Action-Oriented Benchmarking Paul A. Mathew, Ph.D. Lawrence Berkeley National Laboratory Berkeley California Using CEUS Data to Identify and Prioritize.

Slides:



Advertisements
Similar presentations
NET ZERO STUDY ON A COMMUNITY COLLEGE By: Amanda OConnell Doenges.
Advertisements

eQuest Quick Energy Simulation Tool
DOE-2 Overview and Basic Concepts. Background  US public domain programs from 1970s Post Office program; NECAP (NASA energy- cost analysis program);
Energy Sub-Metering for Measurement and Verification
PERFORMING EFFECTIVE BUILDING SYSTEM RECOMMISSIONING STUDIES Joseph J. Watson, P.E. Booth # 312.
ASSESS TARGET DELIVER MEASURE Understanding Building Energy Audits Joe Hofstetter P.E., CEM, LEED AP Karpinski Engineering.
California Energy Commission Customer-side Distributed Generation Impacts CED 2013 Preliminary Demand Analysis Working Group DG PUP June.
HVAC Test and Balance And The Lodging Industry. Source: Florida Power.
University of Liège Faculty of Applied Sciences Thermodynamics Laboratory Workshop “Commissioning and Auditing of Buildings and HVAC Systems” Use of a.
T OPPORTUNITIES FOR ENERGY EFFICIENCY AT TRIBAL GAMING FACILITIES.
Peeking Under the Hood: The Energy Characteristics of California’s Commercial Building Sector Martha Brook, P.E. California Energy Commission.
Cleanrooms and Laboratories for High-Technology Industries Dale Sartor, P.E. Bill Tschudi, P.E. July 1999 Lawrence Berkeley National Laboratory Environmental.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
Plans for Commercial Building Benchmarking R&D in 2006 Martha Brook California Energy Commission PIER Buildings Program presented to the EPAC on December.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Building Technologies Program. FLEXLAB Background LBNL responded to a 2009 RFP for ARRA funds to develop a facility that: o Develops new test methods.
ENERGY EFFICIENCY FOR END-USERS.  CSU Chancellors office coordinates the efforts to accomplish the goals established by Assembly Bill 32 for green house.
1 Page 1 Public Interest Energy Research (PIER) California Institute for Energy & Environment (CIEE) Lawrence Berkeley National Laboratory Bill Tschudi.
RETScreen® Energy Efficiency Projects
Energy Conserving Alternatives HVAC 15a CNST 305 Environmental Systems 1 Dr. Berryman.
Morofsky1 Low-energy Building Design, Economics and the Role of Energy Storage Canadian possibilities based on the Model National Energy Code for Buildings.
Welcome! Bienvenue Υποδοχή Failte 歡迎 Bienvenidos 환영.
Benchmarking State Buildings Karen Herter, Heschong-Mahone Group (HMG) Mike Langley, Dept. of General Services (DGS) April 8, 2008.
SDB Retreat Panel Session: Scalability Across the Building Stock Randy Katz, Moderator Arka Bhattacharya Kaifei Chen Stephen Dawson-Haggerty 1.
This document was specifically prepared to aid utility account managers who are working with C&I customers. Any other use of this material (in whole or.
Benchmarking Energy Use in Commercial Buildings Satish Kumar, Ph.D. Lawrence Berkeley National Laboratory Public Sector Energy Management Workshop Mumbai,
Portfolio Manager ® Learning Objectives In this session, you will become familiar with EPA’s ENERGY STAR Portfolio Manager tool and learn how to:
DNV GL © 2014 SAFER, SMARTER, GREENER DNV GL © 2014 HVAC_3 Quality Maintenance 1 Research Plan.
© 2001 The Gas Company. All copyright and trademark rights reserved. High Efficiency Unit Heaters Workpaper Presentation Prepared for Cal TF Presentation.
Commercial Kitchens Dalhousie University Case Study With the financial support:
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
Managing Operational Energy in Buildings
Lawrence Livermore National Laboratory Building 111 Mike Holda Lawrence Berkeley National Laboratory (510) or (209) ,
College of Management & Economics, Tianjin University Projections of energy services demand for residential buildings: Insights from a bottom-up methodology.
1 Ir Michael P K Cheung Energy Efficiency Office Electrical and Mechanical Services Department The Government of the HKSAR The Role of Monitoring Energy.
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2C: School.
The Challenges & Opportunities created by California’s new Benchmarking Legislation Martha Brook California Energy Commission 2008 ASHRAE Annual Meeting,
Phoenix Convention Center Phoenix, Arizona Introducing the Building Energy Asset Score Building Performance Session 2: Elements of Building and Data Management.
Results from the California Energy Efficiency Potential Study – Existing Residential and Commercial Jean Shelton July 27, 2006 San Francisco, California.
Rating Laboratories Results from the Labs21 Program Paul Mathew, Dale Sartor Lawrence Berkeley National Laboratory Otto van Geet National Renewable Energy.
Northwest Power Planning Council The Fifth Plan’s Draft Conservation Resource Assessment Summary of Results To Date April 8, 2003.
Phoenix Convention Center Phoenix, Arizona Facility Energy Audits Mike Gutowski Johnson Controls August 12, 2015 Agency Energy ManagerEnergy Audits: Implementing.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Experience you can trust. Phase 1: Cataloguing Available End-Use and Efficiency Load Data September 15, 2009 End-Use Load Data Update Project.
California Energy Commission Plug Loads in the Residential and Commercial Forecasts June 18, 2015 Tom Gorin Energy Assessments Division
1 Lamp operating factor Published lumen output is based on laboratory conditions Voltage  Rated at line voltage of 115V Standard reactor ballast  Electromagnetic.
PAGE 1 Sustainable Buildings 2030 © 2008 THE WEIDT GROUP Building Energy Benchmarks THE WEIDT GROUP.
The lawrence berkeley national laboratory: a case study Revised 12/2/04.
Energy and Air Quality Conference April 5, 2004 Innovative financing, support, and solutions for Implementing Energy Projects.
1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory
New Construction Studies Performed by: MAESTRO/CALMAC Evaluation Showcase ● Pacific Energy Center ● July 26-27, 2006 EM&V of the Statewide Savings By Design.
The Data Center Challenge
CRAC March 4, Windows Update Regional Technical Forum March 4, 2003.
Sustainable Laboratory Design: Challenges and Solutions
Energy Efficient Data Centers Update on LBNL data center energy efficiency projects June 23, 2005 Bill Tschudi Lawrence Berkeley National Laboratory
Week 6 The Energy Walk Through. Possible elements of a walk through Understand on-site information collection and listing of essential data for collection.
Week 7 Utility Data Analysis. Essential Elements Identify sources for obtaining utility data: paper form, electronically or from the internet Review utility.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
Portfolio Manager ® Learning Objectives In this session, you will become familiar with EPA’s ENERGY STAR Portfolio Manager tool and learn how to:
Energy Solutions for Business Owners Presented by: [Put your name here] Welcome to... Your Logo Here.
RBSA Residential Building Stock Assessment Analysis of public power sample in BPA territory using single-family and manufactured homes databases July.
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Fort Stanwix National Monument Energy Audit Contract
HVAC-4 Deemed Measures Uncertainty Study, Year 2
Analysis of 2008 Title 24 Nonresidential Compliance Site Audits
The Data Center Challenge
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Visualizing IOT Data for Smarter Decision Support Systems
Case Study: Marks & Spencer Oxford Street
2018 Retro-Commissioning (RCx) Program
Presentation transcript:

Action-Oriented Benchmarking Paul A. Mathew, Ph.D. Lawrence Berkeley National Laboratory Berkeley California Using CEUS Data to Identify and Prioritize Efficiency Opportunities in California Commercial Buildings

Content  Introduction to action-oriented benchmarking  Using the CEUS database for AOB  AOB Vignettes – schools and offices  Limits of AOB  Outlook

Many Applications for Energy Benchmarking Granularity Rigor low CampusBuildingSystemComponent Set building/portfolio targets CCx, RCx Identify efficiency opportunities Recognition programs Identify “outliers” Property Valuation Set system targets high

Action Oriented Benchmarking Site BTU/sf-yr Ventilation kWh/sf-yr Peak cfm/sf Peak W/cfm Fume hood density Avg/Peak cfm ratio Fan efficiency Pressure drop Cooling BTU/sf-yr Potential to improve fan efficiency Potential to reduce energy use through ventilation system efficiency improvements Potential to reduce energy use through operational practices e.g. by optimizing ventilation rates Potential for energy efficiency in ventilation system Overall potential for building-wide energy efficiency Potential to reduce system pressure drop Impact of fume hoods on ventilation energy use Effectiveness of VAV fume hood sash management

Action-oriented Benchmarking Complements Other Assessment Tools Whole Building Energy Benchmarking Action-oriented Energy Benchmarking Investment-Grade Energy Audit Screen facilities for overall potential day FTE Minimal data requirements (utility bills, building features) Identifies and prioritizes specific opportunities 2-10 day FTE Requires sub-metered end- use data ; may require additional data logging Highly applicable for RCx and CCx Estimates savings and cost for specific opportunities day FTE Requires detailed data collection, cost estimation, financial analysis Necessary for retrofits with capital investments

CEUS Database  Commercial End Use Survey –Territories: PG&E, SCE, SDG&E, SMUD  Survey of 2800 premises –Stratified random sampling based on utility region, climate zone, building type, size (consumption) –On-site survey of building characteristics, features –Monthly utility bill data –Short term data logging and/or interval metering at some sites

CEUS Calibrated Simulations  Energy intensities derived from calibrated simulations –Simulation models generated from survey data –Calibrated with utility data, data logging, interval metering

CEUS End Uses  HVAC –Space Heating –Space Cooling –Ventilation  Lighting –Interior Lighting –Exterior Lighting  Other –Water Heating –Office Equipment –Cooking –Miscellaneous Equipment –Refrigeration –Air Compressors –Motors (non-HVAC) –Process Equipment

Using CEUS to Infer Actions End-Use Benchmarking –End-Use Intensity –End-Use Breakout Building Features –Presence/absence –Component efficiency Correlate Energy Intensities & Building Features Identify and Prioritize Systems Identify Potential Actions Estimate Potential Savings

Whole Building Energy Intensity  Overall Efficiency Potential

Whole Building Energy Intensity  Overall Efficiency Potential by Vintage

Whole Building Energy Intensity  Overall Efficiency Potential by Climate

End-Use Energy Intensity  System Efficiency Potential

End-Use Breakout  System Efficiency Potential and Prioritization

Building Features Benchmarking  Identify Potential Actions by Presence/Absence

Building Features Benchmarking  Identify Potential Actions by System Efficiency

Correlating Building Features and Energy Intensity  Estimate Potential Savings (sort of)

Limits of AOB  NOT “audit in a box” –Only identifies potential actions from predefined list –Only crude savings estimates (range)  Effectiveness is driven by database density –Many gaps in CEUS survey data  Ability to identify actions proportional to user ability to input data AOB helps identify potential actions and prioritize areas for more detailed analysis and audits

Outlook  Continued analysis of CEUS –Opportunities and limits for AOB  Development of action inference methodology –Mapping list of actions to benchmarking metrics  Prototype tool currently under development –Extensive user surveys to determine features –Expected April 2008

V Building type  All  Small Office Large Office  Restaurant  Retail  Food Store  Warehouse  School  College  Healthcare  Lodging  Public Assembly  Laboratory  Cleanroom  Datacenter  Mixed Use  More choices... > Location > Vintage This View: California > large office > total energy > all end uses > quintiles Project Profile: Large Office, California, 100ksf, Electric+Fuel Results: Typical large office buildings use 191 kBTU/ft2-year. Enter your own building information at the left to see how yours compares. Or, enter all information in Project Profile Energy IQ Action-oriented energy benchmarking for non-residential buildings About | How to use | My IQ Help Center | Privacy Export | Import Sign in/out Energy, or... Characteristics & Operations, or CombinationsIndicatorsViews Total energy  Lighting Quantity  Summary  Electricity  Envelope  Cost  End Uses  Peak power  Air Handling  Emissions Distribution  Fuel  Chillers  Thermal  Boilers  Hot Water  Plug/Process To Compare Your Building, Enter: Conditioned floor area (sf): Total energy use  Electricity (MWh):  Fuel (MBTU):  Other (MBTU): 100, BenchmarkActions

Questions? Paul Mathew MS Lawrence Berkeley National Laboratory 1 Cyclotron Road, Berkeley CA (510)