Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum Fundamentals Lecture 5 G.J. Mankey

Slides:



Advertisements
Similar presentations
Vacuum Science and Technology in Accelerators
Advertisements

Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
Vacuum System Design Considerations Materials Plumbing –Pumping –Throughput Ultimate pressure –Dynamic equilibrium –Pumping speed –Leaks.
Overview of Vacuum Systems Tejas Deshpande 24 July, 2014.
Vacuum Fundamentals High-Vacuum Technology Course Week 8 Paul Nash HE Subject Leader (Engineering)
High-Vacuum Technology Course
Vacuum increases the mean-free-path of gas molecules.mean-free-path Vacuum prevents chemical reaction. Vacuum removes contaminants from surfaces.contaminants.
Center for Materials for Information Technology an NSF Materials Science and Engineering Center Sputter Deposition Lecture 9 G.J. Mankey
L.B. Begrambekov Plasma Physics Department, Moscow Engineering and Physics Institute, Moscow, Russia Peculiarities, Sources and Driving Forces of.
Vacuum at CEBAF Seminar for Accelerator Operators 17 January, 2006 Marcy Stutzman and Philip Adderley.
Vacuum equipment. Pumps Rotary vane pumps Rotary piston pumps Roots pumps Turbo molecular pumps Diffusion pumps Getter pumps –Sublimation pumps.
Why Is There Vacuum? (The sequel to Bill Cosby’s “Why Is There Air?”) Matthew C. DeLong University of Utah OptoElectronic Materials Laboratory 7 January.
Vacuum Technology Need for Vacuum Environment
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Vacuum systems Electron beam – mean free path: Gun – column - sample Signal detection – electron and X- ray collection: Scattering of emitted electrons.
Basics of Vacuum Technology Unit: Pa = N/m 2 = J/m 3 UnitPa or N/m 2 bar10 5 mbar100 atm= 760 torr x 10 5.
Why Is There Vacuum? (The sequel to Bill Cosby’s “Why Is There Air?”) Matthew C. DeLong University of Utah OptoElectronic Materials Laboratory 5 March.
Pressure Measurement Muhajir Ab. Rahim
P=n 0 k B T or n 0 =p/k B T ideal gas atom density 2.69 × m −3 at normal conditions ( K and kPa) k B the Boltzmann constant, T the.
Thin Film Deposition Prof. Dr. Ir. Djoko Hartanto MSc
BISMV & H 0 -H - PSB INJECTION VACUUM REQUIREMENTS LIU - PSB meeting 29th October 2012 C. Pasquino, P. Chiggiato, J. Hansen.
Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum Evaporation Lecture 8 G.J. Mankey
Vacuum, Surfaces & Coatings Group Technology Department Vacuum tests for CLIC module prototypes 6 November 2013 C. Garion2 Outline: Reminder: specification.
Photoelectron Spectroscopy Lecture 5 – instrumental details –General spectrometer design –Vacuum generation and measurement.
High-Vacuum Technology Course
Pressure 1 atmosphere ~ 1 bar ~ 760 mm Hg ~ 760 torr ~ 100,000 Pa Ion gauges read in mbar i.e. 1x mbar = 1x atm. Sometimes ion gauges read.
Center for Materials for Information Technology an NSF Materials Science and Engineering Center Thin Film Processing Gary Mankey MINT Center and Department.
Solar Cell conductive grid and back contact
Methods in Surface Physics Experimentation in Ultra-High Vacuum Environments Hasan Khan (University of Rochester), Dr. Meng-Fan Luo (National Central University)
20-21 January 2009, RAL Joint DL-RAL Accelerator Workshop 1 INVESTIGATION OF NON- EVAPORABLE GETTER FILMS O. B. Malyshev, K.J. Middleman, A. Hannah and.
Vacuum science.
Reference book: Building Scientific Apparatus A practical guide to design and construction by John H. Moore, C. C. Davis and M. A. Coplan 2ed or 3rd edition.
Methods and Tehniques in Surface Science Prof. Dumitru LUCA “Alexandru Ion Cuza” University, Iasi, Romania.
Vacuum Fundamentals 1 atmosphere = 760 mm Hg = kPa 1 torr = 1 mm Hg vacuum range pressure range low 760 ~ 25 torr medium 25~ high ~ 10.
PHYSICS 225, 2 ND YEAR LAB VACUUM TECHNOLOGY G.F. West Thurs, Jan. 12.
Techniques of Vacuum and Basics of High Voltage (2/3) Pauli Heikkinen Jyväskylä University.
Vacuum Fundamentals High-Vacuum Technology Course Week 6 Paul Nash HE Subject Leader (Engineering)
Vacuum Fundamentals 1 atmosphere = 760 mm Hg = kPa 1 torr = 1 mm Hg vacuum range pressure range low 760 ~ 25 torr medium 25~ high ~ 10.
High-Vacuum Technology Course
Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum Systems Lecture 6 G.J. Mankey
Vacuum Workshop on Vacuum Systems for Synchrotron Light Sources, Barcelona, Vacuum Technology, 12 th and 13 th September 2005 L. Schulz Introduction Pumps.
Reminders Quiz#2 and meet Alissa and Mine on Wednesday –Quiz covers Bonding, 0-D, 1-D, 2-D, Lab #2 –Multiple choice, short answer, long answer (graphical.
Vacuum Fundamentals High-Vacuum Technology Course Week 7 Paul Nash HE Subject Leader (Engineering)
Vacuum Technology.
Top Down Method Vacuum Applications in Nanomanufacturing Author’s Note: Significant portions of this work have been reproduced and/or adapted with permission.
Center for Materials for Information Technology an NSF Materials Science and Engineering Center Substrate Preparation Techniques Lecture 7 G.J. Mankey.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Solar Cells need a top side conductor to collect the current generated They also need a conductive film on the backside.
1 Vacuum chambers for LHC LSS TS Workshop 2004 Pedro Costa Pinto TS department, MME group Surface Characterization & Coatings Section.
Outgassing Test and the Getter Specification
Section 5: Thin Film Deposition part 1 : sputtering and evaporation
Vacuum Technology and Components for Cryogenics
Leak Detection method for Vacuum Systems Alexander Permogorov
Jari Koskinen 1 Thin Film Technology Lecture 2 Vacuum Surface Engineering Jari Koskinen 2014.
Solar Cells need a top side conductor to collect the current generated They also need a conductive film on the backside.
Vacuum Systems for Electron Microscopy Constraints on Specimens Specimens placed in the electron microscope must be able to withstand very high vacuum.
Pressures and Pumps Andy Therrien 1/9/17.
Chemistry 13.1.
Holders and Pumps Summary
Modern Devices: Chapter 4 – Vacuum Systems
© 1997, Angus Rockett Section I Evaporation.
SAES Project: Combination of NEG module and sputter ion pump
K. H. Lee, H. Y. Lee, Young-Gi Kim, J. Yang, S. M. Yang, K.J. Chung, Y.S. Na and Y. S. Hwang Residual Gas analysis during Glow discharge cleaning, Baking.
V. Measurement pressure gauges, flow meters
Thermal Outgassing Rate for Various Beam Line Materials
-Honors Thesis Defense- In Situ Ellipsometry of Surfaces in an Ultrahigh Vacuum Thin Film Deposition Chamber Joseph Choi Department of Physics and Astronomy,
Plasma Cleaning Safety Presentation
Sincrotrone Trieste S.C.p.A.
VIII. Production of Vacuum
BASIC VACUUM PRACTICE.
Presentation transcript:

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum Fundamentals Lecture 5 G.J. Mankey

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum A vacuum is defined as less than 1 Atmosphere of pressure. 1 Atm = 10 5 Pa = 10 3 mbar = 760 Torr Below Torr, there are more gas molecules on the surface of the vessel then in the volume of the vessel. High Vacuum < Torr Very High Vacuum < Torr Ultra High Vacuum < Torr 760 mm Hg Vacuum ATM

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Why do we need a vacuum? Keep surfaces free of contaminants. Process films with low density of impurities. Maintain plasma discharge for sputtering sources. Large mean free path for electrons and molecules ( = 1 7 x mbar). Mean free path for air at 20 ºC: = 7 x cm / P(mbar)

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Monolayer Time We define the monolayer time as the time for one atomic layer of gas to adsorb on the surface:  = 1 / (SZA). At 3 x Torr, it takes about one second for a monolayer of gas to adsorb on a surface assuming a sticking coefficient, S = 1. At Torr, it takes 1 hour to form a monolayer for S = 1. For most gases at room temperature S<<1, so the monolayer time is much longer. Impingement rate for air: Z = 3 x P(Torr) cm -2 s -1 Sticking Coefficient S = # adsorbed / # incident Area of an adsorption site: A  1 Å 2 = cm 2

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum Systems A vacuum system consists of chamber, pumps and gauges. Chambers are typically made of glass or stainless steel and sealed with elastomer or metal gaskets. Pumps include mechanical, turbomolecular, diffusion, ion, sublimation and cryogenic. Gauges include thermocouple for 1 to mbar and Bayard- Alpert for to mbar.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Pressure Ranges Rough vacuum >1 mTorr –Rotary vane pump –Thermocouple, Pirani or Capacitance Manometer Medium Vacuum Torr < P < 1 mTorr –Cryo pump, Diffusion Pump, Turbo Pump, Ion pump –BA Ion gauge, mass spectrometer –Viton seals High to Ultra High Vacuum Torr < P < Torr –All Metal Seals –Baked system –BA Ion Gauge, mass spectrometer –Turbo, Ion, Titanium Sublimation Pump,Cryo pump. *O’Hanlon, Users Guide to Vacuum Technology, Wiley (1980).

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vapor Pressure Curves The vapor pressures of most materials follow an Arrhenius equation behavior: P VAP = P 0 exp(-E A /kT). Most metals must be heated to temperatures well above 1000 K to achieve an appreciable vapor pressure. For P VAP = mbar, the deposition rate is approximately 10 Å / sec. Organic materials have much higher vapor pressures than metals. Care must be taken as to what materials are placed in the vacuum environment.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Materials in Vacuum Outgassing of materials can be the limiting factor in achieving good vacuum. –It is usually best to use all stainless steel, aluminum, glass and copper. –Elastomer gaskets and o-rings should be specifically manufactured for vacuum applications. NEVER USE: –Brass, zinc, or other alloys without first looking up the outgassing rate (should be less than W/m 2 ). *O’Hanlon, Users Guide to Vacuum Technology, Wiley (1980).

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Permeability and Other Gas Sources A single viton seal on a flange, gate valve bonnet or pump inlet will limit the ultimate pressure to >10 -9 mbar. Unbaked systems will rarely reach better than mbar. Trapped volumes or virtual leaks will increase pump down time. Microscopic air leaks can limit the ultimate pressure. The use of a mass spectrometer on a regular basis will help to identify the nature of the gas source.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Pumping Speed Pumps, valves, connections, and hoses all should have compatible pumping speeds. Both pumpdown time and ultimate pressure can be limited by pumping speed. Calculations of pumping speeds of fittings and flanges can be made from the formulae in O’Hanlon and the Ificon vacuum guide.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Rough Vacuum and Leaks During roughing, a large leak can be detected by a hissing sound. Slightly smaller leaks make a sound when liquid (acetone or isopropanol is squirted on them). Once the thermocouple gauge starts to read a vacuum, and if it “gets stuck” at a pressure higher than normal, application of acetone to a leak will cause the reading to fluctuate. Never switch on an ion gauge until you are confident the pressure is below mbar. Application of acetone to a leak will also register on the ion gauge in the pressure range of to mbar. A He leak detector can be used below mbar.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center 1 cm e- Bayard-Alpert or Ionization Gauge Electrons, e-, produced by the hot filament are accelerated through the grid acquiring sufficient energy to ionize neutral gas atoms, n. The ionized gas atoms, I+, are then attracted to the negatively, biased collector and their current is measured with an electrometer. Typical ion gauges have a sensitivity of 1-10 Amp / mbar and range of mbar. Electrometer +150 V -45 V 6 V AC e- n n n n n n n n I+ Filament Collector Grid

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Residual Gas Analysis A quarupole mass spectrometer analyzes the composition of gas in the vacuum system. The system must be “baked” at ºC for 24 hours to remove excess water vapor from the stainless steel walls. The presence of an O 2 peak at M/Q = 32 indicates an air leak. At UHV the gas composition is H 2, CH 4, H 2 O, CO and CO 2.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum System Schematic Symbols Hand Operated Valve. Gate Valve. Pneumatic Gate Valve. Leak Valve. Butterfly Valve. Pneumatic Butterfly. Bellows. Sorption Trap. Vacuum Gauge. Rotary Pump Turbomolecular Pump. Ti Sublimation Pump. Ion Pump. Cryo Pump. *Inficon Instrumentation Catalog,

Center for Materials for Information Technology an NSF Materials Science and Engineering Center Alabama Deposition of Advanced Materials\ ADAM All materials are either glass, ceramics, stainless steel, copper and pure metals. Two turbomolecular pumps create the vacuum—under construction. Sputtering sources are used for deposition. Characterization methods include LEED, RHEED, and AES. Sample can be ion bombarded and annealed.

Center for Materials for Information Technology an NSF Materials Science and Engineering Center ADAM Vacuum Plant