ACCA Legislative Conference Underground Storage Tank Compliance

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

Spill and Overfill Prevention
Our Vision – Healthier Kansans living in safe and sustainable environments.
ANNUAL SPILL PREVENTION CONTROL AND COUNTERMEASURE TRAINING (SPCC) Presented by: Prepared for: Stephen F. Austin State University February 2, 2012.
Passive Leak Detection Operation Training October 2014.
Petroleum Equipment Institute
Southwest District Storage Tanks Program presented by Leslie Pedigo Southwest District Storage Tanks Program presented by Leslie Pedigo.
1 MASSACHUSETTS UNDERGROUND STORAGE TANK (UST) PROGRAM Baseline Compliance Assessment 1 MassDEP 8/2/2011.
PRODUCT LINE LEAK DETECTION Katie Seaborn AMERICAN CONTAINMENT SERVICES, INC. ® Annual GTEC Underground Storage Tank Management & Compliance Seminar -
Plans and Preparations for the PST Energy Act Investigations Texas Commission on Environmental Quality Environmental Trade Fair May 5-6, 2015.
Virginia UST Operator Training A B & C
WYOMING WATER QUALITY RULES AND REGULATIONS (WQRR), CHAPTER 17
OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L
Overview of the 1.
MassDEP Underground Storage Tank Program Program Requirements for Third Party Inspectors Winter 2015 Workshops.
Release Reporting. Lesson #17 - Release Reporting How Do I Know If I Have a Leak in My UST System?
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by B. J. Benton United Pump and Controls, Inc.
Release Detection for Piping Spring Types of Piping Safe Suction “Unsafe” Suction Pressurized.
Spill and Overfill Prevention Alaska Spring 2004.
Also known as the Storage Tank Act of Which of the following tanks is not a regulated tank? a. An farm underground storage tank (UST) that contains.
Idaho’s UST Program UST Program Summary  Fairly New Program  Energy Act of 2005  Statute Feb  Rules April 2008  State Program Approval.
Underground Storage Tank Compliance Act of 2005 Bill Torrey UST/LUST Regional Program Manager US EPA – New England EBCNE April 19, 2006.
Adem.alabama.gov ADEM Land Division Update Chip Crockett Chief, Industrial Hazardous Waste Branch Air & Waste Management Association Southern Section Pine.
WWQRR, Chapter 17, Section 44 Page  Have not performed tank leak detection in 60 days  Did not perform CP test within 90 days of due date 
Adem.alabama.gov Alabama Land Division Regulatory Update Wm. Gerald Hardy Chief, Land Division 2008 Southern Section A&WMA Annual Conference August 6,
March Why is MassDEP proposing new UST regulations? DFS’s regulation: standards for tanks construction, installation, O&M, decommissioning and.
MassDEP Underground Storage Tank Program Program Requirements for Owners and Operators Winter 2015 Workshops 1.
Section 4 Ancillary Equipment Section 4 Ancillary Equipment Definition Dispensers & Under Dispenser Containment Vapor Recovery Drop Tube & Fill Port.
PRODUCT LINE LEAK DETECTION (including a summary of the 2015 UST regulations) Katie Seaborn AMERICAN CONTAINMENT SERVICES, INC. ® Annual GTEC Underground.
Workshop on Permanent Closure of Single-Walled USTs and Funding Opportunities For Closure and Cleanup.
Staying in Compliance Inventory Control Bill Greer GTEC.
BY: Winston G. Smith Environmental Engineer UST/PCB & OPA Enforcement & Compliance Section EPA Region 4.
Joe Stapinski Senior UST Inspector (317)
Overview of 3 rd Party Inspection Program for USTs.
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by Travis Benton United Pump and Controls, Inc.
1 1 Staying in Compliance: Spill and Overfill Presented by: Brent Roth OPW Retail Fueling IPECA UST Seminar 2015.
| Excellence. Value. Get There!™ Aboveground Storage Tanks David L. Yaussy, Spilman Thomas & Battle, PLLC.
Presented at the Fifth Annual California Unified Program Conference February 6, 2003 Enhanced Vapor Recovery Cindy Castronovo Air Resources Board Cal-EPA.
Release Reporting. How Do I Know If I Have a Leak in My UST System? 1. Unusual operating conditions; such as, erratic behavior of the dispensing pump.
EXCALIBUR GROUP, LLC Evolving Regulations for USTs in New York For New York State August 1, 2013.
IPECA UST Seminar IDEM Leaking UST and Excess Liability Trust Fund Updates Craig Schroer, Chief UST Branch Indiana Department of Environmental Management.
1 Final Rulemaking - Chapter 245, Administration of the Storage Tank and Spill Prevention Program (Subchapters A-H) Environmental Quality Board Meeting.
Veeder-Root Company Presents: EPA Compliance Basics Presenters: Bill Tobias, Director of Sales, Veeder-Root Carlton Knowles, Territory Sales Manager, Veeder-Root.
Automatic Gauging Tank System: A Next Generation Tool for UST PROF. HÉCTOR CRUZADO ENGINEERING MANAGEMENT PROJECT MEM 6200-SP-15 JOSÉ J. ROSA ROSARIO STUDENT.
Briefing on Proposed Amendments to Rules for Underground Storage Tank Management, Chapter August 1, 2017.
Edward S. Kubinsky Jr. CROMPCO, LLC
UST Inspection Program
Release Reporting Lesson 17 covers the subject of Release Reporting. You will learn how you know when you have a leak and what leaks require reporting.
2007 EPA Region 4 – Department of Defense – States Environmental Conference June 21, 2007 Atlanta, Georgia.
Underground Storage Tanks New Federal 2015 Requirements
PRODUCT PIPE LEAK DETECTION
Petroleum Storage Tanks – Program Updates
Staying in Compliance: Spill and Overfill
July 13, 2016 Department of Environmental Quality Proposed Amendments to UST Rules 15A NCAC 02N and 02O Ruth Strauss.
New Install Proposed rule changes
September 8, 2016 Department of Environmental Quality Proposed Amendments to UST Rules 15A NCAC 02N and 02O Ruth Strauss.
GTEC 2017 Annual UST Management & Compliance Assistance Seminar
COMPLIANCE CHALLENGES FACING OWNERS OF UNDERGROUND STORAGE TANKS
Alabama Tools Seminars
Introduction to Overfill Prevention for USTs
Overfill Prevention Technology and Maintenance
Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective – 1/11/2017.
EPA Corrosion Study
NEW COMPLIANCE REGULATIONS
COMPLIANCE VIOLATIONS FOUND DURING INSPECTIONS
Air and Water Management Association Regulatory Conference Symposium
Cupa violation Review BAESG Meeting May 20, 2019 Matthew Burge
Petroleum Storage Tank Rule Updates Complying with the new PST rules and changes to the PST Compliance Notebook Trade Fair 2018 Rebekah Stanush Compliance.
Petroleum Storage Tanks – Program Updates
Compliance Assistance Specialist
Presentation transcript:

ACCA Legislative Conference Underground Storage Tank Compliance December 4, 2014 Lee Davis, UST Compliance adem.alabama.gov

UST Compliance Program Outline UST Program Overview Regulatory Requirements 2005 Energy Act adem.alabama.gov

Definition of UST Tanks and Piping Contains Regulated Substances 10% or More Underground adem.alabama.gov

USTs adem.alabama.gov

Regulated Universe Regulated Facilities ~ 5,600 Regulated Tanks ~ 15,300 Number of Tank Owners ~ 3,100 adem.alabama.gov

Inspectors 9 UST Inspectors in 4 Field Offices Approximately 400 inspections per inspector, per year adem.alabama.gov

Performance Standards USTs and Piping Fiberglass-Plastic Construction, or Steel and Protected from Corrosion Piping Nonmetallic, or adem.alabama.gov

UST adem.alabama.gov

Piping adem.alabama.gov

Performance Standards Spill Prevention To contain the volume of the delivery hose after disconnecting adem.alabama.gov

Spill Catchment Basin adem.alabama.gov

Performance Standards Overfill Prevention Activated by product level to prevent tank overfills adem.alabama.gov

Overfill Prevention Flapper Valve 4 1 2 3 2 3

Overfill Prevention Ball Float Valve 3 2 1

Regulatory Requirements Testing and Reporting Corrosion Protection Leak Detection Spill Catchment Basin Closure Suspected Releases adem.alabama.gov

Testing CP Test Cathodic protection test required once every three years adem.alabama.gov

Cathodic Protection System adem.alabama.gov

Impressed Current Anode adem.alabama.gov

Rectifier adem.alabama.gov

Galvanic Cathodic Protection System adem.alabama.gov

Release Detection Tanks – must have monthly method of monitoring for releases Pressurized Piping - must have annual line test or monthly monitoring Suction Piping – No monitoring required if “safe suction” adem.alabama.gov

Automatic Tank Gauge adem.alabama.gov

Testing Leak Detection Leak Detectors - equipment that will shut off or restrict flow of product if a leak is detected – Annual test Sump Sensors – Annual test adem.alabama.gov

Testing & Reporting SIR Annual Summary Report Line Tightness Tests Annual Line Leak Detector Tests Annual Cathodic Protection Tests 3 Year Spill Catchment Basins 3 Year adem.alabama.gov

Reporting Closure and Releases Permanent Closure of a UST System Suspected releases must be reported within 24 hours. Investigation and Corrective Action adem.alabama.gov

Suspected Release adem.alabama.gov

Secondary Containment Delivery Prohibition Operator Training 2005 Energy Act Secondary Containment Delivery Prohibition Operator Training adem.alabama.gov

Secondary Containment Effective August 6, 2007 Tank and Piping Manufactured with Inner and Outer Wall and Interstitial Space Interstitial Monitoring Only Acceptable Form of Leak Detection adem.alabama.gov

Submersible Pumps Effective August 6, 2007 USTs installed with submersible pumps on August 6, 2007 and thereafter, must have submersible pump containment sumps. adem.alabama.gov

Sub Pump Sump adem.alabama.gov

Under Dispenser Containment Effective August 6, 2007 New Dispenser System Includes Equipment Necessary to Connect to UST System adem.alabama.gov

Under Dispenser Containment adem.alabama.gov

Delivery Prohibition 2005 Energy Act Prohibition of delivery or acceptance of product for non-compliant UST facilities Penalty for owner and deliverer Regulations Effective April 25, 2008 adem.alabama.gov

Delivery Prohibition adem.alabama.gov

Delivery Prohibition Reasons Delivery prohibition may be imposed for failure of an owner to: Install, operate and/or maintain cathodic protection, leak detection, under dispenser containment, or spill or overfill controls Ensure compatibility of UST with product Perform required testing Pay regulatory fees Take corrective action for releases adem.alabama.gov

Delivery Prohibition ADEM Steps How will ADEM notify owners they are subject to delivery prohibition? Notice of Delinquency Notice of Violation Notice of Delivery Prohibition Opportunity to meet with Department adem.alabama.gov

Delivery Prohibition DP List How will ADEM notify fuel delivery companies that a facility is prohibited from delivery? Delivery Prohibition List on ADEM web site Delivery Prohibition List updated every Wednesday at 12:00 a.m. adem.alabama.gov

Delivery Prohibition Owner Response How can owners be removed from the Delivery Prohibition List? Return to Compliance Submittal of documentation ADEM will remove facility from list ADEM will send letter adem.alabama.gov

Operator Training adem.alabama.gov

Operator Training 2005 Energy Act Operators must be trained by August 8, 2012. Three classes of operator adem.alabama.gov

UST Trust Fund Registration Motor Fuel Substantial Compliance Orders Spill Prevention Overfill Prevention Corrosion Protection Release Detection adem.alabama.gov

AST Trust Fund Registration Motor Fuel SPCC Plan NPDES Permit adem.alabama.gov

UST Compliance Program I Can Answer Any Questions You May Have Now. adem.alabama.gov

Chief, UST Compliance Unit (334) 271-7759 mld@adem.state.al.us Contact Information – Lee Davis Lee Davis Chief, UST Compliance Unit (334) 271-7759 mld@adem.state.al.us UST Switchboard (334) 270-5655 ustcompliance@adem.state.al.us adem.alabama.gov