Microspectrophotometry General Section. General Comments Why do we use MSP when there are other techniques available for colour comparison? Why do we.

Slides:



Advertisements
Similar presentations
Uv spectroscopy.
Advertisements

Richard Young Optronic Laboratories Kathleen Muray INPHORA
AN EVALUATION STUDY FOR FIBRE ANALYSIS BY UV-VIS MICROSPECTROPHOTOMETRY By Johanne Almer, Eleanor McAnsh, & Barbara Doupe Centre of Forensic Sciences Ministry.
UV-Vis SPECRTOSCOPY.
HIGHER PHOTOGRAPHY UNIT 1: BASIC CAMERA TECHNIQUES The word Photography comes from the Greek word photos which means light and graphe which means to draw.
A QUICK OVERVIEW OF LAB REPORT 0 GRADER COMMENTS Physics 119 Lab 0 Rubric Commentary.
Classroom Change This Friday’s class will be at Physics 1201.
Dyed Sand Lab Book Donna S. Lutz Iowa State University 2000.
Experiment on Plastics by Burning test Done by: Jap Xin Yi Assignment 6.
COLOUR YEAR 11 - UNIT ONE PHYSICS
Fiber and Fabric Evidence
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
Avoiding bleed-through artifacts on the confocal microscope Fluorescent dyes are molecules that, when exposed to light of a specific range of wavelengths,
Microspectrophotometry Validation. Reasons for Changing Instruments Reduced reliability. Limited efficiency. Limited availability and cost of replacement.
GRE ’ s Justification HE Yuntang China Automotive Technology and Research Centre UNOG , Geneva , 31 March 2011 GRE ’ s Justification HE Yuntang.
Ultraviolet and Visible Spectroscopy Chemical Ideas 6.8.
Fibers and Textiles Mr. Chapman – Forensics 30.
Operations Management
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
Advanced Higher Chemistry Unit 1 Spectroscopy. Spectroscopy  Spectroscopy is used to give information regarding the structure of atoms or molecules.
Richard Young Richard Young Optronic Laboratories Kathleen Muray Kathleen Muray INPHORA Carolyn Jones Carolyn Jones CJ Enterprises.
1 Perception. 2 “The consciousness or awareness of objects or other data through the medium of the senses.”
Probability and Statistics in Engineering Philip Bedient, Ph.D.
Chemometrics Method comparison
Scanning and Image Processing -by Steve Clough. GSI Lumonics cDNA microarrays use two dyes with well separated emission spectra such as Cy3 and Cy5 to.
To Atomic and Nuclear Physics to Atomic and Nuclear Physics Phil Lightfoot, E47, (24533) All these slide presentations are at:
ABC of Quality Control A problem based approach RT ERASMUS NHLS / FACULTY OF HEALTH SCIENCES, UNIVERSITY OF STELLENBOSCH 20th July, 2007, Bela Bela.
VALIDATION METHODOLOGY
Trace Evidence (Part I)
Standardization and Test Development Nisrin Alqatarneh MSc. Occupational therapy.
Chapter 3: Colorimetry How to measure or specify color? Color dictionary?
Qualitative Data Analysis. 2 In This Section, We Will Discuss:  How to load data files.  How to use Signal Options for data display.  How to apply.
Hair Evidence Human or non- human? Body part origin (scalp, pubic, limb) Forcibly removed? DNA on root tissue Microscopic Examination.
Emission Spectroscopy Electrons jump from higher levels to lower ones.
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
LMS Stability, Data Correction and the Radiation Accident within the PrimEx Experiment by LaRay J. Benton M.S. Nuclear Physics May 2006 Graduate North.
Lecture 12 ASTR 111 – Section 002.
UV-Vis Absorption Spectroscopy
Infrared Spectroscopy
Forensic Application of Fluorescence
Microspectrophotometry Calibration. Calibration Calibration ensures that the instrument is functioning to an acceptable level. Before carrying out calibration.
An Introduction to Analyzing Colors in a Digital Photograph Rob Snyder.
Spatial Distribution of Boron and PL Optical Centers in Type IIb Diamond This study gives a detailed analysis of the spatial distribution of optical centers.
Microspectrophotometry First Derivative Spectra..
A confocal Raman microprobe analysis of partial discharge activity in gaseous voids N A Freebody 1*, A SVaughan 1, G C Montanari 2 and L Wang 2 1 University.
SPECTROPHOTOMETRY IN BIOTECHNOLOGY. LIGHT IS A TYPE OF ELECTROMAGNETIC RADIATION Imagine electromagnetic radiation like waves on a pond – But instead.
Relating [solute] to Absorbance of Light Use of the Spectronic 20—a Visible Spectrophotometer.
Forensic Science Hair Analysis. Hair is chemically stable especially when compared to other physiological materials such as blood, semen, or any other.
Light - Radiated when electrons in molecules move from a higher energy level to a lower one. A photon is produced to maintain conservation of energy and.
Unit-3 Control chart Presented by N.vigneshwari. Today’s topic  Control chart.
Comparison Between AM and FM Reception. 21/06/20162 FM Receiver.
Date of download: 6/25/2016 Copyright © 2016 SPIE. All rights reserved. Overview (a), images of the λ-stack (b) and spectra of ROI 1 and 2 (c) of a 24.
Date of download: 6/26/2016 Copyright © 2016 SPIE. All rights reserved. The absorption spectra of oxy- and deoxyhemoglobin relative to emission spectra.
Hair and Fiber Evidence Unit 2A
Applications of UV-Vis Spectroscopy
CH. 6 Photographic Transparencies
Cross-Cal paper Kristin Kruse Madsen.
Fibers and Probability
Fibers and Probability
DECEMBER 4, 2012 EQ: How can synthetic fibers be used to solve crimes?
Variations on Aschs Research
Forensic Examination of Fibers
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
Visible Light.
Colourimetry The absorption of light by a coloured solution is directly related to the concentration of the solution. Colourimetry determines the concentration.
Documentation Analysis
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Matthew Rose - Emission Spectra of Bicron Scintillators
Matthew Rose - Emission Spectra of Bicron Scintillators
Presentation transcript:

Microspectrophotometry General Section

General Comments Why do we use MSP when there are other techniques available for colour comparison? Why do we use MSP when there are other techniques available for colour comparison? Comparison Microscopy is important but is only a subjective technique when comparing one fibre with another. The lighting conditions on both microscopes must be identical and the operator must be capable of using the microscopes. Comparison Microscopy is important but is only a subjective technique when comparing one fibre with another. The lighting conditions on both microscopes must be identical and the operator must be capable of using the microscopes.

HPLC, TLC, CE are techniques that can be used for colour comparison but some are problematical and all are destructive. The advantage over comparison microscopy is that they are objective techniques. HPLC, TLC, CE are techniques that can be used for colour comparison but some are problematical and all are destructive. The advantage over comparison microscopy is that they are objective techniques.

MSP is also an objective technique and is non destructive. MSP is also an objective technique and is non destructive. It is a technique that not only allows fibres to be classed as identical but also enables them to be differentiated. It is a technique that not only allows fibres to be classed as identical but also enables them to be differentiated. Metamerism is the condition where two colours appear similar under one set of lighting conditions but different under another. Metamerism is the condition where two colours appear similar under one set of lighting conditions but different under another.

It can be difficult for the human eye to detect metameric pairs but instrumentation such as an MSP can do this. It can be difficult for the human eye to detect metameric pairs but instrumentation such as an MSP can do this. Natural fibres such as wool and cotton generally show a large amount of dye variation from one fibre to another. It can take time to find a fibre in a control item that matches a recovered fibre exactly. Natural fibres such as wool and cotton generally show a large amount of dye variation from one fibre to another. It can take time to find a fibre in a control item that matches a recovered fibre exactly.

When obtaining spectra from fibres it is important to take the measurement in a ‘clean area’. When obtaining spectra from fibres it is important to take the measurement in a ‘clean area’. Examples follow. Examples follow.

The uptake of dye may also vary in man made fibres but does not occur as often as in natural fibres. The uptake of dye may also vary in man made fibres but does not occur as often as in natural fibres. However it is important to cover the complete range of dye variation when obtaining spectra from a control item. However it is important to cover the complete range of dye variation when obtaining spectra from a control item. In a general situation it is advisable to measure 5 or 6 man made fibres and about 10 natural fibres. In a general situation it is advisable to measure 5 or 6 man made fibres and about 10 natural fibres.

The number of recovered fibres measured will vary from one laboratory to another but most will test at least 33% up to a maximum of 10 recovered from one item. The number of recovered fibres measured will vary from one laboratory to another but most will test at least 33% up to a maximum of 10 recovered from one item. The normal way of comparing spectra is either on screen or by producing hard copies and overlaying them. The normal way of comparing spectra is either on screen or by producing hard copies and overlaying them.

The comparison involves peak positions, peak shapes, absorbance values and peak ratios. The comparison involves peak positions, peak shapes, absorbance values and peak ratios. In my opinion there are 4 end results: In my opinion there are 4 end results: +ve (positive) +ve (positive) -ve (negative) -ve (negative) +WR (positive within the range of the control spectra) +WR (positive within the range of the control spectra) Inc (inconclusive) Inc (inconclusive)

A positive result is where there is an exact spectral match. A positive result is where there is an exact spectral match. A negative result is where the spectra are totally different or the recovered fibre falls outside the spectral range of the control. If the latter happens it may be advisable to run additional control fibres. A negative result is where the spectra are totally different or the recovered fibre falls outside the spectral range of the control. If the latter happens it may be advisable to run additional control fibres.

A fibre which is said to be positive within the range of the control fibres means there is no exact match with one spectrum but all the parts of the recovered fibre spectrum matches parts of the control spectra. The fibre therefore falls within range of the control. A fibre which is said to be positive within the range of the control fibres means there is no exact match with one spectrum but all the parts of the recovered fibre spectrum matches parts of the control spectra. The fibre therefore falls within range of the control.

Inconclusive is only applied if the spectrum has very little detail. Inconclusive is only applied if the spectrum has very little detail.

Instumentation Problems In order to obtain good spectra it is important to be aware of instrument problems that may occur. In order to obtain good spectra it is important to be aware of instrument problems that may occur. The instrument should be set up for Kohler illumination before use and calibration standards should be used. The instrument should be set up for Kohler illumination before use and calibration standards should be used. Calibration will be covered in more detail later. Calibration will be covered in more detail later.

If strange spectra are obtained after the correct set up and calibration procedures have been used then operators need to know what the problem is. If strange spectra are obtained after the correct set up and calibration procedures have been used then operators need to know what the problem is. Some examples will follow. Some examples will follow.

Degrading UV objective

New objective but lamp not aligned

New objective and lamp properly aligned

Degrading UV objective

New objective but lamp not aligned

New objective and lamp properly aligned

Normal absorbance spectrum of a fibre

Normal absorbance spectrum of the lamp

Overloaded absorbance spectrum of a fibre

Overloaded absorbance spectrum of the lamp

Normal fibre spectra

Spectral waves caused by light source being in contact with the slide

Value of UV Spectra UV MSP will not provide additional information for all fibres but will in many cases. UV MSP will not provide additional information for all fibres but will in many cases. In 1994 Grieve mentioned that grey and black cotton fibres often gave additional information in the UV region. In 1994 Grieve mentioned that grey and black cotton fibres often gave additional information in the UV region. He also said that turquoise green cotton fibres can be difficult to discriminate in the visible region of the spectrum. He also said that turquoise green cotton fibres can be difficult to discriminate in the visible region of the spectrum.

He compared 27 fibres of this colour and type – 351 comparisons. He compared 27 fibres of this colour and type – 351 comparisons. When comparing them over the range nm 10 pairs had indistinguishable spectra. However when compared over the range nm the number of matching pairs was reduced to 6. When comparing them over the range nm 10 pairs had indistinguishable spectra. However when compared over the range nm the number of matching pairs was reduced to 6.

In 2005 myself and two colleagues did a complete validation and evaluation of the J&M MSP800 instrument but this was only published as an internal document. In 2005 myself and two colleagues did a complete validation and evaluation of the J&M MSP800 instrument but this was only published as an internal document. Part of the project was to examine both coloured and undyed fibres from a range of fibre types. Part of the project was to examine both coloured and undyed fibres from a range of fibre types. As wool and polyester absorb all light below the 300nm region approximately the only region in which additional information is available is between nm. As wool and polyester absorb all light below the 300nm region approximately the only region in which additional information is available is between nm.

Acrylic, cotton, nylon, polypropylene and viscose fibres were examined and showed that more than 70% of the samples within each fibre type offered information in the UV region. The average figure for all the coloured fibre types above was 87%. Acrylic, cotton, nylon, polypropylene and viscose fibres were examined and showed that more than 70% of the samples within each fibre type offered information in the UV region. The average figure for all the coloured fibre types above was 87%. The wool samples gave 21% additional information and the polyesters 29%. The wool samples gave 21% additional information and the polyesters 29%.

An additional part of the project was to examine samples from manufacturers that started as undyed fibre through to the finished product. An additional part of the project was to examine samples from manufacturers that started as undyed fibre through to the finished product. The fibre types investigated were viscose, polyester and wool. The fibre types investigated were viscose, polyester and wool. It was only after dyeing that any of the samples gave information in the UV region. It was only after dyeing that any of the samples gave information in the UV region.

Additional Information about the UV region In my experience information above 250nm is worth collecting. In my experience information above 250nm is worth collecting. Fibres exposed to UV light for any period of time begin to bleach. Fibres exposed to UV light for any period of time begin to bleach. The bleaching of the fibre can cause the absorbance spectrum to change with respect to the absorbance levels and peak ratios and as a result the overall shape. The bleaching of the fibre can cause the absorbance spectrum to change with respect to the absorbance levels and peak ratios and as a result the overall shape.

Changing the lighting conditions i.e. turning the lights on and off in the laboratory can make very minor changes to the UV region of the spectrum. Changing the lighting conditions i.e. turning the lights on and off in the laboratory can make very minor changes to the UV region of the spectrum. Therefore when comparing fibres in casework the lights should always be on or off. Therefore when comparing fibres in casework the lights should always be on or off.