Design Ash finished electric hybrid tracing to connector fields –Changes to allow for HCC-less and HCC running on one hybrid awaiting final confirmation.

Slides:



Advertisements
Similar presentations
Module Production T. Bowcock. News Since Last Meeting Engineering Design Review (20-21 st April) –Mechanics including module and fixtures –Components.
Advertisements

23-Aug-2005 VELO Production UCD VELO Module Production at Liverpool T. Bowcock.
Status of Sensor and Hybrid Production LHCb Zurich Week T. Bowcock.
Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Stave Vacuum Tool Tim WP4 Face to Face Liverpool, 13/11/14.
Stave Hybrid Status Ashley Greenall 1. Current Status Current build of hybrids (Version 3) distributed to 6(+1) sites: Cambridge, DESY, Freiburg, LBL,
ATLAS Module building at Glasgow
Building a Pressure/Temperature Weather Station (Sensor Pack) AEM 1905, Fall 2008.
Hybrid assembly at Glasgow. Placing ASICs Arrange 20 ASICs in ASIC tray with strip bond pads facing outwards – ASICs to be used in ‘Cat A’ sample boxes.
Tracker Week – UCSB Gantry Status – July 20, 2004 – Dean White 1 Gantry Report University of California Santa Barbara UCSB Gantry Team: Andrea Allen Dave.

TOOL: Radial Arm Saw NEXT STEP: Radial Arm Saw RESULTS: Finish Top Apron Pieces at 9” L x 4” W x ¾ “ Th PROJECT Square Plant Stand PART Top Apron # NEEDED.
VELO upgrade electronics – HYBRIDS Tony Smith University of Liverpool.
Tooling and assembly of US stavelet at Berkeley S. Díez Cornell, C. H. Haber, M. Defferrard, R. Witharm Sept 6th, 2012 Berkeley mechanical meeting, 5th-7th.
March 20, 2001M. Garcia-Sciveres - US ATLAS DOE/NSF Review1 M. Garcia-Sciveres LBNL & Module Assembly & Module Assembly WBS Hybrids Hybrids WBS.
ATLAS Tracker Upgrade Stave Collaboration Workshop Oxford 6-9 February 2012 ABC 130 Hybrid.
Received new "130nm" jigs from Liverpool and after the "module workshop" 25/3/15 at Liverpool and ready to make dummy modules New jigs need to be slotted.
WP3 Meeting 21/05/ Liverpool Status: Thermo-Mechanical Hybrids Have now received a full complement of 240 Thermo-Mechanical Hybrids from Stevenage.
17/06/2010UK Valencia RAL Petals and Staves Meeting 1 DC-DC for Stave Bus Tapes Roy Wastie Oxford University.
Slide 1Susanne KyreTracker week, October 2005 TEC/TOB bias bonds Susanne Kyre University of California, Santa Barbara.
Left side Right side Note pad Roll block. The Plan.
G.Barber KEK Test Beam Update, Berkeley 9 Feb KEK Test Beam – Tracker Progress Contents:- Station Space Frame Light Guide Map Station Connectors.
Stave Module Status Tony Affolder The University of Liverpool On behalf of cast of thousands… ATLAS Upgrade Week November 10,
12 Aug 2013 ATLAS Tracker Upgrade Status Birmingham 1 - Small vacuum pump holding hybrid flat on panel (which it is ‘strong enough’ to do) - Since picture.
Estimated schedule, costs and number of ABC130 needed Tony Affolder.
16/04/20031PNPI / LHCb Muon EDR Wire Pad Chambers PNPI design for regions R4 in Stations M2,M3,M4  4 gas gaps of 5mm±70µm;  Active area: 1224x252.8 mm².
PS Module Gluing Tests USCMS Outer Tracker Workshop Ulrich Heintz, Meenakshi Narain, Bill Patterson, Sinan Sagir, Adam Lanman, Eric Spencer, Juan Trenado,
Baby MIND coil modules assembly the aluminium folded strip solution 1 Alexey, Philippe, Gabriella, Helder, Herman Baby Mind Magnet CERN June.
Strip Stave cores Stephanie Yang ATLAS upgrade Oxford activities, January 2015.
Petalet-Stavelet; 13 July Birmingham Update Gluing to mechanical sensor with Epolite (as reported earlier). 1 st hybrid – too much glue on stencil.
Birmingham Update Module bonding (Sam and Simon) Great difficulty bonding on to patterned glass ASICs. (OK on sensor). After 1 st two rows of bonds, abandon.
Thermo-mechanical petal status Sergio Díez Cornell 23Jan 2015.
Fred Doherty Module Work Fred Doherty. Stave Module Building Hybrid Bonding Bonding table for the BJ820 still in workshop Modified working height of the.
Hybrid Mechanical/Thermal Design Ray Thompson / Manchester FP420 meeting Torino 11/12 July 06.
Hybrid panel heated plate study Currently the curing of the ASIC glue for the hybrid panels are done at room temperature. This is a study to determine.
Stave Hybrid/Module Status. Modules Stave Module Building 2 Mechanical Chip Gluings Mechanical Wirebonding Electrical Chip Gluings Electrical Wirebondings.
David Bailey Gluing. Silicon /pcb assembly Previously Using Sony Robot and precision dispenser Have established acceptable glue dot parameters Dot electrical.
Stave C channel side closeout gluing jig S Yang WP4 monthly meeting at Liverpool University 26 th March 2014.
G.Barber/Peter Cooke: Mechanical Design Update Imperial 22 July Mechanical Update for Tracker workshop Contents:- New Station Layout Light Guide.
1 PFDPU Mechanical Packaging PEER REVIEW MAVEN PFDPU Particle and Fields Data Processing Unit Mechanical Packaging and Design Overview May 09, 2011 Bill.
Gluing, measuring and shearing Heated plate curing Is the process feasible? Tests with 130nm hybrids Measure resulting glue thickness Determine the shear.
G.Barber Mice Tracker Mechanical Progress Tracker Mechanical Progress Contents:- Station Space Frame Station Layout Light Guide Map Connectors Patch.
WP3_Bham; 29May 2014; John Wilson1 Heated plate curing Tests with 130nm hybrids and glass ASICs the glue thickness is controllable. i)Room temp curing.
130 nm Stave Module Status Slides from many sources 1.ABC130 Issues/Investigation 2.Module Design 3.DC-DC converter work 4.Plans/schedule after ABC130.
A.Cheremukhin (JINR, Dubna) CMS Preshower PRR, July 5-6, 2001, CERN1 Micro-module assembly -  -module elements - alignment of the silicon sensors to the.
Gluing trials continuing: Loctite is favourite (for Dispensemaster) Bonding: exercising the machine; practising in laying down patterns (Simon and.
Module Assembly Jig Status Cambridge and DESY came to Liverpool Nov. 15 th -16 th for training on module assembly – A complete jig set was sent back with.
Hybrid and Module Status 1. Hybrid Delivery First hybrids over-etched and shrunk due to changes in design and mistakes in manufacturing – Shrinkage for.
WP3_Bham; 15May 2014; John Wilson1 Heated plate curing Tests with 130nm hybrids and glass ASICs i) Room temp curing the glue thickness is controllable.
Module Radiation Length. Goals Estimate the expected radiation length of a module, based on the design and measurements on as-built modules Determine.
DOE CD-2/3a Review of the BTeV Project – December 14-16, BTeV Pixel Detector Pixel Module Assembly and Half-Plane Assembly Guilherme Cardoso James.
Build A Motor You must follow the directions step-by-step!
Thoughts about PS module assembly Ulrich Heintz, Meenakshi Narain, Bill Patterson, Eric Spencer, Juan Trenado Brown University, Providence 4/16/2015Heintz,
Infrastructure & issues and solutions for ATLAS Upgrade Hybrid/Module strip bonding Fred Doherty, Joe Ashby, Fiona McEwan & Calum Gray ATLAS Upgrade Module.
ATLAS pixel module assembly flow
T. Bowcock University of Liverpool
→ need to guide UV light into gap; also beware temp effects
Glue curing studies (contd)
Ladder Assembly All tools and jigs produced Glue dispensing works
Sector 002 Assembly status report
Hybrid Issues.
Ladder Assembly All tools and jigs produced Glue dispensing works
ITK Strip Module Meeting; 12st October 2015
Constructional requirements from ITk-Strips
Gluing jigs for Demonstrator
Equipment for Assembly – UK Experiences
ATLAS Upgrade Module Bonding Trials Using Glass Asics
ATLAS ITK WP3 WP3 Bi-weekly meeting
Module Production in Brussels
Pixel module assembly tooling
Presentation transcript:

Design Ash finished electric hybrid tracing to connector fields –Changes to allow for HCC-less and HCC running on one hybrid awaiting final confirmation of HCC footprint Should come next week Power board work by Sam continuing –Toroidal DC-DC and pararrel power boards ready for submission –Flat coil next on list –SP board (with SPP) needs details from Mitch

Assembly Results So Far Very positive results in gluing ASIC to hybrids and hybrids-to- sensor –One solid row of epoxy under ABC130, one dotted row under thermistor, HCC and hybrid-to- tape bonds ~50% epoxy coverage with  m thickness Performed pickup trials with ABC130. –No visible marking under microscope Slide 2

Minor Jig Issues All worked as well as expected but: –ASIC glue stencil tended to rock on single ASIC column, pumping too much glue onto ASIC –Epolite (sensor-to-hybrid) epoxy tended to push AWAY the hybrid from the sensors Previously we were worried that the glue would pull the hybrid TOWARDS the sensors Expect that skimming glue onto back of hybrid with stencil would also bend hybrid and pump extra glue between stencil and hybrid Chip Pickup Tool Glue Stencil ABC130 Chip Pickup Tool Hybrid Sensor Epolite Slide 3

Chip Stencil Fix Glue a plastic bar onto chip stencil which will touch the chip pickup tool –This has been trialled successfully with 3 pickup tools and two stencils Chip Pickup Tool Glue Stencil ABC130 Plastic Bar Slide 4

Chip Pickup Tool Fix We want to put a removable bars on chip pickup tool to push on outside of hybrid –Under design and prototyping now –Will add a groove into chip pickup tool to locate and hold bar Needs to avoid HCC region for both types of hybrids Slide 5 Chip Pickup Tool Hybrid Sensor Epolite Plastic Bar Bar would locate in the two dowel holes and the additional slot

Assembly Future Plans (I) Once pickup tool bar shown to stabilize unsupported hybrid will make metal stencil to screen Epolite onto back of hybrid –Without bar, epoxy will pump between stencil and hybrid, binding hybrid to it. Stencil would be for one hybrid (this shows paper stencil onto sensor for two hybrids Slide 6

Assembly Future Plans (II) One of the reasons to change the hybrid pickup tool face to anodized AL is improve the uniformity and stability –Ideally, all tools will be “identical” and therefore interchangeable In current ABC250 tooling, the same tool has to be used for gluing ASICs-to-hybrids and hybrids-to-sensors We plan to test this in the next set of hybrid and module assemblies –Will exchange the tooling between ASIC and hybrid gluing As first test of this, we can exchange jigs after ASIC gluing and curing and the vacuum does not leak and the tool legs all touch Slide 7

Bonding Experience So far, so good –Not complaints from anyone Every attempt successful –~>6 chip cards, 5 hybrids, 1 modules –Much easier than 250 nm (both hybrid and module) Biggest unexplored issue is the best bonding parameters for the ABC130 metal –Much softer/thicker than ABC25 (more like FEI4) First chip on boards bonded ok and systematic studies started at Liverpool Slide 8

Jigs Distribution Plans A set of jigs to do one hybrid sent to Birmingham already to continue accelerated silver epoxy curing studies Hope to have a jig sets for Cambridge, Glasgow, UCSC, and LBL for hybrids for end of February or beginning of March –ASIC glue stencil, ASIC trays, pickup tools, 8 way jig and module assembly tools from Liverpool Only one pickup tool per site until bar for pickup tool understood –Module testing plates from LBL –Other 2-3 pickup tools per site and module glue stencil will follow with successful module trialling Slide 9

Component Distribution/Status Orders of 10 panels (2 per site) due back this week (will be before end of February Plenty (~150) glass and (~100) mechanical sensors More plain glass ASICs need to be diced (~ ); starting at Glasgow Only component we could be short of is patterned AL glass ABC130s from CNM –Needed for both hybrid and module bonding trials Slide 10 Is there an interest in the community for another AL glass ABC130 submission? Glass ASICs from CNM TM hybrids from Stevenage Mechanical Sensor from HPK

Wish list We would want a spectrum analyser for power board work (£3.5k) –Might be able to borrow the B180 unit For submissions, we will need: –£5k for electrical hybrids (40) –£~1k for power board submissions, frames, aux. boards, etc. –£~2k for AL patterned ASICs We assume next mech and elecrical hybrid submission would get billed after Q1 2014