ARC FLASH ANALYSIS.

Slides:



Advertisements
Similar presentations
Subcontractor Electrical Safety & NFPA 70E
Advertisements

NFPA 70E® 2012….. What's New and What do I Need to Know?
LIMITED APPROACH BOUNDARY
Murray State University
Arc Flash Boundary Qualified Persons, Safe Approach Distance. Determine the arc flash boundary and, if the boundary is to be crossed, appropriate arc-rated.
 ELECTRICAL SAFETY Gerald P. Robinson Jr., P.E. – Hatch Mott MacDonald.
Electrical Safety In The Workplace
Arc Flash & Data Centers
Finding a Common Thread… Presented by: Paul Pinto, National Accounts, Protective Apparel ARC Flash Protection, 70E and PPE.
ELECTRICAL SAFETY FOR RADIOLOGICAL CONTROL TECHNICIANS
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
San Bernard Electric Cooperative, Inc. Arc Flash Assessment.
Practice Statement The effective use of Isolate and Insulate equipment and procedures to provide the necessary level of safety when performing Live Line.
When working on or near electricity or electrical equipment you must be trained in & use Electrical Safety Related Work Practices NFPA.
Applying the 2012 NFPA 70E Arc Flash Standard
Joe Cobb Crawford, P.E.,C.E.M. Crawford Engineering Services
SKM Power*Tools for Windows
Arc Flash Hazards Construction Safety Association of Ontario
Techtric Enginering Ltd.
ELECTRICAL SAFETY SUB GROUP COMPENSATORY ARC FLASH CONTROLS Greg Christensen July 16, 2014.
Arc Flash Energy & Protection Presented by EWB Engineering (Electrical Engineers)
NFPA 70E 2015 & OSHA Update – Maximize Your Options
Electrical Safety Training
Introduction to Arc Flash
Utilizing Only Qualified Persons for Electrical Work can Reduce Risk Presented by: Dennis K. Neitzel, CPE Director Emeritus AVO Training Institute, Inc.
INJURY PREVENTION ARC FLASH REGIONAL SAFETY MEETING.
Electric Arc-Flash Injury Reduction Program Herman O. Kemp Electrical Safety Consultant Safety Program Consultants, LLC.
“Standard for Electrical Safety in the Workplace”
arc flash basics The International Facilities
What is Arc Flash? Arc flash is a short circuit through air that flashes over from one exposed live conductor to another conductor or to ground. Arc flash.
Arc Flash Regulations & Requirements Updated 12/07 Welcome.
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Construction Workforce Training Center
Qualified Persons Working On Or Near Energized Equipment
Electrical Safety In The Workplace
Occupational Safety and Health Course for Healthcare Professionals.
Electrical Safety: Are you Prepared?
An Introduction to Mersen Electrical Services Putting electrical safety to work.
High Voltage Electrical Safety
© Evaluating Electrical Risk Factors Module 3.
NECA & Salisbury Assessment Solutions Partnership.
NFPA 70E - Awareness Training1 NFPA 70E Standard for Electrical Safety in the Workplace Article 130.7(C)(1-7) – Personal Protective Equipment.
Carol Walker New Mexico Occupational Health and Safety Bureau (NM OSHA)
Hazards and Risks when working with Electricity
© Recognizing Electrical Risk Factors Module 2.
Electrical Safety The following contains disturbing images and videos. Caution is advised.
NFPA 70E Electrical Safety in the Workplace. Objectives What NFPA 70E covers Understand Arc Flash, Incident Energy, & Flash Protection Boundary Standards,
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
Y our D ata C enter P artner © 2009 Tier4 Data Center Group, Inc. All rights reserved. Electrical Safety and Your Data Center Martin Conroy, CPQ AFCOM.
Electrical Safety in the Workplace FN000385/CR. FN000385/CR, Electrical Safety in the Workplace 2 Overview NFPA 70E Objectives Electrical Hazards Mitigation.
NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces Article 130 A Operational Guide for Protection Against Shock and Arc Flash.
Oregon OSHA Grant # NFPA 70E - How to Comply with OSHA’s Electrical Standards NECA-IBEW Electrical Training Center’s Free Online Course This.
Electrical Safety in the Workplace FN000385/CR. FN000385/CR, Electrical Safety in the Workplace 2 Overview NFPA 70E Objectives Electrical Hazards Mitigation.
What is an arc flash5 min. Video arc flash5 min. What causes an arc flash10 min. Video PPE15 min. PPE demo10 min Flash hazard15 min. ***Flash hazard analysis.
Electrical Safety and Safe Work Practices
What is Arc Flash? Electrical arc flash and arc blasts release dangerous levels of heat energy, fire , molten materials, vaporized solids that can be inhaled,
CENTERLINE® 2100 Motor Control Centers with ArcShield™
NFPA 70E: Standard for Electrical Safety in the Workplace
LCLS-II CRYOPLANT CONTROLS HARDWARE FINAL DESIGN REVIEW
Personal Protective Equipment (PPE) Selection for Electrical Workers
Personal Protective Equipment
Reduced Safety/Reliability: Arc Flash Hazard Example
Murray State University
Developing a Comprehensive Electrical Program
CENTERLINE® 2100 Motor Control Centers with ArcShield™
Arc Flash Safety.
Arc Flash Fundamentals & Compliance
Presentation transcript:

ARC FLASH ANALYSIS

ARC FLASH ANALYSIS

ARC-FLASH As much as 80% of all electrical injuries are burns resulting from an arc-flash and ignition of flammable clothing. Arc temperature can reach 35,000°F - this is four times hotter than the surface of the sun Fatal burns can occur at distances over 10 ft.

ARC EXPOSURE ENERGY BASICS Exposure Energy is Expressed in cal/cm2 1 cal/cm2 Equals the Exposure on the tip of a finger by a Cigarette Lighter in One Second An Exposure Energy of Only One or Two cal/cm2 Will Cause a 2nd Degree Burn on Human Skin

Industry Standards and Regulations OSHA 29 CFR 1910 Subpart S OSHA Enforces NEC2002 110.16 & NFPA70E NFPA 70E-2000 Requirements for shock and arc flash boundaries Requirements for personal protective equipment NEC 110.16-2002

NEC 2002 110.16 Flash Protection. Switchboards, panel boards, industrial control panels, and motor control centers in other than dwelling occupancies, that are likely to require examination, adjustment, servicing, or maintenance while energized, shall be field marked to warn qualified persons of potential electric arc flash hazards. The marking shall be located so as to be clearly visible to qualified persons before examination, adjustment, servicing, or maintenance of the equipment. FPN No. 1: NFPA 70E-2000, Electrical Safety Requirements for Employee Workplaces, provides assistance in determining severity of potential exposure, planning safe work practices, and selecting personal protective equipment. FPN No. 2: ANSI Z535.4-1998, Product Safety Signs and Labels, provides guidelines for the design of safety signs and labels for application to products.

Sample NEC Warning Article 110.16 Arc Flash and Shock Hazard Appropriate PPE Required !

ARC Flash Analysis OSHA 1910.132(d) Where work will be performed within the flash protection boundary, the flash hazard analysis shall determine, and the employer shall document, the incident energy exposure to the worker (in cal/cm2) OSHA 1910.269(I)(6) Flame resistant (FR) clothing and PPE shall be used by the employee based upon the incident energy exposure associated with the specific task. As an alternative, PPE requirements of NFPA 70E Part II 3-3.9 may be used in lieu of a detailed flash hazard analysis.

Sample NEC Warning Article 110.16

Approach Boundaries Nominal System Voltage Range Limited Approach Boundary Restricted Approach Boundary Prohibited Approach Boundary Phase-to-Phase Exposed Moveable Conductor Exposed Fixed Circuit Part Includes Inadvertent Movement Adder 0 - 50 Not specified 51 - 300 10 ft. 0 in. 3 ft.6 in. Avoid contact 301 - 750 1 ft. 0 in. 0 ft. 1 in. 751V - 15 kV 5 ft.0 in. 2 ft. 2 in. 0 ft. 7 in. 15.1 – 36 kV 6 ft.0 in. 2 ft. 7 in. 0 ft. 10 in. 36.1 – 46 kV 8 ft.0 in. 2 ft. 10 in. 1 ft. 5 in. 46.1 – 72.5 kV 3 ft. 3 in. 2 ft. 1 in. 72.6 – 121 kV 10 ft. 8 in. 2 ft. 8 in. 138 – 145 kV 11 ft. 0 in. 10 ft.0 in. 3 ft. 7 in. 3 ft. 1 in.

NFPA 70E provides two choices for PPE selection: Do an arc flash hazard analysis, and document the incident energy exposure IEEE 1584 SKM (Arc Flash Evaluation Module) ArcPro Software Duke Power Cal/Flux Software As an alternate, use the “Hazard Risk Category Classifications” table to choose the PPE level required for the task

Hazard Risk Category Tables

Hazard Risk Category Classification NFPA 70E – Hazard Risk 0 This hazard risk category poses minimal risk. NFPA 70E – Hazard Risk 1 This hazard risk category poses some risk. NFPA 70E – Hazard Risk 2 This hazard risk category involves tasks that pose a moderate risk. NFPA 70E – Hazard Risk 3 This hazard risk category involves tasks that pose a high risk. NFPA 70E – Hazard Risk 4 This hazard risk category represents tasks that pose the greatest risk.

Methods of Reducing Hazard Risk Specifying Current Limiting Fuses on Low Voltage Switchgear Breakers Specifying ARC Resistance Medium Voltage Switchgear Remote Control of Switchgear Breakers High Resistance Grounding on Low Voltage and Medium Voltage (15kV and below) Systems

What We Offer Our Clients Design of safer power systems while insuring compliance with OSHA NFPA 70E standards and IEEE 1584 Save time with the fully integrated Short Circuit, Time Current Coordination, Equipment Evaluation and Arc Flash Evaluation Offer alternatives to reduce exposure to ARC Flash Energy.