Chemistry Teaching Laboratory Fume Cupboard Refurbishment – University of Leeds Bob DouglassEnergy Officer.

Slides:



Advertisements
Similar presentations
Business and Environment Management Scheme (BeMS) Mathonwy Suter.
Advertisements

Energy Conservation Energy Management.
Architectural Services Department HKSAR Laboratory Design for Secondary Schools.
It is essential that CSU lead by example and continue to address sustainability “ ”
OPPORTUNITIES FOR BUSINESSES TO DIRECTLY IMPROVE THE BOTTOM LINE THROUGH ENERGY EFFICIENCY 3 rd May 2010 Kees Brinkman Managing Director.
MSAENV472B Implement and Monitor Environmentally Sustainable Work Practices Neale Farmer – Coordinator Major Environmental Initiatives – Hunter TAFE
BREEAM use at the University of Bristol. Overview Background Our Approach Progress to date Lessons learnt.
Heat Recovery for Commercial Buildings
The average Kiwi emits 19.3 tonnes of CO 2-e per annum.
1 A sustainable UCL means a campus which: Support current business needs whilst allowing flexibility for future use with minimum intervention Minimise.
North American Operations Kalamazoo Plant Welcome to Kalamazoo.
Summary of Heat Loss Calculations Assessing overall heating requirements for building (E) Component U-ValueAreaHeat Loss Rate (W o C -1 ) Walls U walls.
Lab Banding  More than assigning # of air changes/hour to lab  Lab operations risk assessment with hands on approach to ensure safe operation while reducing.
Lab Energy Management Big Ten Mechanical & Energy Conference October
GReening business through the Enterprise Europe Network EN Giovanni FRANCO European Commission Enterprise and Industry EN
BRE Energy Efficient Office of the Future
When Do Variable Flow Fume Hoods Save Energy? Implications for lab design and behavior modification Michael Gevelber, Robert Choate, Kevin Sheehan, Brian.
ASHRAE Club Project VAV Fumehood Retrofit - Engineering III Building Engineering III Building 40,000 gsf Completed 2002 Designed and constructed in two.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
United States Air Force - Eglin Air Force Base. Eglin Air Force Base Energy Management Air Force Energy Plan (overview) Air Force Infrastructure Energy.
How ICT can Create a Leaner and More Sustainable Estate
ENERGY EFFICIENCY FOR END-USERS.  CSU Chancellors office coordinates the efforts to accomplish the goals established by Assembly Bill 32 for green house.
Engineer Presentation
DATA-BASED COMMISSIONING BUILDING-WIDE FUME HOOD FACE VELOCITY REDUCTION MIT Laboratory Energy Efficiency Case Studies.
Environmental Management. QUB Carbon Management Strategy.
Green Campus Energy Efficient Behaviour in Laboratories – The Green Action Campaign at University of Copenhagen Tomas Refslund Poulsen, Team leader Green.
Taking Action on Climate Change John Sugden Head of UK Facilities Management Thinking About Tomorrow Today.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
Reducing Energy Consumption The DWP approach Case Study 3.
Toward a Sustainable Campus Part II: Improving the Efficiency of the CNS Building Energy Systems Nitin Rajan ‘07 Physics Department Ithaca College.
Effective Energy Management. Keys Save energy Lower utility operating costs Maintain or improve operations Support corporate goals.
Imperial College Carbon Management Plan The Carbon Management Plan Imperial College Facilities Management June 2010.
DEPT OF ESTATES AND FACILITIES Engineering Team DEPT OF ESTATES AND FACILITIES Engineering Team Too hot, too cold, just right Presented by: Russell Smith.
Staff Induction-Environmental Awareness
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
UK Energy Efficiency Chris Leigh Household Energy Efficiency and Fuel Poverty Climate Change Group DECC.
CRC Energy Efficiency Scheme Summary of key points.
1 Kevin Cope Imperial College London Head of Building Operations Carbon Management Plans - achievements, maintenance and the future.
Green Project Proposal MORE SAFE; LESS POWER from our use of Fume Cupboards School of Agriculture, Food & Wine.
ENERGY CONSERVATION & BUILDING STANDARDS Brian Deal, Fred Hahn, Karl Helmink, Claire McConnell, Dhara Patel, Claudia Szczepaniak, Scott Willenbrock.
Energy & Environment Report for 2008 – 2009 Ian Rowe Manager (Health, Safety & Environment)
Sustainability and Public-Private Initiatives Sean Patton Director, Energy Solutions LOCKHEED MARTIN CORPORATION JUNE 8, 2012 Sustainability for the Future.
Cutting the Corporate Energy Bill 20 th November, 2013 Marginal gains and why they matter David Collier, Energy and Sustainability Manager.
Smartcool Systems Inc. Providing effective and reliable energy efficiency solutions for HVAC-R customers around the globe.
The EWZ building Presentation of the building Presentation of the building The design issue The design issue The building concept The building concept.
Sawyer Environmental Changes Mechanical Engineering Department Capstone Amy R. Dan H. Colby C. Brittany P. Richard G. 1.
Marty Matlock, PhD, PE, BCEE Executive Director, Office for Sustainability Professor,UA Division of Agriculture Biological and Agricultural Engineering.
BREEAM HIGHER EDUCATION AND LABORATORIES Peter James Higher Education Environmental Performance Improvement (HEEPI)
Nicholas J. Hennessy, Ph.D Sustainability Coordinator Bowling Green State University Energy Conservation Measures: It Takes a Community.
Greening Your Lab Responsible Conduct of Research Duke University October 8, 2013.
Embedding Carbon Management within Public Sector Organisations 17 th November 2015.
Sustainability reporting John Maddocks - CIPFA. cipfa.org.uk Sustainability accounting and reporting can … … ‘enable the systematic identification and.
Sustainability and Facilities Management John Sullivan Energy & Sustainability Office Facilities & Services Division.
1 Case study: Sofia District Heating Dr. Venkata R. Putti Team Leader, Carbon Finance Assist The World Bank Minsk / Belarus, March 2007.
Planit uses a simple but robust eight step process to promote the consistent formulation of quality internal communication plans. Eight step planning process.
Sustainability Its our choice Presenters of this discussion topic Jon Howard Director of Estates (Sponsor) Shane O Donnell Maintenance Officer (Lead)
Calculating a CO 2 Inventory for Pacific Northwest National Laboratory Federal Environmental Symposium – East Kim Fowler Senior Research Engineer Pacific.
E.ON Russia Production management September 2013 Deputy General Director on production Igor Popov.
Improving performance, reducing risk Dr Apostolos Noulis, Lead Assessor, Business Development Mgr Thessaloniki, 02 June 2014 ISO Energy Management.
Metering and Monitoring  The Business Case.  Implementing the project.  Benefits – accurate data and data analysis.  On-going challenges.
Neighbourhood Services Scrutiny Committee 27 March 2008 Pilot Project on Assistive Technology Keith Hannah, Head of Directorate Support.
University of Oxford Environmental Sustainability Team Environmental Sustainability at the University of Oxford Twitter and £
PROCEDURE FOR ENTRY AND WORK IN LABORATORIES (Revision 2 – 29 th March 2011) Toolbox Talk.
Excess winter deaths and morbidity and the health risks associated with cold homes Chris Connell Implementation Consultant September 2015.
HVAC Energy Efficiency using Mass Flow and Building Pressurization Jay Richardson Professional Supply, Inc.
Environmental Performance Prepared for CFOA, London, 28th January 2010 By Matt Farnsworth: Environment & Sustainability Manager, Nottinghamshire.
A&P Falmouth Ltd ENERGY 09 TEAM
Sustainability Its our choice
Case Study: Marks & Spencer Oxford Street
Presentation transcript:

Chemistry Teaching Laboratory Fume Cupboard Refurbishment – University of Leeds Bob DouglassEnergy Officer

University Targets 35% Carbon emission reductions against 2005/6 baseline by Target is annual emissions of 24,400 tonnes of carbon by /13 data: Energy Cost £13,245,508 Total energy used 193,310MWh Carbon emitted 57,063 tonnes

Implementing the CMP The aims of the Universities Carbon Management Plan are threefold: – To make a significant contribution to government carbon targets. – To help the University deliver its core business in a more sustainable way – To save money Delivered by embedding energy reduction into everything we do e.g. procurement & day-to-day management systems. However, majority of savings coming through building disposal, refurbishment (fabric & services improvement) & engineering solutions.

Energy Data Key Performance figures 2012/132011/12 Carbon emitted (tonnes)57,06370,874 Energy consumption (MWh)193,310217,414 Energy costs£13,245,508£13,005,778

Fume Cupboard Energy Savings Over 270 ducted fume cupboards on main campus Each cupboard can potentially consume the equivalent energy of 2-3 houses over the course of a year. Equivalent to 18 tonnes of Carbon per cupboard per annum Energy costs can be significantly reduced through good design and simple management steps

Priestley Laboratory Fume Cupboard Refurbishment. Chemistry building selected for review as second largest energy consumer Priestley Laboratory large 765m 2 teaching laboratory with 63 fume cupboards. Total energy used for year measured as 4360MWh, 1171 tonnes carbon. £187, VAT £345,000 from Carbon Management Plan budget spent upgrading fume cupboard systems

The Process - Key Elements Engage with stakeholders, before, during and after the project Multi-disciplinary proactive internal planning team. Risk and Feasibility Analysis Design consultant with a documented track record in sustainable design, working with Fume Cupboard and BMS specialist. Measurable goals with metrics tracked consistently during and after the design process. The primary metrics being user safety, ease of use and maintainability and energy efficiency. Project review

Containment One particular area of concern to the users was the proposed reduction of air face velocity from 0.5m/s to 0.4m/s. To allay these concerns we arranged for a specialist contractor to undertake an on-site robustness test to BS EN14175 using sulphur hexafluoride (SF6) as the trace gas. The test results showed that at 0.4m/s the containment of the cupboard was proven with a containment of less than 0.01ppm recorded. Subsequent SF6 testing was undertaken at the end of the project to ensure containment was achieved.

Feasibility Gordon Sharp PD pressure drop HR heat recovery

Constant Volume Fume Cupboards Existing duct work systems and cupboards upgraded to changed from constant volume to variable volume operation. Mechair

Variable Air Volume Cupboards Mechair

Control Schematic

To turn the fume cupboards into VAV systems fast acting motorised dampers were fitted to each of the 63 fume cupboards along with new cupboard controllers. To maintain stack discharge velocity and reduce control volatility motorised bleed damper were fitted to the eight roof mounted extract fan systems, these modulating to maintain a constant duct pressure. Each extract fan serves up to eight cupboards in the laboratory below. Motorised Dampers

Dedicated Storage Extract Independent solvent and chemical storage cupboard ventilation system installed to extract from end of line and under cupboard storage cabinets.

Passive Infra-red sash prompts fitted to cupboards to prompt users to close sashes if left open and unattended for more than 2 minutes. Controller sound alarm and flashes warning text advising user to shut sash. Sash Prompts

User Controls Improved local controls to enable lab staff to select appropriate number of fume cupboards for class size and isolate those cupboards not required.

Install remote monitoring system using a SIP modbus interface to export data and energy sub metering to Trend BMS graphics page and M&T software package. Remote Monitoring

Behavioural Change Promoted behavioural change with Sustainability Service “Shut the Sash” campaign

Out of Hours Bypass Install a bypass duct from dilution system 5 to dilution system 4 to allow bank of eight cupboards to run outside of normal hours without having to enable full system

From Space

Summary Existing duct work systems and cupboards upgraded to change from constant volume to variable volume operation. Independent solvent and chemical storage cupboard ventilation system installed Duct work altered to provide energy efficient facility for 8 Cupboards to operate outside of normal operational hours Passive Infra-red sash prompts fitted to cupboards to prompt users to close sashes if left open for more than 2 minutes. Improved local controls to enable lab staff to select appropriate number of fume cupboards for class size and isolate those cupboards not required. Install remote monitoring system and energy sub metering to check operation. Promoted behavioural change with Sustainability “Shut the Sash” campaign

What did we achieve? Over a 6 month period we recorded the following savings: A reduction in thermal energy of 1647MWh th A reduction in electrical energy of 347MWh e Energy costs reduced by £81, net 511 tonnes of carbon saved.

In addition: Raised awareness amongst staff and students of fume cupboard operational costs and in particular the role they can play in reducing costs. Behavioural change in use of fume cupboard sashes resulting in safer and more energy efficient operation. Improved reporting, monitoring and analysis of fume cupboard use. A quieter and more comfortable working environment due to the reduction in supply and extract air volumes.

Priestley Laboratory Steam Consumption

Chemistry South Wing Electrical Consumption (kWh)