Simulation Proposed Device Modified Helium Dilution 1 Standard Helium Dilution Conclusion Above: Schematic Diagram of the proposed device. Right: Image.

Slides:



Advertisements
Similar presentations
Neonatal Mechanical Ventilation
Advertisements

Digitally-Bypassed Transducers: Interfacing Digital Mockups to Real-Time Medical Equipment Scott Sirowy*, Tony Givargis and Frank Vahid* This work was.
CPAP/PSV.
Extracorporeal CO2 Removal in ARDS
Safety Requirements of the Anesthesia Workstation
Mechanical Ventilaton Ramon Garza III, M.D.. Indications Airway instability Most surgical patients or trauma Primary Respirator Failure Mostly medical.
Resting Lung Volumes An Introduction to Spirometry.
P.L.V. Eugene Yevstratov MD 2008 PartialLiquidVentilation.
Dr Tristan GR Dyer RCSEd Fellow in Pre-hospital Emergency Medicine.
Initiation of Mechanical Ventilation
POSITION CHANGES : FREQUENCY AND DURATION Position change is one of the general kinds of nursing actions during care of patients. Position change is.
Wasted Ventilation. Dead Space dead space is the volume of air which is inhaled that does not take part in the gas exchange, either because it (1)
Objectives Discuss the principles of monitoring the respiratory system
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
Respiratory Physiology - introduction Daniel Hodyc Department of Physiology UK 2.LF.
Review Lung Volumes Tidal Volume (V t )  volume moved during either an inspiratory or expiratory phase of each breath (L)
Neonatal Chest Compression Device Courtney Gallagher Jillian Zeber Advisor: Dr. Walsh, Vanderbilt NICU.
Protective Lung Strategy Mazen Kherallah, MD, FCCP
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Thursday, April 20, 2017 Critical care units HIKMET QUBEILAT.
CPAP Remote Alarm System BME 272: Oral Report Two Group 15 Kathleen Grunder Jessica Paulsen Molly Rice.
SERVO-i WITH HELIOX OPTION
Ventilators All you need to know is….
Dr Chaitanya Vemuri Int.Med M.D Trainee.  The choice of ventilator settings – guided by clearly defined therapeutic end points.  In most of cases :
Efficacy of Non Invasive Biphasic Cuirass Ventilation (BCV) in Neonatal Piglets Comparison with Conventional Positive Pressure Ventilation F.G. Eyal, MD,
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
CPAP Murila fv. Respiratory distress syndrome 28% of neonatal deaths are due to prematurity The most common respiratory disorder in the preterm is Respiratory.
IV Tubing Organizer Blake Hondl, Amit Mehta, Ryan Pope, Kristen Sipsma, April Zehm, Katie Zenker BME 200/300 October 10, 2003.
Oxygenation And Ventilation
ANAESTHESIA BREATHING CIRCUITS
Abstract The metabolic rates of critically ill patients can vary drastically from typical metabolic rates. This can cause problems for health care providers.
Measuring Neonatal Lung Volume
Measuring end-expiratory lung volume Giacomo Bellani, M.D., Ph.D. University of Milano-Bicocca Monza, Italy
Printed by BabyView: Real Time Monitoring of Neonatal Intensive Care Patients Erin L Scott *, Dr. Bill Walsh +, Dr. Paul King * *Department.
Pandemic [H1N1] 2009 RT Education Module 2 Lung Protection.
Measuring Functional Residual Capacity of Ventilated Neonates
Evaluation of Ergonomics of Data Entry System in Neonatal Intensive Care Unit John Fonge 1, Kendra Mills 1, and Brandy Scott 1 Advisor: Dr. William Walsh,
Measuring Neonatal Lung Volume Advisor: Dr. Bill Walsh Doug Anderson David Lammlein Janine McKinnon.
Respiratory support and respiratory outcome in preterm infants PD Dr. med. Ulrich Thome Division of Neonatolgy and Pediatric Critical Care University Children’s.
The Role of Physiological Models in Critiquing Mechanical Ventilation Treatments By Fleur T. Tehrani, PhD, PE Professor of Electrical Engineering California.
Mechanical Ventilation Mary P. Martinasek BS, RRT Director of Clinical Education Hillsborough Community College.
Basic Concepts in Adult Mechanical Ventilation
THE EFFECT OF TIMING OF INITITIATION OF CRRT ON PATIENTS REQUIRING EXTRA-CORPOREAL MEMBRANE OXYGENATION (ECMO) Asif Mansuri, MD, MRCPI Fellow, Division.
The purpose of the breathing rhythm is to ventilate the lungs to allow delivery of oxygen to the alveoli, and elimination of the waste gas carbon dioxide.
UW MEDICINE │ Turkish Society of Perfusionists 3 rd Perfusion Symposium CARDIOPULMONARY BYPASS HOW DO WE KNOW WHAT WE ARE DOING? CRAIG VOCELKA, M.DIV.,
Ventilator Management James Eakins, MD FACS Director, Trauma and Surgical Critical Care Hahnemann University Hospital.
BabyView: Real Time Monitor of Infant Patients Erin Lynne Scott Dr. Bill Walsh.
Oxygen Control and Measure System Development Divia Patel, Angie Powe, Stacey Scheib Advisors: Dr. John Penn Dr. Paul King.
Chapter 6 The Respiratory System and Its Regulation.
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
Neonatal Chest Compression Device Courtney Gallagher Jillian Zeber Advisor: Dr. Walsh, Vanderbilt NICU.
Cable and Fluid Line Management System Justine W. Carter Advisor: Richard Fries, Datex-Ohmeda Dr. Paul King.
Visual Alarm System for Ohmeda Biox 3700 Pulse Oximeter Alex Choe Rohit Mittal Advisor: Dr. Walsh, Dr. Linstrom.
Intrapulmonary Percussive Ventilation Carl W. Israel*, Tim Weaver*, James Grotting*, Joshua Gess^, Ryan Winter^, Dr. Paul King * *Department of Biomedical.
PRESSURE CONTROL VENTILATION
Ventilator-Induced Lung Injury N Engl J Med 2013;369: Arthur S. Slutsky, M.D., and V. Marco Ranieri, M.D 호흡기 내과 / R4 이민혜 Review Article.
Multiscale Thermofluid Engineering Laboratory 1 Oxygen Transport in Blood Flows Past Staggered Fiber Arrays: A Computational Fluid Dynamics Study of an.
Mechanical Ventilation
MACS CPAP System Self Guided Tour.
High Frequency Oscillatory Ventilation
Mechanical Ventilator 2
Basic Concepts in Adult Mechanical Ventilation
Monitoring and Control of Blood Oxygen Saturation Levels
FLIGHT MEDICAL B-Lev Mode Biphasic Ventilation Confidential.
Nursery Chart System Development
Improving Simulations in the Post Anesthesia Care Unit
Measuring Neonatal Lung Volume
Auto Bag Jerome H. Santoyo Jessica S. Yeager Advisor: Richard Fries
Auto Bag Jerome H. Santoyo Jessica S. Yeager Advisor: Richard Fries
Presentation transcript:

Simulation Proposed Device Modified Helium Dilution 1 Standard Helium Dilution Conclusion Above: Schematic Diagram of the proposed device. Right: Image of constructed prototype device. From top down: anesthesia bag in closed container, Collins Helium sensor, Millipore peristaltic pump Our proposed device consists of 5 necessary components as well as an optional computer for data collection and analysis: Helium Sensor: The Collins Helium Sensor (Collins Medical, Braintree, MA) used in our prototype measures helium concentrations from 0-15% Pump: The Millipore peristaltic pump (Millipore, Billerica, MA) provides a variable flow rate to maintain gas flow across the helium analyzer as well as aid gas mixing within the sensing circuit Valve: A simple 3-way valve allows for selection of gas input to the neonate, either directly from the ventilator or from the sensing circuit. Anesthesia bag in airtight container: This component serves to maintain ventilator support for the neonate during measurement. The pressure exerted by the ventilator on the rubber anesthesia bag is transferred into the sensing circuit thus maintaining ventilator support. Ventilator: The sensing circuit is designed so that any ventilator or CPAP device can be used. At the Vanderbilt Children’s Hospital, the Evita 4 (Draeger Medical, Telford, PA) is the most commonly used. Testing of the prototype device did not yield reliable results. We believe this was due to inadequate gas mixing within the sensing circuit. Helium dilution is a commonly used method of measuring the functional residual capacity. The patient breathes from a known volume of gas with a known helium concentration. After the gas has had time to equilibrate with the patient’s lungs, the concentration is measured again. The FRC can be calculated using the equation below: Where C i and C f are the initial and final Helium concentrations, respectively, and V is the initial volume. While potentially any gas can be used, Helium has some distinct advantages: It is physiologically inert. It is not absorbed by the blood in any appreciable amount. It is relatively common and inexpensive. Standard helium dilution does have a drawback as well, it requires a closed system. Any leaks, like those from an uncuffed endotracheal tube, will make the measurement invalid. Anesthesia Bag Ventilator Pump He Sensor The standard helium dilution method can be modified to account for the effects of a leaky system. By assuming the leak can be expressed as an exponential function of time and measuring the helium concentration at 2 time points, we can estimate the equilibrium concentration if no leak was present using this equation: This estimate of the final concentration can then be used in the standard helium dilution equation to calculate the FRC. Previous researchers have used this method with excellent results: In Vitro Confirmed expected exponential relationship Real vs. Calculated: r = 0.995, p<0.001 In Vivo CPAP (cm H 2 O) 03 FRC (ml/kg) 22.0   1.4 N1530 The Problem Too small a FRC can result in the inability to oxygenate blood and possibly death if blood entering the lung actually exits the lung without coming into contact with an exchangeable gas surface—shunting Current trial and error methods used to adjust ventilator settings can cause too much PEEP or CPAP which in turn can cause barotraumas, preventing the blood from going into the lung If ventilation techniques fail due to lack of oxygenation a patient is placed on ECMO (Extracorporeal Membrane Oxygenation) which constitutes a high probability of mortality Background Functional Residual Capacity (FRC) Volume remaining in the lungs at resting expiratory level Equivalent to the alveolar volume (Va) which contains 60-70% of the total lung volume Normal FRC in adults is 1.8 to 3.4 L Estimated FRC in healthy neonates is ~25 mL The Division of Neonatology at Vanderbilt Children’s Hospital has an interest in determining the Functional Residual Capacity (FRC) in neonates who are mechanically ventilated. Methods to determine FRC must be simple, non-invasive, and allow free access to neonates. Additionally, the method must be employed in the Neonatal Intensive Care Unit (NICU) which includes 60 intensive and intermediate beds, a 3 bed ECMO unit, and 10 bed intensive care nursery. Determination of Ventilator Settings X-rays can be used to help determine PEEP and O2 saturation level Trial and error from years of experience is used to make adjustments to get sufficient oxygenation Market Potential Design Goals Avoid complicated, dangerous, or invasive procedures Uncooperative nature of an infant Compatibility with any standard ventilator Compact and mobile Allow continued free access to the neonate Compensate for leaks due to uncuffed endotracheal tubes No current patents on such a device Standard Ventilation Costs at Vanderbilt Medical Center = $2000/day ECMO Cost at Vanderbilt Medical Center = $5000/day Reduces hospital costs because knowing FRC could prevent resorting to ECMO Measurement of Functional Residual Capacity in Mechanically Ventilated Neonates Douglas Anderson 1, David Lammlein 2, and Janine McKinnon 1 Advisor: Dr. Bill Walsh, M.D. 3 1 Vanderbilt University Department of Biomedical Engineering 2 Vanderbilt University Department of Mechanical Engineering 3 Children’s Hospital at Vanderbilt University Division of Neonatology Social Impact This device has the potential to save many lives by eliminating the need for more dangerous or complicated procedures. The resulting impact on the friends and family of critically ill neonates will be profound. In addition, the procedure poses no environmental hazard as it uses helium, an inert gas, in its testing Our proposed device was simulated using a simple, two compartment model. For a circuit volume of 185 mL 1, a neonate with a FRC of 26.5 mL 1,2 and using normal parameters for ventilated neonates 2 both the concentration of helium in the measuring circuit and oxygen content of the lungs were simulated for 2 leak states. We calculated the FRC from the helium concentration data at 45 seconds in the no leak data at 45 and 60 seconds in the leak data: No Leak: 26.5 mL Leak: 25.6 mL Modified Helium Dilution can be used to measure the FRC of a ventilated neonate with reasonable accuracy, even in a leaky system For a neonate with normal ventilation parameters, the oxygen content of the lungs remains at safe levels over the measurement period To ensure adequate gas mixing, the total volume of the sensing circuit must remain as low as possible without compromising the neonates oxygen levels Acknowledgements We would like to sincerely thank Dr. Walsh and Dr. Paul King for their continued support and advice. We would like to thank Dr. Dan Lindstrom for aiding our equipment search. Finally, we would especially like to thank Chris Lynn, whose help on this project is immeasureable. 1 Schwartz, JG, Fox, WW, Shaffer, TH. “A Method for Measuring Functional Residual Capacity in Neonates with Endotracheal Tubes.” IEEE Trans. Biomed. Engr. May (3): Szymankiewicz, M, Vidyasagar, D, Gadzinowski, J. “Predictors of successful extubation of preterm low-birth-weight infants with respiratory distress syndrome.” Pediatr Crit Care Med (1): 44-49