Energy Performance of Buildings Group Heating, Ventilating, & Air-Conditioning: Diagnostics & Controls to Improve Air-Handling System Performance Craig.

Slides:



Advertisements
Similar presentations
HVAC Equipment Efficiency Overview Building Performance Matters.
Advertisements

Chapter 3. HVAC Delivery Systems
PowerPoint ® Presentation Chapter 15 Troubleshooting and Mitigating IAQ Problems Troubleshooting and Mitigating IAQ Problems Overview of Non-IAQ Problems.
Intro to Enersol What is Retro-commissioning? Define Benefits of Retro-commissioning Define Retro-commissioning Process Discuss Retro-commissioning Findings.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Carrier Controls Demand Controlled Ventilation. Comfort = Temperature + Ventilation Comfort Is More Than Just The Right Temperature… Ventilation Control.
North Carolina Crawl Spaces – Vented and Closed ACI Home Performance 2008 Melissa Malkin-Weber.
PERFORMING EFFECTIVE BUILDING SYSTEM RECOMMISSIONING STUDIES Joseph J. Watson, P.E. Booth # 312.
A Comparison of Measure Avoided Cost Calculations using Utility TOU Load Shapes and DEER Hourly Measure Savings 14 March 2006.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Heating, Ventilating, and Air-Conditioning
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Coupling a Network HVAC Model to a Computational Fluid Dynamics Model Using Large Eddy Simulation Jason Floyd Hughes Associates, Inc Fire + Evacuation.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Model predictive control for energy efficient cooling and dehumidification Tea Zakula Leslie Norford Peter Armstrong.
Lab Energy Management Big Ten Mechanical & Energy Conference October
Heating and Air Conditioning I
Objectives Finish with ducts and fans Define project topics.
The House as a System 1. Air Temperature and Water Vapor.
Energy Management with the use of an Intelligent Building Management System.
Standardized Curriculum WAP Training Plans and Resources.
Objectives Blower door and duct bluster measurements - Theory and lab
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
© American Standard Inc Fan Pressure Optimization The Trane Company.
ACTION PROPOSAL FOR FLYWHEEL ENERGY TECHNOLOGY Enhance future grid reliability, interoperability, & extreme event protection In 20 years, the flywheel.
Examples of Commissioning Cost Savings Commissioning for Sustained Building Performance September 29, 2011 Marriott Birmingham, AL.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Phoenix Convention Center Phoenix, Arizona HVAC Re-tuning at GSA and Army Reserve Facilities: A Low-Cost Path to Energy Efficiency and Cost Savings Integrated.
Important variables Water: Air: Conversion:
C A L I F O R N I A E N E R G Y C O M M I S S I O N California Energy Policy: Zero Net Energy Homes in 2020 Martha Brook, P.E. High Performance Buildings.
Lawrence Livermore National Laboratory Building 111 Mike Holda Lawrence Berkeley National Laboratory (510) or (209) ,
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Objectives Finish talking about ways to minimize ventilation losses Discuss role of ducts in building energy use Describe coheating test methodology Interpret.
Basics Air Flow Basics -Air is invisible -Everyone assumes adequate airflow -Frequently airflow is 30%-50% low -Cooling – 400 CFM per ton -Heating.
Ben Larson 1 November th Avenue NE, Seattle, WA (206)
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Second Coming of Delta Q Bob Davis, Ecotope RTF meeting, 7 March 2006.
Objectives Finish air cleaner problem Measure ventilation rates Focus on smaller buildings.
Air quality made simple A Balanced Approach Whole House Ventilation and IAQ Airflow Control Make-up Air Solutions Application by Geographic Region.
Week 9 Common Commercial Building energy efficiency measures (Energy Management Opportunities)
Session 3 Domestic Energy Uses. Recording from utility bills, use schedules and unusual observations Inventory domestic all energy use systems such as:
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Objectives Talk about the final projects Guest Speaker Discuss HW2 and HW3 problems.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Duct Sealing and Insulation TRAIN THE TRAINER WEATHERIZATION.
Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Automating and Integrating Residential Systems Presentation 8 – Ventilation/Furnace Simulation.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
HYDRONIC HVAC: The Most Comfortable and Efficient System
Chapter 6: INFILTRATION
HYDRONIC HVAC: The Most Comfortable and Efficient System
Story of No-Cost Energy Savings at Ohio Union
HCB 3-Chap 19A: All-Air Systems_Single Zone
Objectives Further discuss the Exam problems
Things you need to know before you play the game
Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES
High Performance HVAC Installation
Minimizing Heating & Cooling Costs
Objective Revie the Cooling Cycle Learn about air distribution systems
Chapter 6B: INFILTRATION CALCULATION
Presentation transcript:

Energy Performance of Buildings Group Heating, Ventilating, & Air-Conditioning: Diagnostics & Controls to Improve Air-Handling System Performance Craig Wray, P.Eng. Indoor Environment Department Lawrence Berkeley National Laboratory Tel: American Physical Society Short Course Physics of Sustainable Energy: Using Energy Efficiently and Producing It Renewably UC Berkeley, 1 March 2008

Acknowledgments Assistant Secretary for Energy Efficiency and Renewable Energy, Office of the Building Technologies Program, U.S. Department of Energy California Energy Commission PIER Program Max Sherman, Iain Walker, Darryl Dickerhoff (LBNL) Cliff Federspiel (Federspiel Controls) Energy Performance of Buildings Group

Overview Background –Opportunities for improvement Duct Leakage Diagnosis –Measuring leakage flows using the DeltaQ test Duct Pressure Diagnosis & Control –Demand-based reset with DDC/non-DDC controls Ventilation Control –Intermittent ventilation and efficacy Energy Performance of Buildings Group

Opportunities for Improvement Duct Leakage and Operating Pressure –Thousands of field assembled joints –System pressures not uniform or constant; impossible to know location of each leak and pressure difference across each leak –Unnecessarily closed dampers restrict flow –Large energy savings possible from sealing ducts and optimizing duct static pressures Ventilation –Standards specify constant ventilation rates –Energy intensive process; sometimes can reduce IAQ –Intermittent ventilation more appropriate in some cases Energy Performance of Buildings Group

Overview Background –Opportunities for improvement Duct Leakage Diagnosis –Measuring leakage flows using the DeltaQ test Duct Pressure Diagnosis & Control –Demand-based reset with DDC/non-DDC controls Ventilation Control –Intermittent ventilation and efficacy Energy Performance of Buildings Group

Why Use DeltaQ Duct Leakage Test? Fast and easy –No register covering (less damage potential) –Coincidentally measures envelope leakage –Uses familiar equipment (blower door) –Self-diagnostic for uncertainty –Can be automated Accurate –Leaks to outside under operating conditions BUT… –Need a computer –Need to operate central blower Energy Performance of Buildings Group Pressurizing Airflow

DeltaQ Airflows and Pressures Energy Performance of Buildings Group Air Handler Blower Door DeltaQ = Air Handler OFF 10 Pa Pa Pa Pa 20 Air Handler ON Pa Pa 60 Building Envelope Supply Return

DeltaQ Test Data Green = blower on Red = blower off Difference = DeltaQ Energy Performance of Buildings Group

DeltaQ Model DeltaQ(P)=Q on (P)-Q off (P) Q on (P)=Q env (P) + C s (P+Ps) ns + C r (P-Pr) nr P = Envelope added pressure P s = Supply Pressure P r = Return Pressure C s =Supply leak coefficient C r =Return leak coefficient Q s =Supply leak flow Q r =Return leak flow Q=C(P) n Q off (P)=Q env (P) + C s (P ns ) + C r (P nr ) DeltaQ(P)=C s ((P+P s ) ns -P ns ) + C r ((P-P r ) nr -P nr ) DeltaQ(P)=Q s ((1+P/P s ) ns -(P/P s ) ns ) - Q r ((1-P/P r ) nr +(P/P r ) nr ) Energy Performance of Buildings Group

Pressure Scanning Error Surface Energy Performance of Buildings Group PsPs PrPr Solution at lowest error For each supply and return pressure pair, the least squares error is calculated by comparing the estimated ΔQ to the measured ΔQ Error

Duct Flow Resistance Correction Flow through leak Difference between flow through air handler and flow through ducts Energy Performance of Buildings Group

Overview Background –Opportunities for improvement Duct Leakage Diagnosis –Measuring leakage flows using the DeltaQ test Duct Pressure Diagnosis & Control –Demand-based reset with DDC/non-DDC controls Ventilation Control –Intermittent ventilation and efficacy Energy Performance of Buildings Group

Variable-Air-Volume System Schematic Energy Performance of Buildings Group

VAV System Control Energy Performance of Buildings Group

Duct Static Pressure Reset Issues DDC systems with reset capability already exist, but suffer from: –Inaccurate, open-loop position measurement –Failures at terminal boxes –Limited bandwidth and limited programming capabilities Many systems have pneumatic terminal controls Using total supply airflow signal from airflow station expands reset applicability Aggregation of terminal box flows makes control more robust to single terminal failure Energy Performance of Buildings Group

Diagnostic Principle Terminal flows are regulated by thermostat, independent of duct static pressure Test Procedure –Start at high pressure –Incrementally lower pressure –Record flow signal at each step Complicating Issues –Flow stabilizes slowly –Zone temperatures can change –Noisy measurements –Ducts leak (pressure-dependent) Energy Performance of Buildings Group

Diagnostic: Dual-Model Estimation Model components 1.Constant component 2.Time-varying component 3.Leakage flow 4.Starved behavior “In-Control”: “Starved”: At critical pressure, both models predict same flow; solve for transition using least squares fit Energy Performance of Buildings Group

Haas School of Business Energy Performance of Buildings Group

UCOP

County of Alameda Energy Performance of Buildings Group

Overview Background –Opportunities for improvement Duct Leakage Diagnosis –Measuring leakage flows using the DeltaQ test Duct Pressure Diagnosis & Control –Demand-based reset with DDC/non-DDC controls Ventilation Control –Intermittent ventilation and efficacy Energy Performance of Buildings Group

Intermittent Ventilation: When Steady Won’t Always Do Ventilation (for acceptable IAQ) should not always be constant May be periods of the day when outdoor air (OA) quality is poor and one wishes to reduce amount of OA entering building Economizer operation can over-ventilate a space from IAQ point of view; energy savings can be achieved by reducing ventilation rates at other times to account for over-ventilation Demand charges or utility peak loads may make it advantageous to reduce ventilation for certain periods of the day Some HVAC equipment may make cyclic ventilation more attractive than steady-state ventilation –Example: residential or small commercial systems that couple ventilation to heating and cooling system operation Energy Performance of Buildings Group

What’s The Problem? Constant target ventilation (A eq ) Intermittent ventilation with cycle time (T cycle ), over-ventilation (A high ) for fractional time f high, and under-ventilation (A low ) for fractional time f low Equivalency = same dose for constant contaminant source –Sherman & Wilson (1986); Std 136 Means to demonstrate equivalency not obvious: –Designers want flexibility to use intermittent ventilation, but also want to follow standards & guidelines –Average not always same as constant Energy Performance of Buildings Group

Efficacy is Link Provide calculation method to assess equivalency –Find the temporal ventilation effectiveness (“efficacy”) of a given pattern of ventilation Definition: Typical Use: Energy Performance of Buildings Group

Hyperbolic Cotangent? Nominal Turnover: Fraction of time under-ventilated: f low Recursive equation numerical solution Use efficacy for design Energy Performance of Buildings Group

Air Change Rates & Turn-Over Times ach (1/h) Turn-Over Time (h)DESCRIPTION Infiltration rate of new homes Infiltration rate of commercial buildings Ventilation requirement of almost empty commercial buildings [from Std ] Office space requirement [from Std ]; also large home [from Std ] Ventilation requirement for small homes Infiltration rate of older homes Conference room requirement [from Std ] High density space (e.g., theater lobby) Energy Performance of Buildings Group

Efficacy Trends Energy Performance of Buildings Group N<<1 N>>1 f low

Energy Performance of Buildings Group

ε > 90% for region to left and below each curve

Energy Performance of Buildings Group Low-Density Spaces High-Density Spaces

Energy Performance of Buildings Group

Questions? Background –Opportunities for improvement Duct Leakage Diagnosis –Measuring leakage flows using the DeltaQ test Duct Pressure Diagnosis & Control –Demand-based reset with DDC/non-DDC controls Ventilation Control –Intermittent ventilation and efficacy Energy Performance of Buildings Group