Designing a Gas Detection System

Slides:



Advertisements
Similar presentations
MATERIAL SAFETY DATA SHEET
Advertisements

Flash Point-Ignition Point
MDPI/GOODWILL OIL AND GAS TRAINING
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
Sensor Operating Theory
1926 Subpart J Establishes the requirements for welding and cutting in the construction industry Establishes requirements for equipment, fire protection,
First Responder Basic SAR Training May 2011 Module 3: Safety.
Environmental Health Issue- Carbon Monoxide Presented by QBE Loss Control Services.
PROPERTIES OF FLAMMABLE MATERIALS. Flammability Flammable Flammable –Capable of being ignited and of burning –Synonymous with combustible.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Codes and Standards to be followed in the design and construction of the Green Energy facility National Fire Protection Assoc (NFPA); American Gas Association.
CONSUMED BY FUMES HAZARDS OF AGRICULTURAL GASES. Learning Objectives Understanding the types of respiratory hazards Identifying hazardous atmospheres.
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
Lab Inspections State Fire Marshal’s Office. Applicable Codes 1999 BOCA Business Occupancy 1999 BOCA Fire Prevention Code 2000 NFPA 101, Life Safety Code.
Fires and Explosions.
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
Safe Handling of Flammable and Combustible Liquids
HMT 1C 24-1 u Chapter 24 –Fixed Facility Incident Consideration Haz Mat Incident Considerations.
PERMIT REQUIRED CONFINED SPACES PERMIT REQUIRED CONFINED SPACES.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Safety Unit Lesson 7. Welding fires are caused by sparks, slag, and torch flames. Fires can also happen when combustible materials come in contact with.
Copyright © Flammable & Combustible Liquids.
Standard 29 CFR Part Flammable & Combustible Liquids.
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
Patrick Thornton, SNS/FPE June 9, 2008
EGRESS AND FIRE PROTECTION
1 BUILDING TRADE SAFETY CONFINED SPACES. 2 BUILDING TRADE SAFETY Confined spaces.
WELCOME TO Gas Tester Training O2, LEL Monitoring
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
Hazard Communication. SAFETY The purpose of OSHA Hazard Communication Standard is to ensure that the hazards of all chemicals produced or imported are.
Flammable and Combustible Liquids
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
Safe Operation of Storage Tanks: Decommissioning and Repair
Florida Operations Level Hazardous Materials Training Unit 2.2 Physical and Chemical Properties.
Chapter 2: Chemical Properties and Information Resources on Hazardous Chemicals.
Air Conditioning International Mechanical Code
CONFINED SPACE We are going to start this class with a small quiz. The purpose of the quiz is to allow you to determine where you are and what you know.
1 CXS490 - Characteristic of Fire. 2 Other Resources NFPA Standards (available through Seneca Libraries Link NFPA Handbook Manufacturer’s Technical Information.
PLANT DESIGN.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
SECTION 2 TERMINOLOGY. HAZARDOUS MATERIALS PROPERTIES.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Explosion An explosion is a rapid expansion of gases resulting in a rapid moving pressure or shock wave. The expansion can be mechanical or it can be.
General Monitoring Practices Sugar Grove Fire Department Training and Education.
MINE GASES. Normal Air is made up of: Nitrogen 78% Oxygen 21% Trace Gases 1%
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
Unit 4: General Safety Practices
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Acetylene Storage in Enclosed Vehicle Compartments Thomas Kamm, P.Eng. Safety Engineering Specialist.
Unit 2: Fire Safety and Utility Controls
© 2012 Delmar, Cengage Learning Chapter 11 Engineering Controls.
Confined Space Rescue Level I Technical References: Mod 3.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
Fire Detector Placement
Samuel Nii Tettey (Ergonomist). At the end of Session, participants should be able to: - Identify fire problems at the enterprise level and Conduct Fire.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Hazards of Confined Spaces. INSTRUCTIONAL GOAL The participant till understand the various hazards associated with confined space entries and the need.
Confined Space Hazards. What is a Confined Space? A confined space is a space that: –Is large enough and so configured that a person can bodily enter.
Flammable Liquids Directorate of Training and Education
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
Excavation & Trenching Awareness Plus
Mine Gases. Normal Air Is: Nitrogen 78% Oxygen 21% Trace Gases 1%
Safe Handling of Flammable and Combustible Liquids
Flammable and combustible liquids
Principles of Natural Gas
Flammable & Combustible Liquids
Safe Handling of Flammable and Combustible Liquids
HAZOP Guidewords Base Set
Presentation transcript:

Designing a Gas Detection System

Why Gas Detection? Safeguard Life and Property. Provide Early Warning of Hazardous Conditions. Provide Opportunity for Evacuation and Notification from Re-entry Provide Time for Intervention and Correction. Trigger Facility Protection Systems. Ventilation, Water Mist, Fire Suppression. Satisfy Local Fire Code and Provide Insurability. Address Real and Perceived Safety Concerns. Note: Gas Detection is “Recommended Practice,” “Required by Code,” or “Required by Law.”

Points to Consider Understand the application Identify potential danger points Establish design goals Determine gas characteristics Profile the plant and potential release scenarios Other elements in selecting gas detection systems Actual placement of detection Indoors Outdoors

Understand The Application The gases to be monitored Toxic (STEL, TLV, TWA) Combustible (LEL, UEL) Exposure limits Density and Other Gas Properties Local and federal regulations Uniform Fire Code Code of Federal Regulations Local Fire Marshal

Identify Potential Danger Points Release Points – sensors should be placed as close as possible to potential leak sources. Seals and flanges, fittings and welds Expansion joints and gaskets Engine combustion Storage, loading and unloading areas Runoff areas Decomposing materials Receptor Points – a gas detection notification system should protect any person, property or equipment that may come in contact with harmful gases. Wind direction Ventilation systems Run off areas Confined spaces Communities and facilities

Establish Design Goals Initiate a response based on an early warning of a potential problem. Notification or annunciation – method of warning Ventilation control Process shutdown Evacuation and emergency response Amount of confinement - over pressurization and accumulation Run-up distance – speed of flame increases with distance Amount of congestion or obstacles Fuel quantity and mixing Margin of safety – distance between leak source and receptors Plant safety process Insurance requirements

Determine Gas Characteristics LEL, UEL, Toxicity Vapor density Density differences with temperature Cryogenic liquids, flammable liquids Low density gases displacing ambient density gases (helium vs. oxygen) Gases under pressure will condense in areas where vented first Gases changing composition – dry ice Toxicity vs. flammability (MTBE 40 PPM 1.6% LEL) Hydrolyzed (BF3, F2) Pyrolyzed (NF3) Flash point - the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material. Rate of evaporation and dispersion characteristics Gas mixing (fuel, oxygen, ignition source) Oxygen enriched environments

Gas Hazards There are three main types of gas hazard Flammable Toxic Risk of fire and or explosion, e.g. Methane, Butane, Propane Toxic Risk of poisoning, e.g. Carbon Monoxide, Hydrogen Sulfide, Chlorine Asphyxiant Risk of suffocation, e.g. Oxygen deficiency, Nitrogen, Carbon Dioxide

FIRE Flammable Risk Fire Triangle Three factors are always needed to cause combustion: A source of ignition Oxygen Fuel in the form of a gas or vapour fuel oxygen heat FIRE

Flammable Risk The operation of a car’s choke illustrates an important part of flammable gas hazards All flammable gases are only ignitable over their flammable range Flammable gases tend to be measured in percentage of their explosive Limit (%LEL) 100% v/v gas 0% v/v air too rich U.E.L. (upper explosive limit) flammable range L.E.L. (lower explosive limit) too lean 0% v/v gas 100% v/v air

Toxic Risk Some gases are poisonous and can be dangerous to life at very low concentrations. Some toxic gases have strong smells like the distinctive ‘rotten eggs’ smell of H2S Others are completely odourless like Carbon Monoxide

Toxic Risk The measurement most often used for the concentration of toxic gases is parts per million (ppm). For example 1ppm would be equivalent to a room filled with a total of 1 million balls and 1 of those balls being red. The red ball would represent 1ppm. 1 million balls 1 red ball

Profile the Plant and Potential Release Scenarios Gas sensors should be placed to ensure that a quantity of gas will past by them in all normal release scenarios. Identify physical features of plant Identify ventilation tracks Identify escape routes Protect entrances to areas Mark escape routes Identify wind directions

Other Elements Accessibility for calibration and maintenance Wiring and installation Environmental conditions EMI and RFI Alarm levels Exposure limits Oxygen levels – some toxic gas electrochemical sensors require a minimum oxygen level to function. All catalytic bead combustible detectors require oxygen to work. Be aware of poisoning and inhibiting factors

Interior Detector Placement Guidelines Operate Detectors Within their Temperature Limits. Use Sample Draw or Duct Mount Configurations When Needed Water, Moisture, Dust and Dirt May Affect Performance. Minimize Exposure and Protect From Adverse Conditions Locate Detectors With Respect to Grade, Floor, or Operating Level - According to Building Design, HVAC System, Characteristics of Potential Leak When Monitoring Specific Equipment, Place Detectors Near (12 Inches) Pump, Seal, Tank, Valve, etc. Sensitivity of Detector Depends on Proximity to Leak. Adjust Alarms if Earlier Annunciation is Required Mount Detectors Securely, Independent of Vibration, With Weather Shield Facing Downward Conduct Smoke Trace Behavior Studies If in Doubt

Detector Spacing Indoors There are Few Published Guidelines and No Standards Indicating Area or Volume Effectively Protected By a Diffusion Sensor. There is a Corollary in Fire Protection UL Suggests a 900 Ft2 Ceiling Space Per Smoke Detector, Which is a 30 Ft. Square or 15 Ft. Radius Using This Base Guideline, the Total Number of Detectors Must be Based on Gas Dispersion Characteristics and Air Movement Potential Leak Source Locations and Characteristics, Sources of Ignition Locations Interior Space Division by Walls or Barriers Economics of the Procurement

Detector Spacing Indoors, Cont’d. UL Suggests a 900 Ft2 Ceiling Space Per Smoke Detector 30 Feet 15 Feet Detector Detector References NFPA 72 E, Standard On Automatic Fire Detectors Schaeffer, M.J., “The Use of Combustible Detectors in Protecting Facilities from Flammable Hazards,” ISA Transactions, Volume 20, No. 2, Instrument Society of America 1981

Indoors Lab Bench 40 feet Door Ceiling Ventilation Natural Gas 20 ft STORAGE Lab Bench Cl2 Door LN2 Window

Outdoor Detector Location Guidelines Use same considerations outdoors as indoors. Consider Angle and Direction of Prevailing Wind The Orientation of Structures and Surrounding Terrain with Regard to Shielding Affects The Proximity of Large Quantities of Toxics to Personnel and Equipment, Which May Require Added Detectors to Isolate the Two

Outdoor Detector Location Guidelines Possible Entrapment of Leaking Gases and Vapors Within Columns, Low Lying Areas or Confined Spaces Sources of Ignition and Processes With Fugitive Leak Potential Are Considered for Detector Placement

Outdoor Detector Location, Cont’d. Heavier Than Air Gases or Vapors: Vapor Density >1 The Preferred Location for Detectors is ~18 Inches Above Grade. For Liquid Spills, As Close to the Vapor/Liquid Interface as Possible, and Still Allow for Detector Calibration Lighter Than Air Gases and Vapors: Vapor Density <1 The Preferred Location for Detectors is About 6 to 8 Feet Above Grade or Operating Level, With Special Attention Being Paid to Air Currents, Structures, Roofed Areas, Etc.

Detector Spacing Outdoors Few Guidelines Exist for Detector Placement An Increased Grid Density is Used Outdoor Presumably Because of the Greater Potential for Leak Dilution Thus, More Detectors Are Required, and Potential Leaks Are Encircled, to Account for Wind Shifts

Detector Spacing Outdoors Repeat Outdoor Grid Pattern as Conditions Warrant. Focus on Potential Leak Sources for Additional Detectors if Required 20-30 Feet 10-15 Feet Detector Detector

General Location Considerations Toxic Gases and Vapors: Identify Potential Leak Sources, Work Areas, and Exit Points. Understand Where People are Performing Their Work and Place Detectors Between Probable Release Points and the Work Area

General Location Considerations Allow Access for Sensor Calibration and Replacement. Sensors Have a Finite Life - Calibrate and Maintain Regularly! Always Locate Detectors Using “Local Conditions Knowledge,” and Lighter or Heavier Than Air Principles

General Location Considerations Locate Detectors Within Their Temperature Rating Avoid Exposure to Sources of High Radiant Heat Keep Detectors Away From Moisture and Chemicals Avoid Vibration and Mechanical Shock Hazards Observe Recommended Wiring and Tagging Practices Use Shielded Cable Whenever Possible and Follow Correct Grounding Practices (NFPA 70) Observe Proper Detector Mounting Orientation

Detector Location and Area Coverage Map IMPORTANT Detectors should be located close to any potential leak source and between leak source and any potential source of ignition existing at the monitored site. DETECTOR LOCATED ON TOP OF TANK NEAR VALVE OR FLANGE ON FILL LINE FILL LINE TANK SUPPORT LEGS SIDE VIEW OF STORAGE TANK FILL LINE OUT FLOW XNX-Optima TOP VIEW OF STORAGE TANK DETECTORS SHOULD BE LOCATED BELOW TOP OF DYKE WALL FOR VAPORS THAT ARE HEAVIER THAN AIR. Sensor should be approx 12-18 in above grade. These vapor densities are greater than air.

Detector Location and Area Coverage Map TOP VIEW OF STORAGE TANK Detector Location and Area Coverage Map IMPORTANT Detectors should be located close to any potential leak source and between leak source and any potential source of ignition existing at the monitored site. DETECTOR LOCATED ON TOP OF TANK NEAR VALVE OR FLANGE ON FILL LINE FILL LINE TANK SUPPORT LEGS XNX-Optima FILL LINE OUT FLOW DETECTORS SHOULD BE LOCATED BELOW TOP OF DYKE WALL FOR VAPORS THAT ARE HEAVIER THAN AIR. Sensor should be approx 12-18 in above grade. These vapor densities are greater than air. SIDE VIEW OF STORAGE TANK

Detector Location and Area Coverage Map IMPORTANT: This is intended as a General Application Note and NOT as the sole source of information in determining quantity and location for detector placement. Consult additional resources when developing a monitoring system. Additional information is available for developing Combustible Gas Detection systems, such as: The National Fire Protection Association, NFPA 52 and the Instrument Society of America, ISA-RP12.13-Part II-1987. Services are also available from Professional Safety Engineering Firms and should be utilized whenever necessary DETECTORS SHOULD BE LOCATED BELOW TOP OF DYKE WALL FOR VAPORS THAT ARE HEAVIER THAN AIR. Sensor should be approx 12-18 in. above grade.. SIDE VIEW OF TANK 4 5 6 7 8 TOP VIEW OF THREE AND TWO TANK AREA IMPORTANT Detectors should be located close to any potential leak source and between leak source and any potential source of ignition existing at the monitored site.

Detector Location and Area Coverage Map R.R. SPUR NO. 13 R.R. SPUR NO. 12 TOP VIEW OF UNLOADING FACILITY IMPORTANT Detectors should be located close to any potential leak source and between leak source and any potential source of ignition existing at the monitored site. NOTE: DETECTORS SHOULD BE LOCATED LOW, CLOSE TO GRADE FOR VAPORS THAT ARE HEAVIER THAN AIR. NOTE: Sensor should be approx. 12-18 in. above grade. These vapor densities are heavier than air. SIDE VIEW OF UNLOADING FACILITY I NOTE: IF PIPING FUNCTIONS OR VALVES ARE ABOVE THE TANK CAR A DETECTOR MAY BE MOUNTED PART WAY DOWN THE WALL TO DETECT FALLING VAPORS FROM A LEAK SOURCE

Publications to Reference Chemical Weekly, 2008, “Key Considerations when Designing a Gas Detection System” ISA Recommended Practices ACGIH: Annual TLV and BEI Guide 1330 Kemper Meadow Drive, Cincinnati OH 45240-1634 NFPA/ANSI Guides, Standards and Practices 1 Batterymarch Park, Quincy MA 02269-9101 NIOSH: Pocket Guide to Chemical Hazards Available by FAX Request to (513) 533-8573 OSHA, CFR 29, Section 1910.1000, Subpart Z“Working in Confined Spaces.” NIOSH1 Publication 80-106 “A Guide to Safety in Confined Spaces.” NIOSH Publication 87-113 “ALERT: Request for Assistance in Preventing Occupational Fatalities in Confined Spaces.” NIOSH Publication 86-110

The End Questions?