Village of Frankfort, Illinois April 21, 2010 The 2009 International Energy Conservation Code Overview.

Slides:



Advertisements
Similar presentations
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
Advertisements

U.S. Department of Energy Building Energy Codes Program
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
eQuest Quick Energy Simulation Tool
ENERGY STAR Multifamily High Rise Program
Guidelines and Required Codes That Affect Building Design
Heating, Ventilating, and Air-Conditioning
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
2009 Washington State Energy Code Residential Sections
Residential Provisions of the 2012 International Energy Conservation Code July 2011 PNNL-SA
Manitoba Energy Code for Buildings 2013
2009 versus 2012 IECC Maryland Affordable Housing Coalition June 26th, 2012.
Effective March 15, New Base Code 2009 International Energy Conservation Code (IECC) Florida specifics are integrated into the document The biggest.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
West Virginia's residential building code is mandatory statewide; however, adoption by jurisdictions is voluntary. The 2013 West Virginia Legislature.
The House as a System 1. Air Temperature and Water Vapor.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
This 12 part PowerPoint series is taken directly from Energy Savers Booklet, Tips on Saving Energy & Money at Home, U.S. Department of Energy.
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
Chapter 2: Energy Ratings and Economics To be used with the Guide to Building Energy Efficient Homes in Kentucky.
ENERGY STAR Multifamily High Rise Program Testing and Verification Protocols Webinar – Part II August 2011.
Chapter 4: Air Leakage Control: Materials and Techniques
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/training 1 Building Energy Codes An Introduction Department of Energy Energy Efficiency & Renewable.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Copyright 2008, International Code Council 2012 IECC ® for SERBCA Based on the 2012 International Energy Conservation Code.
Massachusetts “Stretch” Energy Code Marc Breslow Executive Office of Energy & Environmental Affairs.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
The Fall Builders’ Forum Part 9 Energy Efficiency and Ventilation Regulations “Effective December 19 th, 2014”
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Arkansas Energy Code 2004 Compliance
1 Connecticut’s New Energy Code Connecticut ASHRAE Tech Session October 13, 2011 Frederick F. Wajcs, Jr. Senior Energy Engineer Connecticut Light and Power.
IECC, REScheck, and COMcheck Mark Halverson Pacific Northwest National Laboratory PNNL-SA
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
Massachusetts New Homes with ENERGY STAR ® The sponsors of the Massachusetts New Homes with ENERGY STAR are Bay State Gas, Berkshire Gas, Cape Light Compact,
Residential Provisions
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Residential Energy Code Compliance
North Carolina State Buildings Efficiency Conference
Building Codes and Interior Design
IRC CHAPTER 11 AND HERS RESIDENTIAL ENERGY
Insulation and Infiltration
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
Introduction to Building Codes. Babylonian Code of Hammurabi Purpose of Building Codes Engineering Failures US History of Building Codes Building Officials.
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/training 1 BUILDING ENERGY CODES UNIVERSITY Residential Requirements of the 2009 International Energy.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
What’s new?. …including “fixes” made to the code in the 2012 Supplement August,
1 VBBL and improved envelopes 1&2 Family Homes in Vancouver 2014 VBBL New + Existing Homes Chris Higgins City of Vancouver.
Helping Massachusetts Municipalities Create a Greener Energy Future Code Informational Session February 10, 2016.
Sprinkler Loads on Trusses
Zone 4 R-38 Ceilings U-0.35 Windows, Doors R-13 Walls R-19 Floors R-10 Foundations.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Stretch Code Informational Session March 16, 2011.
Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 1 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Stretch Code Informational Session February 16, 2011.
2015 International Energy Conservation Code
Energy Codes and the Building Envelope
Truss Heel Heights and Energy Code Requirements
2015 Energy Code: Major Changes for Residential Buildings
Energy Code Program Manager – SPEER
BUILDING Codes And Standards
Compliance Software Tool Approval Technical Assistance Manual
Introduction to Building Codes
Introduction to Building Codes
Introduction to Building Codes
Presentation transcript:

Village of Frankfort, Illinois April 21, 2010 The 2009 International Energy Conservation Code Overview

Presented By: Don Plass, C.B.O., M.C.P., LEED AP Director of Code Enforcement Village of Hoffman Estates

Introduction and Overview Codes History of Illinois Energy Efficiency Building Act Residential Applications of the 2009 IECC RESCheck/REM Rate

Codes Building Code – A set of rules of procedures designed to secure uniformity and protect the public interest in such matters as building constriction and public health, established by a public agency and commonly having the force of law in a particular jurisdiction

Earliest Recorded Building Code The Code of Hammurabi 1780 BC The earliest recorded “Building Code” comes from an 8 foot stone slab recovered in the Persian Mountains in It is preserved today in the Louvre, Paris The Code was written by the ruler of Babylon: King Hammurabi The Code contained 282 laws, of which 5 referred to construction

Hammurabi Code Numbers If a builder build a house for someone and does not construct it properly, and the house for which he built fall in and kills the owner, the builder shall be put to death. 230-If it kill the son of the owner, the son of the builder shall be put to death.

233-If a builder builds a house for someone, even though he has not completed it, if then the walls seem toppling, the builder must make the walls solid from his own means

Present day codes: Building Officials and Code Administrators (BOCA) was published in 1915 (Midwest) Uniform Building Code (UBC) was published in 1927 (West of Mississippi) Southern Building Code Congress (SBCC) was published in 1940 (South East) “Standard Building Code" These are commercial codes

CABO In 1972, the Council of American Building Officials (CABO) was incorporated with the combination of the three model commercial code groups: BOCA, UBC and SBCC. CABO is a prescriptive code for residential one and two family dwelling units.

Model Energy Code-Evolution In 1973 the first Model Energy Code (MEC) was published by CABO In 1998 the International Energy Conservation Code was published by the three model code groups who were merging into the International Code Council (ICC) In 2000 the first International Energy Conservation Code (IECC) was published by ICC

2000 International Energy Conservation Code (IECC) The first published International Code Council (ICC) Energy Code 19 Climate Zones (CZ) 198 pages in length

2006 IECC Reduced number of Climate Zones to 8 Zones Reduced to 63 pages

2009 IECC Applies to Residential Buildings One and Two Family dwellings, Townhouses Multifamily dwellings three-stories or less in height Commercial Buildings Multifamily dwellings four stories or greater in height Eight global climate zones Compliance assessment choices Prescriptive criteria-for ease of enforcement Simulated Performance criteria-for design flexibility

2009 IECC Changes in Residential Requirements Stringency-some key differences New requirements Building envelope tightness Duct testing Lighting equipment Pool controls and covers Snow melt controls Moisture control requirements moved to IRC No mechanical trade-offs allowed

Envelope Stringency Changes-2009 IECC Fenestration U—Factor, Climate Zone 4 is lowered from 0.4 to 0.35 Wood frame wall U-Factor, CZ5-CZ6 lowered from to `Minimum R-Value for “batt – only” raised from 19 to 20 Basement wall U-Factor, CZ6-CZ7 lowered from to Minimum R-Value raised from 10/13 to 15/19

Building Envelope Tightness – 2009 IECC Mandatory air leakage section for building thermal envelope ( ) has been revised to include attic openings and rim joist junctions New air sealing and insulation section ( ) added with testing and visual inspections options

Duct Testing – 2009 IECC New Duct Testing requirements are in Section for either a post construction or rough-in test, unless ducts and air handler are located within the conditioned space

Lighting Equipment – 2009 IECC A new requirement in Section 404 that 50 % of lamps in permanently installed lighting fixtures shall be high-efficacy lamps

Pool Controls and Covers – 2009 IECC A new Section in pools requires a readily accessible on/off switch, time switches for heaters and pumps along with pool covers

Snow Melt Controls – 2009 IECC A new Section has been added for snow melt controls

Moisture Control Requirements to IRC Moisture control requirements (Vapor Barriers) have been moved to the 2009 International Residential Code

No Mechanical Tradeoffs Allowed Table (1) sets the standard for heating and cooling systems to be “as proposed” This removes justification for the justification for the mechanical systems trade off used in REScheck

IRC not equal to IECC Energy Chapter in IRC is not equal to the IECC DOE does not recognize the IRC for energy IRS does not recognize the IRC for tax credits FHA does not recognize the IRC Illinois does not recognize the IRC

History of the Illinois Energy Conservation Code (Commercial) Public Act was signed into law in August of 2004 as the Illinois Energy Conservation Code for Commercial Buildings Became effective April 8, 2006 (2000 IECC/2001 IECC Supplement) Revised to exclude supplements on October 9, 2007 On August 18, 2009 the 2009 IECC was adopted for all Commercial projects

Illinois Energy Conservation Code (Residential) Public Act was signed on August 28, 2009 to include Residential structures The Energy Efficient Commercial Building Act became “The Energy Efficient Building Act” Rules for enforcement were filed with the SOS on January 29, 2010 under Emergency Rules and is effective for enforcement when filed. The Rules are in the first of two Public Comment Periods

What the Law Requires Follow the Latest published edition of the International Energy Conservation Code (IECC) Commercial/Residential permit applications must follow the Code any time a Permit is applied for

Amending the Illinois Energy Code Commercial: No unit of local government may be less stringent than the 2009 IECC Nothing prevents a unit of local government from adopting an energy efficiency code or standards that are more stringent than this code

Amending the Illinois Energy Code Residential: No unit of local government including any Home Rule Unit, may regulate the IECC in a manner that is either less or more strict than the 2009 IECC

2009 IECC/Residential More Strict The following entities may regulate energy efficient building standards more stringent than the 2009 IECC (i) If on or before May 15, 2009 has adopted by reference the 2006 IECC (equal/more stringent) (ii) If on or before May 15, 2009 has provided the CDB with a code/standard equal to or more stringent than the 2006 IECC (iii) Population of 1,000,000 or more (Chicago)

Residential Applications of the 2009 IECC (Chapter 4) Structure of the 2009 IECC Chapter 1Administrative Chapter 2Definitions Chapter 3Climate Zones Chapter 4Residential Energy Efficiency Chapter 5Commercial Energy Efficiency Chapter 6Referenced Standards

Overview of 2009 IECC Residential The focus is on the building envelope Ductwork – seal and insulate There are limited space heating, AC and water heating requirements No appliance requirements Lighting fixtures shall have 50% of permanently installed fixtures with high-efficacy lamps

Chapter 1 - Administration All low rise (3 stories or less) houses, condominiums, townhomes and apartments (R-2, R-3, R-4) If the building is not classified as residential, it is classified as commercial Includes new construction, alterations, repairs and additions i.e. Window replacements are considered under this

Exceptions to Thermal Provisions Very low energy use( less than 3.4 BTU/h-sq ft) Buildings neither heated or cooled Existing buildings Historic buildings

Additions, Alterations, Renovations, Repairs Must conform to new work standards Existing do not need to comply (if not changed) Addition can comply alone or with existing structure Exceptions: Installing storm windows over existing fenestration Glass only replacements Exposed, existing ceiling, wall or floor cavities if already filled with insulation Where existing roof, wall or floor cavity is not exposed Re-roofing when neither sheathing nor insulation is exposed Insulate above or below ceiling Attics without insulation in the cavities

Construction Documents Required Information on plans Insulation materials and R-Values Fenestration and U-Factors Mechanical system design criteria Mechanical and service water heating systems and equipment types, along with sizes and efficiencies Duct sealing Duct and pipe insulation and locations Lighting fixture schedule/showing high-efficacy lamps

Chapter 2 - Definitions Air Barrier: Material(s) assembled and joined together to provide a barrier to air leakage through the building envelope. An air barrier may be a single material or a combination of materials. High Efficacy Lamps: Compact fluorescent lamps, T-8 or smaller diameter linear fluorescent lamps R-Value: Thermal Resistance R=1/U U-Factor: Thermal Transmittance U=R/1 Code: The 2009 International Energy Conservation Code Residential Building: Three stories or less above grade

Building Thermal Envelope-The basement walls, exterior walls, floor, roof, and any other building element that enclose conditioned space. This boundary also includes the boundary between conditioned space and any exempt or unconditioned spaces.

Conditioned space – An area or room within a building being heated or cooled, containing uninsulated ducts, or with a fixed opening directly into an adjacent conditioned space.

Chapter 3 – Climate Zones Listed by state and county Interior Design Conditions: Max 72 Degrees for Heating and a minimum of 75 degrees for cooling Requirement of materials to be marked for inspection Default Fenestration Factors

Chapter 4 – Residential Energy Efficiency Code Compliance Tools Prescriptive None Needed Total Building “UA” Trade Off REScheck Software Energy Analysis Software For Example: REM/Design REM/Rate

Three Code Compliance Options Prescriptive R-Values U-Factor and “UA” Alternatives U-Factor Total Building UA Simulated Performance (Software) Simulated Performance Alternative 405

Insulation and Fenestration Requirements by Climate Zone

U-Factor Requirements by Climate Zone

U-Factor and Total UA (REScheck) U-Factor Alternative Similar to Prescriptive but uses U-Factors instead of R- Values Allows for innovative or less common construction Total UA Alternative Same as U-Factor Alternative but allows trade-offs across all envelope components

Attic Access Hatches Weatherstrip and insulate doors/panels from conditioned spaces to unconditioned spaces (i.e. attics and crawl spaces) Insulate to a level equivalent to surrounding surfaces Provide access to all equipment that will prevent damaging or compressing the surrounding equipment Install a wood framed or equivalent baffle or retainer when loose fill insulation is installed

Air Leakage (Mandatory for all) Air Leakage Recessed Lighting Fixtures Maximum Fenestration U-Factor and SHGC Fireplaces

Building Thermal Envelope The following shall be caulked, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable fim or solid material All joints, seams and penetrations Site built windows, doors and skylights Openings between window and door assemblies and their respective jambs and framing Utility penetrations Dropped ceilings or chases adjacent to the thermal envelope

Knee walls Walls and ceilings separating a garage from conditioned spaces Behind tub and showers on exterior walls Common walls between dwelling units Attic access openings Rim joist junctions All other sources of infiltration

Areas for Air Leakage Windows/doors Between sole plate Floors and exterior wall panels Plumbing Electrical Service access Recessed lighting Rim Joist junction

Air Sealing and Insulation-2 Options Two Options to Demonstrate Compliance Blower Door-When tested air leakage is <7 ACH when tested with a blower door at 50 Pascals Testing after rough-in and installation of building envelope penetrations When items listed in Table applicable to the method of construction are field verified (Section )

Recessed Lighting Recessed lighting in the building thermal envelope shall be sealed to limit air leakage between conditioned space and unconditioned space All recessed luminaries shall be sealed with a gasket or caulk between the housing and the interior wall

Mechanical Equipment Equipment efficiency is set by Federal Law-Not the I-Codes

Mechanical System Controls (Mandatory) Programmable thermostat-controls Ducts Sealing (Mandatory) Insulation (Prescriptive) HVAC Piping Insulation Circulating Hot water systems Ventilation Equipment sizing Snow melt controls Pools

Programmable Thermostat If forced air: At least one programmable thremostat per dwelling unit Programmed with: Heating temperature set point no higher than 70 degrees Cooling temperature set point no lower than 78 degrees

Ducts Insulation (Prescriptive) Ducts outside the building envelope shall be R-8; all other ducts: R-6 Sealing (Mandatory) Joints and seams shall comply with IRC Section M Building framing cavities shall not be used as supply ducts

Piping Insulation R-3 required on HVAC systems Exception: Piping that conveys fluids between 55 and 105 degrees R-2 required on all circulating domestic hot water systems The system also requires a readily accessible manual switch An inspection of all pipe insualtion is required prior to cover up

Ventilation and Equipment Sizing Ventilation Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not working Equipment Sizing IECC references Section M of the IRC Load calculations determine proper size of equipment Calcualtions in accordance with Manual J

Snow Melt Controls Pavement temperature > 50 degrees and no precipitation is falling and when the outdoor temperature is > 40 degrees, the system shall shut down

Pools Pool heaters shall have a readily accessible shut off switch Gas fired heaters shall not have continuously burning pilot Timers to automatically turn on and off Exception Public Health requires 24 hour operation Pump systems with solar heat recvoery

Fireplaces New wood burning (Masonry) fireplaces shall have gasketed doors and outside combustion air

Lighting Equipment A minimum of 50% of the lamps in permanently installed lighting fixtures shall be high - efficacy Prescriptive method

Simulated Performance Alternative Local official may approve the use of specific computer software programs. i.e. REMrate Includes both envelope and equipment Allows greater flexibility, allows credits such as: High efficiency furnaces Tight ducts that MUST be tested (Duct Blaster) Exterior shading, favorable orientation Table (1) shall be followed strictly Similar to ENERGY STAR Home guidelines

Code official has the final say and must approve: Software chosen Worksheets to be submitted Mandatory requirements are required for this method also Energy prices taken from approved source by code official All work is subject to inspections Certificate is required

Certificate Permanently posted on the electrical distribution panel Don’t cover or obstruct the visibility of other required labels Include the following information R-values of insulation installed for the thermal building envelope including ducts outside conditioned spaces U-factors for fenestration SHGC for fenestration HVAC efficiencies and types SWH equipment

Helpful Websites Department of Commerce and Economic Opportunity (DCEO) DOE Illinois General Assembly Capital Development Board International Code Council

Questions? Thanks for inviting me Don Plass Director of Code Enforcement Village of Hoffman Estates