NMR Spectroscopy Tuning / Matching Shimming and Lock.

Slides:



Advertisements
Similar presentations
The analytical measurement principle
Advertisements

PHYSICS OF MAGNETIC RESONANCE
Understanding Electrical TransmissionDemonstration B2 A Guide to the National Grid Transmission Model Demonstration B2 Generating electricity.
1 NMR Instrumentation Modern Pulsed Fourier Transform NMR Spectrometer with superconducting magnet Why? Superconducting Magnet Computer Electronics Console.
The Basics of MRI The Basics of MRI. Current MRI technology displays images as multiple sets of gray tone images. Visualization and interpretation of.
Nuclear Magnetic Resonance
1. Output signal alternates between on and off within specified period Controls power received by a device The voltage seen by the load is directly proportional.
Analogue to Digital Conversion
NMR SPECTROSCOPY.
Chapter 5 How the spectrometer works Magnet Probe Transmitter SynthesizerReceiver ADC Pulse programmer Computer 5.1 The magnet: 1. Strength: 14.1 T for.
NMR Spectroscopy Spectrometer -Hardware
1 NMR Practical Aspects (I) Processes involving in a NMR study: 1. Sample Preparation/Considerations 2. Setting up Spectrometer 3. Setting up acquisition.
NMR Spectroscopy Part II. Signals of NMR. Free Induction Decay (FID) FID represents the time-domain response of the spin system following application.
Solid-state 2 H NMR Spectroscopy for the Undergraduate Physics Laboratory Jacob J. Kinnun, Avi Leftin, Michael F. Brown University of Arizona, Tucson,
The NMR spectrometer Magnet Probe Coils Transmitters
Noise near peak field is increased Peak width narrow Peak is symmetric Purpose: Resonate nuclei to prevent polarization. Matching the resonant frequencies.
FT-NMR.
Multichannel Analyzers A multichannel pulse-height analyzer (MCA) consists of an ADC, a histogramming memory, and a visual display of the histogram recorded.
Data Acquisition. Data Acquisition System Analog Signal Signal Conditioner ADC Digital Processing Communication.
Oscilloscope Tutorial
PH4705/ET4305: A/D: Analogue to Digital Conversion Typical Devices: Data sheets are on the web site for A/D 8 bit parallel AD7819 and serial ADC0831 And.
Computer Based Data Acquisition Basics. Outline Basics of data acquisition Analog to Digital Conversion –Quantization –Aliasing.
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
Engineering 1040: Mechanisms & Electric Circuits Winter 2015 Analog & Digital Signals Analog to Digital Conversion (ADC)
1 Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A.
LSU 06/04/2007Electronics 61 Data Acquisition Electronics Unit – Lecture 6 Sensors and Transducers Signal conditioning Data sampling and recording.
What is NMR? NMR is a technique used to probe the structure of molecules. Paired with other techniques such as MS and elemental analysis it can be used.
Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A class.
Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A class.
05- NMR Instrumentation 1.Overview of the JEOL LA400 2.Superconducting magnet 3.The magnetic field and homogeneity 4.Field frequency lock 5.Pulse program.
W HAT IS NUCLEAR MAGNETIC RESONANCE ? State that NMR spectroscopy involves interaction of materials with low-energy radio frequency radiation. Describe.
3 He Polarization Tests at UIUC Danielle Chandler David Howell UIUC.
10 – Experimental aspects of NMR 1.The NMR tube 2.NMR solvents 3.The sample 4.How much time does an NMR experiment require? 5.Line shape 6.NMR coils 7.Shimming.
V. Rouillard  Introduction to measurement and statistical analysis DIGITAL SAMPLING - DIGITISATION Digital sampling is mainly used in data acquisition.
Oscillator Oscillation Level Detector Current Source Oscillation Level at fixed frequency ‘ν’ When No ESR Oscillation Level reduced when there is ESR.
Figure 8.3 gives the basic layout of a continuous wave NMR spectrometer. These intruments were the original type of instrument and have largely.
PULSED NMRAcquire F.I.D. Free Induction Decay NMR detection soon after a strong pulse: precessing nuclear magnetization induces a signal in coil when it.
Principles and Applications of NMR Spectroscopy Instructor: Tai-huang Huang (02)
Ultra-low Field Nuclear Magnetic Resonance Measurements with SQUIDs
Comparators, DAC, and ADC
Tuning, Lock and Shimming Claridge- 3.3, 3.4, 3.6.
Nuclear Magnetic Resonance
Primarily, Chapter 3 Claridge Also, Chapter 2 Claridge,
1 Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A.
1. What is an NMR Spectrum ? 2. What are the Spectral Features? 3. What are the Spectral Parameters? 4. How much should be known about the NMR Phenomena.
Analogue to Digital Conversion © D Hoult analogue signal © D Hoult 2011.
1 Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A.
Experimental Detection of the Magnetic Resonance signal requires setting up a non-equilibrium state What is the thermal equilibrium available to start.
0808/0809 ADC. Block Diagram ADC ADC0808/ADC Bit μP Compatible A/D Converters with 8-Channel Multiplexer The 8-bit A/D converter uses successive.
MOLECULAR STRUCTURE ANALYSIS NMR Spectroscopy VCE Chemistry Unit 3: Chemical Pathways Area of Study 2 – Organic Chemistry.
Sampling. Introduction  Sampling refers to the process of converting a continuous, analog signal to discrete digital numbers.
Guided by: Dimal Shah Prepared by: Shweta Singh IICP NEW V.V. NAGAR....1.
Tuning, Lock and Shimming
CLARIDGE CHAPTER 2.2; 3.2.
(Instrument part) Thanundon Kongnok M
Chem. 133 – 4/18 Lecture.
Extending the Range of eZ430-TMS37157 PaLFI
ECE-L304 Lecture 3.
Analogue to Digital Conversion
A Fortran Program for Fourier Transformation
FT NMR WORKSHOP/===/ S.A.I.F./===/ NEHU/==/ Shillong
Nuclear Magnetic Resonance
10.5 Fourier Transform NMR Instrumentation
10.6 Fourier Transform Mass Spectrometry
Nuclear Magnetic Resonance
Structure determination by NMR
Recap In previous lessons we have looked at how numbers can be stored as binary. We have also seen how images are stored as binary. This lesson we are.
1H and 13C NMR Spectroscopy in Organic Chemistry
(4)ELECTRONIC SUPPORT SYSTEM
Presentation transcript:

NMR Spectroscopy Tuning / Matching Shimming and Lock

Tuning the probe Tuning change the resonant frequency Matching adjust the impedance

Tuning Probe

Deuterium Lock High resolution NMR measurements require a special field- frequency stabilization to allow accumulation of signals, which may be separated by less than 1 Hz. Lock is to hold the resonance condition by by separate NMR experiment running parallel to the one on the observe channel. Usually the deuterium resonance of the deuterated solvent is used to provide the NMR lock signal. Digital lock: lock signal is fed directly into ADC and displayed on the computer. A narrower lock signals results in higher DC voltage after rectification. By adjusting the various shim currents one aims for an optimum lock signals.

Deuterium Lock

Shimming The process of optimizing the magnetic field homogeneity for recording high resolution spectra is called shimming a magnet. Small coils on pole faces in carefully chosen geometry. Currents in these coils are adjusted. Two types of gradients : spinning (Z0 to Z5) non-spinning (X, Y, … ) First orderZ1, X, Y Second OrderZ2 Higher orderZ3, Z4 …

Shimming Proton line width in a standard sample should be less than 0.5 Hz with spinner on. Non-spinning proton line width in a 5 mm probe can be easily adjusted to about 2 Hz.

Shimming

Free Induction Decay (FID) FID represents the time-domain response of the spin system following application of an radio-frequency pulse. With one magnetization at  , receiver coil would see exponentially decaying signal. This decay is due to relaxation.

Free Induction Decay (FID)

Sampling the Signal

ADC (Analog to Digital Converter) The analogue signal generated in the coil by the sample should be digitized before it can be handled by the computer. The input of ADC is the signal voltage, the output is a binary number proportional to it.

Sampling the Signal Factors determine the performance of ADC Number of bits the ADC uses to represent the signal voltage The maximum conversion speed The number of bits in single word of computer memory

Sampling the Signal Spectral WidthThe maximum spectral width is determined by the ADC conversion time which limits the rate of signal sampling ms generates maximum spectral width of 50 kHz to 150 kHz. Dynamic rangeThe ability of ADC to digitize weak signals faithfully in the presence of string signals. 12 bits to 20 bits are often referred to ADC.

NMR line shape Lorentzian line Aamplitude Whalf-line width