1.0.

Lighting Estimates

Light CLF Dependent on: 1) Occupied Hours and 2)Design Values

Space versus Plenum Loads roof lights plenum exterior wall return air ceiling Space versus Plenum Loads In the previous examples used throughout this clinic, we have assumed that the spaces do not have a ceiling plenum. The plenum is the space between the ceiling and the roof. When a building has a plenum, all heat gain through the roof affects the plenum instead of the occupied space. Additionally, because a portion of the exterior wall is adjacent to the plenum, the heat gain through that part of of the wall affects the plenum. Finally, in many types of lighting systems, a portion of the heat generated by the lights is transferred directly into the plenum instead of into the space. The plenum is not air conditioned, but in this example the return air from the space passes through the plenum on the way back to the air handler. Some of the heat gain to the plenum is absorbed by this return air, increasing the temperature of the air returning to the air handler. The heat gain in the plenum, however, also creates a temperature difference between the plenum and the space, which results in some of this heat being transferred by conduction, through the ceiling and into the space. The conduction heat gain through the roof, the conduction heat gain through the top section of the exterior wall, and 30% (assumed) of the heat generated by the lights is transferred to the plenum instead of to the space. While some of this heat is absorbed by the return air most is transferred through the ceiling into the space. This heat transfer between the plenum and the space does affect the space sensible load, but it does not affect the coil load. This is because any heat that is not transferred to the space is absorbed by the return air and must be eventually removed by the cooling coil. The affect of the plenum reduces the total space sensible load. This results in 21% less airflow required to condition this space. A heat balance can be performed to determine how much heat that originally entered the plenum actually enters the space. This heat balance is an iterative process, because the conduction heat transfer between the plenum and the space depends on the temperature of the air in the plenum and the quantity of return air passing through the plenum. A computer program can perform these calculations much faster than they could be done by hand, due to the number of iterations required to achieve accurate results. Heat absorbed by Return Air

CLF Design Values (Coefficients)

Lighting Calculation = 9821 BH BHlight = watts  3.41  ballast factor  CLF GIVEN: Church w/ 11:00 service Fluorescent lighting Lights on 0800 Lights off at 1600 Medium Ventilation Rate Supply/return through floor Ceiling space not vented Ordinary furniture w/ no carpet 6” Concrete floor 40’x80’ (1Wx3200SF)(3.41BH/W)(1.2)(0.75) Watts per SF = 1w Ballast factor = 1.2 Design value of “a” = 0.68 Design value of “b” = B CLF = 0.75 = 9821 BH

People

Equipment - Office

Equipment -Restaurant

Heat Gain in Ductwork If insulated – Add 1-3% depending of the extent of the duct work Not insulated – Add 10 – 15% depending on extent of duct work or climate (best to calculate gain by conduction) Another source of heat gain in the system may be heat that is transferred to the conditioned air through the walls of the supply and return ductwork. For example, if the supply ductwork is routed through an unconditioned space, such as a ceiling plenum or an attic, heat can be transferred from the air surrounding the duct to the supply air. Supply ductwork is generally insulated to prevent this heat gain and the associated increase in temperature of the supply air. An increased supply air temperature requires a greater amount of supply air to maintain the desired space conditions, resulting in more fan energy use. Insulation also reduces the risk of condensation on the cool, outer surfaces of the duct. Return ductwork, on the other hand, is generally not insulated unless it passes through a very warm space. Any heat picked up by the return air is generally heat that would have eventually entered the space as a cooling load. Therefore, the cooling load caused by this heat gain to the return air is not wasted. For the example used in this clinic, we will assume that fan heat gains and other system heat gains are negligible. Duct leakage – If outside of conditioned space add 5% BH = U  A  T

System Heat Gains Fan Motor Fan Blades Duct Friction air handler There may be others sources of heat gain within the HVAC system. One example is the heat generated by fans. When the supply fan, driven by an electric motor, is located in the conditioned airstream, it adds heat to the air. Heat gain from a fan is associated with three energy conversion losses. Fan motor heat is due to the energy lost in the conversion of electrical energy (energy input to the motor) to mechanical energy (rotation of the motor shaft). It is dissipated as heat from the motor and is represented by the inefficiency of the motor. fan motor heat gain = power input to motor  (1 – motor efficiency) If the fan motor is also located within the conditioned airstream, such as inside the cabinet of an air handler (as shown in Figure 51), it is considered an instantaneous heat gain to the airstream. If it is located outside the conditioned airstream, it is considered a heat gain to the space where it is located. Fan blade heat gain is due to the energy lost in the conversion of mechanical energy to kinetic energy (moving of the air). It is dissipated as heat from the fan blades, it is considered an instantaneous heat gain to the airstream, and it is represented by the inefficiency of the fan. fan blade heat gain = power input to fan  (1 – fan efficiency) Finally, the remaining (useful) energy input to the fan, the energy used to pressurize the supply duct system, is eventually converted to heat as the air travels through the ductwork. For simplicity, most designers assume that this heat gain occurs at a single point in the system, typically at the location of the fan. duct friction heat gain = power input to fan  fan efficiency Reference: 1997 ASHRAE Handbook–Fundamentals, Chapter 28, page 28.16 fan motor heat gain = power input to motor  (1 – motor efficiency) fan blade heat gain = power input to fan  (1 – fan efficiency) duct friction heat gain = power input to fan  fan efficiency

Sample Form Heat Gain Space Internal Plenum System Wall,Roof Floor, Glass Ventilation Infiltration Internal Lights People Equipment Plenum Duct gain Duct leakage System Motor, Fan

Heat Gain Assignment Use Dinky Office Building Calculate total heat gain using your building design Turn in (in order): Assumption sheet Hand calculations of room 101 Excel spreadsheet – Heat gain Floor plan w/ building orientation Corrected Wall Section Corrected Heat Loss calculations Window/Door data sheets

“Rules of Thumb”

Balancing the System 12,000 BTUH / Ton CFM = T RSH 1.08 x

Next Time Computerized Load Calculations Wrightsoft Right-N