Fundamentals of Product Safety Design Berri Remenick NARTE Certified Product Safety Engineer Product Safety Manager Washington Laboratories, Ltd.

Slides:



Advertisements
Similar presentations
Bonding and Grounding What? Why? How?
Advertisements

Component Symbols & Information Prof. Dr. Moustafa M. Mohamed Vice Dean, Faculty of Allied Medical Science, Pharos University in Alexandria.
Compliance With Resolution 0859 – Safety of Persons Underwriters Laboratories Inc. March 2008 Refrigerators, Freezers and Combination of Refrigerator-Freezers.
Fire Safety Requirements, Standardization and Testing Electrical & Electronic Equipment Status and Trends Presentation given at Tokyo, 9 September 2014.
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
M iniature circuit breakers to UL 489
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
An Introduction to EV Wiring By Charlton Jones Gateway EV Washington, MO.
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01.
Guide to Network Cabling Fundamentals
Designing for LED electrical safety Presentation at the Lighting Fixture Design Conference 6 th June 2013 By Ken Dale, Principal Engineer, Harvard Engineering.
Chapter : 7 : Mains Electricity
EET Survey of Electronics
© 2011 Ericson Manufacturing, Willoughby, Ohio
POWER SUPPILES LECTURE 20.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Washington Laboratories (301) Lindbergh Dr. Gaithersburg, MD European Union.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Chapter One Electrical Design and Component Basics.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Installation 2
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
CHAPTER Wiring Schematics and Circuit Testing 9 Copyright © 2016 by Pearson Education, Inc. All Rights Reserved Automotive Electrical and Engine Performance,
Electrical Safety INSTRUCTOR’S NOTES:
Smart solutions for comfort and safety UL/CSA approval of small motors.
Wiring Schematics and Circuit Testing
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
The EU Training Programme for Turkish Chamber Executives Electrical equipment Eurochambres Chamber House 19 A/D Avenue des Arts B-1000 Brussels Belgium.
MAINS ELECTRICITY. Specification Electricity Mains electricity understand and identify the hazards of electricity including frayed cables, long cables,
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Electronic Circuit Diagrams
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
Linda Bagby - SBN Program Electrical Coordinator ICARUS Electronics Meeting 27 January 2016 SBN Program Operational Readiness Clearance.
Linda Bagby - SBN Program Electrical Coordinator T600 Installation 8 February 2016 SBN Program Operational Readiness Clearance.
Exit REMOTE POWER SYSTEM ”Turning your copper into gold”
Flammable Liquids Directorate of Training and Education
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
the Most Beneficent, the Most Merciful
Exit REMOTE POWER SYSTEM ”Turning your copper into gold”
Power Supply. 2 Power Supply w/Line Conditioner The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for.
Automotive Heating And Air Conditioning
PROTECTION AGAINST INDIRECT CONTACT
SUB-STATIONS.
Special-Purpose Outlets— Electric Heating, Air Conditioning
LCLS-II CRYOPLANT CONTROLS HARDWARE FINAL DESIGN REVIEW
2011 Changes Two Minute Drill
Current Electricity and Electric Circuits
EET 422 EMC & COMPLIANCE ENGINEERING
Installation of Non-Required Equipment
The Key to Understanding Wiring Diagrams
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
The Electric Circuit.
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
ECMA-287 Safety of Electronic Equipment Safeguards to reduce harmful exposure to energy sources Ecma TC12 Rue du Rhône CH-1204 Geneva - T: +41.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Current Electricity and Electric Circuits
The Key to Understanding Wiring Diagrams
MAINS ELECTRICITY.
Author Team Supervisor A. Toral M. Mansouri S.L. Birch Y.K. Sin
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Fundamentals of Product Safety Design Berri Remenick NARTE Certified Product Safety Engineer Product Safety Manager Washington Laboratories, Ltd. September 14, 2007 Gaithersburg, MD

Outline Background Insulation Component Selection Labeling Documentation Wiring Resistance to Fire

Product Safety Requirements US/Canada: NRTL Listing (cULus, cTUVus, cCSAus) Legal requirement, customer requirement, or to limit liability Europe: CE Mark Legal requirement Others: CB Report To facilitate International Approvals.

Product Safety Hazards Electric Shock Hazards: Accessible parts over 30Vrms, 42.4Pk, or 60VDC. Energy Hazards: Energy level over 240VA or 8A Fire Hazards: Materials, Enclosure, Abnormal conditions Mechanical Hazards: Moving parts, Sharp edges, Tipping, Handles Radiation Hazards: Lasers, UV, Sonic Thermal Hazards: External temps, component temps

Product Safety Design Guidelines

Design Requirements Protection against electric shock and energy hazards: The OPERATOR can not touch bare or inadequately insulated parts at hazardous voltage or energy levels. Hazardous Voltage Level is typically >30Vrms, 42.4Vpeak, or 60VDC. Hazardous energy is typically >240VA or 8A Protection may be provided via insulation, guarding or interlocking.

What is Insulation? Physical barrier between two parts (tape, plastic shield, wire insulation, enclosure, etc) Separation between two parts through air or along a surface (creepage or clearance distance)

Insulation Types Functional / Operational Insulation (DC input to ground) Basic Insulation (Primary to Ground, TNV to Ground, TNV to SELV) Reinforced Insulation (Primary to Secondary)

Reinforced Insulation Example

Spacings (Creepage / Clearance) Based on the required insulation for your circuit. Based on the maximum working voltage for your circuit. Based on the environment the product will be used in (Pollution Degree) Based on the PCB material: Material Group - Comparitive Tracking Index (CTI)

Creepage / Clearance

Creepage / Clearance Creepage Clearance Creepage = distance between two points along the surface Creepage is measured on 1:1 artwork or on a blank board Locations of circuits determined by reviewing schematics Clearance Clearance = distance between two points through the air Clearance is measured on a populated sample

Component Selection Safety Critical Components must have the appropriate approvals or additional evaluation will be required. Safety Critical Components: Devices in the AC path (inlets, fuses, switches, power supplies, transformers, etc.) Motors, fans Power conversion components (AC-DC or DC-DC Converters) Any isolation component (Transformer, Bridging Capacitors, MOVs,) Wiring Batteries Others depending on their application.

Component Selection For NRTL approvals, all components must be UL approved. For CE Mark approvals, all components must have a European approval such as CE, TUV, VDE, etc. (exception: fuses and wiring can be UL approved) For GS or CB Scheme approvals, all components must have a TUV, VDE, or other official European approval. CE Mark is not acceptable for these approvals. Approval certificates required (TUV or VDE Cert, CE Declaration of Conformity, UL File number, etc.)

Labeling and Marking Rated voltage, current or power, frequency Manufacturer’s name or registered trademark. Model or type number. Fuse replacement info (if applicable). IEC symbols wherever possible. Warnings and Cautions appropriate for the particular equipment.

User Instructions Installation Instructions - information regarding mounting, connection to the supply, ventilation, input ratings, etc. All information regarding use, cleaning, maintenance (if necessary). All safety warnings and cautions. Rack Mount instructions. Safety-related information to be in appropriate language of the country you are exporting to. Some standards have entire sections of specific info that must be in manual.

Wiring and connection to the supply – Protective Earth - PE conductor must be green/yellow or bare insulation conductor PE connections must be double secured so that both the wire and insulation are crimped IEC PE symbol shall be marked adjacent to PE stud PE conductor shall connect to chassis directly from input (inlet, terminal block, etc). PE conductor must be secured with washer and locknut. Additional PE conductors can be secured to PE stud with a second washer and locknut.

PE Stud Example EMI FILTER CHASSIS TO OTHER CONNECTION GROUNDS MECHANICALLY SECURED GROUND: GREEN/YELLOW WIRE SAME GAUGE AS OR BIGGER THAN SUPPLY

Wiring and connection to the supply – Primary Wiring - All AC wires shall be double secured. Double securement can be met by: Double crimp connector or Single crimp connector and cable tie or Single crimp connector and shrink sleeving. AC wiring shall be rated for the maximum working voltage and current. AC wiring shall be isolated from low voltage wiring or low voltage parts, this can be accomplished by: Shrink sleeving the AC conductors or By routing the AC conductors away from low voltage wires and securing with cable ties or By using UL1015 Reinforced Insulation wire.

Resistance to fire and control of fire spreading Enclosures, components, and other parts shall be constructed such that propagation of fire is limited. Flammability of enclosure, internal, and external parts shall be adequate for the use of that part. Flammability ratings 5VA – Most fire resistant 5VB V0 V1 V2 HB40 HB75 - Least fire resistant Foamed materials: HF-1 HF-2 HBF

Resistance to fire and control of spread of fire 60950-1 Fire enclosure openings shall be: Top and side openings shall be: less than 5mm in any dimension or less than 1mm in width regardless of length or meet the 5 projection rule. There shall be no bottom openings (some exceptions allowed but difficult to meet)

Methods for Meeting Fire Requirements in 61010-1 Requirement: There shall be no spread of fire outside the equipment in Normal or Single Fault Conditions. Methods of Compliance: A: Testing in single fault conditions B: Reducing sources of ignition within the equipment C: Containing fire within the equipment should it occur

Requirements for fire enclosure - Components in primary circuit - Components in secondary circuits that are not supplied by LPS - Components in secondary circuits supplied by LPS but not on V-1 material - Components with unenclosed arcing parts - Insulated wiring

Parts not requiring Fire Enclosure - Motors - Transformers - Wiring and cabling insulated with PVC, TFE, PTFE, FEP, neoprene or polymide - Connectors in secondary circuits powered by less than 15VA or LPS - Components in secondary circuits supplied by LPS and on V-1 material - Components in secondary circuits supply by max 15VA and on HB785 if <3mm or HB40 if >3mm.

Plastic materials used for fire enclosure Movable equipment <18kg: V-1 or pass A.2 HWI test (if <13mm from high temp parts) Movable equipment >18kg or stationary equipment: 5VB or pass A.1 Materials filling an opening in a fire enclosure:

Plastic materials used inside a fire enclosure V-2 or HF-2 or pass A.2 Exceptions: Electronic components (IC’s, optos, etc.) mounted on V-1. Wiring and connectors insulated with PVC, TFE, PTFE, FEP, neoprene, or polymide. Clamps, cable ties. Wire marked VW-1 or FT-1 or better. Others….

Plastic materials used outside a fire enclosure Material outside fire enclosure: HB75 if <3mm or HB40 if >3mm or HBF or Glow Wire test at 550C Connectors: V-2 or pass A.2 or mounted on V-1 and be small or be in secondary circuit with max 15VA Exceptions: Electronic components (IC’s, optos, etc.) mounted on V-1. Wiring and connectors insulated with PVC, TFE, PTFE, FEP, neoprene, or polymide. Clamps, cable ties. Others….

Washington Laboratories, Ltd. Help you select the proper Directives and Standards to apply to your product. Evaluate and test your product to the appropriate Safety Standard and offer solutions for non-compliances. Provide product design assistance. Obtain cTUVus, cCSAus, cULus, GS Mark, and other approvals. WLL is a Partner Test Lab for TUV Rheinland for 60950-1, 61010-1, and 60065

Washington Laboratories, Ltd. Give us a call or send us info about your product - we’re here to help! Berri Remenick Product Safety Manager Phone: 301-473-1255 Fax: 301-473-1257 E-mail: berrir@wll.com