Clinical Conference 15 Dec 04

Slides:



Advertisements
Similar presentations
Trouble Shooting (Mechanical Ventilation)
Advertisements

New and Old Problems with Anesthesia Equipment BWH Anesthesia Grand Rounds July 9, 2003 © Copyright , James H Philip, All rights reserved.
Getting Started with the EELD601 After you remove your EELD601 from the box, check to make sure you have all accessories shown below. Click here for next.
Getting Started with the EVAPro After you remove your EVAPro from the box, check to make sure you have all accessories shown below. Click here for next.
Next Home Visio2 troubleshooting guide Start the slide show then click Next.
Initial Assessment of the Mechanically Ventilated Patient
ANESTHETIC MACHINES.
Simulated Protected Code Blue Randy Wax, MD, FRCPC Rod MacDonald, RRT Human Simulation Program, Mount Sinai Hospital/ University of Toronto Peter Brindley,
Safety Requirements of the Anesthesia Workstation
Anesthesia Machine Presented by Gil Soto C.R.N.A.
Utility Management Providence Health System - Oregon Environment of Care.
Anesthesia Apparatus Checkout Recommendations
1 © ECRI Institute 2011 Wake up! This is alarming! ALARM FATIGUE Kara Polichetti.
Check Valves and Manufacturer-Recommended Leak Test
Next Home EcoCompact troubleshooting guide Start the slide show then click Next.
6525 EVAP Approved Enhanced EVAP Phase-in % % % % Manufacturers with sales less than 10,000 vehicles.
Scavenging System  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected to a.
Nitric Oxide Set-up for Patients on Ventilator
Quick Reference Guide to Proper Isoflurane Handling and Use EXPOSURE LIMITS: NIOSH recommends an exposure level of 2 parts per million (ppm) that should.
Review NRP part II Lone Star college systems: Kingwood Elizabeth Kelley Buzbee AAS, RRT-NPS, RCP.
Automotive Fuel and Emissions Control Systems 3/e By James D. Halderman Copyright © 2012, 2009, 2006 Pearson Education, Inc., Upper Saddle River, NJ
Clinical Conference: Technology Rounds Biomedical Engineering Evelyn Fan, M.H.Sc., Clinical Engineer Biomedical Engineering November 2, 2005.
Organ Donation End of Life care in the Operating Room Matthew Bock Surgical recovery coordinator University of Wisconsin Organ Procurement Organization.
© , James H Philip, all rights reserved
Technology Topics 2005 CA1 - CA40 focus BWH Anesthesia Clinical Conference August 31, 2005 James H. Philip, MEE, MD, CCE © Copyright 2005, James H Philip,
Clinical Conference Anesthesia Machines don ’ t fail, do they? James H. Philip M(E)E, MD Brigham and Women’s Hospital October 30, 2002 © Copyright 2002,
PART 3: Breathing Circuit
Parts of the Anesthetic Machine
ADVANCE HEALTH CARE DIRECTIVES Margie Dino RN Community Health Resource Center.
Scavenging System A&A Pg 356  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected.
+ Surgical Procedures 7.01 Implement techniques to prepare and monitor patients for surgery.
To Menu.
A Case Study. The background You admitted MB after a LIMA-LAD, SVG x2, initial vital signs were stable – HR 75, BP 114/73, CVP of 5, Cardiac index was.
Pre-operative Assessment and Intra operative Nursing Role
Trouble Shooting (Mechanical Ventilation) Arthur Sadhanandham Medical ICU, CMC.
Waste Anesthetic Gases. The anesthetic gas and vapors that leak out into the surrounding room during medical and surgical procedures are considered waste.
The Relative Exposure of the Operating Room Staff to Sevoflurane During Intracerebral Surgery Anesth Analg 2009;109:
PART 3: Breathing Circuit
Procedures. Chapter 15 page 448 Objectives Spell and define key terms State the purpose of endotracheal intubation and describe how to assist with this.
INFORMATIONAL INTERVIEW Karoline Joyce4/18. Who did I interview? -My dad -Certified Registered Nurse Anesthetist (CRNA) -Works at Wesley Long Hospital.
To Menu.
Anesthetic Problems and Emergencies A&A pg Why Do Problems Arise?  Human error  Equipment error  Adverse effects  Patient factors  Anesthetic.
JCAHO Goal 6 Improve the effectiveness of clinical alarm systems.
Response to Anesthetic Problems and Emergencies We are going to talk about your response to:  Depth of anesthesia issues  Cardiac arrest  Recovery period.
Parts of the Anesthetic Machine A&A Pages
Paramedic Ventilator Management
A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect.
Manual Ventilator Project Peter Ma, Richard Long, Matt Valaskey, Jimmy Fong Client: Michael K. Abernethy, MD, FACEP Advisor: Paul Thompson, PhD
1947 – First Self Service Gas station – Los Angeles First ATM machine – New York 1995 – First Airport Self Check In – Newark, NJ 2013 – First Self.
MEDICAL GAS SYSTEMS Uganda Experience - By Joel O. Akabway Biomedical Engineer, Biomed Systems Centre Ltd, Ntinda the right Connection.
BREATHING SYSTEMS.
VA Palo Alto Continuous Nerve Block Catheter Instructions You have had a nerve block catheter placed for pain control after surgery. It is normal for your.
Agent Monitoring For CEs and BMETs. Ready Anesthetic Agent Monitoring James H. Philip, M.E.(E.), M.D. Anesthesiologist and Director of Technology Assessment.
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
Capnography: Defined and Clinical Applications
ADVANCE HEALTH CARE DIRECTIVES
14 Refrigerant Recovery, Recycling, and Recharging.
Non-Rebreathing System
Act 9 – Device Interoperability Serving Home and Hospital
Anesthesia Manager Training Working with Real-Time Data
Road signs Speed limit No right turn Slippery road No entry
How to Diagnose a Faulty Radiator Pressure Cap
What are the Signs of a Faulty Radiator Pressure Cap.
Alarm Sound Tutorial.
Non-Rebreathing System
Emergency Splenectomy
Auto Bag Jerome H. Santoyo Jessica S. Yeager Advisor: Richard Fries
Harper University Hospital Orientation
Harper University Hospital Orientation
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

Clinical Conference 15 Dec 04 George P. Topulos, M.D. Department of Anesthesia and Perioperative Medicine Brigham & Women’s Hospital

Case Presentation - 1 60 yof o/w well - breast lumpectomy and axillary node mapping Uneventful iv induction and oral ETT Ventilator on, O2/N2O/Desflurane/fentanyl No NMB at request of surgeon Patient movement and BP, Desflurane Several minutes go by Reservoir bag is collapsed No alarms (I think) What would you do now?

Case Presentation - 2 Switch to bag (manual) ventilation Unable to ventilate or fill reservoir bag despite O2 FGF up to max. What would you do now? Call for help Wake up patient and cancel surgery?

Case Presentation - 3 Switch to manual resuscitator (ambu bag) for ventilation Connect to O2 and capnograph! Patient starts to move around Total iv anesthesia What if you could not find manual resuscitator? What would you do now?

Clinical Problem Solving Recognize Best guess at Diagnosis Temporize Mechanism Context Specific Therapy Evaluate Success of Therapy Re-evaluate Diagnosis How bad is it? If the problem is not serious you may want to skip the temporary intervention. "Mechanism" means think about the physiological mechanisms that can cause the problem. "Context" means think about the clinical context (situation) in which it happened. If we find a patient with hypoxemia we must have a way to think about : what could be wrong, how can we distinguish between the possibilities, and how can we make it better. Otherwise we will be forced to memorize a long (and always incomplete) list of potential problems, we will not be likely to discover new kinds of problems, and we will not see how to fix them. Try to think about the fundamental mechanisms behind the problems we see. Think mechanistically and quantitatively. Intuitions are not enough. If I ask what are the causes of hypoxia do not think of a disease; e.g., a PE may release bad humors which in turn may result in hypoxemia, but think of mechanisms not diseases. On the one hand, a model will help guide our thinking through a complicated problem. On the other hand must keep in mind this is only a model, it is oversimplified, incomplete, and probably wrong in ways we do not know. So keep an open and critical (skeptical) mind; the model can also cause us to fail to discover new kinds of problems.

Assign someone to take care of the patient and nothing else! Crisis Management - 1 Assign someone to take care of the patient and nothing else! (fly the plane, point at the man over board) They ignore the equipment problem.

Show Simulator Movie Show Simulator Movie of plane crash

Crisis Management - 2 Don’t panic – do not stare at the anesthesia machine. Don’t ignore it either. “It would be unthinkably awful if this were true so it must not be real.” While you are thinking have the nurse call your staff and say you want them NOW. This is no time for YOU to be on the phone. Do not fixate on a single measurement or monitor look at the other vital signs. Look at the patient and the surgical field. Make sure you have not forgotten something you did. Life is not a multiple-choice test, do all of this in 30 seconds.

Case Presentation - 4 Unable to find leak, clinical engineers, another attending who happened in. Automatic "leak test" OK (and was before case). Disconnect from patient and still a big circuit leak. Switch anesthesia machines? If so how when and with what help? if could not get another anesthesia machine use an ICU vent and iv anesthesia. later point out it was first case of the day (was it)

Causes of Circuit Leaks Involve Patient NG tube Cuff leak ETT out Lung leak Do Not involve Patient Circuit disconnect CO2 canister Vaporizer leak

OR Biomedical Engineering Machine Post-Mortum Jim Philip and OR Biomed Team Page 3-1055 or call 3-1987 Vaporizer - worked without problem on another Fabius Another Vaporizer in same slot created leak on this Fabius No leak with Vaporizer off Big leak with Vaporizer on Why? What happens when the Vaporizer is turned on? 5 minutes, only

SelectaTec® Mounting Vaporizer is out of circuit until switched on That is why cannot be used below the first marking Control Dial Release Selectatec Manifold Vaporizer-specific innards

SelectaTec® Mounting

SelectaTec® Mounting Vaporizer leak will be missed during pre-use check Unless it is turned on Loose vaporizer will leak at connection Only when it is switched on Misalignment of Vaporizer will cause the leak observed Any anterior or posterior movement will do this Alignment peg creates correct alignment

Vaporizer misaligned Purposeful misalignment

Big Leak only when switched on

Vaporizer off and misaligned Purposeful misalignment

No leak detected

Followup Manufacturer (Draeger) informed of “Failure of Pre-use Check” Understood to be interaction of SelectaTec Vaporizers and back bar with Draeger “No Fresh Gas Hose” design Resolution by Manufacturer ? Resolution at BWH Inspect vaporizer mounting Perform additional or primary leak test With desired Vaporizer on

Black Slide

What is wrong with this picture? MRT case cryoablation of kidney tumor. RF Noise in MR images caused by battery charger in infusion pump. Pump plugged in but turned off. Was in the MR room but at least 15 ft from magnet. Get picture of the pump 03 Dec 04 from Paul Morrison There are 3 images: Series 4 image 8: image with artifact Series 4 image 19: image with artifact (changed frequency direction) Series 7 image 7: image with "Topulos filter." <<MRT041202_Ser04 i008.jpg>> <<MRT041202_Ser04 i019.jpg>> <<MRT041202_Ser07 i007.jpg>>  MRT case cryoablation of kidney tumor.