HEAT EXCHANGERS in food process engineering Energy balance methodology used to design industrial equipments 1 FIP-DES Bertrand Broyart, Violaine Athès.

Slides:



Advertisements
Similar presentations
ENERGY CONVERSION MME 9617A Eric Savory
Advertisements

Quiz – An organic liquid enters a in. ID horizontal steel tube, 3.5 ft long, at a rate of 5000 lb/hr. You are given that the specific.
Unit Operations Semester Quality Technology – VBP045.
Basic Refrigeration Cycle
Application of Steady-State Heat Transfer
Heat Exchangers: Design Considerations
So Far: Conservation of Mass and Energy Pressure Drop in Pipes Flow Measurement Instruments Flow Control (Valves) Types of Pumps and Pump Sizing This Week:
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Chapter 2: Overall Heat Transfer Coefficient
Heat Exchangers: The Effectiveness – NTU Method
MER Design of Thermal Fluid Systems
Paul Ashall, 2008 Module 9002 Heat Transfer and Heat Exchangers.
Engineering and thermal processing. Engineers are different from scientists What do scientists do? What do engineers do? The importance of simplifying.
Typical Heat Exchange Equipment Energy balances Heat flux and heat transfer coefficients Temperature difference Overall heat transfer coefficient Heat.
HEAT EXCHANGERS Day 2.
Heat exchangers. Device that facilitate the exchange of heat between fluids that are at different temperatures while keeping them from mixing with each.
Heat exchangers The device at which heat exchange between two fluids at different temperatures and separated by a solid wall occurs is called heat exchanger.
Chapter 3.1: Heat Exchanger Analysis Using LMTD method
PM3125 Content of Lectures 1 to 6: Heat transfer: Source of heat
Introduction to Heat Exchangers
Deduction of Fundamental Laws for Heat Exchangers P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Modification of Basic Laws for.
Flow Inside Heat Exchangers
Heat Exchanger & Classification Prepared by: Nimesh Gajjar
© Food – a fact of life 2009 Heat exchange Foundation DRAFT ONLY.
HEAT EXCHANGER.
Fouling Factor: After a period of operation the heat transfer surfaces for a heat exchanger become coated with various deposits present in flow systems,
Outline (1) Heat Exchanger Types (2) Heat Exchanger Analysis Methods
A Presentation on HEAT EXCHANGER DESIGN
Heat Transfer Equations For “thin walled” tubes, A i = A o.
M4 -Group 9 Teoh Jie Shun Dominic Cheong Johnny Yeung.
Master Brewer Program (6 Weeks) 1. Fluids fundamentals and equipment. 2. Fluids test. Heat transfer fundamentals and equipment. 3. Heat transfer test.
Heat Exchangers Heat exchangers are used to transfer heat from one stream to another. They are used to heat streams and to cool streams. The streams can.
Lesson 13 CONVECTION HEAT TRANSFER Given the formula for heat transfer and the operating conditions of the system, CALCULATE the rate of heat transfer.
Heat Transfer/Heat Exchanger How is the heat transfer? Mechanism of Convection Applications. Mean fluid Velocity and Boundary and their effect on the.
Theory of Heat Exchanging P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Understanding of Qualities of An Ideal Heat Exchangers…..
Design and construction We need to seek a design that Achieve the goal of the project which should be : compact effective So we need to know types of heat.
Convection: Internal Flow ( )
Chapter 11 Heat Exchangers ( ) Heat Exchangers.
Heat Transfer/Heat Exchanger How is the heat transfer? Mechanism of Convection Applications. Mean fluid Velocity and Boundary and their effect on the rate.
Heat Transfer Equations. Fouling Layers of dirt, particles, biological growth, etc. effect resistance to heat transfer We cannot predict fouling factors.
Reading Materials: Chapter 9
Heat Transfer Equations For “thin walled” tubes, A i = A o.
FOOD ENGINEERING DESIGN AND ECONOMICS
PASTEURIZATION AND BLANCHING PURPOSE OF THE PROCESSES DESCRIPTION OF PROCESSING SYSTEMS ESTABLISHMENT OF THE PASTEURIZATION PROCESS DETERMINATION OF BLANCHING.
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 11 Heat Exchangers.
Exercises for Q1. Insulated copper tube A thin walled 10 mm copper tube is used to transport a low-temperature refrigerant with a temperature that is.
Professor: Eduardo Cabrera Thermal Engineering Laboratory
Heat Transfer by Convection
Winter/ IntroductionM. Shapiro 1 Can calculate Q 12 [J] from the first law of thermo. קצב מעבר חום heat transfer rate can’t calculate from thermo.
Professor Eduardo Cabrera
Concentric Tube (double-pipe) Heat Exchangers
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 11 Heat Exchangers.
Heat Transfer 传热学 Li xuemei Welcome to.
HEAT TRANSFER Introduction
Government Engineering College
Chapter 11: Heat Exchangers
A Device which Enhanced the Utility of Fire!!! A True Mediator !!!
Heat exchange.
WHAT IS HX……??? Heat exchangers are equipment that transfer
Heat Exchanger Analysis
Heat Transfer Ana Galvao, Julie Kessler, Luke O’Malley, Matteo Ricci & Jessica Young “L JJAM” aka “Dream Team” aka Team 3 CHBE446 02/02/18 Aka “Haha. A.
Chapter 11: Heat Exchangers
Concentric Tube (double-pipe) Heat Exchangers
Reading Materials: Chapter 9
Heat Exchangers Heat Exchangers.
Heat Exchangers Heat Exchangers.
Chapter 11 HEAT EXCHANGERS Mehmet Kanoglu University of Gaziantep Copyright © 2011 The McGraw-Hill Companies, Inc. Permission required for reproduction.
Heat Exchangers Heat Exchangers.
12. Heat Exchangers Chemical engineering 170.
FDE 101-Basic Concepts in Food Engineering
Presentation transcript:

HEAT EXCHANGERS in food process engineering Energy balance methodology used to design industrial equipments 1 FIP-DES Bertrand Broyart, Violaine Athès Cristian Trelea

Outlook Motivation: thermal treatment of liquid food (recall) Types of heat exchangers – illustrations Design of heat exchangers – Heat transfer – Heat balances Tutorials

3 Operation Objective Thermal treatment of liquid food (recall) Stabilisation Texturing - Concentration - Pasteurisation - Sterilisation - Chilling - Cooking - Crystallisation - Emulsification - Enzyme inactivation - Micro-organism destruction - Water activity reduction - Viscosity increase - Phase change (e.g. gel formation, freezing …)

Types of equipment for thermal treatment 1- Heat treatment AFTER conditioning   Autoclaves 2- Heat treatment BEFORE conditioning   Heat exchangers

5 Sterilisation cycle in an autoclave Retort temperature Product temperature Time (min) Heating Cooling

Main types of heat exchangers Sales : € 600 M per year in Europe for food industries price of a sterilisation line: several M€ 1- Heat exchangers with a wall: indirect transfer  tubular geometry : concentric tubes  plane geometry : plates, blades  extended geometry : fins on plates or tubes  Configuration : co-, counter-, cross- current  Compactness :  plates: de 150 à 300 m 2 /m 3 of installation  tubes : 30 m 2 /m 3 of installation 2- Heat exchangers without wall: direct transfer  vapour injection  direct electrical heating (ohmic)

7 Principle of tubular heat exchangers Single tube Several tubes

8 Principle of plate heat exchangers

9 Plate heat exchangers

10 Scraped surface heat exchanger Highly loaded media (e.g. custard, cream) Texturing (e.g. ice-cream) Low compactness (1 m 2 / m 3 ) Motor Product outlet Product inlet Product Insulation Thermal fluid Rotor Scraper Thermal fluid inlet Thermal fluid outlet Scrapers Rotor Heat transfer wall Insulation Thermal fluid

11 An industrial production chain Homogenisation Storage Conditioning Heat treatments Raw milk UHT milk

Design of heat exchangers: heat transfer Stationary heat transfer through a plane wall Fluid 1 e Fluid 2 T1T1 T2T2 T w1 T w2 Q Convection (fluid 1) : Q = h 1. A. (T 1 - T w1 ) Conduction (wall) : Q = ( w / e. A). (T w1 - T w2 ) Convection (fluid 2) Q = h 2. A. (T w2 - T 2 ) h G = 1 / (1/h 1 + e/ w + 1/h 2 ) h2h2 h1h1 w Q = h g. A. (T 1 - T 2 ) After eliminating wall temperatures, one can write the heat flux as a function of fluid temperature difference only: The global heat transfer coefficient corresponds to 3 thermal resistances in series (fluid 1 + wall + fluid 2):

13 Thermal conductivities: some orders of magnitude (W.m -1.K -1 ) Air = Water = 0.6 Stainless steel = 14 Glass = 0.8 Copper = < food products < 0.6 gas liquid solid << Oil Fat Milk Fruit juice Milk = 0.56

14 Convection coefficients: some orders of magnitude h (W.m -2.K -1 ) Air h = 5 … 50 Water h = 200 … 2000 Water State change L-V h = 2000 … h air h water h water L-V << Still Highly ventilated Stationary Flowing Boiling Vapour condensation PoorMediumGood

Consider à local heat flux dQ in a « slice of fluid » between A and A + d  : Design of heat exchangers: heat balance A O (inlet) A (outlet) h int h ext R int R ext1 R ext2 Cold fluid Hot fluid A (  T) A + d  T1T1 T2T2 (dQ) T h1 T c1.. T h2 T c2 ThTh T h – dT h T c + dT c TcTc 15

 Valid in co-and counter-current  16 Design of heat exchangers: heat balance (ctd) Local heat flux through dA Local heat balance for hot and cold fluids Global heat balance for hot and cold fluids Final result with Logarithmic mean temperature difference (Δ = hot – cold)

0L  T 1  T 2 Cold Hot  T 1  T 2 0L Cold Hot Co- and counter-current configurations of heat exchangers Inlet cold Inlet hot Outlet hot Co-current Outlet cold Counter-current Inlet cold Inlet hot Outlet hot Outlet cold 17 Liquid – liquid

 T 1  T 2 0L Condensing hot fluid Cold Condensation 0L  T 1  T 2 Cold fluid boiling Hot Boiling Co- and counter-current configurations of heat exchangers Special cases Inlet cold Inlet hot Outlet hot Co-current Outlet cold Counter-current Inlet cold Inlet hot Outlet hot Outlet cold 18  T  T 0L Cold Hot (formula for logarithmic mean temperature breaks down) With state change Same fluid on both sides

Tutorials Design a heat exchanger – calculate heat transfer coefficients – calculate the necessary area Compare co- and counter-current configurations Compare water and steam heating Consider the effect of fouling