STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.

Slides:



Advertisements
Similar presentations
ATLAS SCT Endcap Detector Modules Lutz Feld University of Freiburg for the ATLAS SCT Collaboration Vertex m.
Advertisements

AUTOMATIC TESTING OF MEDIPIX WAFERS Developing systems to measure Medipix chips Richard Plackett - CERN – April 2nd.
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
Ryan Badman, M. Artuso, J. Wang, Z. Xing July 7 th, 2010 TIMEPIX Characterization with test pulses with the Syracuse test stand.
Timepix Studies: Medipix Collaboration Summary and More Timewalk Plots Alessandra Borgia Marina Artuso Syracuse University Group Meeting – Thursday 20.
MDT-ASD PRR C. Posch30-Aug-02 1 Specifications, Design and Performance   Specifications Functional Analog   Architecture Analog channel Programmable.
Status of Oxford Setup Matthew Chalk, Erik Devetak, Johan Fopma, Brian Hawes, Ben Jeffery, Nikhil Kundu, Andrei Nomerotski University of Oxford ( 18 August.
Timepix2 power pulsing and future developments X. Llopart 17 th March 2011.
Power pulsing strategy with Timepix2 X. Llopart 10 th May 2011 Linear Collider Power Distribution and Pulsing workshop Timepix3.
MEDIPIX3 TESTING STATUS R. Ballabriga and X. Llopart.
1 WG5: MPGD related Electronics Tue. Oct. 14 th 9:00 to 12:00 W. Riegler, M. Campbell, CERN 2 nd RD51 Collaboration Meeting Paris, Mon. Oct 13 th to Wed.
A multi-chip board for X-ray imaging in build-up technology Alessandro Fornaini, NIKHEF, Amsterdam 4 th International Workshop on Radiation Imaging Detectors.
Oct, 2000CMS Tracker Electronics1 APV25s1 STATUS Testing started beginning September 1 wafer cut, others left for probing 10 chips mounted on test boards.
Si Pixel Tracking Detectors Introduction Sensor Readout Chip Mechanical Issues Performance -Diamond.
Status of the PiN diodes irradiation tests B. Abi( OSU), R. Boyd (OU), P. Skubic (OU), F. Rizatdinova (OSU), K.K. Gan (Ohio State U.)
Pierpaolo Valerio.  CLICpix is a hybrid pixel detector to be used as the CLIC vertex detector  Main features: ◦ small pixel pitch (25 μm), ◦ Simultaneous.
2. Super KEKB Meeting, DEPFET Electronics DEPFET Readout and Control Electronics Ivan Peric, Peter Fischer, Christian Kreidl Heidelberg University.
Erik HEIJNE CERN PH DepartmentRADWORKSHOP 29 November 2005 MEDIPIX2 for VERY LOW DOSE INITIAL LHC BENCHMARKING MEDIPIX2 for VERY LOW DOSE INITIAL LHC BENCHMARKING.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
The AGIPD Detector for the European XFEL Julian Becker (DESY), Roberto Dinapoli (PSI), Peter Goettlicher (DESY), Heinz Graafsma (DESY), Dominic Greiffenberg.
Specifications & motivation 2  Lowering integration time would significantly reduce background  Lowering power would significantly reduce material budget.
Robert Szczygieł IFJ PANSPIE 2005 Radiation hardness of the mixed-mode ASIC’s dedicated for the future high energy physics experiments Introduction Radiation.
Update on CLICpix design
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
DESIGN CONSIDERATIONS FOR CLICPIX2 AND STATUS REPORT ON THE TSV PROJECT Pierpaolo Valerio 1.
The DRS2 Chip: A 4.5 GHz Waveform Digitizing Chip for the MEG Experiment Stefan Ritt Paul Scherrer Institute, Switzerland.
The detection of single electrons using the MediPix2/Micromegas assembly as direct pixel segmented anode NIKHEF: A. Fornaini, H. van der Graaf, P. Kluit,
Pixel Readout Electronics - from HEP to imaging to HEP… Status, requirements, new ideas M. Campbell, R. Ballabriga, E. Heijne, X. Llopart, L. Tlustos,
Power Pulsing in Timepix3 X. Llopart CLIC Workshop, January
The BTeV Pixel Detector David Christian Fermilab June 17, 2010.
AMS HVCMOS status Raimon Casanova Mohr 14/05/2015.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
65 nm CMOS analog front-end for pixel detectors at the HL-LHC
Bi-CMOS Prakash B.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Sensor testing and validation plans for Phase-1 and Ultimate IPHC_HFT 06/15/ LG1.
Summary of FPIX tests Tom Zimmerman Fermilab May 16, 2007.
Pixel detector development: sensor
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
SuperKEKB 3nd open meeting July 7-9, 2009 Hans-Günther Moser MPI für Physik Sensor and ASIC R&D Sensor Prototype Production: running, ASICs: Switcher,
NI Big Physics Summit CERN
Timepix test-beam results and Sensor Production Status Mathieu Benoit, PH-LCD.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
R. Kluit Nikhef Amsterdam R. Kluit Nikhef Amsterdam Gossopo3 3 rd Prototype of a front-end chip for 3D MPGD 1/27/20091GOSSIPPO3 prototype.
TIMEPIX2 FE STUDIES X. Llopart. Summary of work done During summer I have been looking at a possible front end for Timepix2 The baseline schematic is.
1 FANGS for BEAST J. Dingfelder, A. Eyring, Laura Mari, C. Marinas, D. Pohl University of Bonn
Edgeless semiconductor sensors for large-area pixel detectors Marten Bosma Annual meeting Nikhef December 12, 2011, Amsterdam.
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
Technical status of the Gossipo-3 : starting point for the design of the Timepix-2 March 10, Vladimir Gromov NIKHEF, Amsterdam, the Netherlands.
NOISE MEASUREMENTS ON CLICPIX AND FUTURE DEVELOPMENTS Pierpaolo Valerio.
NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN.
Ideas on MAPS design for ATLAS ITk. HV-MAPS challenges Fast signal Good signal over noise ratio (S/N). Radiation tolerance (various fluences) Resolution.
Pixel structure in Timepix2 : practical limitations June 15, Vladimir Gromov NIKHEF, Amsterdam, the Netherlands.
e- and h+ (with leakage current compensation up to ~2nA/pixel)
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
ASICs1 Drain Current Digitizer Chip (DCD) Status and Future Plans.
Progress with GaAs Pixel Detectors
Charge sensitive amplifier
LHC1 & COOP September 1995 Report
Jan Soldat, Heidelberg University for the DSSC ASIC design groups
The AGIPD Detector for the European XFEL
STATUS OF SKIROC and ECAL FE PCB
BESIII EMC electronics
Silicon pixel detectors and electronics for hybrid photon detectors
Readout Electronics for Pixel Sensors
A new family of pixel detectors for high frame rate X-ray applications Roberto Dinapoli†, Anna Bergamaschi, Beat Henrich, Roland Horisberger, Ian Johnson,
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
Presentation transcript:

STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart

-2-X.Llopart Medipix 3 - reminder Medipix3 builds on the success of Medipix2 as a single photon counting imaging chip Added Features –Analogue charge summing to keep all charge information –Spectroscopic mode with 8 threshold levels –Continuous readout mode (no dead time) –Increased counter depth increasing dynamic range –Increased readout speed –Increased radiation hardness from 130nm CMOS process

-3-X.Llopart Status First engineering run (12 wafers of 100 chips) delivered early this year Wafer probing complete One wafer diced and bonded to PCBs Using the IC Tester data transfers speeds of 1.6 Gb/s were achieved Initial readout system working at low speed (USB from Prague) Electrical characterisation is almost completed Medipix3 readout integration in Pixelman is underway First bump bonded assemblies with wafers expected soon (~1 month) 17.3 mm 14.1 mm

-4-X.Llopart Electrical Characterisation Status Almost everything works as designed: –Complex pixel functionality: Charge summing, 8 independent thresholds, programmable counter depth –Expected ENC and minimum threshold has been measured as expected in all the different pixel modes Need to confirm the electrical characterisation with Medipix3 Si assemblies We found 2 issues with the chip –Cas and FBK DACs are not able to supply the designed nominal voltage –Continuous Read Write is not working correctly

-5-X.Llopart The “analog switches” (problem) Due to radiation and temperature an increase in the leakage current of NMOS transistors is observed

-6-X.Llopart Temperature Measurements Setup The Medipix3 has an on-chip temperature sensor in the chip periphery At CERN we have available the Climatic Chamber ESPEC EGNX12-6CWL (-70 °C to +180 °C) Measurements covered the -60 °C to 60 °C range

-7-X.Llopart Vcas and Vfbk temperature sensitivity Vcas is pulled low since the current leakage path goes to GND Vfbk is pulled high The consequence of this is effect is that the operational biasing of the front end is not stable in temperature and it must be controlled carefully

-8-X.Llopart Temperature effects in one pixel The chip is operational in all the studied temperature range But, we observe variations on the noise, threshold position and gain

-9-X.Llopart Pixel to pixel gain variation Gain variation (0.086 e - /THL DAC step) is due to the Medipix3 shaper stage

-10-X.Llopart Overall pixel noise variation Noise is increasing at low temperature probably due the change in front end bias voltages Vcas and Vfbk

-11-X.Llopart Overall threshold position shift Significant effect visible in the threshold position due to the variation on Vcas When the shaper’s pol-zero cancellation circuit is activated the measured temperature sensitivity is 16.7 e - /°C and 3.7 e - /°C when it is switched off.

-12-X.Llopart 400Mrad Irradiation Used a calibrated X-ray machine (Seifert RP149) Beam profile is smaller than the Medipix3 → Two runs: On the Pixel Matrix 60Mrad Threshold Variation Gain Variation Noise Increase On the Periphery 400Mrad Check DACs E-fuses Logic functionality 60 MRad 460 MRad 400 MRad

-13-X.Llopart Performance after 460MRad ThresholdNoise Yield artifact σ=1.72 ke - µ=9.3 ke - σ=12.9 e - µ=71.6 e - Threshold can be re-tuned using 5 bit equalisation

-14-X.Llopart Performance after 460MRad Yield artifact Qin=2ke - Row[0:255] After 460MRad there is essentially no gain variation observed

-15-X.Llopart DAC Measurement Band Gap Accumulated dose of 396 Mrad 9mV NMOS DAC (Preamp) Accumulated dose of 396 Mrad 33mV PMOS DAC For this technology there worst threshold shifts due to radiations happen ~3Mrad

-16-X.Llopart 3MRad irradiation 3 MRad Worst effect at 3MRad, After this the effect of further radiation is much less. Irradiated a small area of the chip up to 3Mrad to try and keep Cas DAC working by only damaging a limited number of pixels

-17-X.Llopart General behavior after 3 Mrad ThresholdNoise Yield artifact

-18-X.Llopart Overall threshold position variation Main contributor is the protection diode. In order to minimize the pixel to pixel threshold variation Ikrum is set to 16nA which indicated that the leakage of this diode at 3Mrad is ~5 to 10 nA. This is the worst radiation operation point. Row[0:255]

-19-X.Llopart 3MRad Noise and Gain Result Yield artifact Qin=2ke - Row[0:255] In this worst case situation the noise is still less than 100e - and the gain variation is still minimal

-20-X.Llopart Wafer Probing Summary Name#AABsCsDsEF# ChipsWhere VK7DG2H0 100 CERN/diced VT7DCWH CERN VT7DEVH Bump bonding VV7DFAH CERN VN7DE0H Bump bonding VU7DCVH CERN VW7DF9H CERN VQ7DCZH Bump bonding VS7DCXH CERN VU7DDCH CERN VL7DFJH CERN VW7DDAH CERN %15.1%3.9%31.5%7.4%2.5%100.0%

-21-X.Llopart Best and worst wafer

-22-X.LlopartConclusions The electrical characterisation of the chip is basically completed By monitoring the chip temperature and the radiation effects through Vcas line the chip is practically insensitive to radiation large temperature fluctuations Only remaining issue is to understand the failure mechanism of the CRW mode Yield results are very encouraging given the complexity of such chip First Si assemblies will be available shortly and will be use to confirm electrical measurements

-23-X.Llopart Towards Timepix2 In the Medipix3 collaboration there is a growing interest in Timepix2 It might be possible to fund this development with the Medipix3 funds Main specs: –Pixel to measure TOT and Arrival time information simultaneously –<2ns time resolution –Triggered readout –Sparse and very fast readout Many building blocks used in Medipix3 can be reused for a new chip Start of design depends on available experienced man-power