Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
Digital Current Transformer Reporter
Direct Line Supply ArchWeigh HP Belt Scale Internal Speed Sensor The Most Technologically Advanced In-Motion Scale. Click to Advance.
Watts up ?. NET. Watts up.NET Overview Ideal for remote monitoring, the built-in web server allows data to be accessed via the internet. Connect the.
NEMA. 2 Utility Metering vs. Submetering 10/11/2014 New PowerPoint Template Utility Meter Meter provided by utility with the purpose of measuring.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
…the movement of charge between varying locations and the corresponding loss and gain of energy which accompanies this movement. Unit 4 - Electric Circuits…
Feeder and Main Application
PowerLogic® Factory Assembled Enclosures
What is Energy Monitoring?. Market Direction The lighting control industry being driven to manage energy holistically and to show ROI – Energy costs are.
Simple, accurate tenant sub-metering
© ABB ABB DELTAsingle Commercial and technical presentation.
© ABB ABB ODINsingle Commercial and technical presentation.
PowerLogic Branch Circuit Power Meter (BCPM)
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
PowerLogic® Submetering
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
PowerLogic® E5600 power and energy meter 1.
American Control Technologies,Inc Power Factor Correction Technology 1152 West 2400 South Suite ‘C’ Salt Lake City, Utah
Energy Management System Future Group. How Energy Management System helps  Gives Electrical parameters and energy consumption Section or store wise for.
LUMEN ALARM & LIGHTING SYSTEM Artem Aginskiy, Grayson Carr, Yinuo James Chen, Andrew McDowell.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Powertech UPSC Substation Capabilities. B-tech Developed Battery monitoring system which monitors Substation Batteries The prime objective of this system.
Looking for a more powerful circuit monitor?
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
FG Wilson Access 4000 Control Panel
Invision TAC™ Integrated Telephone Entry and Access Control System Product Introduction June 2010.
IUPS101 Product Overview I Copyright Extronics Ltd 2011 iUPS101 Partner Webinar Ross Tye, Andrew Peek & Paul Lazor 12 th Dec 2011.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
Application Protocol for Veris E30 Panel-board Monitoring System Jaein Jeong UC Berkeley LoCal Workshop Oct 5 th, 2009.
Radian Research, Inc. Radian Research, Inc. an employee owned company Power and Energy Measurement Specialists 3852 Fortune Drive.
Need to enhance your network?
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
PowerLogic® PowerView Software
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Make the most of your energy December 2008 Multi-Circuit Meter Need to monitor multiple electrical services, which share a common voltage source? PowerLogic.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
© 2011 QLC Submetering: Evolution, Technologies, Applications.
Energy Family Power Meter Energy Energy Plus & Energy Pro.
S V.MOUNICA 09551A0294.  To increase the distribution rate of present electric supply which is 70% to 100%.  Improving the supply to house holds without.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
REDA Production Systems
Advanced Meter School August 18-20, 2015 INSTRUMENT TRANSFORMER SIZING 2015 David L. Johnson.
ENERGY METERS DME SERIES
Portable Working Standard
NT24k® & 1000 PoE+ Offerings October 2016.
Christian Elbe Ernst Schmautzer
PowerLogic™ offer for the basic metering market
Introduction to the POWERLOGIC® PM700 Series Power Meters
PowerLogic PM5350 High-performance multifunction power meter
PM9, PM9P and PM9C Power Meter
Meet demanding customer expectations with the right energy meter
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy Meter

Schneider Electric 2 - Marketing – Energy Meter – December 2008 PowerLogic ® Energy Meter ●Stand-alone electrical sub-meter with built in display ●High Resolution Backlit LCD display provides not only valuable energy data but also diagnostic and alarming information ●Optional communications network capability for communications to a PowerLogic system ●1% accuracy for meter system with meter and CT’s being calibrated together. ●Easy to use and install split-core CT’s with self gripping Iris ●Enhanced model has kWh pulse output and phase loss alarm contact - easy interface to Building Automation Systems ●Monitors up to 3 separate circuits with additional CT’s

Schneider Electric 3 - Marketing – Energy Meter – December 2008 Both models offer the same readings Basic Model ●kWh, Energy Consumption ●kW (3 Ph. & Total), Power ●kW Max ●kVAR, Reactive Power ●kVA, Apparent Power ●Power factor (3 Ph & Total) ●Amps (3 Ph & Avg) ●Volts (3 Ph & Avg) ●kW Demand [with EMCB] Extended Range Model ●kWh, Energy Consumption ●kW (3 Ph. & Total), Power ●kW Max ●kVAR, Reactive Power ●kVA, Apparent Power ●Power factor (3 Ph & Total) ●Amps (3 Ph & Avg) ●Volts (3 Ph & Avg) ●kW Demand [with EMCB]

Schneider Electric 4 - Marketing – Energy Meter – December 2008 Model Comparison (Differences in Red) Basic Model ●Hi-Res Backlit Display ●IR port ●Optional Modbus communication card with kWD (interval) ●120/240V and 120/208V services Extended Range Model ●Hi-Res Backlit Display ●IR port ●Optional Modbus communication card with kWD (interval) ●Extended voltage range: V ●kWhr pulse output ●Phase loss output

Schneider Electric 5 - Marketing – Energy Meter – December 2008 Applications ●Commercial tenant submetering ●Multi-residential buildings ●Performance Contracting ●Cost Allocation ●Real time power monitoring via local display or through DCS or PowerLogic systems

Schneider Electric 6 - Marketing – Energy Meter – December 2008 Display ●High resolution backlit display provides energy readings, and diagnostics ●Straight forward information - no need to apply multipliers

Schneider Electric 7 - Marketing – Energy Meter – December /120 VAC, 3-wire three phase EMB3 240 VAC, 3-wire Single phase EMB2 120 VAC, 2-wire Single phase EMB1 System type must be known to order the correct Energy Meter Application wiring examples

Schneider Electric 8 - Marketing – Energy Meter – December 2008 Basic Model

Schneider Electric 9 - Marketing – Energy Meter – December 2008 Extended Range Model

Schneider Electric 10 - Marketing – Energy Meter – December 2008 Options Part Number Description EMCB Energy Meter Communication Board EMFP1Energy Meter Fuse Pack, Set of 1 EMFP2Energy Meter Fuse Pack, Set of 2 EMFP3Energy Meter Fuse Pack, Set of 3

Schneider Electric 11 - Marketing – Energy Meter – December 2008 Dimensions

Schneider Electric 12 - Marketing – Energy Meter – December 2008 Current Transformers ●Factory assembled split-core style ●Four different sizes ●Two smaller sizes are equipped with “self-gripping iris”. ●Color coded to make it easy to match with color coded voltage terminals ●There is no need to be concerned with CT load orientation during installation!

Schneider Electric 13 - Marketing – Energy Meter – December 2008 Size 0 Size 1 CT Dimensions

Schneider Electric 14 - Marketing – Energy Meter – December 2008 Size 3 Size 4 CT Dimensions

Schneider Electric 15 - Marketing – Energy Meter – December 2008 Energy Meter – Easy Installation ●3 Simple Steps ●Mount the meter ●Connect the COLOR CODED voltage leads (fuse kit is a must) ●Connect the COLOR CODED CT’s (auto corrects for reverse CT)

Schneider Electric 16 - Marketing – Energy Meter – December 2008 Energy Meter - Installation

Schneider Electric 17 - Marketing – Energy Meter – December 2008 Energy Meter - Communications ●Modbus Communications ●Easily connect to Power Monitoring or BMS ●Measures Demand/Interval ●2 or 4 wire compatible ●Field Retrofitable

Schneider Electric 18 - Marketing – Energy Meter – December 2008 More Submetering Products ●Multiple Meter Enclosures – HDM ●Available in 1, 4, 8 and 16 meter sizes ●Socket Meters ●Revenue accurate ●On board communications and pulse output ●Multiple socket form factors available ●Tenant Metering Software ●Automatic meter reading and billing generation

Schneider Electric 19 - Marketing – Energy Meter – December 2008 Application Example – which model to specify? ●Customer has a requirement to monitor a 480 Volt 3 phase 4 wire panel with 200 amp feeders. Application requires local readout for kWh ●First the 480V requirement is too high for the Basic model therefore the Enhanced must be selected ●Referring to the list of Enhanced models find the p/n with 3 CT’s rated at 200Amps ●Therefore the correct p/n will be EME3-021 (Enhanced / 3 CT / 200A / size1) ●If the application requires also requires that the meter provide 15 minute kW Demand info via a serial connection to a remote system then the Communications Board would also be required ●p/n would be EMCB ●Make sure to advise the customer to that Fuses are required for proper installation and specify… ●p/n EMFP3 / Energy Meter Fuse Pack, Set of 3

Schneider Electric 20 - Marketing – Energy Meter – December 2008 Literature ●Doc# 3020HO0002R4/08

Schneider Electric 21 - Marketing – Energy Meter – December 2008 Instruction Bulletins Energy Meter Installation Doc# A5 Addendum: Parallel CT Installation Doc# A1 Communication Board Doc# A1

Schneider Electric 22 - Marketing – Energy Meter – December 2008 Submetering Part #’s – Digest Section 4