GROUND-MED PROJECT COIMBRA DEMO-SITE André Quintino Duarte Coimbra, 23 February 2012.

Slides:



Advertisements
Similar presentations
Presentation Heading Air Source Heat Pumps Jordan Jeewood
Advertisements

Conduction Conceptests
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Fan Coil Unit Product Line-up. FCU Home Application Show.
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
TYPES OF MECHANICAL SYSTEMS
Stem Challenge Energy management systems, CHP, Harvester tank, green roofs and underfloor heating. 1.
UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product.
Components of HVAC System
UNEP - ECA network and thematic meetings in Ohrid – RAC meeting Ohrid, 21 May 2013 Slobodan Pejković Monitoring the performance in real-life of ground.
Mini Jet Sample Dyeing M/C Daelim Starlet Co., Ltd.
Presentation of product. Production capacity New heater For 15 years VTS Clima Group has been a leader in industrial heating engineering. Volcano VR.
Hydraulics.
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
The students: Mohammad Shabaro ( ) Mahmoud Mousa ( ) Yosri Asfour ( ) Supervisor: Dr. Iyad Assaf 1.
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
SOLAR HOT WATER Erica Mevs DFN Origin The shallow water of a lake is usually warmer than the deep water. The sunlight can heat the lake’s bottom.
Renewable Technologies Available in Ireland Paul Kane.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Muhajir Ab. Rahim School of Mechatronic Engineering
‘YGFC’ FAN COIL UNITS NEW PRODUCTS
Water piping design.
 a machine that moves heat from a location to another location, using mechanical work.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Perfect solution for large building
Cristopia (CIAT) - energy savings systems in air conditioning
Introduction Topic: The Basic Ground Source Heat Pump Name: Matthew Stoangi Objective: To provide a clear understanding of the mechanics involved in the.
ME 414 : Project 1 Heating System for NASA North Pole Project Team Members Alan Benedict Jeffrey Jones Laura O’Hair Aaron Randall May 5, 2006.
HEAT EXCHANGERS.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Lead Technology Task 6.2 Materials for mechanical pump for HLM reactors M. Tarantino, I. Di Piazza, P. Gaggini Work Package Meeting Karlsruhe, November.
Re-Commissioning of the Water Cooling System at Université de Sherbrooke Department of Buildings June 2008.
Thermal Storage Coupled to a Ground Source Heat Pump in a Public Services Building COIMBRA Andre Quintino Duarte Oradea, 06 June 2012.
Section 3 Using Heat.
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Facilities Management and Design Chapter 7 HVAC Systems.
Thermal Control System. The Three Mechanisms of Heat Transfer Conduction - The transfer of heat through a solid –Interface Heat Exchangers –Cold plates.
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
Lecture Objectives: Answer question related to Project 1 Finish with thermal storage systems Learn about plumbing systems.
Lecture Objectives: Analyze several modeling problems –Examples from the final project list Economizer Solar collectors Phase change thermal storage materials.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
2016 Chiller New Products Presentation.
Ulster.ac.uk Heat Pumps and Thermal Storage – Household Implementation to Grid Challenge Professor Neil J Hewitt Director, Centre for Sustainable Technologies.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Update on the PSB Cooling and Ventilation Systems
Lecture Objectives: Learn about thermal storage systems
Fan Coil Controller FC/S 1.1
Beam Dump Hall Volume Beam Dump Meeting at SLAC May S.Ban
UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Types of HVAC Technology Used in Business Establishments
‘SAPHIR’ FAN COIL UNITS…..
VED and VEDI VED and VEDI.
FCI and FCX Range FCI and FCX Range.
Hot Water Systems Cylinders and Systems.
______________ Combustion Engine
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
B. Munkhbayar BEEC/SCEA/MUST
Maintenance at ALBA facility: Strategy for the conventional services
FBE03: Building Construction & Science
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

GROUND-MED PROJECT COIMBRA DEMO-SITE André Quintino Duarte Coimbra, 23 February 2012

Demonstration Building Total area: 3250m 2 Four floors Two public services installed Offices, laboratories, conference room Capacity for 250 permanent workers + 72 temporary people in a conference room Located close to a river “Fábrica dos Mirandas”

Demonstration Building

The heated /cooled spaces are located in level 3 of the building (last floor). 22 rooms (offices) Approximately space conditioned area 600 m 2

Demonstration Building

Simplified schematics of the hydraulic installation 75 mm Diameter PPR Pipes in the main sections

Borehole Heat Exchanger DOUBLE U TUBE Borehole diameter (d)160mm Pipe internal diameter (D2)32mm Pipe external diameter (D1)35mm Shank spacing (s)56mm Seven vertical boreholes 125 m deep 5x5 m rectangular grid grout material is graded sand (pea size mm )

Geological Profile Alluvium Limestone / Sand / Silt Clay Loam Earthworks High Groundwater flow Freatic Groundwater level – 5 metres

Location of the Boreholes

Heat Pump Reversibility is done on the water side in order to always be in counter current on the heat exchangers. This is achieved by 3-way motorized valves

Piping System

Heat Pump Test Results Conditions Cooling mode EvaporatorCondenser Cooling capacity EER Eurovent Class A InletOutletInletOutlet EUROVENT12°C7°C30°C35°C56 kW5.05>= 5.05 Coimbra demo site 15°C10°C25°C30°C63.5 kW6.19n.a. Conditions Heating mode EvaporatorCondenser Heating capacity COP Eurovent Class A InletOutletInletOutlet EUROVENT10°C*40°C45°C61 kW4.58>= 4.45 Coimbra demo site 15°C**35°C40°C70.4 kW5.65n.a. The performance of the heat pump prototype was tested at the CIAT Culoz research center. Heating Capacity – 70.4 kW Cooling Capacity – 63.5 kW

Circulation Pumps High efficiency permanent magnet motor pump supplied by Grundfos, with variable speed control.

FanCoil Units The Fan Coil units were supplied by CIAT. They are COADIS 2 fancoil units models 235/22 and 235/33. A total of 33 units were installed – 23 units of model 235/22 and 10 units of model 235/33. These fancoil units are equipped with high efficiency impellers and high efficiency permanent magnet motors.

FanCoil Units

Each fan coil can be individually regulated by means of a thermostat. Comfort temperature can be selected by the user by means of a wall mounted control and fan speed is controlled automatically by means of a 0-10V control signal. The fancoils had to be retrofited with an electronic fan speed limiter, because of the noise generated was unacceptable by the users.

Location of the fancoil units

Thermal Storage The thermal storage tank is to be located in a room adjacent to the machinery room. It is planned to have a volume of 3.5m 3 (40% water + 60% PCM). Research is being conducted with the support of the Fluids Thermal Transfer Group of the Department of Mechanical Engineering on the best design of the tank to ensure optimal heat transfer and to ensure that the storage maximum capacity of the PCM modules is used. It was found that the most suitable material would be the S46 salt hydrate from PCM products Ltd (UK)

Preliminary test results

COP = 6,03

Thank you